Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dose reduction using a dynamic, piecewise-linear attenuator

Purpose: The authors recently proposed a dynamic, prepatient x-ray attenuator capable of producing a piecewise-linear attenuation profile customized to each patient and viewing angle. This attenuator was intended to reduce scatter-to-primary ratio (SPR), dynamic range, and dose by redistributing flux. In this work the authors tested the ability of the attenuator to reduce dose and SPR in simulations. Methods: The authors selected four clinical applications, including routine full field-of-view scans of the thorax and abdomen, and targeted reconstruction tasks for an abdominal aortic aneurysm and the pancreas. Raw data were estimated by forward projection of the image volume datasets. The dynamic attenuator was controlled to reduce dose while maintaining peak variance by solving a convex optimization problem, assuminga priori knowledge of the patient anatomy. In targeted reconstruction tasks, the noise in specific regions was given increased weighting. A system with a standard attenuator (or “bowtie filter”) was used as a reference, and used either convex optimized tube current modulation (TCM) or a standard TCM heuristic. The noise of the scan was determined analytically while the dose was estimated using Monte Carlo simulations. Scatter was also estimated using Monte Carlo simulations. The sensitivity of the dynamic attenuator to patient centering was also examined by shifting the abdomen in 2 cm intervals. Results: Compared to a reference system with optimized TCM, use of the dynamic attenuator reduced dose by about 30% in routine scans and 50% in targeted scans. Compared to the TCM heuristics which are typically used withouta priori knowledge, the dose reduction is about 50% for routine scans. The dynamic attenuator gives the ability to redistribute noise and variance and produces more uniform noise profiles than systems with a conventional bowtie filter. The SPR was also modestly reduced by 10% in the thorax and 24% in the abdomen. Imaging with the dynamic attenuator was relatively insensitive to patient centering, showing a 17% increase in peak variance for a 6 cm shift of the abdomen, instead of an 82% increase in peak variance for a fixed bowtie filter. Conclusions: A dynamic prepatient x-ray attenuator consisting of multiple wedges is capable of achieving substantial dose reductions and modest SPR reductions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Methods of Attenuation Correction for Dual-Wavelength and Dual-Polarization Weather Radar Data

In writing the integral equations for the median mass diameter and number concentration, or comparable parameters of the raindrop size distribution, it is apparent that the forms of the equations for dual-polarization and dual-wavelength radar data are identical when attenuation effects are included. The differential backscattering and extinction coefficients appear in both sets of equations: for the dual-polarization equations, the differences are taken with respect to polarization at a fixed frequency while for the dual-wavelength equations, the differences are taken with respect to frequency at a fixed polarization. An alternative to the integral equation formulation is that based on the k-Z (attenuation coefficient-radar reflectivity factor) parameterization. This-technique was originally developed for attenuating single-wavelength radars, a variation of which has been applied to the TRMM Precipitation Radar data (PR). Extensions of this method have also been applied to dual-polarization data. In fact, it is not difficult to show that nearly identical equations are applicable as well to dualwavelength radar data. In this case, the equations for median mass diameter and number concentration take the form of coupled, but non-integral equations. Differences between this and the integral equation formulation are a consequence of the different ways in which attenuation correction is performed under the two formulations. For both techniques, the equations can be solved either forward from the radar outward or backward from the final range gate toward the radar. Although the forward-going solutions tend to be unstable as the attenuation out to the range of interest becomes large in some sense, an independent estimate of path attenuation is not required. This is analogous to the case of an attenuating single-wavelength radar where the forward solution to the Hitschfeld-Bordan equation becomes unstable as the attenuation increases. To circumvent this problem, the equations can be expressed in the form of a final-value problem so that the recursion begins at the far range gate and proceeds inward towards the radar. Solving the problem in this way traditionally requires estimates of path attenuation to the final gate: in the case of orthogonal linear polarizations, the attenuations at horizontal and vertical polarizations (same frequency) are required while in the dual-wavelength case, attenuations at the two frequencies (same polarization) are required.

