Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bill of materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Electrolyzers for Hydrogen Production: Solid Oxide, Alkaline, and Proton Exchange Membrane

The effects of climate change have led to a push for cleaner energy sources across multiple sectors. Hydrogen has emerged as a promising energy carrier in this context, as it can be produced using various water electrolysis technologies capable of utilizing clean power (e.g., nuclear and renewable electricity). However, a comprehensive environmental assessment of these technologies requires an understanding of the environmental impacts during their complete life cycle, including the embodied emissions in their material composition and during their manufacturing stages; these emissions are often neglected. This report provides a brief overview of major water electrolysis technologies, viz., proton exchange membrane electrolyzer cell (PEMEC) or polymer electrolyte membrane (PEM), alkaline electrolysis cell (AEC) and solid oxide electrolysis cell (SOEC), along with a detailed bill of materials for these technologies that has been incorporated in the updated G reenhouse gases, R egulated E missions, and E nergy use in T ransportation (GREET ® ) 2022 model. We also provide an inventory for the intermediate materials used to produce these electrolyzers, which has not been covered in prior releases. Using these material and energy flows, the GREET model provides a detailed life cycle inventory (energy use and emissions) from raw material extraction through complete production of electrolyzers for major electrolysis technologies.

08 HYDROGEN↗

MATE (Materials for Advanced Turbine Engines) Program, Project 3. Volume 2: Design, fabrication and evaluation of an oxide dispersion strengthened sheet alloy combustor liner

The suitability of wrought oxide dispersion strengthened (ODS) superalloy sheet for gas turbine engine combustor applications was evaluated. Two yttria (Y2O3) dispersion strengthened alloys were evaluated; Incoloy MA956 and Haynes Development Alloy (HDA) 8077 (NiCrAl base). Preliminary tests showed both alloys to be potentially viable combustor materials, with neither alloy exhibiting a significant advantage over the other. MA956 was selected as the final alloy based on manufacturing reproducibility for evaluation as a burner liner. A hybrid PW2037 inner burner liner containing MA956 and Hastelloy X components and using a louvered configuration was designed and constructed. The louvered configuration was chosen because of field experience and compatibility with the bill of material PW2037 design. The simulated flight cycle for the ground based engine tests consisted of 4.5 min idle, 1.5 min takeoff and intermediate conditions in a PW2037 engine with average uncorrected combustor exit temperature of 1527 C. Post test evaluation consisting of visual observations and fluorescent penetrant inspections was conducted after 500 cycles of testing. No loss of integrity in the burner liner was shown.

Bose, S.↗

Two Dimensional Viscoelastic Stress Analysis of a Prototypical JIMO Turbine Wheel

The designers of the Jupiter Icy Moons Orbiter (JIMO) are investigating the potential of nuclear powered-electric propulsion technology to provide deep space propulsion. In one design scenario a closed-Brayton-cycle power converter is used to convert thermal energy from a nuclear reactor to electrical power for the spacecraft utilizing an inert gas as the working fluid to run a turboalternator as described in L.S. Mason, "A Power Conversion for the Jupiter Icy Moons Orbiter," Journal of Propulsion and Power, vol. 20, no. 5, pp. 902-910. A key component in the turboalternator is the radial flow turbine wheel which may be fabricated from a cast superalloy. This turbine wheel is envisioned to run continuously over the life of the mission, which is anticipated to be about ten years. This scenario places unusual material requirements on the turbine wheel. Unlike the case of terrestrial turbine engines, fatigue, associated with start-up and shut-down of the engine, foreign-object damage, and corrosion issues are insignificant and thus creep issues become dominate. The purpose of this paper is to present estimates for creep growth of a prototypical JIMO turbine wheel over a ten year life. Since an actual design and bill of materials does not exist, the results presented in this paper are based on preliminary concepts which are likely to evolve over time. For this reason, as well as computational efficiency, a simplified 2-D, in lieu of a 3-D, viscoelastic, finite element model of a prototypical turbine wheel will be utilized employing material properties for the cast superalloy MAR-M247. The creep data employed in this analysis are based on preliminary data being generated at NASA Glenn Research Center.

Gayda, John↗

Storm DEPART(Damage Estimate Prediction And Recovery Tool)

Damage prediction, materials needed, and resource allocation modeling capability in order to support pre-incident planning and preparation by predicting damage to the power generation capacity, transmission grids, distribution networks, and communications assets. The capabilities will be developed by multiple factors to include wind bands, storm surge, and flooding forecasts to participant’s assets which will result in a report of predicted damages. Additional factors to include available participants infrastructure data to include class, age, construction, location, wind rating, and additional information not in the public domain. Based on predicted damages, the output will be a bill of materials (BOM) to support short-term recovery operations. The extensiveness and level of detail for this BOM will depend on the replacement configuration specifications provided for each individual participant asset. Any limiting factors for the model will be applied related supply chain and resource constraints.

