Assessment of BPM options for the EIC Beam Accumulator Ring

The electron injection system for the Electron-Ion Collider (EIC) at BNL is designed to provide a beam of polarized electrons, which is crucial for studying the structure of protons and atomic nuclei. The Beam Accumulator Ring (BAR) is a part of the injection chain between the 750 MeV linear accelerator and the Rapid Cycling Synchrotron (RCS), which accelerates the beam up to full energy (5–18 GeV). The functional role of the BAR is to accumulate the charge injected from the linear accelerator in order to achieve the high intensity of the polarized electron beam required by the specifications for injection into the RCS. This objective will be realized through the sequential injection of bunches with a charge of 1.1 nC at a repetition rate of 30 Hz. Once the charge of a single bunch reaches 28 nC, the beam will be extracted from the BAR and injected into the RCS. The beam instrumentation needs to provide reliable measurements with the required accuracy over the dynamic range from 0.1 nC (one tenth of a typical injected bunch charge) to 32 nC – the maximum expected accumulated current. There are 10 Beam Position Monitors (BPMs) in the ring, 1 extra button-electrode assembly for the RF system, and 8 BPMs in the beam transport lines. The BPM locations are shown in Fig. 1, marked by blue rectangles. The ring BPMs will be capable of both average orbit and turn-by-turn measurement modes. Accurate measurement of the beam position with a large horizontal offset requires polynomial correction of the BPM nonlinearity.

43 PARTICLE ACCELERATORS↗

Sub-THz passive detector performance evaluation with RadiaBeam photoinjector

Wakefield accelerators, based on THz and mm-wave structures, promise to reach the highest energies in record small footprints. However, operation at such frequencies is associated with strong generation of dipole modes that can destroy the beams, which requires controlling the electron beam position at the micron scale. The existing conventional techniques for electron beam position monitoring are not applicable for sub-THz structures due to the space constraints. Here, on the other hand, if dipole modes amplitudes can be measured precisely at different planes, one can derive beam position relative to the central axis. For such a technique a reliable and cost-effective sensor capable of operating in high repletion rate regime is required. In this paper we review the experimental evaluation of a passive sensor candidate for such applications using RadiaBeam 4.5 MeV photoinjector.

Accelerator↗

Improved Beam Loss Accounting with Fast Data Acquisition (DAQ) Chassis

Identifying the source of beam loss events in the CE-BAF accelerator can be a challenging task. However, with our new prototype system, this task becomes more effi-cient. The system, developed in the fall of 2022, utilizes a dispersive beam position monitor (BPM) and the exist-ing switched electrode electronics BPM hardware. Previ-ously a commercial off-the-shelf data acquisition (DAQ) system was employed to capture BPM wire signals at a sample rate of 20 kS/s. The fast shutdown signal triggered the system, which disables the beam at the injector. Analysis of beam position and energy variation before a beam loss event was used to determine if the beam loss event was associated with an energy transient. The proto-type system, implemented using National Instruments hardware and LabVIEW® software, relied on a software trigger. Manual post-processing was required to ascertain whether the fault was due to an un-tripped cavity with a gradient or phase transient. This work focuses on deploying a Fast DAQ Chassis to monitor BPM hardware in real time and during beam loss events. This system was originally developed and in-stalled in CEBAF to monitor the time-domain RF control signals in the legacy analog RF systems. This technology was leveraged to also monitor BPM signals. As the new system employs a hardware trigger, developing tools to automatically identify faults linked to energy transients unrelated to cavity faults will be straightforward. This paper will discuss the project's initial updates, underlin-ing the crucial role of each member of our team in this achievement

Tiskumara, J.↗

X-ray beam monitoring and wavelength calibration using four-beam diffraction

Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

Design options for a superconducting ion linac

Following a review of the design options for a superconducting ion linac, we present here an alternative design for the pre-stripper section of the superconducting driver linac for the rare isotope science project (RISP) of the Institute for Basic Science in Korea. The proposed alternative design takes advantage of the recent accelerator developments at Argonne, namely for the recent ATLAS intensity and efficiency upgrade and the Fermilab proton improvement plan project (PIP-II). In particular, the state-of-the-art performance of quarter-wave (QWRs) and half-wave resonators (HWRs), the integrated steering correctors and cold beam position monitors (BPMs) for a compact cryomodule design. In order to simplify the design and avoid frequency transitions, we used two types of QWRs at 81.25 MHz while the baseline design has QWRs at 81.25 MHz and HWRs at 162.5 MHz. The new QWR types were optimized for β ~0.05 and ~0.11, respectively, and corrected for beam steering effects. Nine cryomodules are required to reach the stripping energy of 18.5 MeV/u for uranium beam. An alternative radio-frequency quadrupole (RFQ) design was also developed. It is optimized with the multi-harmonic buncher (MHB) to produce a much smaller longitudinal emittance, offering much needed flexibility for beam tuning and more tolerance to errors. Following the lattice design optimization, end-to-end beam dynamics simulations including most important sources of machine error were performed. The results showed that the design is robust and tolerant to errors with no beam loss observed for typical machine errors.