Meneghini, R.↗

Improved Chemistry and Attenuation Models for Communication Blackout Simulation During Mars 2020 Entry

As a blunt body enters a planetary atmosphere, a plasma forms in the hypersonic shock layer and attenuates radio communication causing signal blackout for some duration of the entry sequence. In our previous work,1 computational fluid dynamics (CFD) was applied to model the entry flow around the Mars 2020 spacecraft, including ionization and electron density throughout the flow field, and predict ultra-high frequency (UHF) radio wave attenuation due to electrons. In total, 17 chemical species and their spatial profiles are modelled around the Mars 2020 spacecraft at 11 different points in time during entry. Although the simulation predicted the onset of attenuation well, the timing of the end of the predicted blackout window significantly preceded the end time observed during the 2021 landing. The present work seeks to improve the attenuation model by accounting for the fact that electrons undergo collisions with heavier species in the flow, which is an effect that was neglected in previous analyses. It is determined that including electron collisions increases the overall magnitude of attenuation predicted especially towards the end of the measured attenuation period, improving qualitative agreement between predicted and measured attenuation to both spacecraft receiving the signal from Mars 2020. To explore the remaining uncertainty in signal attenuation predictions further, a sensitivity study is performed to investigate the impact of associative ionization and electron-impact ionization rate coefficients on the electron density predicted by CFD and on the resulting attenuation predictions. These coefficients are believed to contain up to order-of-magnitude uncertainty, and therefore may significantly affect the number density of electrons throughout the flow field. Variations in associative ionization coefficients demonstrate significant impact on the magnitude of attenuation due to variation in the electron density coming from associative ionization. However, the start and end times of the predicted signal attenuation period are only slightly impacted by said variation.

Eve Papajak↗

Improved Chemistry and Attenuation Models for Communication Blackout Simulation During Mars 2020 Entry

As a blunt body enters a planetary atmosphere, a plasma forms in the hypersonic shock layer and attenuates radio communication causing signal blackout for some duration of the entry sequence. In our previous work,1 computational fluid dynamics (CFD) was applied to model the entry flow around the Mars 2020 spacecraft, including ionization and electron density throughout the flow field, and predict ultra-high frequency (UHF) radio wave attenuation due to electrons. In total, 17 chemical species and their spatial profiles are modelled around the Mars 2020 spacecraft at 11 different points in time during entry. Although the simulation predicted the onset of attenuation well, the timing of the end of the predicted blackout window significantly preceded the end time observed during the 2021 landing. The present work seeks to improve the attenuation model by accounting for the fact that electrons undergo collisions with heavier species in the flow, which is an effect that was neglected in previous analyses. It is determined that including electron collisions increases the overall magnitude of attenuation predicted especially towards the end of the measured attenuation period, improving qualitative agreement between predicted and measured attenuation to both spacecraft receiving the signal from Mars 2020. To explore the remaining uncertainty in signal attenuation predictions further, a sensitivity study is performed to investigate the impact of associative ionization and electron-impact ionization rate coefficients on the electron density predicted by CFD and on the resulting attenuation predictions. These coefficients are believed to contain up to order-of-magnitude uncertainty, and therefore may significantly affect the number density of electrons throughout the flow field. Variations in associative ionization coefficients demonstrate significant impact on the magnitude of attenuation due to variation in the electron density coming from associative ionization. However, the start and end times of the predicted signal attenuation period are only slightly impacted by said variation.

