Engineering PapersSearch

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Plasma heating, electric fields and plasma flow by electron beam ionospheric injection

The electric fields and the floating potentials of a Plasma Diagnostics Payload (PDP) located near a powerful electron beam injected from a large sounding rocket into the auroral zone ionosphere have been studied. As the PDP drifted away from the beam laterally, it surveyed a region of hot plasma extending nearly to 60 m radius. Large polarization electric fields transverse to B were imbedded in this hot plasma, which displayed large ELF wave variations and also an average pattern which has led to a model of the plasma flow about the negative line potential of the beam resembling a hydrodynamic vortex in a uniform flow field. Most of the present results are derived from the ECHO 6 sounding rocket mission.

Winckler, J. R.

Whistler-mode radiation from the Spacelab 2 electron beam

During the Spacelab 2 mission the Plasma Diagnostics Package (PDP) performed a fly-around of the Shuttle at distances of up to 300 meters while an electron beam was being ejected from the Shuttle. A magnetic conjunction of the Shuttle and the PDP while the electron gun was operating in a steady (DC) mode is discussed. During this conjunction, the PDP detected a clear funnel-shaped emission that is believed to be caused by whistler-mode emission from the beam. Ray-path calculations show that the shape of the funnel can be accounted for by whistler-mode waves propagating near the resonance cone. Because the beam and waves are propagating in the same direction, the radiation must be produced by a Landau interaction with the beam. Other types of waves generated by the beam are also described.

Gurnett, D. A.

Artificial electron beams in the magnetosphere and ionosphere

The Plasma Diagnostics Payload of the Echo 7 satellite carried TV cameras and photometers by means of which the luminosity around an electron beam in the polar ionosphere could be studied. It was found that, while the beam Larmor spiral could be clearly seen near 100 km, above this only a column due to suprathermal electrons was observable. At high altitudes, the emission of neutral gas both generated powerful luminosity and substantially reduced accelerator potentials. An analysis of conjugate echoes indicates that inferred magnetospheric electric fields do not map well into the ionosphere, as well as the presence of strong pitch-angle scattering.

Winckler, John R.

Energy transport and dynamics

We report findings concerning energy transport and dynamics in flares during the impulsive and gradual phases based on new ground-based and space observations (notably from Yohkoh). A preheating sometimes occurs during the impulsive phase. Ca XIX line shifts are confirmed to be good tracers of bulk plasma motions, although strong blue shifts are not as frequent as previously claimed. They often appear correlated with hard X-rays but, for some events, the concept that electron beams provide the whole energy input to the thermal component seems not to apply. Theory now yields: new diagnostics of low-energy proton and electric beams; accurate hydrodynamical modeling of pulse beam heating of the atmosphere; possible diagnostics of microflares (based on X-ray line ratio or on loop variability); and simulated images of chromospheric evaporation fronts. For the gradual phase, the continual reorganization of magnetic field lines over active regions determines where and when magnetic reconnection, the mechanism favored for energy release, will occur. Spatial and temporal fragmentation of the energy release, observed at different wavelengths, is considered to be a factor as well in energy transport and plasma dynamics.

Schmieder, Brigitte

Pulsed electron beam emission in space

During the Spacelab-2 mission of July 1985, electron beams (1 keV, 50-150 mA) pulsed at ELF and VLF frequencies were emitted from the Space Shuttle Orbiter. The wave fields generated by the beam were monitored by a Plasma Diagnostics Package which was released as a free-flying subsatellite during a six hour period. Measurements of the Orbiter potential and the return current during beam emissions were obtained from a Charge and Current Probe mounted in the payload bay.

Neubert, T.

An analysis of whistler mode radiation from the Spacelab 2 electron beam

During the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the Shuttle to free fly. At times during this free flight, when the PDP was magnetically connected to the Shuttle, Stanford's fast-pulsed electron generator, located in the Shuttle cargo bay, ejected a 1-keV 50-mA electron beam. The PDP plasma-wave instrument detected intense whistler-mode radiation during these beam ejections. This paper presents a study of a whistler mode emission detected during one particular continuous electron beam firing. Calculations indicate that the beam radiated approximately 1.6 mW in the whistler mode as the beam traversed the 200 m from the Shuttle to the PDP. The emissivity also decreased by about a factor of 10 over this same distance. The measured wave powers are 10 to the 7th greater than wave powers expected from incoherent Cerenkov radiation, verifying that the radiation is generated by a coherent process. Estimates of the emissivity based on measured electric field intensities in the beam indicate that the whistler-mode noise is produced by radiation from electron bunches created by an electrostatic beam-plasma instability.

