Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuation correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Afterpulse correction for micro-pulse lidar to improve middle and upper tropospheric aerosol measurements

Micro-pulse lidar (MPL) measurements have been widely used in atmospheric research over the past few decades. However, the MPL afterpulse noise has a large impact on the MPL aerosol measurement in the middle and upper troposphere, and an effective correction method is still lacking. Here, a new afterpulse correction approach is presented by using measurements with low-level optically thick clouds to act as the lids blocking atmospheric signals beyond the clouds completely. Examples are provided to illustrate the effectiveness of this correction method. Using one-year 2014 MPL measurements at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site, the impact of the correction on the aerosol measurements is quantified. The relative error (RE, %) of attenuated backscattering ratio (ABR) without the afterpulse correction is 30% and 190% at the height of 1.00 km and 9.00 km (AGL), and the RE is larger for weaker aerosol signals (ABR<2). The RE of linear depolarization ratio (LDR), which is significantly higher than that of ABR for a given aerosol layer, is highly non-linear above 3.00 km, with a value of 300%-900% for weak aerosols (ABR<2) above 3.00 km. Therefore, the afterpulse correction is critical for the middle and upper tropospheric aerosol observations. We demonstrated that our afterpulse correction can provide reasonable particle depolarization ratio (PDR) to properly identify dust aerosols. The newly developed method can be applied to long-term MPL measurements to support aerosol and mixed-phase/ice cloud interaction study at the NSA site.

54 ENVIRONMENTAL SCIENCES↗

Corrected Moments in Antenna Coordinates (CMAC) Technical Report

Various corrections are needed in order to extract the best value of the measurements from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility’s scanning precipitation radars. The Corrected Moments in Antenna Coordinates (CMAC) Value-Added Product provides an application chain for providing radar moments that are corrected for artifacts such as aliasing, attenuation, multi-trip echoes, and beam blockage. This technical report provides details on the entire process of correcting the ARM scanning precipitation radar data using CMAC. CMAC has been used at multiple ARM sites and ARM Mobile Facility deployments including the Tracking Aerosol Convection Interactions Experiment (TRACER), Cloud, Aerosol, and Complex Terrain Interactions (CACTI), and the Surface Atmosphere Integrated Laboratory (SAIL).

54 ENVIRONMENTAL SCIENCES↗

AMICE2 measurements of lab-generated and ambient aerosols at BNL from 2025-07-21 to 2025-08-22

From July 21 through August 22, 2025 the Absorption Measurement Inter-Comparison Experiment phase 2 (AMICE2) was conducted at Brookhaven National Laboratory. The experiment included concurrent operation of several filter-based instruments and in situ instruments sampling from a common sample line. The common sample line provided all instruments with either lab-generated aerosols composed of external mixtures of nigrosin, cabojet, and ammonium sulfate, or with ambient aerosol drawn through an external stack. This data set contains measurements from the CAPS PMssa instrument taken as a reference instrument at 532 nm and against which the effectiveness of the filter corrections may be assessed. It also contains attenuation coefficients from all filter-based instruments and filter transmittances in order to permit correction for filter loading, and the SSA and COA to permit corrections for aerosol darkness. Finally, two sets of multiplicative corrections are provided for the AE-33, TAP, and MA-350 instruments: the first one, Corr1, corrects for filter amplification factor and loading, the second one, Corr2, corrects for the aerosol darkness in terms of the natural log of COA.

Aerosol Extinction↗

Correcting thermal-emission-induced detector saturation in infrared spectroscopy

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens. These errors can arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent errors can be corrected by implementing several levels of optical attenuation that enable convergence testing of the measured reflectance or transmittance as the thermal-emission signal is reduced, or by applying correction factors that can be inferred by looking at the spectral regions where the sample is not expected to have a substantial temperature dependence.

47 OTHER INSTRUMENTATION↗

Less than the sum of its parts: the dust-corrected H α luminosity of star-forming galaxies explored at different spatial resolutions with MaNGA and MUSE

ABSTRACT The H α and H β emission-line luminosities measured in a single integrated spectrum are affected in non-trivial ways by point-to-point variations in dust attenuation in a galaxy. This work investigates the impact of this variation when estimating global H α luminosities corrected for the presence of dust by a global Balmer decrement. Analytical arguments show that the dust-corrected H α luminosity is always underestimated when using the global H α/H β flux ratio to correct for dust attenuation. We measure this effect on 156 face-on star-forming galaxies from the Mapping Nearby Galaxies at APO (MaNGA) survey. At 1–2 kpc spatial resolution, the effect is small but systematic, with the integrated dust-corrected H α luminosity underestimated by 2–4 per cent (and typically not more than by 10 per cent), and depends on the specific star formation rate of the galaxy. Given the spatial resolution of MaNGA, these are lower limits for the effect. From Multi Unit Spectroscopic Explorer (MUSE) observations of NGC 628 with a resolution of 36 pc, we find the discrepancy between the globally and the point-by-point dust-corrected H α luminosity to be 14 ± 1 per cent, which may still underestimate the true effect. We use toy models and simulations to show that the true difference depends strongly on the spatial variance of the H α/H β flux ratio, and on the slope of the relation between H αluminosity and dust attenuation within a galaxy. Larger samples of higher spatial resolution observations are required to quantify the dependence of this effect as a function of galaxy properties.

