Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical optical imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

43 records · Page 3

Shape-Controlled Synthesis of Copper Nanocrystals for Plasmonic, Biomedical, and Electrocatalytic Applications

As a metal that can occur in nature in the elemental form, copper (Cu) has been used by humans since ca. 8000 BC. With most properties matching those of Ag and Au, Cu has played a more significant role in commercial applications owing to its much higher (the 25th among all elements) abundance in Earth’s crust and thus more affordable price. In addition to its common use as a conductor of heat and electricity, it is a constituent of various metal alloys for hardware, coins, strain gauges, and thermocouples. Bulk Cu is also widely utilized as a building material. When downsized to the nanoscale, Cu and Cu-based structures have found widespread use in applications ranging from electronics to optoelectronics, plasmonics, catalysis, sensing, and biomedicine. Besides Ag and Au, for example, Cu is another metal known for its localized surface plasmon resonance (LSPR) in the visible and near-infrared regions when prepared as nanocrystals. As a potential replacement for indium–tin oxide (ITO) films, polymer coatings containing Cu nanowires are strong candidates for the fabrication of transparent and flexible electrodes key to touchscreen display and related applications. The commercial catalysts for water–gas shift and gas detoxification reactions are also based on Cu nanoparticles. Most recently, Cu nanocrystals have attracted considerable interest for their superior selectivity toward hydrocarbons and multicarbon species during the electrochemical reduction of CO 2 . The success of all these applications critically depends on our ability to control the shape and surface structure of the nanocrystals. Relative to Ag and Au, it is more challenging to generate Cu-based nanocrystals using colloidal methods due to its lower reduction potential and greater vulnerability to oxidation. Here, in this account, we discuss recent progress in the colloidal synthesis of Cu nanocrystals with controlled shapes for plasmonic, biomedical, and catalytic applications. With glucose serving as a reducing agent, Cu nanocrystals bearing a twinned or single-crystal structure can be synthesized using an aqueous system with the assistance of hexadecylamine (HDA). In this synthetic protocol, HDA not only passivates the surface to protect the nanocrystals from oxidation but also manipulates the reduction kinetics of Cu(II) precursor through coordination and an increase of solution pH. Typical products include nanocubes and penta-twinned nanowires whose surfaces are dominated by {100} facets. When seeds produced either in situ or ex situ are introduced, Cu-based nanocrystals featuring a singly twinned, core–shell, or Janus structure can be readily synthesized. Aside from segmented structures, Cu-based alloys with various noble metals can be synthesized through coreduction or a galvanic replacement reaction with preformed Cu nanocrystals. By controlling the size and/or shape of Cu nanocrystals, their LSPR peaks can be tuned into the near-infrared region, making them promising candidates for optical imaging contrast enhancement and photothermal treatment. The inclusion of the 64 Cu isotope makes them immediately useful in positron emission tomography and thus image-guided therapy. The surface structure, elemental distribution, and valence state of Cu-based nanocrystals can all be tailored to augment their electrocatalytic performance. It is hoped that this Account will inspire more studies into the development of rational methods capable of producing Cu-based nanocrystals with diverse and well-controlled shapes, internal structures, and compositions for a broader range of applications.

36 MATERIALS SCIENCE↗

High-throughput terahertz imaging: progress and challenges

Abstract Many exciting terahertz imaging applications, such as non-destructive evaluation, biomedical diagnosis, and security screening, have been historically limited in practical usage due to the raster-scanning requirement of imaging systems, which impose very low imaging speeds. However, recent advancements in terahertz imaging systems have greatly increased the imaging throughput and brought the promising potential of terahertz radiation from research laboratories closer to real-world applications. Here, we review the development of terahertz imaging technologies from both hardware and computational imaging perspectives. We introduce and compare different types of hardware enabling frequency-domain and time-domain imaging using various thermal, photon, and field image sensor arrays. We discuss how different imaging hardware and computational imaging algorithms provide opportunities for capturing time-of-flight, spectroscopic, phase, and intensity image data at high throughputs. Furthermore, the new prospects and challenges for the development of future high-throughput terahertz imaging systems are briefly introduced.