Farrell, W. M.

High resolution X-ray optics for astronomical and laboratory sources

In recent years X-ray telescopes have been used successfully for high resolution observations of astronomical objects, in particular the solar corona. At the present time X-ray microscopes are being developed for diagnostics of laser and electron beam induced fusion plasmas. This paper describes both types of imaging systems using as examples the AS&E X-ray telescope on Skylab and a 10X microscope being built for Los Alamos Scientific Laboratories. The designs, manufacturing tolerances, fabrication, testing, and performance are discussed. Steps for further development in both imaging areas are identified.

Silk, J. K.

Unsteady turbulent shear flow in shock tube discontinuities

A pressure-ruptured shock tube and an arc driven shock tube, have been used to study the evolution of turbulent fluctuations at contact surfaces with N2O4-2NO2 mixtures and at ionizing shock fronts in argon. The study has focused on point density diagnostics derived from crossed light beam correlations and electric probes. Turbulent bursts are found for which dynamical and spectral analyses suggest a particle-like evolution of fluctuation segments with a unique and characteristic frequency, independent of flow history and overall flow conditions.

Johnson, J. A., III

High-frequency instability of the sheath-plasma resonance

Coherent high frequency oscillations near the electron plasma frequency (omega approx. less than omega sub p) are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diode-like electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening and copious harmonics. The fundamental instability is a bounded oscillation due to wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres) which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line broadening mechanism was identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burst-like RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.

Stenzel, R. L.

High-frequency instability of the sheath-plasma resonance

Coherent high-frequency oscillations near the electron plasma frequency are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diodelike electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening, and copious harmonics. The fundamental instability is a bounded oscillation caused by wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres), which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line-broadening mechanism has been identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burstlike RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.

Stenzel, R. L.

Time dependency of temperature of a laser-irradiated infrared target pixel as a low-pass filter

The thermal response of a surface layer of a pixel on an infrared target simulator is discussed. This pixel is maintained at a constant temperature by a rapidly scanning laser beam. An analytical model has been developed to describe the exact temperature dependence of a pixel as a function of time for different pixel refresh rates. The top layer of the pixel surface that generates the gray-body radiation shows the temperature dependence on time that is characteristic of a low-pass filter. The experimental results agree with the analytical predictions. The application of a pulsed laser beam to a noncontact, nondestructive diagnostic technique of surface characterization for the presence of microdefects is discussed.

Scholl, Marija S.

Non-Intrusive Optical Diagnostic Methods for Flowfield Characterization

Non-intrusive optical diagnostic techniques such as Electron Beam Fluorescence (EBF), Laser-Induced Fluorescence (LIF), and Focusing Schlieren (FS) have been setup for high-speed flow characterization and large flowfield visualization, respectively. Fluorescence emission from the First Negative band of N2(+) with the (0,0) vibration transition (at lambda =391.44 nm) was obtained using the EBF technique and a quenching rate of N2(+)* molecules by argon gas was reported. A very high sensitivity FS system was built and applied in the High-Speed Flow Generator (HFG) at NASA LaRC. A LIF system is available at the Advanced Propulsion Laboratory (APL) on campus and a plume exhaust velocity measurement, measuring the Doppler shift from lambda = 728.7 nm of argon gas, is under way.

Tabibi, Bagher M.

Review of the High Performance Antiproton Trap (HiPAT) Experiment

Many space propulsion concepts exist that use matter-antimatter reactions. Current antiproton production rates are enough to conduct proof-of-principle evaluation of these concepts. One enabling technology for such experiments is portable storage of low energy antiprotons, to transport antiprotons to experimental facilities. To address this need, HiPAT is being developed, with a design goal of containing 10(exp 12) particles for up to 18 days. HiPAT is a Penning-Malmberg trap with a 4 Tesla superconductor, 20kV electrodes, radio frequency (RF) network, and 10(exp -13) Torr vacuum. 'Normal' matter is being used to evaluate the system. An electron beam ionizes background gas in situ, and particle beams are captured dynamically. The experiment examines ion storage lifetimes, RF plasma diagnostics, charge exchange with background gases, and dynamic ion beam capture.

Martin, James J.

