Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arterial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An Explainable Machine-Learning Model for Compensatory Reserve Measurement: Methods for Feature Selection and the Effects of Subject Variability

Tracking vital signs accurately is critical for triaging a patient and ensuring timely therapeutic intervention. The patient’s status is often clouded by compensatory mechanisms that can mask injury severity. The compensatory reserve measurement (CRM) is a triaging tool derived from an arterial waveform that has been shown to allow for earlier detection of hemorrhagic shock. However, the deep-learning artificial neural networks developed for its estimation do not explain how specific arterial waveform elements lead to predicting CRM due to the large number of parameters needed to tune these models. Alternatively, we investigate how classical machine-learning models driven by specific features extracted from the arterial waveform can be used to estimate CRM. More than 50 features were extracted from human arterial blood pressure data sets collected during simulated hypovolemic shock resulting from exposure to progressive levels of lower body negative pressure. A bagged decision tree design using the ten most significant features was selected as optimal for CRM estimation. This resulted in an average root mean squared error in all test data of 0.171, similar to the error for a deep-learning CRM algorithm at 0.159. By separating the dataset into sub-groups based on the severity of simulated hypovolemic shock withstood, large subject variability was observed, and the key features identified for these sub-groups differed. This methodology could allow for the identification of unique features and machine-learning models to differentiate individuals with good compensatory mechanisms against hypovolemia from those that might be poor compensators, leading to improved triage of trauma patients and ultimately enhancing military and emergency medicine.

60 APPLIED LIFE SCIENCES↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

HMGA2 contributes to vascular development and sprouting angiogenesis by promoting IGFBP2 production

Highlights: • Our findings demonstrates that HMGA2 promotes central arteries formation in zebrafish. • HMGA2 induces vascular development through modulation of IGFBP2 whatever in vivo or in vitro. • The mRNA expressions of HMGA2 and IGFBP2 increased significantly in peripheral blood of Hemangioma patients. • HMGA2-IGFBP2 are promising candidates towards therapeutical vascularization in vascular diseases like Hemangioma. Angiogenesis is the process by which new blood vessels form from preexisting vessels and regulates the processes of embryonic development, wound healing and tumorigenesis. HMGA2 is involved in the occurrence of several cancers, but its biological role and the exact downstream genes involved in vascular development and sprouting angiogenesis remain largely unknown. Here, we first found that HMGA2 knockdown in zebrafish embryos resulted in defects of central artery formation. RNA sequencing revealed that IGFBP2 was significantly downregulated by interference with HMGA2, and IGFBP2 overexpression reversed the inhibition of brain vascular development caused by HMGA2 deficiency. In vitro, we further found that HMGA2 knockdown blocked the migration, tube formation and branching of HUVECs. Similarly, IGFBP2 protein overexpression attenuated the impairments induced by HMGA2 deficiency. Moreover, the promotion of angiogenesis by HMGA2 overexpression was verified in a Matrigel plug assay. We next found that HMGA2 bound directly to a region in the IGFBP2 promoter and positively regulated IGFBP2 expression. Interestingly, the mRNA expression levels of HMGA2 and IGFBP2 were increased significantly in the peripheral blood of hemangioma patients, indicating that overexpression of HMGA2 and IGFBP2 results in vessel formation, consistent with the results of the in vivo and in vitro experiments. In summary, our findings demonstrate that HMGA2 promotes central artery formation by modulating angiogenesis via IGFBP2 induction.

