Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “alternative fuels data center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Propane Basics

Propane powers nearly 60,000 vehicles in the United States. Fleets around the United States have successfully implemented propane vehicles in many types of applications, including school buses, shuttle buses, step vans, and law enforcement vehicles. Propane is also frequently used in off-road applications, such as forklifts, commercial landscape mowers and equipment, and other farm equipment. The advantages of propane include its domestic availability, performance, and emissions benefits.

47 OTHER INSTRUMENTATION↗

Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States

Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.

15 GEOTHERMAL ENERGY↗

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗

Development and Testing of the Glenn Research Center Visitor's Center Grid-Tied Photovoltaic Power System

The NASA Glenn Research Center (GRC) has developed, installed, and tested a 12 kW DC grid-tied photovoltaic (PV) power system at the GRC Visitor s Center. This system utilizes a unique ballast type roof mount for installing the photovoltaic panels on the roof of the Visitor s Center with no alterations or penetrations to the roof. The PV system has generated in excess of 15000 kWh since operation commenced in August 2008. The PV system is providing power to the GRC grid for use by all. Operation of the GRC Visitor s Center PV system has been completely trouble free. A grid-tied PV power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. The project transfers space technology to terrestrial use via nontraditional partners. GRC personnel glean valuable experience with PV power systems that are directly applicable to various space power systems, and provides valuable space program test data. PV power systems help to reduce harmful emissions and reduce the Nation s dependence on fossil fuels. Power generated by the PV system reduces the GRC utility demand, and the surplus power aids the community. Present global energy concerns reinforce the need for the development of alternative energy systems. Modern PV panels are readily available, reliable, efficient, and economical with a life expectancy of at least 25 years. Modern electronics has been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy of at least 25 years. Based upon the success of the GRC Visitor s Center PV system, additional PV power system expansion at GRC is under consideration. The GRC Visitor s Center grid-tied PV power system was successfully designed and developed which served to validate the basic principles described, and the theoretical work that was performed. The report concludes that grid-tied photovoltaic power systems are reliable, maintenance free, long life power systems, and are of significant value to NASA and the community.

Eichenberg, Dennis J.↗

A comparison of smartphone and infrasound microphone data from a fuel air explosive and a high explosive

For prompt detection of large (>1 kt) above-ground explosions, infrasound microphone networks and arrays are deployed at surveyed locations across the world. Denser regional and local networks are deployed for smaller explosions, however, they are limited in number and are often deployed temporarily for experiments. With the expanded interest in smaller yield explosions targeted at vulnerable areas such as population centers and key infrastructures, the need for more dense microphone networks has increased. An “attritable” (affordable, reusable, and replaceable) and flexible alternative can be provided by smartphone networks. Explosion signals from a fuel air explosive (thermobaric bomb) and a high explosive with trinitrotoluene equivalent yields of 6.35 and 3.63 kg, respectively, were captured on both an infrasound microphone and a network of smartphones. The resulting waveforms were compared in time, frequency, and time-frequency domains. The acoustic waveforms collected on smartphones produced a filtered explosion pulse due to the smartphone's diminishing frequency response at infrasound frequencies (<20 Hz) and was found difficult to be used with explosion characterization methods utilizing waveform features (peak overpressure, impulse, etc.). However, the similarities in time frequency representations and additional sensor inputs are promising for other explosion signal identification and analysis. As an example, a method utilizing the relative acoustic amplitudes for source localization using the smartphone sensor network is presented.