Eve Papajak↗

Patient position alters attenuation effects in multipinhole cardiac SPECT

Purpose: Dedicated cardiac cameras offer improved sensitivity over conventional SPECT cameras. Sensitivity gains are obtained by large numbers of detectors and novel collimator arrangements such as an array of multiple pinholes that focus on the heart. Pinholes lead to variable amounts of attenuation as a source is moved within the camera field of view. This study evaluated the effects of this variable attenuation on myocardial SPECT images. Methods: Computer simulations were performed for a set of nine point sources distributed in the left ventricular wall (LV). Sources were placed at the location of the heart in both an anthropomorphic and a water-cylinder computer phantom. Sources were translated in x, y, and z by up to 5 cm from the center. Projections were simulated with and without attenuation and the changes in attenuation were compared. A LV with an inferior wall defect was also simulated in both phantoms over the same range of positions. Real camera data were acquired on a Discovery NM530c camera (GE Healthcare, Haifa, Israel) for five min in list-mode using an anthropomorphic phantom (DataSpectrum, Durham, NC) with 100 MBq of Tc-99m in the LV. Images were taken over the same range of positions as the simulations and were compared based on the summed perfusion score (SPS), defect width, and apparent defect uptake for each position. Results: Point sources in the water phantom showed absolute changes in attenuation of ≤8% over the range of positions and relative changes of ≤5% compared to the apex. In the anthropomorphic computer simulations, absolute change increased to 20%. The changes in relative attenuation caused a change in SPS of <1.5 for the water phantom but up to 4.2 in the anthropomorphic phantom. Changes were larger for axial than for transverse translations. These results were supported by SPS changes of up to six seen in the physical anthropomorphic phantom for axial translations. Defect width was also seen to significantly increase. The position-dependent changes were removed with attenuation correction. Conclusions: Translation of a source relative to a multipinhole camera caused only small changes in homogeneous phantoms with SPS changing <1.5. Inhomogeneous attenuating media cause much larger changes to occur when the source is translated. Changes in SPS of up to six were seen in an anthropomorphic phantom for axial translations. Attenuation correction removes the position-dependent changes in attenuation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-107: An Investigation Into Attenuation Effects On the Energy Spectrum for {sup 137}Cs Using Monte Carlo Techniques

Purpose: The calibration of radiation protection instrumentation including ionization chambers, scintillators, and Geiger Mueller (GM) counters used as survey meters are often done using {sup 137}Cs irradiators. During calibration, irradiators use a combination of attenuators with various thicknesses to modulate the beam to a known air-kerma rate. The variations in energy spectra as a result of these attenuators are not accounted for and may play a role in the energy-dependent response of survey meters. This study uses an experimentally validated irradiator geometry modeled in the MCNP5 transport code to characterize the effects of attenuation on the energy spectrum. Methods: A Hopewell Designs G-10 {sup 137}Cs irradiator with lead attenuators of thicknesses of 0.635, 1.22, 2.22, and 4.32 cm, was used in this study. The irradiator geometry was modeled in MCNP5 and validated by comparing measured and simulated percent depth dose (PDD) and cross-field profiles. Variations in MCNP5 simulated spectra with increasing amounts of attenuation were characterized using the relative intensity of the 662 keV peak and the average energy. Results: Simulated and measured PDDs and profiles agreed within the associated uncertainty. The relative intensity of the 662 keV peak for simulated spectra normalized to the intensity of the unattenuated spectra ranged from 0.16% to 100% based on attenuation thickness. The average energy for simulated spectra for attenuators ranged from 582 keV with no attenuation to 653 keV with 5.54 cm of attenuation. Statistical uncertainty for MCNP5 simulations ranged from 0.11% to 3.69%. Conclusion: This study successfully used MCNP5 to validate a {sup 137}Cs irradiator geometry and characterize variations in energy spectra between different amounts of attenuation. Variations in the average energy of up to 12% were determined through simulations, and future work will aim to determine the effects of these differences on survey meter response and calibration.

07 ISOTOPE AND RADIATION SOURCES↗

Improving Earthquake-Explosion Discrimination using Attenuation Models of the Crust and Upper Mantle

