Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical detection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Adaptive Envelope Detector-Based Phase Fault Detection Method for Power System Grid Distortions

In this study, a phase fault detection algorithm is developed by employing the envelope detector method. The proposed method diagnoses faults among phases and defines fault areas in the incoming signal. The designed algorithm consists of three steps: analytical signal conversion, complex magnitude, and fault detection. Initially, an analytical signal is obtained from the incoming power signal to determine the instantaneous amplitude and phase of the signal. A complex magnitude operation is applied to analytical signals to display changes in amplitude. On the basis of the threshold values specified by the user, the last step identifies the distortion signal in terms of the type of error and size. The proposed method is tested with realistically simulated substation power signal data and real power system data from the Grid Event Signature Library. The obtained results revealed that the proposed method detects distortions accurately.

Alaca, Ozgur↗

Exploring Approaches for Accelerated Mass Spectrometric Detection of Fluorochemicals from Aqueous Solutions Using Indirect, Adsorbent-Facilitated Desorption Ionization

There is a growing need for rapid, low-cost analytical tools to screen water supplies for persistent contaminants. Due to their ubiquitous presence in the environment and their detrimental effects on human health, there is a public interest in widespread testing for perfluoroalkyl substances (PFAS). However, the most common methods for PFAS analysis can be time-intensive, requiring a preconcentration step followed by liquid chromatography–mass spectrometry (LC–MS), and are cost-prohibitive for most members of the public. To address these challenges, this study explores a novel method for rapid analysis of aqueous analytes by concentrating analytes on solid adsorbents and detecting them using mass spectrometric analysis via desorption ionization directly from the adsorbent surface. We demonstrate this general approach of indirect solution analysis (ISA) with desorption electrospray ionization (ISA-DESI) and laser desorption ionization (ISA-LDI). Various adsorbent materials were screened, including commercial mesoporous carbons, alumina, and metal–organic frameworks (MOFs). Using ISA-DESI, we consistently detect concentrations as low as 5–100 parts per trillion (ppt) for perfluorooctanoic acid (PFOA) and 10–100 ppt for perfluoroundecanoic acid (PFUnDA). This approach enables rapid detection in under 5 min, making it suitable for applications requiring trace detection with fast response times. We further demonstrate the use of ISA-DESI on a range of environmentally relevant contaminants. Advantages of this indirect solution analysis approach include simplified sample preparation, accelerated analysis, and low cost with readily available materials, making it a promising tool to accelerate mass spectrometric PFAS detection for identifying contaminated sites, performing laboratory studies, and monitoring industrial waste streams.

Bays, Nathan Robert [Sandia National Laboratories ↗

Detection of anaerobic and aerobic bacteria from commercial tattoo and permanent makeup inks

ABSTRACT Tattooing and use of permanent makeup (PMU) have dramatically increased over the last decade, with a concomitant increase in ink-related infections. Studies have shown evidence that commercial tattoo and PMU inks are frequently contaminated with pathogenic microorganisms. Considering that tattoo inks are placed into the dermal layer of the skin where anaerobic bacteria can thrive and cause infections in low-oxygen environments, the prevalence of anaerobic and aerobic bacteria should be assessed in tattoo and PMU inks. In this study, we tested 75 tattoo and PMU inks using the analytical methods described in the FDA Bacteriological Analytical Manual Chapter 23 for the detection of both aerobic and anaerobic bacterial contamination, followed by 16S rRNA gene sequencing for microbial identification. Of 75 ink samples, we found 26 contaminated samples with 34 bacterial isolates taxonomically classified into 14 genera and 22 species. Among the 34 bacterial isolates, 19 were identified as possibly pathogenic bacterial strains. Two species, namelyCutibacterium acnes(four strains) andStaphylococcus epidermidis(two strains) were isolated under anaerobic conditions. Two possibly pathogenic bacterial strains,Staphylococcus saprophyticusandC. acnes, were isolated together from the same ink samples (n= 2), indicating that tattoo and PMU inks can contain both aerobic (S. saprophyticus) and anaerobic bacteria (C. acnes). No significant association was found between sterility claims on the ink label and the absence of bacterial contamination. The results indicate that tattoo and PMU inks can also contain anaerobic bacteria. IMPORTANCE The rising popularity of tattooing and permanent makeup (PMU) has led to increased reports of ink-related infections. This study is the first to investigate the presence of both aerobic and anaerobic bacteria in commercial tattoo and PMU inks under aerobic and anaerobic conditions. Our findings reveal that unopened and sealed tattoo inks can harbor anaerobic bacteria, known to thrive in low-oxygen environments, such as the dermal layer of the skin, alongside aerobic bacteria. This suggests that contaminated tattoo inks could be a source of infection from both types of bacteria. The results emphasize the importance of monitoring these products for both aerobic and anaerobic bacteria, including possibly pathogenic microorganisms.

