Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analyzed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Nanometer Aerosol Size Analyzer (nASA) for Rapid Measurement of High-Concentration Size Distributions

We have developed a fast-response Nanometer Aerosol Size Analyzer (nASA) that is capable of scanning 30 size channels between 3 and 100 nm in a total time of 3 seconds. The analyzer includes a bipolar charger (P0210), an extended-length Nanometer Differential Mobility Analyzer (Nano-DMA), and an electrometer (TSI 3068). This combination of components provides particle size spectra at a scan rate of 0.1 second per channel free of uncertainties caused by response-time-induced smearing. The nASA thus offers a fast response for aerosol size distribution measurements in high-concentration conditions and also eliminates the need for applying a de-smearing algorithm to resulting data. In addition, because of its thermodynamically stable means of particle detection, the nASA is useful for applications requiring measurements over a broad range of sample pressures and temperatures. Indeed, experimental transfer functions determined for the extended-length Nano-DMA using the Tandem Differential Mobility Analyzer (TDMA) technique indicate the nASA provides good size resolution at pressures as low as 200 Torr. Also, as was demonstrated in tests to characterize the soot emissions from the J85-GE engine of a T38 aircraft, the broad dynamic concentration range of the nASA makes it particularly suitable for studies of combustion or particle formation processes. Further details of the nASA performance as well as results from calibrations, laboratory tests and field applications are presented.

Han, Hee-Siew↗

The 2 Pi Charged Particles Analyzer: All-Sky Camera Concept and Development for Space Missions

Increasing the temporal resolution and instant coverage of velocity space of space plasma measurements is one of the key issues for experimentalists. Today, the top-hat plasma analyzer appears to be the favorite solution due to its relative simplicity and the possibility to extend its application by adding a mass-analysis section and an electrostatic angular scanner. Similarly, great success has been achieved in MMS mission using such multiple top-hat analyzers to achieve unprecedented temporal resolution. An instantaneous angular coverage of charged particles measurements is an alternative approach to pursuing the goal of high time resolution. This was done with 4-D Fast Omnidirectional Nonscanning Energy Mass Analyzer and, to a lesser extent, by DYMIO instruments for Mars-96 and with the Fast Imaging Plasma Spectrometer instrument for MErcury Surface, Space ENvironment, GEochemistry, and Ranging mission. In this paper we describe, along with precursors, a plasma analyzer with a 2 electrostatic mirror that was developed originally for the Phobos-Soil mission with a follow-up in the frame of the BepiColombo mission and is under development for future Russian missions. Different versions of instrument are discussed along with their advantages and drawbacks.

Vaisberg, O.↗

Plasma-Based Elemental Analyzer for Crewed Transit and Planetary Habitation

As NASA continues to perform research on the ISS and move towards the Moon and Mars, it is important for astronauts to have a technology capable of determining the composition of solid, liquid, and gas samples. Currently, samples are transported back to Earth for analysis, which may impact results due to the time delay of samples waiting to be returned to Earth as well as potential sample contamination from re-entry, change in environment, and various personnel handling. Therefore, researchers at the Applied Chemistry Lab at KSC have developed a proof-of-concept “Plasma-Based Elemental Analyzer,” which has the capability of testing solid, liquid, and gas samples for identification. Currently, the analysis is only qualitative, with quantitative identification left for future work. This technology is similar to ICP-OES, but differs in instrument size and sample preparation. Both technologies use plasma to ionize samples for light emission. The plasma elemental analyzer aims to be portable and lightweight, require only electrical power, and analyze solid, liquid, and gas samples. It does not use acid digestion or a nebulizer, requires less power than ICP-OES, and is able to operate with minimal to no usage of argon gas. Furthermore, the plasma elemental analyzer operates within low power constraints, which makes it feasible for usage on future missions with higher power constraints. The technology was tested at atmospheric pressure using mostly room air as the carrier gas for plasma production in the proof-of-concept study. The results showed the peak signals of the elements with an associated arbitrary signal intensity that allowed for qualitative identification. Solid samples that were tested included inedible biomass from the Golden Heirloom Cherry Tomato plant and Lunar Highlands Simulants (LHS-1). The liquid samples included elements of interest for the space crop production community. This work showed that a system smaller than the traditional ICP-OES equipment is able to be designed and implemented in future use cases, although it requires further development.