Vale Asari, N.↗

Probabilistic Programming for Transportable Source Characterization and Uncertainty Quantification of the North Korean Nuclear Tests 2006–2017

Here, we introduce a transportable technique to determine the yield and depth of burial (DOB) from seismic source spectra of underground nuclear explosions. We demonstrate this technique on the six declared North Korean nuclear tests. This approach derives source spectra in absolute units from regional phase (Pg) amplitudes by correcting the observations for geometric spreading, attenuation, and site amplification. We couple the source spectra and explosion source models with a probabilistic programming framework that integrates deep learning techniques and Bayesian modeling. This approach permits the exchange of information across various data categories to quantify both the data and model uncertainty. This technique stands out as an innovative use of broad‐area propagation models, making it transportable across various geologic settings. This method proves to be effective in scenarios with diverse and/or limited observational data, even when the source depth is unknown. We present new independent estimates of absolute yield and DOB that are consistent with the prior assessments, underscoring the potential of this method in enhancing transportable nuclear explosion monitoring capabilities.

58 GEOSCIENCES↗

Charge response and energy calibration of ProtoDUNE-SP

ProtoDUNE-SP at the CERN Neutrino Platform is a test bed liquid argon time pro-jection chamber (LArTPC) for the far-detector in the Deep Underground Neutrino Ex-periment (DUNE). Space charge eects, attenuation due to electronegative impurities,diusion, and electronics gain variations cause nonuniformities in charge depositionper unit length (dQ/dx) within a LArTPC. Corrections for space charge eects withmeasured electric-eld maps and attenuation with purity-monitor data were applied.A sample of cosmic-ray muons crossing the cathode is used to calibrate the detectorresponse to get a uniform dQ/dx over space and time. Using cosmic-ray stoppingmuons, which have a well-known energy loss per unit length (dE/dx), the absoluteenergy scale was determined. These calibration factors were uploaded to a databasefor use in further physics analysis.

43 PARTICLE ACCELERATORS↗

Deep learning‑based metal artefact reduction in X-ray computed tomography of TRISO fuel compacts

TRISO (TRi-structural ISOtropic) – compact-type micro-particle fuels – are next generation nuclear fuel compacts designed with safety in mind. Structural integrity and characterisation before and after irradiation are important to determine the performance of the fuel compacts under real reactor conditions. X-ray computed tomography can be an important tool for non-destructive evaluation of these fuel compacts. The fuel particles are highly attenuating for X-rays which creates metal artefact, rendering the images unusable. Our artefact correction can mitigate these artefacts significantly. The proposed method works by first segmenting highly-attenuating structures (metal) and forward projecting to localise the source of artefacts in the projection domain, then, using a traditional or U-net-based deep learning architecture, contextually interpolating those regions to remove the artefacts. Finally the reconstruction from the modified projection is fused with the segmented metal. The proposed method shows a significant improvement in the image quality while significantly reducing the reconstruction time compared to the standard technique.

Rahman, Obaid [ORNL] (ORCID:0000000277810840)↗

Using Simulation to Interpret LArS's Results

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Noble Liquid Testing Facility (NLTF) at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced silicon photo multiplier (SiPM). With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.]↗

Identification of the Liquid Argon Scattering Experimental Discrepancies Using Simulation

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Proton Assembly Building at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS’s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced photo multiplier. With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.; Fermilab]↗

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗

Quantitative Correction of Ohmic Effects on Square Wave Voltammetry for High-Concentration Soluble-Soluble Redox Reactions in Molten Salts

Molten salts are of particular interest for a variety of industrial applications. As such, accurate characterization of species’ concentrations within the molten salt media is critical to ensure a well-controlled unit operation. Although electroanalytical tools are properly suited for precise in situ monitoring in these systems, uncompensated ohmic resistance R Ω can lead to erroneous, technique-dependent results. Using numerical simulations applied to a model system, this work will first illustrate then quantify the extent to which R Ω attenuates square wave voltammograms. This approach allows for post-experiment correction that leads to converging results across voltammetric techniques and facilitates accurate predictions of species’ concentrations.