47 OTHER INSTRUMENTATION↗

Exploring New Ways to Classify Industries for Energy Analysis and Modeling

As the US moves closer to embracing a net zero greenhouse gas emissions position, combustion processes outside the power sector are becoming urgent concerns. Industry is an important end user of energy and relies on fossil fuels used directly for process heating and as feedstocks for a diverse range of applications. Fuel and energy use by industry is heterogeneous, meaning that even a single product group can vary broadly in its production routes and associated energy usage. In the US, the North American Industry Classification System (NAICS) serves as the basis for data collection and reporting. In turn, data based on NAICS is the foundation of most US energy modeling. Thus, the effectiveness of NAICS at representing energy use is a limiting condition for plans to improve energy efficiency and alternatives to fossil fuels in industry. Facility-level data to build more detail into heterogeneous sectors is scarce. This work explores alternative classification schemes for industry based on energy use characteristics, and provides a validation of an approach to make facility-level energy use estimates based on publicly available data from the greenhouse gas reporting program. First, several approaches to industrial taxonomies and their usefulness for industrial energy modeling are summarized. Data from Industrial Assessment Centers is analyzed using unsupervised machine learning techniques to detect clusters. Cladistics, an approach from biology, is adapted to energy and process characteristics of industries. A cladogram is presented for evolutionary directions in the iron and steel sector. Cladograms are a promising tool for constructing scenarios and summarizing directions of sectoral innovation. Finally, validation is performed for facility-level energy estimates from the US EPA Greenhouse Gas Reporting Program. This validation assists in making this data source available for use in energy modeling. Together, this work explores alternative approaches for categorizing industries in a way that aids understanding energy use, and presenting pathways for the future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low NOx Fuel-Flex Combustor Summary

Combustion and emissions testing of United Technologies Research Center’s (UTRC’s) small core combustor in NASA GRC’s CE-5 flametube test facility comprising of LTO and cruise conditions has been completed. Sufficient NOx emissions data was collected to formulate correlation equations for assessing reductions in NOx for LTO against CAEP/6 and cruise against 2005 best-in-class. Back-to-back testing of Jet-A fuel and a 50/50 blend of Jet-A with an alternative fuel demonstrated a measurable effect of fuel composition on non-volatile particulate matter emissions. Post-test analysis indicates LTO NOx emissions >80% below CAEP6 in UTRC single-sector tests of small-core N+3 combustor. Documentation describing N+3 combustor concept selected, design approach, initial flametube test & analysis results; and preferred concept recommended for higher fidelity research has also been completed. This Lean Burn combustor concept shows potential to meet/exceed NASA’s Far Term LTO NOX reduction goals, but further investigation of dynamic characteristics of the combustor concept are required to ensure good operability over the entire flight regime conditions.

Angela D Surgenor↗

Cold flow testing of the Space Shuttle Main Engine alternate turbopump development high pressure fuel turbine model

NASA's Marshall Space Flight Center has established a cold airflow turbine test program to experimentally determine the performance of liquid rocket engine turbopump drive turbines. Testing of the SSME alternate turbopump development (ATD) fuel turbine was conducted for back-to-back comparisons with the baseline SSME fuel turbine results obtained in the first quarter of 1991. Turbine performance, Reynolds number effects, and turbine diagnostics, such as stage reactions and exit swirl angles, were investigated at the turbine design point and at off-design conditions. The test data showed that the ATD fuel turbine test article was approximately 1.4 percent higher in efficiency and flowed 5.3 percent more than the baseline fuel turbine test article. This paper describes the method and results used to validate the ATD fuel turbine aerodynamic design. The results are being used to determine the ATD high pressure fuel turbopump (HPFTP) turbine performance over its operating range, anchor the SSME ATD steady-state performance model, and validate various prediction and design analyses.

Gaddis, Stephen W.↗

The E-3 Test Facility at Stennis Space Center: Research and Development Testing for Cryogenic and Storable Propellant Combustion Systems

This paper will provide the reader a broad overview of the current upgraded capabilities of NASA's John C. Stennis Space Center E-3 Test Facility to perform testing for rocket engine combustion systems and components using liquid and gaseous oxygen, gaseous and liquid methane, gaseous hydrogen, hydrocarbon based fuels, hydrogen peroxide, high pressure water and various inert fluids. Details of propellant system capabilities will be highlighted as well as their application to recent test programs and accomplishments. Data acquisition and control, test monitoring, systems engineering and test processes will be discussed as part of the total capability of E-3 to provide affordable alternatives for subscale to full scale testing for many different requirements in the propulsion community.