Kenneth Engeling↗

Evaluation of assumptions made by Hygroscopic Tandem Differential Mobility Analyzer inversion routines

The Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA) measures the hygroscopicity of atmospheric particles, and many atmospheric processes that change this hygroscopicity also change the atmospheric size distribution. Two assumptions made during H-TDMA inversion create spurious hygroscopic trends as a function of the changing inlet size distribution. These two assumptions—that the particles exiting the first Differential Mobility Analyzer (DMA1) are singly charged and that the inlet size distribution has a slope of zero (flat)— generate Multi-Charge Dispersion (MCD) bias and Slope bias, respectively. First, we use a model, named TAO, to show that the inlet size distribution could theoretically change the measured ammonium sulfate hygroscopicity by 10%–20% as a function of diameter or experimental time with no change in relative humidity. Secondly, we show experimentally that aerosol emitted from the flaming combustion of grass creates MCD bias. Here, in this experiment, we measure the CPC response of the first three charges and invert these responses using a new routine named Junior. Junior's inversion of each charge shows that one growth factor distribution describes all measured diameters (no growth dependence on diameter). As in the modeling study above, previous publications of this aerosol system, using traditional inversion assumptions, report a decrease in hygroscopicity as DMA1 diameter increases. Unlike traditional inversions, Junior's inversion does not assume the particles are singly charged nor does it make the flat inlet size distribution assumption. Instead, both the inlet size distribution and each charge's CPC response are measured quantities. Thus, the discrepancy between our inversion results and previous publications is likely due to the traditional inversion routine assumptions. This underscores the importance for accounting for Slope and MCD bias during inversions. Experimental results should be carefully analyzed when reporting hygroscopic trends with respect to diameter or experimental time when using the traditional inversion assumptions.

42 ENGINEERING↗

SynopFrame: Multiscale time-dependent visual abstraction framework for analyzing DNA nanotechnology simulations

We present an open-source framework, SynopFrame, that allows DNA nanotechnology (DNA-nano) experts to analyze and understand molecular dynamics simulation trajectories of their designs. We use a multiscale multi-dimensional abstraction space, connect the representations to a projected conformational space plot of the structure’s temporal sequence, and thus enable experts to analyze the dynamics of their structural designs and, specifically, failure cases of the assembly. In addition, our time-dependent abstraction representation allows the biologists, for the first time in a smooth and structurally clear way, to identify and observe temporal transitions of a DNA-nano design from one configuration to another, and to highlight important periods of the simulation for further analysis. We realize SynopFrame as a dashboard of the different synchronized 3D spatial and 2D schematic visual representations, with a color overlay to show essential properties such as the status of hydrogen bonds. The linking of the spatial, schematic, and abstract views ensures that users can effectively analyze the high-frequency motion. We also categorize the status of the hydrogen bonds into a new format to allow us to color-encode it and overlay it on the representations. To demonstrate the utility of SynopFrame, we describe example usage scenarios and report user feedback.

Abstraction space↗

$\mathrm{D}$ark$\mathrm{F}$lux: A new tool to analyze indirect-detection spectra of next-generation dark matter models