60 APPLIED LIFE SCIENCES↗

Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

Coronary artery disease (CAD) is highly prevalent and associated with adverse events. Challenges have emerged in the treatment of intermediate coronary artery stenoses. These lesions are often interrogated with fractional flow reserve (FFR) testing to determine if a stenosis is likely to be causative for ischemia in a cardiac territory. This invasive test requires insertion of a pressure wire into a coronary vessel. Recently computational fluid dynamics (CFD) has been used to noninvasively assess fractional flow reserve in vessels reconstructed from medical imaging data. However, many of these simulations are unable to provide additional information about intravascular hemodynamics, including velocity, endothelial shear stress (ESS), and vorticity. We hypothesized that vorticity, which has demonstrated utility in the assessment of ventricular and aortic diseases, would also be an important hemodynamic factor in CAD. Three-dimensional (3D), patient-specific coronary artery geometries that included all vessels >1 mm in diameter were created from angiography data obtained from 10 patients who underwent diagnostic angiography and FFR testing (n = 9). A massively parallel CFD solver (HARVEY) was used to calculate coronary hemodynamic parameters including pressure, velocity, ESS, and vorticity. These simulations were validated by comparing velocity flow fields from simulation to both velocities derived from in vitro particle image velocimetry and to invasively acquired pressure wire-based data from clinical testing. There was strong agreement between findings from CFD simulations and particle image velocimetry experimental testing (p < 0.01). CFD-FFR was also highly correlated with invasively measured FFR (ρ = 0.77, p = 0.01) with an average error of 5.9 ± 0.1%. CFD-FFR also had a strong inverse correlation with the vorticity (ρ = -0.86, p = 0.001). Simulations to determine the effect of the coronary stenosis on intravascular hemodynamics demonstrated significant differences in velocity and vorticity (both p < 0.05). Further evaluation of an angiographically normal appearing non-FFR coronary vessel in patients with CAD also demonstrated differences in vorticity when compared with FFR vessels (p < 0.05). The use of highly accurate 3D CFD-derived intravascular hemodynamics provides additional information beyond pressure measurements that can be used to calculate FFR. Vorticity is one parameter that is modified by a coronary stenosis and appears to be abnormal in angiographically normal vessels in patients with CAD, highlighting a possible use-case in preventative screening for early coronary disease.

59 BASIC BIOLOGICAL SCIENCES↗

A 1D–0D–3D coupled model for simulating blood flow and transport processes in breast tissue

In this work, we present mixed dimensional models for simulating blood flow and transport processes in breast tissue and the vascular tree supplying it. These processes are considered, to start from the aortic inlet to the capillaries and tissue of the breast. Large variations in biophysical properties and flow conditions exist in this system necessitating the use of different flow models for different geometries and flow regimes. In total, we consider four different model types. First, a system of 1D nonlinear hyperbolic partial differential equations (PDEs) is considered to simulate blood flow in larger arteries with highly elastic vessel walls. Second, we assign 1D linearized hyperbolic PDEs to model the smaller arteries with stiffer vessel walls. The third model type consists of ODE systems (0D models). It is used to model the arterioles and peripheral circulation. Finally, homogenized 3D porous media models are considered to simulate flow and transport in capillaries and tissue within the breast volume. Sink terms are used to account for the influence of the venous and lymphatic systems. Combining the four model types, we obtain two different 1D–0D–3D coupled models for simulating blood flow and transport processes: The first model results in a fully coupled 1D–0D–3D model covering the complete path from the aorta to the breast combining a generic arterial network with a patient specific breast network and geometry. The second model is a reduced one based on the separation of the generic and patient specific parts. The information from a calibrated fully coupled model is used as inflow condition for the patient specific sub-model allowing a significant computational cost reduction. Several numerical experiments are conducted to calibrate the generic model parameters and to demonstrate realistic flow simulations compared to existing data on blood flow in the human breast and vascular system. Moreover, we use two different breast vasculature and tissue data sets to illustrate the robustness of our reduced sub-model approach.

multiscale blood flow models↗

Studying the effect of drug-to-excipient ratio on drug release profile for drug coated balloons