Biotechnology & Applied Microbiology↗

Recalls of tattoo and permanent makeup inks in the United States and a follow-up microbiological survey of inks with a previous recall history

In this study, we collected voluntary recall records of tattoo and permanent makeup ink from the U.S. Food and Drug Administration (US FDA) Enforcement Report Database. The recall records contain information, such as recall date, manufacturer, ink color, reason for recall, and the microorganisms detected from the ink samples. Between 2003 and 2021, a total of 15 voluntary tattoo ink recalls occurred in the U.S. market, involving over 200 tattoo inks marketed by 13 manufacturers and one distributor. Fourteen recalls were due to microbial contamination, and one recall was due to allergic reaction. As follow-up, a microbiological survey of 28 tattoo inks of new batches from seven manufacturers having products that were previously recalled was conducted. Aerobic plate count (APC) and enrichment culture methods based on the FDA’s Bacteriological Analytical Manual (BAM) were used to detect microbial contamination. The results revealed that six out of 28 tattoo inks were contaminated with bacteria and were produced by two manufacturers. The level of microbial contamination was less than 250 CFU/g in three of the tattoo inks and between 1 × 10 3 and 1 × 10 5 CFU/g in the other three inks. Eleven bacterial isolates were identified, including spore-forming Bacillus -related species and potentially pathogenic species. Overall, this study shows that some tattoo ink products produced by manufacturers with a recall history continue to be contaminated with microorganisms. This highlights the need for ongoing monitoring and quality control of such products.

59 BASIC BIOLOGICAL SCIENCES↗

Real-time elemental analysis of liquids for process monitoring using laser-induced breakdown spectroscopy with a liquid wheel sampling approach

This article presents an engineered sampling system that used a rotating wheel to form a thin liquid layer, permitting the use of laser-induced breakdown spectroscopy (LIBS) for in situ, real-time elemental impurity quantification during liquid processing. The sampling approach was demonstrated on eight elements from across the periodic table (Na, Al, K, Ca, Ti, Sr, Mo, and Yb). Univariate and multivariate calibrations were presented for each element. The average value for percent root mean square errors of cross-validation for the multivariate models was 3.64%, highlighting the method's strong prediction accuracy. Additionally, the limits of detection for each analyte were estimated from their univariate models: Na = 0.0532, Al = 18.5, K = 0.105, Ca = 0.273, Ti = 67.7, Sr = 0.640, Mo = 22.4, and Yb = 22.9 μg mL –1 . Finally, a test in which multivariate models were used to monitor a liquid system for 80 min was performed to investigate the real-time monitoring capabilities of this liquid LIBS sampling approach. Rigorous measurements were performed to effectively predict the absence and concentrations of multiple analytes as they were spiked and diluted. This demonstration showed the feasibility of using LIBS for real-time liquid quantification models with estimated precision ≤ 8.1%. Finally, the limitations of this approach and potential future improvements are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing analytical merits of laser-induced breakdown spectroscopy of hydrogen isotopes using an orthogonal double-pulsing scheme