In the past year, we have made significant progress on developing and calibrating methodologies to improve earthquake-explosion discrimination using high-frequency regional P/S amplitude ratios. Closely-spaced earthquakes and explosions generally discriminate easily using this method, as demonstrated by recordings of explosions from test sites around the world. In relatively simple geophysical regions such as the continental parts of the Yellow Sea and Korean Peninsula (YSKP) we have successfully used a 1-D Magnitude and Distance Amplitude Correction methodology (1-D MDAC) to extend the regional P/S technique over large areas. However in tectonically complex regions such as the Middle East, or the mixed oceanic-continental paths for the YSKP the lateral variations in amplitudes are not well predicted by 1-D corrections and 1-D MDAC P/S discrimination over broad areas can perform poorly. We have developed a new technique to map 2-D attenuation structure in the crust and upper mantle. We retain the MDAC source model and geometrical spreading formulation and use the amplitudes of the four primary regional phases (Pn, Pg, Sn, Lg), to develop a simultaneous multi-phase approach to determine the P-wave and S-wave attenuation of the lithosphere. The methodology allows solving for attenuation structure in different depth layers. Here we show results for the P and S-wave attenuation in crust and upper mantle layers. When applied to the Middle East, we find variations in the attenuation quality factor Q that are consistent with the complex tectonics of the region. For example, provinces along the tectonically-active Tethys collision zone (e.g. Turkish Plateau, Zagros) have high attenuation in both the crust and upper mantle, while the stable outlying regions like the Indian Shield generally have low attenuation. In the Arabian Shield, however, we find that the low attenuation in this Precambrian crust is underlain by a high-attenuation upper mantle similar to the nearby Red Sea Rift. Applying this 2-D MDAC methodology with the new attenuation models can significantly improve earthquake-explosion discrimination using regional P/S amplitude ratios. We demonstrate applications of this technique, including a study at station NIL (Nilore, Pakistan) using broad area earthquakes and the 1998 Indian nuclear explosion using a number of regional amplitude ratio discriminants. We are currently applying the technique in the YSKP region as well.

58 GEOSCIENCES↗

Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities

Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve the quantitative accuracy of these emerging hybrid imaging systems. The attenuation map in PET/MRI should ideally be derived from anatomical MR images; however, MRI intensities reflect proton density and relaxation time properties of biological tissues rather than their electron density and photon attenuation properties. Therefore, in contrast to PET/computed tomography, there is a lack of standardized global mapping between the intensities of MRI signal and linear attenuation coefficients at 511 keV. Moreover, in standard MRI sequences, bones and lung tissues do not produce measurable signals owing to their low proton density and short transverse relaxation times. MR images are also inevitably subject to artifacts that degrade their quality, thus compromising their applicability for the task of attenuation correction in PET/MRI. MRI-guided attenuation correction strategies can be classified in three broad categories: (i) segmentation-based approaches, (ii) atlas-registration and machine learning methods, and (iii) emission/transmission-based approaches. This paper summarizes past and current state-of-the-art developments and latest advances in PET/MRI attenuation correction. The advantages and drawbacks of each approach for addressing the challenges of MR-based attenuation correction are comprehensively described. The opportunities brought by both MRI and PET imaging modalities for deriving accurate attenuation maps and improving PET quantification will be elaborated. Future prospects and potential clinical applications of these techniques and their integration in commercial systems will also be discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatiotemporal changes of seismic attenuation caused by injected CO 2 at the Frio-II pilot site, Dayton, TX, USA

A continuous active source seismic monitoring data set was collected with crosswell geometry during CO 2 injection at the Frio-II brine pilot, near Liberty, TX. Previous studies have shown that spatiotemporal changes in the P wave first arrival time reveal the movement of the injected CO 2 plume in the storage zone. To further constrain the CO 2 saturation, particularly at higher saturation levels, we investigate spatial-temporal changes in the seismic attenuation of the first arrivals. The attenuation changes over the injection period are estimated by the amount of the centroid frequency shift computed by local time-frequency analysis. We observe that (1) at receivers above the injection zone seismic attenuation does not change in a physical trend; (2) at receivers in the injection zone attenuation sharply increases following injection and peaks at specific points varying with distributed receivers, which is consistent with observations from time delays of first arrivals; then, (3) attenuation decreases over the injection time. The attenuation change exhibits a bell-shaped pattern during CO 2 injection. Under Frio-II field reservoir conditions, White's patchy saturation model can quantitatively explain both the P wave velocity and attenuation response observed. We have combined the velocity and attenuation change data in a crossplot format that is useful for model-data comparison and determining patch size. Our analysis suggests that spatial-temporal attenuation change is not only an indicator of the movement and saturation of CO 2 plumes, even at large saturations, but also can quantitatively constrain CO 2 plume saturation when used jointly with seismic velocity.