Here we present DarkFlux, a software tool designed to analyze indirect-detection signatures for next-generation models of dark matter (DM) with multiple annihilation channels. Version 1.0 of this tool accepts user-generated models with 2→2 tree-level dark matter annihilation to pairs of Standard Model (SM) particles and analyzes DM annihilation to γ rays. The tool consists of three modules, which can be run in a loop in order to scan over DM mass if desired: The annihilation fraction module calls an internal installation of MadDM, a dark matter phenomenology plugin for the Monte Carlo event generator MadGraph5 _ aMC@NLO, to compute the thermally averaged cross section $\langle σv\rangle_i$ for each annihilation channel $χχ$ ($\bar{χ}$,$χ^†$)→ i $\∈{SM, SM}. . The module then computes the fractional annihilation rate (annihilation fraction) into each channel. The flux module combines the flux spectrum from each annihilation channel, weighted by the appropriate annihilation fractions, to compute the total flux at Earth due to DM annihilation. In DarkFlux v1.0, this module specifically computes the γ-ray flux for each channel using the publicly available PPPC4DMID tables. The analysis module compares the total flux to observational data and computes the upper limit at 95% confidence level (CL) on the total thermally averaged DM annihilation cross section. In DarkFlux v1.0, this module compares the total γ-ray flux to a joint-likelihood analysis of fifteen dwarf spheroidal galaxies (dSphs) analyzed by the Fermi-LAT collaboration. DarkFlux v1.0 automatically provides data tables and can plot the output of these three modules. In this manual, we briefly motivate this indirect-detection computer tool and review the essential DM physics. We then describe the several modules of DarkFlux in greater detail. Finally, we show how to install and run DarkFlux and provide two worked examples demonstrating its capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Asymmetric Rowland circle geometries for spherically bent crystal analyzers in laboratory and synchrotron applications

Spherically bent crystal analyzers (SBCAs) are the dominant high-resolution hard X-ray optic in the ongoing rebirth of laboratory-based X-ray absorption fine structure (XAFS) and X-ray emission spectroscopy (XES) as well as in synchrotron methods such as high energy resolution fluorescence detection (HERFD) and non-resonant X-ray Raman scattering (XRS). In the overwhelming majority of cases, SBCAs are implemented in a ‘symmetric’ configuration on the Rowland circle, wherein the diffracting crystal plane is nominally coincident with the analyzer surface. We report here comprehensive investigations of ‘asymmetric’ operation of SBCA on the Rowland circle, wherein the diffracting crystal plane is not coincident with the optical surface of the analyzer. First, we have developed a laboratory spectrometer for XAFS and XES that is specialized for asymmetric SBCA operation. Here we find several benefits, including the capacity to use a single SBCA over a very wide energy range via ‘hkl hopping’ and the frequent ability to eliminate Johann error, the most prevalent energy-broadening mechanism when using SBCA symmetrically on the Rowland circle. Second, we expand these ideas to synchrotron facilities with a demonstration study of HERFD and XRS where asymmetric operation also provided advantage. Our results suggest that large-array systems for HERFD augmented with an additional mechanical degree of freedom could streamline user operation and also indicate benefits to XRS in the asymmetric configuration, where larger solid angle, larger sample-to-detector distance, and decreased Johann error can be achieved simultaneously.

47 OTHER INSTRUMENTATION↗

Quantum Computing in the Cloud: Analyzing job and machine characteristics

As the popularity of quantum computing continues to grow, quantum machine access over the cloud is critical to both academic and industry researchers across the globe. And as cloud quantum computing demands increase exponentially, the analysis of resource consumption and execution characteristics are key to efficient management of jobs and resources at both the vendor-end as well as the client-end. While the analysis of resource consumption and management are popular in the classical HPC domain, it is severely lacking for more nascent technology like quantum computing. This paper is a first-of-its-kind academic study, analyzing various trends in job execution and resources consumption / utilization on quantum cloud systems. We focus on IBM Furthermore, quantum systems and analyze characteristics over a two year period, encompassing over 6000 jobs which contain over 600,000 quantum circuit executions and correspond to almost 10 billion “shots” or trials over 20+ quantum machines. Specifically, we analyze trends focused on, but not limited to, execution times on quantum machines, queuing/waiting times in the cloud, circuit compilation times, machine utilization, as well as the impact of job and machine characteristics on all of these trends. Furthermore, our analysis identifies several similarities and differences with classical HPC cloud systems. Based on our insights, we make recommendations and contributions to improve the management of resources and jobs on future quantum cloud systems.