Shaheen, Nora A. [Argonne National Laboratory (ANL↗

Scatter Removal using Black Body Grids and Determining the Minimum Resolvable Hydrogen Concentration at MARS

This dataset was used to develop and validate a scatter-correction pipeline for neutron radiographs acquired at the MARS beamline, based on the methodology of Carminati et al. (2019). Scatter removal was performed using 36 gadolinium black bodies to characterize and remove the spatially varying neutron scatter field that cannot be eliminated by conventional open-beam normalization. The dataset comprises eight samples - four single-crystal nickel and four polycrystalline austenitic 316L stainless steel. Within each material system, samples were pre-charged with hydrogen gas at four charging pressures (1.5, 5, 12.5, and 20 kpsi). Following scatter correction, the pipeline was applied to all radiographs to recover quantitative attenuation maps. After subtracting the known attenuation contribution of the metal matrix, spatial maps of the hydrogen attenuation coefficient were obtained for each sample. This data was then used to construct a calibration curve relating hydrogen attenuation to hydrogen concentration and to determine the minimum resolvable hydrogen concentration at the MARS beamline. The resulting dataset provides a pressure-resolved calibration standard for quantitative hydrogen mapping using neutron radiography.

36 MATERIALS SCIENCE↗

Ka-Band ARM Zenith Radar Corrections (KAZRCOR, KAZRCFRCOR) Value-Added Products

The KAZRCOR Value -added Product (VAP) performs several corrections to the ingested KAZR moments and also creates a significant detection mask for each radar mode. The VAP computes gaseous attenuation as a function of time and radial distance from the radar antenna, based on ambient meteorological observations, and corrects observed reflectivities for that effect. KAZRCOR also dealiases mean Doppler velocities to correct velocities whose magnitudes exceed the radar’s Nyquist velocity. Input KAZR data fields are passed through into the KAZRCOR output files, in their native time and range coordinates. Complementary corrected reflectivity and velocity fields are provided, along with a mask of significant detections and a number of data quality flags. This report covers the KAZRCOR VAP as applied to the original KAZR radars and the upgraded KAZR2 radars. Currently there are two separate code bases for the different radar versions, but once KAZR and KAZR2 data formats are harmonized, only a single code base will be required.

54 ENVIRONMENTAL SCIENCES↗

Ka-Band ARM Zenith Radar Corrections (KAZRCOR, KAZRCFRCOR) Value-Added Products

The Ka-Band Atmospheric Radiation Measurement (ARM) Zenith Radar Corrections (KAZRCOR) and KA-Band ARM Zenith Radar CF-Radial, Corrected (KAZRCFRCOR) value-added products (VAPs) perform several corrections to the ingested KAZR moments and also create a significant detection mask for each radar mode. The VAPs compute gaseous attenuation as a function of time and radial distance from the radar antenna, based on ambient meteorological observations, and correct observed reflectivities for that effect. Mean Doppler velocities are dealiased to correct velocities whose magnitudes exceed the radar’s Nyquist velocity. Input KAZR data fields are passed through to the KAZRCOR or KAZRCFRCOR output files, in their native time and range coordinates. Complementary corrected reflectivity and velocity fields are provided, along with a mask of significant detections and a number of data quality flags. This report covers the KAZRCOR VAP as applied to the original KAZR radars and the upgraded KAZR2 radars. Originally, prior to late 2019, there were two separate code bases for the different radar versions. Following the harmonization of KAZR and KAZR2 data formats in 2019, only a single code base is required. The new combined KAZR and KAZR2 code base is called the KAZRCFRCOR VAP. The ‘cfr portion of the VAP name refers to the Radial Climate and Forecasting data format standards that are used in these data sets. Throughout this report, references to ‘KAZRCOR’ should be taken to apply to the ‘KAZRCFRCOR’ VAP as well unless there is an explicit statement to the contrary.

54 ENVIRONMENTAL SCIENCES↗

Data Product: Ka ARM Zenith Radar (KAZR), in CfRadial format: precipitation mode, corrected

The KAZRCFRCOR Value Added Product (VAP) performs several corrections to the ingested KAZR data and also creates a significant detection mask for each radar mode. The VAP computes gaseous attenuation as a function of time and radial distance from the radar antenna, based on ambient relative humidity, and corrects observed reflectivities for that effect. KAZR reflectivities are also corrected in the antenna ‘nearfield’ range to compensate for the near-field antenna pattern and gain. KAZRCFRCOR also dealiases mean Doppler velocities, to correct velocities whose magnitudes exceed the radar’s Nyquist velocity. This dataset contains the 'kazrpr' (precipitation) mode output from this VAP.

54 ENVIRONMENTAL SCIENCES↗