Klett, Mary↗

Onymous early‐life performance degradation analysis of recent photovoltaic module technologies

Abstract The cost of photovoltaic (PV) modules has declined by 85% since 2010. To achieve this reduction, manufacturers altered module designs and bill of materials; changes that could affect module durability and reliability. To determine if these changes have affected module durability, we measured the performance degradation of 834 fielded PV modules representing 13 module types from 7 manufacturers in 3 climates over 5 years. Degradation rates ( Rd ) are highly nonlinear over time, and seasonal variations are present in some module types. Mean and median degradation rate values of −0.62%/year and −0.58%/year, respectively, are consistent with rates measured for older modules. Of the 23 systems studied, 6 have degradation rates that will exceed the warranty limits in the future, whereas 13 systems demonstrate the potential of achieving lifetimes beyond 30 years, assuming Rd trends have stabilized.

14 SOLAR ENERGY↗

Economic and embodied energy analysis of integrated circuit manufacturing processes

Integrated circuits (ICs) are the fundamental microelectronic building blocks of typical information and communication technology (ICT) devices such as laptops and smartphone. With the emergence of faster and cheaper low-power ICs for the growing ICT market, there is a limited information on their manufacturing energy and economic impacts owing to the lack of recurrent upgradation of proprietary IC manufacturing process data. In this work, economic and life cycle energy assessments (LCAs) of IC manufacturing and assembly processes were conducted using the latest bill of materials (BOM) manufacturing data in a state-of-the-art IC manufacturing cost software tool developed by IC Knowledge, LLC. IC manufacturing cost was estimated to be $\$$1.00-$\$$5.00/cm 2 ; the high-end cost represents the most advanced 3D NAND IC technology with the Wafer Level Chip Scale Package cost of $4/cm 2 . Total cumulative energy demand (CED) estimates of IC manufacturing using the OpenLCA software ranged from 9 to 38 MJ/cm 2 or 56–235 BJ/month with the largest share (~ 75%) from on-site energy. The IC manufacturing CED is projected to increase with the progress in IC technology node, which has increased by more than two times for technology node evolution from 110 to 14 nm. Furthermore, the representative detailed BOM data were considered to reduce the CED uncertainties of the estimated standard deviation of 35%- 42%.

97 MATHEMATICS AND COMPUTING↗

HunStat – a simple and low-cost potentiostat for analytical and educational purposes

We have developed a truly low-cost (15 USD), simple do-it-yourself (DIY) potentiostat with compact dimensions. The output potential range of this device is between ±1.65 V. The developed instrument takes advantage of a Seeeduino XIAO microcontroller equipped with 10 bit digital-to-analog (D/A) and 12 bit analog-to-digital (A/D) converters and supports various voltammetry techniques, including cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CA). Interested users are provided with circuit diagrams, bill of materials, and design files. Additionally, software components are also provided free of charge, including an Arduino sketch and control software. The software enables easy manipulation of electrochemical parameters and visualization of results. The presented design introduces a simple and low-cost DIY potentiostat recommended for both analytical and educational purposes.

47 OTHER INSTRUMENTATION↗

HunStat2 – a simple and low-cost potentiostat with electrochemical impedance spectroscopy capability

We have developed a low-cost (30 USD), simple do-it-yourself (DIY) potentiostat with cyclic voltammetry (CV), open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) capability. The HunStat2 potentiostat is based on Analog Devices' AD5941 Analog Front End chip, which significantly simplifies the construction of potentiostats for both direct and alternating current (DC and AC, respectively) techniques. Interested readers are provided with circuit diagrams and a bill of materials to build the potentiostat on their own. In addition, control software is also provided free of charge. The software enables acquisition and visualization of data. In summary, HunStat2 introduces a simple and low-cost DIY potentiostat recommended for both analytical and educational purposes.

Vamos, Istvan [Lajos Petrik Vocational Chemistry S↗

Ultraviolet Fluorescence Bleaching Rates for New Cell Cracks

Ultraviolet Fluorescence (UVF) is an inspection tool that can be used to identify cell cracks in some photovoltaic (PV) modules. Cell cracks can also be identified with electroluminescence (EL) and similar techniques, but it is generally not possible to differentiate new cracks from old ones with EL. UVF has a unique property of taking time for the cracks to show up, which could be used to differentiate new cracks (e.g., from a recent storm) from old ones (e.g., from installation damage). We perform tests on several different modules, some the same make and model but with different bill of materials (BOMs), to characterize the amount of time that it takes for crack signatures to progress in UVF.