42 ENGINEERING↗

ASTM D03 Workshop: Developing a Hydrogen Contamination Detector Analyzer [Slides]

Non-hydrogen constituents in the fuel steam can cause irreversible damage to FC systems and therefore should be avoided. The objectives are: 1. Develop a low-cost fast response device (analyzer) to measure impurities in a dry hydrogen fuel stream at or above the SAE J2719 levels, 2. Develop understanding of a working mechanism and improve the analyzer by identifying the best materials and their configuration, and 3. Test the analyzer in real-world environments.

42 ENGINEERING↗

Multiplexing Focusing Analyzer for Efficient Stress-Strain Measurements

Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Harmonic distortion analyzer speeds setup of magnetic tape recorders

Harmonic distortion analyzer effects rapid and accurate setup and calibration of magnetic tape instrumentation recorders. The analyzer is portable, requires no warmup period and need not be calibrated for normal usage. Average setup time with this analyzer is approximately 30 seconds per track.

Tinari, D. F.↗

Pseudotachometer for mobile metabolic analyzer

Metabolic analyzer determines a patient's walking or ambulation speed and simultaneously measures his metabolic parameters. Analyzer is designed to move at some preselected human ambulation speed. During test, patient is connected to system and follows analyzer closely while his metabolic data is being monitored.

Currie, J. R.↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗

Prototype partial one-third octave band spectrum analyzer for acoustic, vibration and other wideband data for flight applications

The design refinement of a compact frequency analyzer for measurement and analysis on board flight vehicles is discussed. The analyzer has been constructed in a partial one-third octave band configuration with six filters and detectors spaced by the square root of 10 from 316 Hz to 100,000 Hz and a broadband detector channel. The analyzer has been tested over a temperature range of 40 to 120 F at a pressure of one atmosphere, and at a temperature of 75 F at an absolute pressure of 0.000001 torr, and has demonstrated at least 60 db of dynamic range.

Source record↗

The Pioneer 10 plasma analyzer results at Jupiter

Results are reported for the Pioneer 10 plasma-analyzer experiment at Jupiter. The analyzer system consisted of dual 90-deg quadrispherical electrostatic analyzers, multiple charged-particle detectors, and attendant electronics; it was capable of determining the incident plasma-distribution parameters over the energy range from 100 to 18,000 eV for protons and from approximately 1 to 500 eV for electrons. Data are presented on the interaction between the solar wind and the Jovian magnetosphere, the interplanetary ion flux, observations of the magnetosheath plasma, and traversals of the bow shock and magnetopause. Values are estimated for the proton isotropic temperature, number density, and bulk velocity within the magnetosheath flow field as well as for the beta parameter, ion number density, and magnetic-energy density of the magnetospheric plasma. It is argued that Jupiter has a reasonably thick magnetosphere somewhat similar to earth's except for the vastly different scale sizes involved.

Wolfe, J. H.↗

Analysis of a discrete spectrum analyzer for the detection of radio frequency interference

As the radio frequency spectrum becomes increasingly overcrowded, interference with mission-critical DSN operations is rising at an alarming rate. To alleviate this problem the DSN is developing a wideband surveillance system for on-site detection and identification of potential sources of radio frequency interference (RFI), which will complement the existing frequency coordination activities. The RFI monitoring system is based on a wideband, multi-look discrete spectrum analyzer operating on fast Fourier transform principles. An extensive general statistical analysis is presented of such spectrum analyzers and derives threshold detection performance formulas for signals of interest. These results are then applied to the design of the RFI spectrum analyzer under development.

Levitt, B. K.↗

Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

Shannon, A. V.↗

Experimental solar radio spectrum analyzer (50-100 MHz)

Summarized is the work carried out under a NASA Grant covering the period 15 October 1977 to 14 January 1978. The grant provided funds for the acquisition of an experimental radio spectrum analyzer covering the band 50-100 MHz, for use in a program of solar radio observations. Components for the experimental analyzer were duly obtained, and the system was assembled, checked, and put into operation in early February 1978. The analyzer is working in an entirely satisfactory manner and, from the time that it has been put into operation, it has played an important part in the on-going research programs in solar radio astronomy being conducted.

Maxwell, A.↗