58 GEOSCIENCES↗

Preparation, characterization and millimetre wave attenuation performance of carbon fibers coated with nickel-wolfram-phosphorus and nickel-cobalt-wolfram- phosphorus

Highlights: • SEM, XRD, EDS and MMW attenuation performances of alloys coated CFs were studied. • Resistivity and P content in alloys were main factors on MMW attenuation property. • The weight gain of coated CFs has effects on the MMW attenuation performance. - Abstract: Carbon fibers (CFs) coated with Ni–X–P (X = W, Co–W or none) alloys were prepared by electroless plating. The morphology, crystal structure, and element composition of alloy-coated CFs were characterized by scanning electron microscopy, X-ray diffractometry, energy-dispersive spectrometry and microwave attenuation. The results showed that CFs were coated with a layer of alloy particles. P content in Ni–Co–W–P or Ni–W–P alloys was lower than that in Ni–P alloy, and coating alloy Ni–P was amorphous. After W or Co introduction, coating alloys exhibited crystal characteristics. MMW-attenuation performance analysis showed that the 3 mm wave attenuation performance of CFs/Ni–Co–W–P, CFs/Ni–W–P and CFs/Ni–P increased by 7.27 dBm, 4.88 dBm and 3.55 dBm, and the 8 mm wave attenuation effects increased by 11.61 dBm, 6.11 dBm, and 4.06 dBm respectively, compared with those of CFs. MMW-attenuation performance is attributable to the sample bulk resistivity and P content in the alloy. Moreover, an optimal weight gain value existed for the MMW-attenuation performance of alloy-coated CFs.

36 MATERIALS SCIENCE↗

Hsp90 inhibitor geldanamycin attenuates the cytotoxicity of sunitinib in cardiomyocytes via inhibition of the autophagy pathway

Sunitinib malate (sunitinib) is an orally available, multitargeted tyrosine kinase inhibitor with antitumor and antiangiogenic activities. Although sunitinib is effective for the treatment of patients with gastrointestinal stromal tumor, advanced renal cell carcinoma, or pancreatic neuroendocrine tumor, adverse cardiac events associated with sunitinib administration have been reported. Here, we examined the effect of geldanamycin, an inhibitor of heat shock protein (Hsp) 90, on sunitinib-induced cytotoxicity in cardiomyocytes. First, we found that treatment with geldanamycin or other Hsp90 inhibitors (tanespimycin, ganetespib, or BIIB021) significantly attenuated sunitinib-induced cytotoxicity in rat H9c2 cardiomyocytes, suggesting a drug-class effect of Hsp90 inhibitors. We then examined the mechanisms underlying sunitinib-induced cytotoxicity and found that sunitinib induced autophagy in H9c2 cells and that pretreatment with geldanamycin inhibited the induction of autophagy by promoting degradation of the autophagy-related proteins Atg7, Beclin-1, and ULK1. Pharmacological assessment with autophagy inhibitors confirmed that geldanamycin attenuated the cytotoxicity of sunitinib by interfering with autophagy. In addition, we found that the molecular chaperone Hsp70, which is induced by geldanamycin, was not involved in the attenuation of sunitinib-induced cytotoxicity. Finally, to provide more clinically relevant data, we confirmed that geldanamycin attenuated sunitinib-induced cytotoxicity in human induced pluripotent stem cell-derived cardiomyocytes. Together, these data suggest that geldanamycin attenuates sunitinib-induced cytotoxicity in cardiomyocytes by inhibiting the autophagy pathway. Thus, the further investigation of combination or sequential treatment with an Hsp90 inhibitor and sunitinib is warranted as a potential strategy of attenuating the cardiotoxicity associated with sunitinib administration in the clinical setting. - Highlights: • Hsp90 inhibitors attenuated sunitinib-induced cytotoxicity in cardiomyocytes. • Sunitinib induced autophagic flux in cardiomyocytes. • Geldanamycin degraded autophagy regulator proteins in cardiomyocytes. • Inhibition of the autophagy pathway attenuated sunitinib-induced cardiotoxicity. • Hsp70 induction was not involved in attenuating sunitinib-induced cardiotoxicity.