43 PARTICLE ACCELERATORS↗

Horn Location Sensors (HLS) for LBNF

The Long-Baseline Neutrino Facility (LBNF) will deliver the world's most powerful muon neutrino beam to the Deep Underground Neutrino Experiment (DUNE), initially operating at 1.2 MW and upgradeable to 2.4 MW. Ensuring the accurate direction of this beam is critical for DUNE's precision goals. This talk introduces the Horn Location Sensors (HLS) system, designed to provide precise, relative measurements of the focusing horns, targets, and beam position monitors in the neutrino beamline. The HLS system employs high-precision FSI-based hydrostatic leveling sensors to track vertical motion and tilt, achieving precision on the order of 0.1 mm. Built for minimal maintenance in radioactive environments, the HLS system ensures precise alignment of beamline components during high-power operations. This system is essential for maintaining beam accuracy and enhancing DUNE's scientific performance.

43 PARTICLE ACCELERATORS↗

Time-of-Flight Energy Measurements With BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighbouring Beam Position Monitors (BPMs). This report discusses implementation of such a procedure at the PIP-II H- linac being constructed at Fermilab. The case when the flight time between BPMs is longer than the period of BPM frequency is considered in more detail. When absolute BPM phase calibration is not available, the BPM phase information can be used to track deviations of the beam energy from the de-sired value. Such energy deviation parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander V. [Fermilab] (ORCID:00000001↗

Time-of-Flight energy measurements with BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighboring Beam Position Monitors (BPMs). This report presents estimations on implementation of such a procedure at PIP-II H- linac being constructed at Fermilab. In part, the case when the flight time between BPMs is larger than the period of BPM frequency is considered in detail. When the absolute BPM phase calibration is not available, the BPM phase information can be used to trace deviations of the beam energy from the desired value. Such “energy deviation” parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander [Fermilab] (ORCID:00000001501↗

Improvement of the AC orbit bump method of local kick factor measurement using reference bunches

Here we have improved the AC orbit bump technique of local kick factor measurement. This technique, developed at NSLS-II a few years ago, is based on local sine-wave excitation of the electron beam by four fast correctors adjacent to the impedance location. By implementing reference bunches and the time gate function of beam position monitors, we are now able to measure the AC orbits of bunches with different intensities simultaneously. This improvement allows us to obtain the impedance-driven orbit distortion in a single measurement, significantly improving the measurement accuracy and reducing the measurement time.

36 MATERIALS SCIENCE↗

LINAC Longitudinal Simulation and Measurement of Output Energy

The Linac at Fermilab, one of the oldest accelerators on-site, plays a crucial role in delivering 400 MeV proton beams to other accelerating facilities. The beam traveling through Linac needs to be carefully monitored for better accelerator operation. One of the key factors of efficient Linac operation is its longitudinal stability. The stability can minimize Linac loss and maximize beam current. For this purpose, I examined the beam's longitudinal profile, which is crucial for proper beam transfer between its two sections. After careful monitoring of the beam through Linac, we need to ensure that it leaves with desired parameters. The beam coming out from the Linac is subsequently injected into the Booster, a synchrotron that relies on dipole magnets to bend the beam at injection. If the output energy of the beam deviates from the expected value, the beam will bend at an incorrect radius, leading to potential beam loss. Therefore, precise regulation of the output energy is critical for the efficient operation of the accelerator. To address this, I have conducted a thorough examination of the Linac longitudinal simulations and data from Beam Position Monitors (BPMs). My objective is to measure and stabilize the output energy and verify its correspondence with the predicted simulation results. All these analyses are important for efficient operation of the accelerator.