41 EE - Solar Energy Technologies Office (EE-4S)↗

EyeON

EyeON: Eye on Operational technology Software Supply Chain attacks have risen drastically over the past few years, none more well-known and impactful than the SolarWinds compromise. Criminal organizations inserted an attack vector into a specific version of the source code, giving themselves an air of credibility. Once news broke on SolarWinds, identifying compromised sites was very difficult, even knowing the culprit update. Software Bills of Materials (SBOM) have been touted as the solution to reclaiming control of your software supply chain. Deployment of SBOMs has been slow, however, due to conflicting standards, opaque storage requirements, and vendor adoption. Additionally, the path from obtaining an SBOM and securing your supply chain is unclear; how can an SBOM library be leveraged to provide insight to your attack surface? The EyeON tool, sponsored by Department of Energy Cybersecurity, Energy Security, and Emergency Response (DoE CESER), aims to address these gaps by providing an encapsulated solution to tracking which updates have been installed in an enterprise, and alerting system administrators to vulnerabilities as they become known. Similar to a virus scanner, EyeON is a command line tool to parse either a single file, nested directory structure, or filesystem. It collects data such as signature (hashes), version information, VirusTotal tags, compiler, compilation date, and code signing information. Users will anonymously submit scan data periodically to DoE CESER, who will then compile a database of known software products employed by Critical Infrastructure and broadcast alerts based on discovered flaws as they arise.

Tenzing, Wangmo↗

Laboratory Upgrade Point Absorber (LUPA) CAD Files

The Laboratory Upgrade Point Absorber (LUPA) is an open-source wave energy converter designed and tested by Oregon State University. The computer-aided design (CAD) files are provided here in two forms: the original SOLIDWORKS (2021) model as "LUPA SOLIDWORKS.zip" and as a STEP file "LUPA-A1000.step". The bill of materials is provided as an Excel file with assemblies (LUPA-Axxx), part numbers (LUPA-Axxx-Pyyy), part descriptions, manufacturers, and manufacturer part numbers. This comprehensive CAD model represents LUPA as it was deployed in Fall 2022 testing at the O.H. Hinsdale Wave Research Laboratory. The mass properties including mass, center of gravity, and moments of inertia have been overridden for some parts and assemblies to match the physical device properties as determined from experiments. This appears as "overridden by user" when viewing mass properties in SOLIDWORKS. The LUPA-A1000.SLDASM file from the LUPA SOLIDWORKS.zip folder is the topmost assembly, open this file to see the entire model as one assembly. See "PMEC Page", "OpenEI Wiki Page", and the "Signature Project Page" resources below for more information on LUPA.

16 TIDAL AND WAVE POWER↗

Understanding and Overcoming Water-induced Interfacial Degradation in Si Modules (Final Technical Report)

Moisture ingress is an established issue for photovoltaic module durability. Durability studies probing moisture effects typically evaluate performance losses at the module level, attributing global power losses to the overall humidity condition of the test environment while leaving local module behavior unknown. This project successfully develops an in situ short-wave infrared probe of moisture content in PV modules with demonstrated detection limits better than 100 ppm in EVA-encapsulated Al-BSF and PERC architectures (66 µg/cm3) and applicability across the range of terrestrial conditions. Combining this optical moisture quantification method (water reflectometry detection, WaRD) with peel testing of interfaces, biased photoluminescence imaging of performance, and first principles computation, we correlate module moisture content and cell performance over the course of accelerated damp heat tests. By performing multi-level humidity and thermal accelerated testing over thousands of hours (0, 65 and 85% RH and 25, 65, and 85°C), we are able to attribute effects of individual environmental stresses and the dependence on module architecture. Using first-principles computational chemistry, we find that the decomposition of EVA to acetic acid (Norrish II) is thermodynamically preferred over a pathway to acetaldehyde (Norrish I), elucidating the underlying chemistry of encapsulant degradation. We also find it is likely that water segregates to the stable interfaces of the cell, especially the SiNx/EVA interface. We find that moisture is strongly correlated with reduction in adhesion at the interfaces of the cells, particularly at Ag fingers. We show uniquely that the peel strength required to delaminate the encapsulant from the front of the cell depends not only on the exposure to a high heat and humid environment, but also to the moisture content during the mechanical testing, indicating an important interaction between when mechanical stresses are faced in terms of the moisture content of the module and its durability. We find that the background sheet resistance (that is, the sheet resistance rise not attributable to finger interruptions or cracks) is substantially higher in the backsheet mini-modules vs glass-glass packages when humidity and temperature are faced. This increase in power loss due to the background resistance increase over time in damp heat in glass-backsheet modules resulted in ~3-4% larger decrease in relative PCE compared to glass-glass modules. In glass-backsheet modules, the effect of the moisture dose alone is comparable or greater than that of the combined temperature and water term, suggesting that glass-backsheet modules are overall more susceptible to moisture induced performance loss. Finally, we show that thin film PV modules are amenable to WaRD measurement, based on the ability to detect moisture in POE encapsulants or in the cell stack itself. The ease of WaRD measurement and its few requirements on the bill of materials should enable broad applicability of this technique for studying the effects of moisture in PV.