60 APPLIED LIFE SCIENCES↗

Correction of quantification errors in pelvic and spinal lesions caused by ignoring higher photon attenuation of bone in [{sup 18}F]NaF PET/MR

Purpose: MR-based attenuation correction (MRAC) in routine clinical whole-body positron emission tomography and magnetic resonance imaging (PET/MRI) is based on tissue type segmentation. Due to lack of MR signal in cortical bone and the varying signal of spongeous bone, standard whole-body segmentation-based MRAC ignores the higher attenuation of bone compared to the one of soft tissue (MRAC{sub nobone}). The authors aim to quantify and reduce the bias introduced by MRAC{sub nobone} in the standard uptake value (SUV) of spinal and pelvic lesions in 20 PET/MRI examinations with [{sup 18}F]NaF. Methods: The authors reconstructed 20 PET/MR [{sup 18}F]NaF patient data sets acquired with a Philips Ingenuity TF PET/MRI. The PET raw data were reconstructed with two different attenuation images. First, the authors used the vendor-provided MRAC algorithm that ignores the higher attenuation of bone to reconstruct PET{sub nobone}. Second, the authors used a threshold-based algorithm developed in their group to automatically segment bone structures in the [{sup 18}F]NaF PET images. Subsequently, an attenuation coefficient of 0.11 cm{sup −1} was assigned to the segmented bone regions in the MRI-based attenuation image (MRAC{sub bone}) which was used to reconstruct PET{sub bone}. The automatic bone segmentation algorithm was validated in six PET/CT [{sup 18}F]NaF examinations. Relative SUV{sub mean} and SUV{sub max} differences between PET{sub bone} and PET{sub nobone} of 8 pelvic and 41 spinal lesions, and of other regions such as lung, liver, and bladder, were calculated. By varying the assigned bone attenuation coefficient from 0.11 to 0.13 cm{sup −1}, the authors investigated its influence on the reconstructed SUVs of the lesions. Results: The comparison of [{sup 18}F]NaF-based and CT-based bone segmentation in the six PET/CT patients showed a Dice similarity of 0.7 with a true positive rate of 0.72 and a false discovery rate of 0.33. The [{sup 18}F]NaF-based bone segmentation worked well in the pelvis and spine. However, it showed artifacts in the skull and in the extremities. The analysis of the 20 [{sup 18}F]NaF PET/MRI examinations revealed relative SUV{sub max} differences between PET{sub nobone} and PET{sub bone} of (−8.8% ± 2.7%, p = 0.01) and (−8.1% ± 1.9%, p = 2.4 × 10{sup −8}) in pelvic and spinal lesions, respectively. A maximum SUV{sub max} underestimation of −13.7% was found in lesion in the third cervical spine. The averaged SUV{sub mean} differences in volumes of interests in lung, liver, and bladder were below 3%. The average SUV{sub max} differences in pelvic and spinal lesions increased from −9% to −18% and −8% to −17%, respectively, when increasing the assigned bone attenuation coefficient from 0.11 to 0.13 cm{sup −1}. Conclusions: The developed automatic [{sup 18}F]NaF PET-based bone segmentation allows to include higher bone attenuation in whole-body MRAC and thus improves quantification accuracy for pelvic and spinal lesions in [{sup 18}F]NaF PET/MRI examinations. In nonbone structures (e.g., lung, liver, and bladder), MRAC{sub nobone} yields clinically acceptable accuracy.