Drug-coated balloons (DCB) have emerged as the alternative procedure for restenosis because of their ability to treat a variety of occlusion types with a uniform dose of anti-proliferative drugs. DCB are balloons coated with antiproliferative drugs encapsulated in a polymer matrix. There are several types of coating matrices used to produce DCB. In this study, the relationship between coating composition and drug release under physiologically relevant conditions was examined to understand how differences in coating composition impacts the drug transfer from the balloon surface to the simulated body fluids. To conduct the experiments, the balloons were coated with different paclitaxel (drug)-to-iopromide (excipient) ratios (3:1, 3:2 and 1:2) using an in-house developed micro-pipetting method. Scanning electron microscopy (SEM) images showed that the 3:1 PTX:IOP ratio produced a more uniform, crystalline microstructure with a thinner coating throughout the balloon surface compared to the other drug-to-excipient ratios. The 1:2 PTX:IOP ratio showed the least crystalline microstructure among the three ratios evaluated in this study. Three different drug elution conditions were tested. The amount of drug released to the medium was quantified by high performance liquid chromatography (HPLC). Our soaking study and submerge & deploy study showed that ~20% of the drug transferred to the target site under physiological conditions. A track and deploy method was performed using a “mock” artery, to simulate an in vitro environment. Coated balloons were passed through the mock artery to mimic tracking turns the balloon within the arteries during the angioplasty procedures. Seven elution samples were collected at different stages of the procedure. Finally, drug release results suggest that the higher excipient ratio helps to deliver the lipophilic drug to the target site under simulated conditions but causes higher drug loss during the balloon transfer process.

60 APPLIED LIFE SCIENCES↗

Radiation effects on atherosclerosis in atomic bomb survivors: a cross-sectional study using structural equation modeling

Past reports indicated that total-body irradiation at low to moderate doses could be responsible for cardiovascular disease risks, but the mechanism remains unclear. The purpose of this study was to investigate the association between radiation exposure and atherosclerosis, an underlying pathology of cardiovascular diseases, in the Japanese atomic bomb survivors. We performed a cross-sectional study measuring 14 clinical-physiological atherosclerosis indicators during clinical exams from 2010 to 2014 in 3274 participants of the Adult Health Study cohort. Multivariable analyses were performed by using a structural equation model with latent factors representing underlying atherosclerotic pathologies: (1) arterial stiffness, (2) calcification, and (3) plaque as measured with indicators chosen a priori on the basis of clinical-physiological knowledge. Radiation was linearly associated with calcification (standardized coefficient per Gy 0.15, 95 % confidence interval: CI [0.070, 0.23]) and plaque (0.11, 95 % CI [0.029, 0.20]), small associations that were comparable to about 2 years of aging per Gy of radiation exposure, but not with arterial stiffness (0.036, 95 % CI [-0.025, 0.095]). The model fitted better and had narrower confidence intervals than separate ordinary regression models explaining individual indicators independently. The associations were less evident when the dose range was restricted to a maximum of 2 or 1 Gy. By combining individual clinical-physiological indicators that are correlated because of common, underlying atherosclerotic pathologies, we found a small, but significant association of radiation with atherosclerosis.

59 BASIC BIOLOGICAL SCIENCES↗

Plasma proteomics of SARS-CoV-2 infection and severity reveals impact on Alzheimer’s and coronary disease pathways

Identification of proteins dysregulated by COVID-19 infection is critically important for better understanding of its pathophysiology, building prognostic models, and identifying new targets. Plasma proteomic profiling of 4,301 proteins was performed in two independent datasets and tested for the association for three COVID-19 outcomes (infection, ventilation, and death). We identified 1,449 proteins consistently associated in both datasets with any of these three outcomes. We subsequently created highly accurate models that distinctively predict infection, ventilation, and death. These proteins were enriched in specific biological processes including cytokine signaling, Alzheimer’s disease, and coronary artery disease. Mendelian randomization and gene network analyses identified eight causal proteins and 141 highly connected hub proteins including 35 with known drug targets. Our findings provide distinctive prognostic biomarkers for two severe COVID-19 outcomes, reveal their relationship to Alzheimer’s disease and coronary artery disease, and identify potential therapeutic targets for COVID-19 outcomes.