Pazos, John T.↗

Supplementary Spin Tests of a 1/20-Scale Model of the Bell XP-39E Airplane

As a result of the loss of the first XP-39E airplane due to an uncontrolled spin, and at the request of the War Department received in their letter to the NACA, March 31, 1942, additional tests have been made of the corresponding 1/20-scale spin-tunnel model. Tests were made for the normal full load condition and also for the loading condition corresponding to that of the airplane at the time of the crash, that Is, with guns, ammunition, and half of the fuel removed from the wings. The model tests were made with the tail arrangement corresponding to that of the airplane at the time of the crash, as well as with numerous modified tail and contour arrangements In an attempt to evolve satisfactory recovery characteristics. The tests were started on April 2, 1942, and completed in approximately two weeks, with the development of several alternate tail arrangements giving reasonably satisfactory recoveries for normal spinning control configuration. The tests were witnessed by Mr. Melvin Shorr, of the Materiel Center at Wright Field, and Mr. Paul C. Emmons, of the Bell Aircraft Corporation, to whom records of the test data were furnished. Colonel H. P. Swofford, of the Materiel Center, Wright Field, also witnessed part of the tests. A preliminary report of the results of the tests has been forwarded to the Materiel Command at Wright Field. A brief check of the parachute installation for the airplane was also made.

A I Neihouse↗

An analysis of alcohol compression ignition strategies on different engine platforms

Strategies that enable ignition of the low cetane alcohol fuels (methanol and ethanol) include intake heating (direct or via hot residual trapping), increased compression ratio (CR), multi-injection strategies, ignition enhancers, and active prechambers. The literature consistently shows alcohol compression ignition (CI) is more efficient than diesel at high loads irrespective of ignition strategy but shows contradictory results at low loads. To understand this, this work combines data from four different engine platforms ranging from a displaced volume of 0.4 to 2.1 L/cyl. using different alcohol CI ignition strategies. Using modeling to support experimental analysis, alcohol-specific efficiency penalties are highlighted to inform alcohol combustion system development. The alcohols’ lower energy density means more fuel must be injected near top dead center to achieve a given load, increasing the relative penalty of sensible/latent heating. Pilot injections help reduce this penalty. Intake heating incurs both a heat transfer penalty and a thermodynamic penalty due to a reduced ratio of specific heats during compression. A strategy that combines elevated CR, large pilot injections, and ignition enhancers can avoid this penalty. Alternatively, a prechamber strategy can achieve this without changing the CR, nor needing ignition enhancers in the fuel. At low loads, diesel burns in a partially premixed mode characterized by high burn rates and low heat losses, reducing alcohol-specific combustion benefits. Alcohol CI on the light-duty platform showed abnormally high heat transfer over diesel compared to other platforms, favoring a more premixed/partially premixed strategy despite a combustion efficiency tradeoff.

33 ADVANCED PROPULSION SYSTEMS↗

Alternative Fuels Research Laboratory

NASA Glenn has invested over $1.5 million in engineering, and infrastructure upgrades to renovate an existing test facility at the NASA Glenn Research Center (GRC), which is now being used as an Alternative Fuels Laboratory. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch (F-T) synthesis and thermal stability testing. This effort is supported by the NASA Fundamental Aeronautics Subsonic Fixed Wing project. The purpose of this test facility is to conduct bench scale F-T catalyst screening experiments. These experiments require the use of a synthesis gas feedstock, which will enable the investigation of F-T reaction kinetics, product yields and hydrocarbon distributions. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor for catalyst activation studies. Product gas composition and performance data can be continuously obtained with an automated gas sampling system, which directly connects the reactors to a micro-gas chromatograph (micro GC). Liquid and molten product samples are collected intermittently and are analyzed by injecting as a diluted sample into designated gas chromatograph units. The test facility also has the capability of performing thermal stability experiments of alternative aviation fuels with the use of a Hot Liquid Process Simulator (HLPS) (Ref. 1) in accordance to ASTM D 3241 "Thermal Oxidation Stability of Aviation Fuels" (JFTOT method) (Ref. 2). An Ellipsometer will be used to study fuel fouling thicknesses on heated tubes from the HLPS experiments. A detailed overview of the test facility systems and capabilities are described in this paper.