60 APPLIED LIFE SCIENCES↗

Importance of Considering Near-Surface Attenuation in Earthquake Source Parameter Estimation: Insights from Kappa at a Dense Array in Oklahoma

ABSTRACT Separating earthquake source spectra from propagation effects is challenging. The propagation effect contains a site-dependent term related to the high attenuation of shallow sediments. Neglecting the site-dependent attenuation can cause large biases and scattering in the corner-frequency (fc) estimates, resulting in significant stress-drop deviations. In this study, we investigate shallow attenuation at the LArge-n Seismic Survey in Oklahoma (LASSO) and site-related biases and scattering in source parameter measurements due to simplified attenuation models. We measure the high-frequency spectral decay parameter kappa on the vertical acceleration spectra of regional earthquakes (125 km away). The site-dependent kappa (κ0,acc) suggests that attenuation increases rapidly at shallow depth and is highly site-dependent. 10%–75% of the attenuation is site-dependent for S waves and even larger for P waves. The quality factor for S waves (QS) ranges from 10 to 100 in the upper 400 m. QP for P waves is mostly below 10 within the same depth. The Quaternary sediments tend to be more attenuating (QS<30), but the Permian rocks also can have high attenuation. We demonstrate that using a non-site-dependent attenuation model in single-spectra fitting leads to large scattering in fc estimates among stations with apparent good fits. The apparent fc can significantly deviate when the range of site-dependent kappa is large or with a higher assumed source spectral fall-off rate n. The biases in apparent fc depend on site condition and distance; however, the correlation between fc and these factors might not be obvious, depending on model assumptions. An apparent increase of stress drop with magnitude in a previous study for local microearthquakes (1.3

Chang, Hilary↗

A statistical rain attenuation prediction model with application to the advanced communication technology satellite project. Part 2: Theoretical development of a dynamic model and application to rain fade durations and tolerable control delays for fade countermeasures

A dynamic rain attenuation prediction model is developed for use in obtaining the temporal characteristics, on time scales of minutes or hours, of satellite communication link availability. Analagous to the associated static rain attenuation model, which yields yearly attenuation predictions, this dynamic model is applicable at any location in the world that is characterized by the static rain attenuation statistics peculiar to the geometry of the satellite link and the rain statistics of the location. Such statistics are calculated by employing the formalism of Part I of this report. In fact, the dynamic model presented here is an extension of the static model and reduces to the static model in the appropriate limit. By assuming that rain attenuation is dynamically described by a first-order stochastic differential equation in time and that this random attenuation process is a Markov process, an expression for the associated transition probability is obtained by solving the related forward Kolmogorov equation. This transition probability is then used to obtain such temporal rain attenuation statistics as attenuation durations and allowable attenuation margins versus control system delay.

Manning, Robert M.↗

Ultrasonic Attenuation Results of Thermoplastic Resin Composites Undergoing Thermal and Fatigue Loading

As part of an effort to obtain the required information about new composites for aviation use, materials and NDE researchers at NASA are jointly performing mechanical and NDE measurements on new composite materials. The materials testing laboratory at NASA is equipped with environmental chambers mounted on load frames that can expose composite materials to thermal and loading cycles representative of flight protocols. Applying both temperature and load simultaneously will help to highlight temperature and load interactions during the aging of these composite materials. This report highlights our initial ultrasonic attenuation results from thermoplastic composite samples that have undergone over 4000 flight cycles to date. Ultrasonic attenuation measurements are a standard method used to assess the effects of material degradation. Recently, researchers have shown that they could obtain adequate contrast in the evaluation of thermal degradation in thermoplastic composites by using frequencies of ultrasound on the order of 24 MHz. In this study, we address the relationship of attenuation measured at lower frequencies in thermoplastic composites undergoing both thermal and mechanical loading. We also compare these thermoplastic results with some data from thermoset composites undergoing similar protocols. The composite s attenuation is reported as the slope of attenuation with respect to frequency, defined as b = Da(f)/Df. The slope of attenuation is an attractive parameter since it is quantitative, yet does not require interface corrections like conventional quantitative attenuation measurements. This latter feature is a consequence of the assumption that interface correction terms are frequency independent. Uncertainty in those correction terms can compromise the value of conventional quantitative attenuation data. Furthermore, the slope of the attenuation more directly utilizes the bandwidth information and in addition, the bandwidth can be adjusted in the post processing stage to compensate for the loss of dynamic range of the signal as the composites age.