60 APPLIED LIFE SCIENCES↗

Intramyocardial hemorrhage drives fatty degeneration of infarcted myocardium

Sudden blockage of arteries supplying the heart muscle contributes to millions of heart attacks (myocardial infarction, MI) around the world. Although re-opening these arteries (reperfusion) saves MI patients from immediate death, approximately 50% of these patients go on to develop chronic heart failure (CHF) and die within a 5-year period; however, why some patients accelerate towards CHF while others do not remains unclear. Here we show, using large animal models of reperfused MI, that intramyocardial hemorrhage - the most damaging form of reperfusion injury (evident in nearly 40% of reperfused ST-elevation MI patients) - drives delayed infarct healing and is centrally responsible for continuous fatty degeneration of the infarcted myocardium contributing to adverse remodeling of the heart. Specifically, we show that the fatty degeneration of the hemorrhagic MI zone stems from iron-induced macrophage activation, lipid peroxidation, foam cell formation, ceroid production, foam cell apoptosis and iron recycling. We also demonstrate that timely reduction of iron within the hemorrhagic MI zone reduces fatty infiltration and directs the heart towards favorable remodeling. Collectively, our findings elucidate why some, but not all, MIs are destined to CHF and help define a potential therapeutic strategy to mitigate post-MI CHF independent of MI size.

60 APPLIED LIFE SCIENCES↗

Area-Preserving Mapping of 3D Carotid Ultrasound Images Using Density-Equalizing Reference Map

Carotid atherosclerosis is a focal disease at the bifurcations of the carotid artery. To quantitatively monitor the local changes in the vessel-wall-plus-plaque thickness (VWT) and compare the VWT distributions for different patients or for the same patients at different ultrasound scanning sessions, a mapping technique is required to adjust for the geometric variability of different carotid artery models. In this work, we propose a novel method called density-equalizing reference map (DERM) for mapping 3D carotid surfaces to a standardized 2D carotid template, with an emphasis on preserving the local geometry of the carotid surface by minimizing the local area distortion. The initial map was generated by a previously described arc-length scaling (ALS) mapping method, which projects a 3D carotid surface onto a 2D non-convex L-shaped domain. A smooth and area-preserving flattened map was subsequently constructed by deforming the ALS map using the proposed algorithm that combines the density-equalizing map and the reference map techniques. This combination allows, for the first time, one-to-one mapping from a 3D surface to a standardized non-convex planar domain in an area-preserving manner. Evaluations using 20 carotid surface models show that the proposed method reduced the area distortion of the flattening maps by over 80% as compared to the ALS mapping method.

60 APPLIED LIFE SCIENCES↗

Collagen Fibril Orientation in Tissue Specimens From Atherosclerotic Plaque Explored Using Small Angle X-Ray Scattering

Atherosclerotic plaques can gradually develop in certain arteries. Disruption of fibrous tissue in plaques can result in plaque rupture and thromboembolism, leading to heart attacks and strokes. Collagen fibrils are important tissue building blocks and tissue strength depends on how fibrils are oriented. Fibril orientation in plaque tissue may potentially influence vulnerability to disruption. While X-ray scattering has previously been used to characterize fibril orientations in soft tissues and bones, it has never been used for characterization of human atherosclerotic plaque tissue. This study served to explore fibril orientation in specimens from human plaques using small angle X-ray scattering (SAXS). Additionally, plaque tissue was extracted from human femoral and carotid arteries, and each tissue specimen contained a region of calcified material. Three-dimensional (3D) collagen fibril orientation was determined along scan lines that started away from and then extended toward a given calcification. Fibrils were found to be oriented mainly in the circumferential direction of the plaque tissue at the majority of locations away from calcifications. However, in a number of cases, the dominant fibril direction differed near a calcification, changing from circumferential to longitudinal or thickness (radial) directions. Further study is needed to elucidate how these fibril orientations may influence plaque tissue stress–strain behavior and vulnerability to rupture.