Surgenor, Angela D.↗

1-Watt Radioisotope Power System for Small Spacecraft

A variety of mission concepts have been studied by NASA and the U. S. Department of Energy that would utilize low power Radioisotope Power Systems (RPS) for small probes, landers, rovers, and communication repeaters. These missions would contain science measuring instruments that could be distributed across planetary surfaces for operation in temporarily or permanently shadowed regions. High efficiency dynamic RPS could be mission enabling for science measurements on the moon, such as collecting real-time, event-based, or cumulative space radiation measurements including primary galactic cosmic rays (GCR), solar particle events (SPE), and secondary particles liberated during atmospheric and/or surface reactions. Small RPS would use fractional versions of the General Purpose Heat Source (GPHS) or Light Weight Radioisotope Heater Units (LWRHU), to heat the power conversion technologies. Capable of three to four times higher conversion efficiency than static technologies, dynamic RPS would provide an equal amount of power using less fuel or more power using an equal amount of fuel. Providing spacecraft with more power could decrease duty cycling of basic functions and increase the quality and abundance of science data. Low power Stirling convertors are being developed at NASA Glenn Research Center (GRC) to provide future micro spacecraft with electrical power by converting heat from one or more LWRHUs. An initial concept would convert eight Watts of heat to one Watt of electrical power output for science instruments and communication. The initial design, called Small Stirling Technology Exploration Power (smallSTEP), is 11 cm diameter X 32 cm long, weighs around 3 kg, and could be used to charge batteries or capacitors for higher power burst usage. Development of the 1-watt RPS includes maturation of a Stirling engine and linear alternator, an electronics controller, and an evacuated metal foil insulation package. Test hardware and facilities are being prepared for initial demonstration of the subassemblies in a laboratory environment.

Wilson, Scott↗

Evaluation of Impinging Stream Vortex Chamber Concepts for Liquid Rocket Engine Applications

To pursue technology developments for future launch vehicles, NASA/Marshall Space Flight Center (MSFC) is examining vortex chamber concepts for liquid rocket engine applications. Past studies indicated that the vortex chamber schemes potentially have a number of advantages over conventional chamber methods. Due to the nature of the vortex flow, relatively cooler propellant streams tend to flow along the chamber wall. Hence, the thruster chamber can be operated without the need of any cooling techniques. This vortex flow also creates strong turbulence, which promotes the propellant mixing process. Consequently, the subject chamber concepts not only offer system simplicity, but also enhance the combustion performance. Test results have shown that chamber performance is markedly high even at a low chamber length-to-diameter ratio (LD). This incentive can be translated to a convenience in the thrust chamber packaging. Variations of the vortex chamber concepts have been introduced in the past few decades. These investigations include an ongoing work at Orbital Technologies Corporation (ORBITEC). By injecting the oxidizer tangentially at the chamber convergence and fuel axially at the chamber head end, Knuth et al. were able to keep the wall relatively cold. A recent investigation of the low L/D vortex chamber concept for gel propellants was conducted by Michaels. He used both triplet (two oxidizer orifices and one fuel orifice) and unlike impinging schemes to inject propellants tangentially along the chamber wall. Michaels called the subject injection scheme an Impinging Stream Vortex Chamber (ISVC). His preliminary tests showed that high performance, with an Isp efficiency of 9295, can be obtained. MSFC and the U. S. Army are jointly investigating an application of the ISVC concept for the cryogenic oxygen/hydrocarbon propellant system. This vortex chamber concept is currently tested with gel propellants at AMCOM at Redstone Arsenal, Alabama. A version of this concept for the liquid oxygen (LOX) hydrocarbon fuel (RP-1) system has been derived from the one for the gel propellant. An unlike impinging injector was employed to deliver the propellants to the chamber. MSFC is also conducting an alternative injection scheme, called the chasing injector, associated with this vortex chamber concept. In this injection technique, both propellant jets and their impingement point are in the same chamber cross-sectional plane. Long duration tests (approximately up to 15 seconds) will be conducted on the ISVC to study the thermal effects. This paper will report the progress of the subject efforts at NASA Marshall Space Flight Center. Thrust chamber performance and thermal wall compatibility will be evaluated. The chamber pressures, wall temperatures, and thrust will be measured as appropriate. The test data will be used to validate CFD models, which, in turn, will be used to design the optimum vortex chambers. Measurements in the previous tests showed that the chamber pressures vary significantly with radius. This is due to the existence of the vortices in the chamber flow field. Hence, the combustion efficiency may not be easily determined from chamber pressure. For this project, measured thrust data will be collected. The performance comparison will be in terms of specific impulse efficiencies. In addition to the thrust measurements, several pressure and temperature readings at various locations on the chamber head faceplate and the chamber wall will be made. The first injector and chamber were designed and fabricated based on the available data and experience gained during gel propellant system tests by the U.S. Army. The alternate injector for the ISVC was also fabricated. Hot-fire tests of the vortex chamber are about to start and are expected to complete in February of 2003 at the TS115 facility of MSFC.