Accurate detection and quantification of hydrogen isotopes in solid materials are vital for diverse applications, including fusion energy, hydrogen storage, and tritium production. Laser-induced breakdown spectroscopy (LIBS) is a well established, rapid, standoff method for this purpose, but it faces challenges related to the analytical merits required for isotopic analyses. In this study, we enhance the analytical and detection capabilities of traditional single-pulse LIBS by implementing an orthogonal double pulsing approach, focusing on the analysis of a range of 2 H concentrations in Zircaloy-4 substrates (acting as a proxy for 3 H). The double-pulse experiments employed an orthogonal re-heating configuration with two nanosecond Nd:YAG lasers. We systematically evaluated critical parameters affecting the signal intensity in double-pulse LIBS, including interpulse delay, ambient gas pressure, and heating laser energy. Finally, our results demonstrate that employing an orthogonal double-pulse scheme significantly enhances 2 H α emission while minimizing line broadening and self-absorption, ultimately improving the technique’s analytical capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Polar Compounds Condensed on Particulate Matter Using Capillary Electrophoresis-Mass Spectrometry

A new analytical method to aid in the understanding of the organic carbon (OC) phase of particulate matter (PM) from advanced compression ignition (ACI) operating modes, is presented. The presence of NO2 and unburned fuel aromatics in ACI emissions, and the low exhaust temperatures that result from this low temperature combustion strategy, provide the right conditions for the formation of carboxylic acids and nitroaromatic compounds. These polar compounds contribute to OC in the PM and are not typically measured using nonpolar solvent extraction methods such as the soluble organic fraction (SOF) method. The new extraction and detection method employs capillary electrophoresis with electrospray ionization mass spectrometry (CE-ESI MS) and was specifically developed to determine polar organic compounds in the ACI PM emissions. The new method identified both nitrophenols and aromatic carboxylic acids in the ACI PM. The ACI air-fuel stratification mode and NOx emissions were found to correlate with the presence and amount of the individual polar species identified.

Lewis Sr, Samuel↗

Classification Analytics of Pu-239 and U-235 Source Signatures Using Gamma Spectral Regions

Machine learning detection methods using gamma signatures from spectral measurements of low-intensity Pu-239 and U-235 sources are studied. NaI detectors located at different distances fromthe source have been used to collect the training and independent testing data sets. The source is introduced via a shielded conduit into the facility where it is surrounded by 21 NaI detectors deployed over 6 x 6 meters area in the formation of two concentric circles and a spiral. The counts in gamma spectral regions associated with these two sources are estimated at 1 second intervals for each NaI detector, and are used as classifier features for detecting the source presence. Eight different classifiers with five basic properties — namely, smooth, non-smooth, statistical, structural, and hyper-parameter tuning — are trained and tested using the background and source measurements collected over multiple experimental runs. While the overall classifier performance improved as detectors closer to the source are used, some identically produced detectors under-performed but differently between two sources. Some classifiers achieved lower training error but their testing error based on independent measurements is higher for both sources. Overall, these results indicate significant over-fitting by these methods, and illustrate the complexity of training and selecting the machine learning methods to solve these detection problems.

Rao, Nageswara↗

Batch Scale Production of 3D Printed Extraction Sorbents Using a Low-Cost Modification to a Desktop Printer

This study reports a simple modification to a commercial resin 3D printer that significantly reduces the amount of prepolymer material needed for the production of extraction sorbents. Here, the modified printing platform is demonstrated in the printing of two imidazolium-based ionic liquid (IL) monomers. Two geometries resembling a blade-type polymeric ionic liquid (PIL) sorbent used in thin-film microextraction and a fiber-type sorbent used in solid-phase microextraction (SPME) were printed. The SPME PIL sorbents were used to extract 10 organic contaminants, including plasticizers, antimicrobial agents, UV filters, and pesticides, from water followed by high-performance liquid chromatographic (HPLC) analysis. To compare the extraction performance of the SPME sorbents, seven fibers printed with the same prepolymer composition from the same printing batch as well as different batches were evaluated. The results revealed highly reproducible extraction efficiencies for all tested sorbents with no statistical difference in their extraction performance. Method validation showed acceptable linearity ($R$ 2 > 0.92) for all analytes with limits of detection and limits of quantification ranging from 0.13 to 45 μg L –1 and 0.43 to 150 μg L –1 , respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