60 APPLIED LIFE SCIENCES↗

Hestia SW-IFL Onroad Fossil Fuel Carbon Dioxide (FFCO2) product: Road segment-level annual FFCO2 emissions across Arizona (2017-2022), version 1.1

The SW-IFL onroad fossil fuel carbon dioxide (FFCO2) emissions data product represents CO2 emissions from the combustion of fossil fuels by motor vehicles (e.g., passenger cars, trucks, buses, motorcycles) traveling on designated roadways. The emissions are represented geographically on each road segment within the state of Arizona spanning the 2017 to 2022 time period. This data product was developed as part of the Southwest Urban Corridor Integrated Field Laboratory (SW-IFL) project, which aims to provide new knowledge and tools that address urban environmental issues by integrating high-resolution observations, modeling, and civic engagement. The emissions data are provided in CSV (input data, ONR_FFCO2_AZ_county.csv) and GeoPackage form (output polyline objects - about 786,000 road segments, XXXX_AZ_v1.1.gpkg) designated by road class (interstates, arterials, collectors, local). The metadata file (Metadata_SW-IFL_Onroad_annualFFCO2_v1.1.docx) provides details about attributes and data formats. The GeoPackage emissions data are provided separately for local roads and nonlocal roads (interstates, arterials, collectors). The method file (Methods_SW-IFL_Onroad_annualFFCO2_v1.1.docx) describes the data processing flow and data sources. Update on 2024-04-17: Updates were made to both the input emission data file (.csv) and output segment-level emission file (.gpkg). There was an update in county-level emission input data (ONR_FFCO2_AZ_county.csv) and the entire road segments were reprocessed to reflect this update.Update on 2024-04-29: Update was made to one output segment-level emission file (Nonlocal_AZ_v1.0.gpkg). There was an error in the AADT values and the data were reprocessed to reflect this update.Update on 2024-10-22: Temporal coverage was extended to include 2022. VMT values were recalculated using new AADT data and the entire road segments were reprocessed to reflect these updates.

54 ENVIRONMENTAL SCIENCES↗

Molecular Imaging of Matrix Metalloproteinase-2 in Atherosclerosis Using a Smart Multifunctional PET/MRI Nanoparticle

Matrix metalloproteinases from macrophages are important intraplaque components that play pivotal roles in plaque progression and regression. This study sought to develop a novel multifunctional positron emission tomography (PET) and magnetic resonance imaging (MRI) contrast agents based on MMP-2 cleavable nanoparticles to noninvasive assessment of MMP-2 activity in mouse carotid atherosclerotic plaques. Macrophage-rich vascular lesions were induced by carotid ligation plus high-fat diet and streptozotocin-induced diabetes in CL57/BL6 mice. To render iron oxide nanoparticles (IONP) specific for the extracellular MMP-2, the magnetic nanoparticle base material has been derivatized with 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA) for the nuclear tracer 64 Cu labeling and the MMP-2-cleavable peptide modified with polyethylene glycol 2000, yielding a multi-modality reporter ( 64 Cu-NOTA-IONP@MMP2c-PEG2K, MMP2cNPs) for PET/MR imaging. Small animal PET imaging and biodistribution data revealed that MMP2cNPs exhibited remarkable plaque uptake (3.06 ± 0.87% ID/g and 1.83 ± 0.28% ID/g at 4 and 12 h, respectively). And MMP2cNPs were rapidly cleared from the contralateral normal carotid artery, resulting in excellent plaque-to-normal carotid artery contrasts. Furthermore, in vivo MRI showed a preferential accumulation of MMP2cNPs in atherosclerotic lesions compared with the non-cleavable reference compound, MMP2ncNPs. In addition, histological analyses revealed iron accumulations in the carotid atherosclerotic plaque, in colocalization with MMP-2 expression and macrophages. Using a combination of innovative imaging modalities, in this study, we demonstrate the feasibility of applying the novel smart MMP2cNPs as a PET/MR hybrid imaging contrast agent for detection of MMP-2 in atherosclerotic plaque in vivo.