36 MATERIALS SCIENCE↗

Tunable phase-change metasurfaces coupled with mid-infrared molecular vibrations

Chiral optical metasurfaces have emerged as a promising platform in coupling with molecular vibrational fingerprints through the enhanced light-matter interaction under different circularly polarized light illumination. Here, this work reports the mode coupling between the mid-infrared phonon vibrations of polymethyl methacrylate (PMMA) molecules and the thermally tunable chiral metasurfaces based on the phase-change material Ge₂Sb₂Te₅ (GST-225). Phase-change chiral metasurfaces with high circular dichroism (CD) in absorption and tunable plasmonic resonance in the frequency range of 48–56 THz are demonstrated, which covers the phonon vibrational frequency of PMMA molecules at 52 THz. The mode splitting features are observed in the absorption and CD spectra when the metasurface resonance is tuned across the phonon vibrational frequency of PMMA molecules during the phase transition of GST-225. The underlying mechanism of molecule-metasurface coupling is further revealed by studying the electric field and power loss density distributions of the phonon–plasmon coupled modes under both left-handed and right-handed circularly polarized (LCP and RCP) light. The demonstrated results show the potential of dynamically tunable chiral metasurfaces for the applications in label-free molecular sensing, biomedical diagnostics, thermal imaging, and mid-infrared photonics.

Tang, Haotian [Missouri Univ. of Science and Techn↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gravity Sensors and the Role of 3-D Visualization and Simulation in Biomedical Research

Ross 3.0 software was developed in the Biocomputation Center for semi-automated reconstruction of objects from serial thin sections. Data are captured directly from a transmission electron microscope via a video camera to a graphics workstation where the sections are mosaicked and contours are traced, registered and displayed by semi-automated methods. For the first time, macular type II cells are described completely for their innervation patterns. The purposes are to learn more about the fundamental circuitry of the macula and to demonstrate whether the terminals are altered morphologically by space flight. Current examples, from the medial part of the macula, are from maculas collected in-flight on the Space Life Sciences-2 mission, 4.5 hrs post-flight, and from a ground control. Results show that the typical type 11 cell receives processes from up to six nearby calyces or afferents. Nearly all the processes are elongated; some have bouton-like swellings and numerous vesicles. Multiple (2 to 4) processes from a single calyx to a type II cell are common, and approx. 1/3 of the processes innervate 2 type II cells of a neighboring cluster of 3 cells. About 2% of type II cells resemble type I cells morphologically and are surrounded by demicalyces. Differences in size or shape of the terminals under flight conditions could not be determined because the sample size is still too small; but it is clear that reconstruction methods provide insights into macular circuitry not obtainable by other techniques. The results demonstrate a morphological basis for interactions between adjacent receptive fields, through feedback-feedforward connections, during preprocessing of linear acceleratory information by the maculas. While the methods are currently being tested using vestibular maculas as the model system, it is clear that the technology is applicable to any tissue that can be physically or optically sectioned. ROSS software has already been implemented for reconstructing objects from tissues studied by confocal and by transmitted light microscopy, and research into magnetic resonance imaging-computational tomography combined visualization are underway.

Ross, Muriel D.↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

Nanodiamonds in Advancing Biomedical Sciences

Nanodiamonds (NDs), tetrahedral carbon frameworks with size ranging from 1 to 100 nanometers, have gained growing attention in recent years due to their distinct optical, thermal, and mechanical properties compared to other carbon nanomaterials (e.g., graphene, carbon nanotubes, carbon dots). Combined with a high surface-to-volume ratio and tunable and chemically versatile surfaces, these support broad applications across catalysis, electronics, and life sciences. Moreover, the biocompatible characteristics of NDs enable their controllable interfacial interactions with biological systems, positioning them as excellent candidates for advancing cutting-edge biomedical sciences, particularly through the engineering of efficient material-biointerfaces that facilitate optimal interactions with biological systems. Among various forms of NDs, fluorescent nanodiamonds (FNDs) have emerged as some of the most impactful and rapidly advancing materials, demonstrating strong potential in ultrasensitive spin-enhanced bioimaging, high-precision biosensing, traceable drug delivery, and quantum-enabled biomedical technologies. This Perspective introduces the key principles underlying NDs and FNDs, including their structural properties, synthesis methods, and surface functionalization strategies. It also highlights emerging biomedical applications of NDs and FNDs, with particular emphasis on neurological disorders. Last, the article discusses current challenges in advancing NDs as a multifunctional platform for neural therapies with translational potential toward clinical trials.

36 MATERIALS SCIENCE↗