Parsing Weather Variability and Wildfire Effects on the Post-Fire Changes in Daily Stream Flows: A Quantile-Based Statistical Approach and Its Application

Determining wildland fire impacts on streamflow can be problematic as the hydrology in burned watersheds is influenced by post-fire weather conditions. Here, this study presents a quantile-based analytical framework for assessing fire impacts on low and peak daily flow magnitudes, while accounting for post-fire weather influences. This framework entails (a) the bootstrap method to compute the relative change in the post-fire annual flow and weather statistics, (b) double mass analysis to detect if post-fire baseflow and quick-flow yield ratios are significantly altered, and (c) a quantile regression method to parse fire effects on flow at a specific quantile. We illustrate the applicability of this analytical framework using 44 western US streams with at least 5% of their watershed area burned. Results indicate that large, high-severity burns in upland watersheds can raise the streamflow magnitude at the 0. 05 th and 0. 95 th quantiles for at least the five post-fire years. Quantile regression results show that the median fire-related increase in flow for the five post-fire years can be up to 5,000% (Standard Error; S.E. < 2%) at the 0. 05 th E quantile and 161% (S.E. < 10%) at the 0. 95 th quantile. The fire-related increase in flow was often pronounced at the 0. 05 th quantile for streams in the Pacific Northwest and California regions. The difference in fire effects on flow (at both quantiles) across streams was related to post-fire weather, pyrology, physiography, and land cover. The proposed analytical framework can be useful for detecting and quantifying fire effects on the low and peak stream flows in burned watersheds without overlapping disturbances.

54 ENVIRONMENTAL SCIENCES↗

Real-Time Screening for Uranium Enrichment by Paper Spray Ionization Mass Spectrometry for Field Applications

A rapid isotope ratio screening technique for uranium enrichment is demonstrated by utilizing paper spray ionization (PSI) high-resolution mass spectrometry (HRMS). Measurements were conducted using an ambient ionization mass spectrometer coupled to a custom-made JEOL PSI attachment apparatus, with de minimus sample preparation requirements. The current method detection limit for individual isotopes (e.g., 235 U and 238 U) is approximately 50 pg, with subsequent optimization expected to further improve U isotopic sensitivity. The PSI analytical method described herein can support rapid analysis (both in-field and in-lab screening) of isotopes-of-interest, as demonstrated by empirical differentiation of depleted uranium (DU) and low enriched uranium (LEU) analytical aliquots. Furthermore, this analytical workflow holds promise for applications in nuclear forensics, international nuclear safeguards, and nonproliferation missions.

Anions↗

Extreme Molecular Complexity Resulting in a Continuum of Carbonaceous Species in Biomass Burning Tar Balls from Wildfire Smoke