60 APPLIED LIFE SCIENCES↗

In vivo evaluation of an adaptive resuscitation controller using whole blood and crystalloid infusates for hemorrhagic shock

Introduction Hemorrhage remains the leading cause of preventable death on the battlefield. The most effective means to increase survivability is early hemorrhage control and fluid resuscitation. Unfortunately, fluid resuscitation requires constant adjustments to ensure casualty is properly managed, which is often not feasible in the pre-hospital setting. In this study, we showed how an adaptive closed-loop controller for hemorrhage resuscitation can be used to automate hemodynamic management using a swine hemorrhagic shock injury model. Methods The adaptive resuscitation controller (ARC) was previously developed to track pressure–volume responsiveness in real time and adjust its infusion rate to reach the target mean arterial pressure (MAP). Swine while maintained under a surgical plane of anesthesia and analgesia underwent a splenectomy, followed by two hemorrhage and resuscitation events. For the first resuscitation event, hemorrhage was induced to reduce the MAP to 35 mmHg until arterial lactate reached 4 mmol/L. The ARC system then infused whole blood (WB) to reach the target MAP and maintained the subject using crystalloids for 120 min. For the second resuscitation event, the subjects were hemorrhaged again but resuscitated using only crystalloid infusion to reach the target MAP and 120-min maintenance. Results The ARC was effective at WB resuscitation, reaching the target MAP in 2.0 ± 1.0 min. The median performance error was 1.1% ± 4.6%, and target overshoot was 14.4% ± 7.0% of the target MAP. The ARC maintained all animals throughout the 120 min maintenance period. For the second crystalloid-based resuscitation, ARC required a longer time to reach the target MAP, at an average rise time of 4.3 ± 4.0 min. However, target overshoot was reduced to 8.4% ± 7.3% of the target MAP. Much higher flow rates were required to maintain the target MAP during the second resuscitation event than during the first resuscitation event. Discussion The ARC was able to rapidly reach and maintain the target MAP effectively. However, this sometimes required large volumes of fluid as the ARC’s only goal was to reach the target MAP. Further clinical insight is needed regarding the preferred aggression level to achieve the target MAP. In conclusion, the ARC was successful in its programmed objective of reaching and maintaining the target MAP for extended periods of time in vivo , a critical next step toward improving hemorrhage treatment in the pre-hospital environment.

Snider, Eric J.↗

Performance Comparison of Object Detection Networks for Shrapnel Identification in Ultrasound Images

Ultrasound imaging is a critical tool for triaging and diagnosing subjects but only if images can be properly interpreted. Unfortunately, in remote or military medicine situations, the expertise to interpret images can be lacking. Machine-learning image interpretation models that are explainable to the end user and deployable in real time with ultrasound equipment have the potential to solve this problem. We have previously shown how a YOLOv3 (You Only Look Once) object detection algorithm can be used for tracking shrapnel, artery, vein, and nerve fiber bundle features in a tissue phantom. However, real-time implementation of an object detection model requires optimizing model inference time. Here, we compare the performance of five different object detection deep-learning models with varying architectures and trainable parameters to determine which model is most suitable for this shrapnel-tracking ultrasound image application. We used a dataset of more than 16,000 ultrasound images from gelatin tissue phantoms containing artery, vein, nerve fiber, and shrapnel features for training and evaluating each model. Every object detection model surpassed 0.85 mean average precision except for the detection transformer model. Overall, the YOLOv7tiny model had the higher mean average precision and quickest inference time, making it the obvious model choice for this ultrasound imaging application. Other object detection models were overfitting the data as was determined by lower testing performance compared with higher training performance. In summary, the YOLOv7tiny object detection model had the best mean average precision and inference time and was selected as optimal for this application. Next steps will implement this object detection algorithm for real-time applications, an important next step in translating AI models for emergency and military medicine.