Safaryan, Milena↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗

Adaptive Machine Learning for Robust Diagnostics and Control of Time-Varying Particle Accelerator Components and Beams

Machine learning (ML) is growing in popularity for various particle accelerator applications including anomaly detection such as faulty beam position monitor or RF fault identification, for non-invasive diagnostics, and for creating surrogate models. ML methods such as neural networks (NN) are useful because they can learn input-output relationships in large complex systems based on large data sets. Once they are trained, methods such as NNs give instant predictions of complex phenomenon, which makes their use as surrogate models especially appealing for speeding up large parameter space searches which otherwise require computationally expensive simulations. However, quickly time varying systems are challenging for ML-based approaches because the actual system dynamics quickly drifts away from the description provided by any fixed data set, degrading the predictive power of any ML method, and limits their applicability for real time feedback control of quickly time-varying accelerator components and beams. In contrast to ML methods, adaptive model-independent feedback algorithms are by design robust to un-modeled changes and disturbances in dynamic systems, but are usually local in nature and susceptible to local extrema. In this work, we propose that the combination of adaptive feedback and machine learning, adaptive machine learning (AML), is a way to combine the global feature learning power of ML methods such as deep neural networks with the robustness of model-independent control. We present an overview of several ML and adaptive control methods, their strengths and limitations, and an overview of AML approaches.

97 MATHEMATICS AND COMPUTING↗

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)↗

Convergence study of wakefield simulations with GdfidL and ECHO3D

The interaction of charged particle beams with vacuum chamber components gives rise to electromagnetic wakefields, whose frequency-domain representation is known as beam coupling impedance. Geometric impedance arising from discontinuities and transitions in the vacuum chamber is the focus of this study. Minimizing this impedance is essential to mitigate adverse collective effects in modern storage rings operating with high-intensity particle beams. Accurate and reliable impedance simulations is a key factor of the vacuum chamber design. This paper presents the results of a convergence study of two widely used electromagnetic solvers, GdfidL and ECHO3D, applied to key vacuum-chamber components of the National Synchrotron Light Source II (NSLS-II) storage ring. Detailed comparisons are performed for several geometries, including flange absorbers, RF bellows, button-type beam position monitors, and an in-vacuum undulator (IVU). The results show notable differences in convergence and computational efficiency between the two codes. While GdfidL provides highly resolved results and serves as a common benchmark tool, ECHO3D yields consistent results with coarser meshes, significantly reducing simulation time and memory demands. Simulations with a full-geometry IVU model demonstrate that simplified taper-transition models can miss important impedance contributions. In conclusion, these findings provide practical guidelines for efficient and accurate impedance modeling to optimize design of vacuum chamber components for accelerators.

36 MATERIALS SCIENCE↗

Inverse modeling of circular lattices via orbit response measurements in the presence of degeneracy

The number and location of beam position monitors (BPMs) and steerers with respect to the quadrupoles in a circular lattice can lead to degeneracy in the context of fitting linear optics and extracting lattice information from measured closed orbits. Furthermore, the measurement uncertainties due to the imperfection of BPMs and steerers can be propagated by the fitting process in ways that prohibit the successful extraction of discrepancies between lattice elements in the real machine and their description in the corresponding model. We systematically studied the influence of the placement of BPMs and steerers on the reconstruction of linear optics and corresponding lattice information. The derivative of orbit response coefficients with respect to the quadrupole strengths, the Jacobian, is derived as an analytical formula. This analytical version of the Jacobian is used to further derive the theoretical limitations of fitting linear optics from closed orbits in terms of the placement of BPMs and steerers. It is further demonstrated that when evaluating the Jacobian during the fitting procedure, the analytical version can be used in place of the conventional finite-difference computation. This allows for greatly improved efficiency when computing the Jacobian during each iteration of the fitting procedure. The approach is tested with large-scale simulations and the findings are verified by measurement data taken on SIS18 synchrotron at GSI Helmholtz Centre for Heavy Ion Research. The presented methods are of general nature and can be applied to other accelerator lattices as well. The fitting procedure by using the analytical Jacobian is tested in conjunction with various methods for mitigating quasidegeneracy and the results agree with those obtained by using the conventional Jacobian via finite-difference approximation.

47 OTHER INSTRUMENTATION↗

LCLS RF Station Anomaly Candidates, SLAC, Nov 2020 to Dec 2020, Version 1

The data consists of radio-frequency (RF) station process variables (amplitude and amplitude-mean-out-of-tolerance bit) and beam position monitor (BPM) values for about a month of Linac Coherent Light Source (LCLS) time. The data is all from normal conducting hard X-ray operation. The dataset contains roughly 5000 anomaly “candidates.” For each candidate, we include 3.5 minutes of data from the 82 RF stations and ~20 seconds of data from 4 BPMs. We also include several CSV files with additional information and labels for each candidate.

43 PARTICLE ACCELERATORS↗