Madaras, Eric I.↗

Attenuated Vector Tomography -- An Approach to Image Flow Vector Fields with Doppler Ultrasonic Imaging

The measurement of flow obtained using continuous wave Doppler ultrasound is formulated as a directional projection of a flow vector field. When a continuous ultrasound wave bounces against a flowing particle, a signal is backscattered. This signal obtains a Doppler frequency shift proportional to the speed of the particle along the ultrasound beam. This occurs for each particle along the beam, giving rise to a Doppler velocity spectrum. The first moment of the spectrum provides the directional projection of the flow along theultrasound beam. Signals reflected from points further away from the detector will have lower amplitude than signals reflected from points closer to the detector. The effect is very much akin to that modeled by the attenuated Radon transform in emission computed tomography.A least-squares method was adopted to reconstruct a 2D vector field from directional projection measurements. Attenuated projections of only the longitudinal projections of the vector field were simulated. The components of the vector field were reconstructed using the gradient algorithm to minimize a least-squares criterion. This result was compared with the reconstruction of longitudinal projections of the vector field without attenuation. Ifattenuation is known, the algorithm was able to accurately reconstruct both components of the full vector field from only one set of directional projection measurements. A better reconstruction was obtained with attenuation than without attenuation implying that attenuation provides important information for the reconstruction of flow vector fields.This confirms previous work where we showed that knowledge of the attenuation distribution helps in the reconstruction of MRI diffusion tensor fields from fewer than the required measurements. In the application of ultrasound the attenuation distribution is obtained with pulse wave transmission computed tomography and flow information is obtained with continuous wave Doppler.

60 APPLIED LIFE SCIENCES↗

Enhancement of the safety of live influenza vaccine by attenuating mutations from cold-adapted hemagglutinin

In our previous study, X-31ca-based H5N1 LAIVs, in particular, became more virulent in mice than the X-31ca MDV, possibly by the introduction of the surface antigens of highly pathogenic H5N1 influenza virus, implying that additional attenuation is needed in this cases to increase the safety level of the vaccine. In this report we suggest an approach to further increase the safety of LAIV through additional cold-adapted mutations in the hemagglutinin. The cold-adaptation of X-31 virus resulted in four amino acid mutations in the HA. We generated a panel of 7:1 reassortant viruses each carrying the hemagglutinins with individual single amino acid mutations. We examined their phenotypes and found a major attenuating mutation, N81K. This attenuation marker conferred additional temperature-sensitive and attenuation phenotype to the LAIV. Our data indicate that the cold-adapted mutation in the HA confers additional attenuation to the LAIV strain, without compromising its productivity and immune response. - Highlights: • Cold-adaptation process induced four amino acid mutations in the HA of X-31 virus. • The four mutations in the HA also contributed to attenuation of the X-31ca virus • N81K mutation was the most significant marker for the attenuation of X-31ca virus. • Introduction of N81K mutation into H3N2 LAIV further attenuated the vaccine. • This approach provides a useful guideline for enhancing the safety of the LAIVs.

60 APPLIED LIFE SCIENCES↗

Subsurface Structure of Long Valley Caldera Imaged With Seismic Scattering and Intrinsic Attenuation

Here we image seismic intrinsic (Q i -1 ) and scattering (Q s -1 ) attenuations in Long Valley Caldera, California, by analyzing more than 1,700 vertical component waveforms from local earthquakes. Observed energy envelopes are fit to the diffusion model and seismic attenuation images are produced using two-dimensional space weighting functions. Low intrinsic and low scattering attenuation anomalies in the center south of the caldera correspond to the location of an earthquake swarm in 2014. We identify high intrinsic and high scattering attenuation anomalies in the fluid-rich western and eastern areas of the caldera. From a comparison with other geophysical images (magnetotellurics and seismic tomography) we attribute these anomalies to a hydrothermal system (high attenuation). Average to high attenuation values are also observed at the adjacent Mammoth Mountain (southwest of the caldera) and may also have a hydrothermal origin. High intrinsic attenuation at low frequencies to the west of the Hartley Springs Fault may be produced by the magmatic system that produced the Inyo Craters. Finally, seismic attenuation imaging provides insights into subsurface structures that are complementary to velocity and conductivity images.

58 GEOSCIENCES↗