14 SOLAR ENERGY↗

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Universal Converter for DC, Single-phase AC, and Multi-phase AC Systems (Final Report)

The goal of this project was to develop a new class of universal power converters that utilize the unique properties of WBG switches, including high reverse voltage blocking and fast switching, to achieve superior performance in universal converters. Some of the features of the proposed converter are as follows: 1) Significantly longer lifetime, higher power density, lower costs associated with bill of materials, and lower shipping, installation, and repair costs compared to the existing WBG-based solutions, 2) Very flexible operation for transferring power between any type of source (dc, single-phase ac, or multi-phase ac) and any type of load (dc, single-phase ac, or multi-phase ac) without using large passive components or additional stages/components, even when the instantaneous values of input and output power are not the same, and 3) High performance operation at all power levels. Considering its advantages and wide range of applications, the proposed converter has the potential to create a new paradigm in power electronics. Among numerous applications of this converter are electric vehicles, wind energy systems, PV systems, industrial motor drives, residential variable frequency drive systems, and nanogrid applications. This project focused on the application of this converter for residential PV, residential motor drive, and industrial motor drive applications, and evaluated the performance of this converter for these applications.

42 ENGINEERING↗

Improvements in Mirror Surface Measurement with Reflected Computer Vision Targets

Over the last several years, NREL has been developing a system to measure large optical surfaces of heliostat mirrors by reflecting computer vision targets. An advantage of this system, called Reflected Target Nonintrusive Assessment (ReTNA), is that it lends itself well to stitching together many images, each reflecting only part of a larger heliostat. In the last few months, this was taken to a new extreme, with a small target (<5m2) being used to measure a >25m2 long focal length heliostat. These measurements were compared with traditional fringe deflectometry methods, which require a >50m2 target, and photogrammetry. The strengths, weaknesses and limitations of ReTNA are discussed. An estimated uncertainty in this new measurement is presented, along with software improvements and a new wireless data collection system. A bill of materials for this measurement system is presented, which has been designed to use all low-cost, off-the-shelf components. Finally, the next steps for future ReTNA development are presented. Overall, ReTNA can be a valuable optics measurement system, complimentary to existing measurement techniques available for large reflective surfaces.

14 SOLAR ENERGY↗

A stable high-humidity bubbler design to supply steam for solid oxide electrolysis cells

A stable steam supply is required for the operation of solid oxide electrolysis cells. Heated water bubblers are the most common method due to the simplicity and inherent safety of the method, however, several design challenges hinder effective implementation. Here, a stable and validated bubbler design is presented, capable of achieving very high steam concentrations, relatively high flow rates, and continuous operation. A piping and instrumentation diagram and bill of materials are provided to enable easy duplication. Critical design parameters are discussed, including safety considerations and materials requirements, which are applicable to any bubbler design. The practical implementation of bubblers is also presented, including methods to prevent condensation instability and reduce backpressure to achieve a stable steam supply. The 3″ x 6″ (7.6 cm × 15.2 cm) bubbler achieves up to 98% steam balance hydrogen at 200 sccm and up to 1 slpm at 96% steam.

08 - HYDROGEN↗

Design and evaluation of a sensor fail-operational control system for a digitally controlled turbofan engine

A self-learning, sensor fail-operational, control system for the TF30-P-3 afterburning turbofan engine was designed and evaluated. The sensor fail-operational control system includes a digital computer program designed to operate in conjunction with the standard TF30-P-3 bill-of-materials control. Four engine measurements and two compressor face measurements are tested. If any engine measurements are found to have failed, they are replaced by values synthesized from computer-stored information. The control system was evaluated by using a realtime, nonlinear, hybrid computer engine simulation at sea level static condition, at a typical cruise condition, and at several extreme flight conditions. Results indicate that the addition of such a system can improve the reliability of an engine digital control system.

Hrach, F. J.↗

Graphite fiber reinforced thermoplastic resins

The results of a program designed to optimize the fabrication procedures for graphite thermoplastic composites are described. The properties of the composites as a function of temperature were measured and graphite thermoplastic fan exit guide vanes were fabricated and tested. Three thermoplastics were included in the investigation: polysulfone, polyethersulfone, and polyarylsulfone. Type HMS graphite was used as the reinforcement. Bending fatigue tests of HMS graphite/polyethersulfone demonstrated a gradual shear failure mode which resulted in a loss of stiffness in the specimens. Preliminary curves were generated to show the loss in stiffness as a function of stress and number of cycles. Fan exit guide vanes of HMS graphite polyethersulfone were satisfactorily fabricated in the final phase of the program. These were found to have stiffness and better fatigue behavior than graphite epoxy vanes which were formerly bill of material.

Navak, R. C.↗