AMPAS - A new active experiment mission

A new concept for an active experiments mission is presented: The Active Magnetospheric Particle Acceleration Satellite (AMPAS). It is proposed to fly a dual-payload tethered satellite to study three important areas of magnetopsheric physics: (1) electric and magnetic field structures of the Earth's magnetosphere, (2) electron beam-plasma interactions, and (3) far ultraviolet (FUV) signatures of energetic electron precipitation. The tethered system is to be flown in a gravity-gradient stabilized configuration with a 70 deg circular orbit at altitudes in the range 300-800 km. The upper payload will carry two electron beam accelerators (1-10 keV, 1 A) and a plasma contractor to electrically neutralize the payload, while the lower will carry a complement of optical imaging and plasma diagonstics instrumentation. Upward directed beams are injected to 'sound' electric and magnetic field structures, including parallel electric fields in the auroral region, while simultaneous optical instruments aimed downwards measure characteristics of reflected beam pulses precipitating into the upper atmosphere below the satellite. Downward directed beams, and simultaneous plasma wave, particle and optical measurements, are used for the investigation of beam-plasma interactions and electron precipitation studies. The payloads are to be connected by a 1-6 km long tether to be deployed in stages. The configuration of the beam source and the plasma and optical diagnostics on separate, tethered payloads allows the diagnostics to be performed outside of the disturbed region around the source payload, and plasma wave and particle observations of beam-plasma interactions to be performed at well-defined locations relative to the source.

Neubert, T.

Electromagnetic-wave excitation in a large laboratory beam-plasma system

The mechanism by which unstable electrostatic waves of a beam-plasma system are converted into observed electromagnetic waves is of current interest in space physics and in tokamak fusion research. The process involved in the conversion of electrostatic to electromagnetic waves at the critical layer is well understood. However, the radiation from uniform plasmas cannot be explained on the basis of this process. In connection with certain difficulties, it has not yet been possible to establish the involved emission processes by means of experimental observations. In the considered investigation these difficulties are overcome by employing a large laboratory plasma in a parameter range suitable for detailed diagnostics. A finite-diameter electron beam is injected into a uniform quiescent afterglow plasma of dimensions large compared with electromagnetic wavelengths. The considered generation mechanism concerning the electromagnetic waves is conclusively confirmed by observing the temporal evolution of an instability

Whelan, D. A.

Numerical simulations of impulsively heated solar flares

The response of a model solar atmosphere to heating by an electron beam has been studied for electron beam flux spectra which are power laws with low-energy 'knees' (rising linearly with time to a peak at 30 s and then falling linearly to 0 at 60 s) ranging from 10 to 20 keV. The results indicate that high peak electron beam fluxes, low-energy knees, and larger spectral indices all move the atmospheric response toward greater enhancements of the parameters in the coronal regions of the atmosphere. Coronal responses can thus be used as a diagnostic of the parameters of the electron beam.

Mariska, John T.

Double-probe potential measurements near the Spacelab 2 electron beam

As part of the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the shuttle as a free-flying satellite. The PDP carried a quasi-static electric field instrument which made differential voltage measurements between two floating probes. At various times during the free flight, an electron beam was ejected from the shuttle. Large differential voltages between the double probes were recorded in association with the electron beam. However, analysis indicates that these large signals are probably not caused by ambient electric fields. Instead, they can be explained by considering three effects: shadowing of the probes from streaming electrons by the PDP chassis, crossing of the PDP wake by the probes, and spatial gradients in the fluxes of energetic electrons reaching the probes. Plasma measurements on the PDP show that energetic electrons exist in a region 20 m wide and up to at least 170 m downstream from the electron beam. At 80 or more meters downstream from the beam, the double probe measurements show that the energetic electron flux is opposite to the injection direction, as would be expected for a secondary returning electron beam produced by scattering of the primary electron beam.

Steinberg, J. T.

Experimental studies of an ECR plasma thruster

The Electron Cyclotron Resonance (ECR) thruster is a proposed electrodeless space electric propulsion device with interesting and little understood physics. A laboratory ECR thruster was run in a vacuum tank at pressures in the 10 exp -5 torr range using 2.12 GHz microwave beam and Ar gas propellant. Movable diagnostic probes (a Faraday cup and a gridded energy analyzer) measured plasma characteristics as propellant gas flow rate and input microwave power level were varied. Ion energy and flux data were used to calculate I(sp), propulsive efficiency, and thrust. The ion flux profiles show an unexpected depression on the thruster axis for low tank pressures that disappears as the tank pressure increases. Ion energies decrease as the flow rate and pressure increase, but the microwave power level affects the energy only negligibly. The calculated propulsion parameters demonstrate that the efficiency of the laboratory device is low, and that tank pressure greatly changes the performance.

Kaufman, D. A.