Biomass burning emits a wide range of carbonaceous particles into the atmosphere and has negative impacts on human health and the Earth’s radiative balance. Nonvolatile spherical organic aerosol particles, commonly known as tar balls, represent one of the most abundant particles in aged biomass burning smoke. However, the detailed molecular-level composition of ambient tar balls is largely unknown but critical to access their environmental impacts. Ambient aerosol samples collected during a wildfire event, which were ~90% tar balls by number fraction, were analyzed using ultrahigh resolution Orbitrap Elite mass spectrometry with four complementary ionization modes. Our results show the molecular composition of tar balls to be complex, composed of over 10,000 molecular formulas. Model estimated saturation mass concentrations and relative humidity dependent glass transition temperatures were consistent with low volatility and solid morphology as expected for tar balls. Room-temperature evaporation kinetics showed that these particles were composed of ~90% non-volatile species. The molecular complexity detected here signifies a continuum of carbonaceous species, ranging from C3 to C45 with continuous ranges of oxygenation and hydrogen saturation for each Cn. Approximately 24% of molecular formulas were estimated the be highly aromatic, which could indicate chemical compounds with negative health effects, and which may contribute to visible light absorption. The carbon continuum observed here has significant implications for the molecular characterization of atmospheric organic matter. The level of complexity detected here should not be ignored in future studies and we demonstrate that multiple analytical methods may be required to suitably interpret this complexity on a molecular level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-high SERS detection of consumable coloring agents using plasmonic gold nanostars with high aspect-ratio spikes

Solution-based SERS detection by using a portable Raman instrument has emerged as an important tool due to its simplicity, and flexibility for rapid and on-site screening of analyte molecules. However, this method has several shortcomings, including poor sensitivity especially for weak-affinity analyte molecules, where there is no close contact between the plasmonic metal surface and analyte molecule. Examples of weak-affinity molecules include pigment molecules that are commonly used as a consumable coloring agent, such as allura red (AR), and sunset yellow (SY). As high consumption of colorant agents has been shown to cause adverse effects on human health, there is a strong need to develop a simple and practical sensing system with high sensitivity for these agents. Here we present a novel, highly sensitive solution-based SERS detection method for AR, and SY by using CTAC capped gold nanostars (GNS) having different aspect ratios (GNS-2, GNS-4, and GNS-5) without utilizing any aggregating agents which can enhance SERS signal however it reduces batch to batch reproducibility. The influence of the aspect ratio of GNS on SERS properties was investigated. We have achieved a limit of detection (LOD) of AR and SY as low as 0.5 and 1 ppb, respectively by using GNS-5 with the advantages of minimal sample preparation by just mixing the analyte solution into a well plate containing GNS solution. In addition, excellent colloidal stability and reproducibility have further enhanced the applicability in real-world samples. Altogether, our results evidence that the solution-based SERS detection platform using high aspect-ratio GNS can be applied for practical application to detect pigment molecules in real samples with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method’s LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method’s main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Reservoir Temperature Estimator (RTEst): A multicomponent geothermometry tool

The Reservoir Temperature Estimator (RTEst) is a multicomponent geothermometry tool for estimating reservoir geochemical parameters including reservoir temperature, CO 2 fugacity, mass of water lost or gained, and a reaction factor. It estimates these parameters and their associated uncertainties by minimizing an objective function that is the weighted sum of squares of the saturation indices of a user-selected set of minerals believed to be equilibrated with the reservoir fluid. RTEst accomplishes these estimates by combining the geochemical modeling capabilities of The Geochemist’s Workbench® with the optimization/parameter estimation resources of PEST®. An included interface aids the user in selecting plausible mineral phases to comprise the objective function and calculates their weighting factors. The working principles of RTEst are described and its efficacy is illustrated by presenting results of its application to various geothermal fields with known conditions. These examples show RTEst can account for the alteration of ascending reservoir fluid by mineral (calcite) re-equilibration with changes in temperature, reconstruct waters with CO 2 loss, correct for the deficit of water and other volatiles (CO 2,gas , H 2 S gas ) from boiling, and determine the amount of mixing of thermal and non-thermal waters. RTEst can use data with basis species below detection limit, missing, or unreliable either by assuming equilibrium with a controlling mineral (fixed-analyte method) or by treating the analyte concentration as an optimization parameter. The inverse of variance weighting method included in RTEst provides more representative results than either the normalization or unit weighting methods. Finally, the ability of RTEst to calculate reservoir temperatures, gas fugacity, and mixing fractions demonstrates its usefulness as a tool for evaluating geothermal systems.

15 GEOTHERMAL ENERGY↗