60 APPLIED LIFE SCIENCES↗

Assessing endothelial function using a blood pressure cuff

Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve applying to the artery a substantially constant external pressure that causes the tension in the arterial wall to be reduced, where the pressure is provided via a cuff adjacent to and/or around a region of the mammal's body; determining, over the course of one or more cardiac cycles, changes in pressure in the cuff resulting from cardiac activity of the mammal to establish a baseline value for a parameter related to endothelial function in the mammal; applying a stimulus to the mammal; determining, over the course of one or more cardiac cycles, changes in pressure in the cuff resulting from cardiac activity of the mammal to establish a stimulus-effected value for a parameter related to endothelial function in the mammal; wherein the baseline value is determined from measurements made when the mammal is not substantially effected by the stimulus; and wherein differences in the baseline value and the stimulus-effected value provide a measure of endothelial function in the mammal.

Maltz, Jonathan S.↗

PTEN protects kidney against acute kidney injury by alleviating apoptosis and promoting autophagy via regulating HIF1-α and mTOR through PI3K/Akt pathway

Highlights: • PTEN protects kidney against acute kidney injury. • The effect of PTEN works by alleviating apoptosis and promoting autophagy via regulating HIF1-α and mTOR by PI3K/Akt pathway. Phosphatase and tensin homolog (PTEN) deleted on human chromosome 10 is a tumor suppressor with bispecific phosphatase activity, which is often involved in the study of energy metabolism and tumorigenesis. PTEN is recently reported to participate in the process of acute injury. However, the mechanism of PTEN in Ischemia-Reperfusion Injury (IRI) has not yet been clearly elucidated. In this study, mice with bilateral renal artery ischemia-reperfusion and HK-2 cells with hypoxia/reoxygenation (H/R) were used as acute kidney injury models. We demonstrated that PTEN was downregulated in IRI-induced kidney as well as in H/R-induced HK-2 cells. By silencing and overexpressing PTEN with si-PTEN RNA and PHBLV-CMV-PTEN-flag lentivirus before H/R, we found that PTEN protected HK-2 cells against H/R-induced injury reflected by the change in cell activity and the release of LDH. Furthermore, we inhibited HIF1-α with PX-478 and inactivated mTOR with Rapamycin before the silence of PTEN in H/R model. Our data indicated that the renoprotective effect of PTEN worked via PI3K/Akt/mTOR pathway and PI3K/Akt/HIF1-α pathway, hence alleviating apoptosis and improving autophagy respectively. Our findings provide valuable insights into the molecular mechanism underlying renoprotection of PTEN on autophagy and apoptosis induced by renal IRI, which offers a novel therapeutic target for the treatment of AKI.

60 APPLIED LIFE SCIENCES↗

Biomimetic tissue phantoms for neurosurgical near-infrared fluorescence imaging

Neurosurgical fluorescence imaging is a well-established clinical approach with a growing range of indications for use. However, this technology lacks effective phantom-based tools for development, performance testing, and clinician training. Our primary aim was to develop and evaluate 3D-printed phantoms capable of optically and morphologically simulating neurovasculature under fluorescence angiography. Volumetric digital maps of the circle of Willis with basilar and posterior communicator artery aneurysms, along with surrounding cerebral tissue, were generated. Phantoms were fabricated with a stereolithography printer using custom photopolymer composites, then visualized under white light and near-infrared fluorescence imaging. Feature sizes of printed components were found to be within 13% of digital models. Phantoms exhibited realistic optical properties and convincingly recapitulated fluorescence angiography scenes. Methods identified in this study can facilitate the development of realistic phantoms as powerful new tools for fluorescence imaging.

3D modeling↗