Trinh, Huu P.↗

Using Life Cycle Assessment to Inform CBI Research Priorities

Life cycle assessment (LCA) is used within the Center for Bioenergy Innovation (CBI) to provide information about how feedstock agricultural practices, supply chain logistics, biorefinery operating parameters, and the slate of biofuels and products contribute to environmental impacts, and how CBI's research priorities can result in less impactful biofuel supply chains. This poster provides an overview of the LCA methodology used within CBI and focuses on data needs in general and from other CBI teams. Assumptions and simplifications within biofuel LCA studies are reviewed, including options for modeling multi-functional processes. Calculation details for life cycle environmental impacts used within CBI - global warming potential, cumulative energy demand, and the Available Water Remaining indicator - are presented, along with a discussion of carbon intensity as an alternative metric for evaluating sustainable aviation fuel and other biofuels. The process of interpreting impact results to guide research priorities is discussed, with examples drawn from CBI's upcoming manuscript on switchgrass yield and cell wall composition.

bioenergy↗

Computational Thermochemistry of Jet Fuels and Rocket Propellants

The design of new high-energy density molecules as candidates for jet and rocket fuels is an important goal of modern chemical thermodynamics. The NASA Glenn Research Center is home to a database of thermodynamic data for over 2000 compounds related to this goal, in the form of least-squares fits of heat capacities, enthalpies, and entropies as functions of temperature over the range of 300 - 6000 K. The chemical equilibrium with applications (CEA) program written and maintained by researchers at NASA Glenn over the last fifty years, makes use of this database for modeling the performance of potential rocket propellants. During its long history, the NASA Glenn database has been developed based on experimental results and data published in the scientific literature such as the standard JANAF tables. The recent development of efficient computational techniques based on quantum chemical methods provides an alternative source of information for expansion of such databases. For example, it is now possible to model dissociation or combustion reactions of small molecules to high accuracy using techniques such as coupled cluster theory or density functional theory. Unfortunately, the current applicability of reliable computational models is limited to relatively small molecules containing only around a dozen (non-hydrogen) atoms. We propose to extend the applicability of coupled cluster theory- often referred to as the 'gold standard' of quantum chemical methods- to molecules containing 30-50 non-hydrogen atoms. The centerpiece of this work is the concept of local correlation, in which the description of the electron interactions- known as electron correlation effects- are reduced to only their most important localized components. Such an advance has the potential to greatly expand the current reach of computational thermochemistry and thus to have a significant impact on the theoretical study of jet and rocket propellants.

Crawford, T. Daniel↗

Life-Cycle Assessments of Selected NASA Ground-Based Test Facilities

In the past two years, two separate facility-specific life cycle assessments (LCAs) have been performed as summer student projects. The first project focused on 13 facilities managed by NASA s Aeronautics Test Program (ATP), an organization responsible for large, high-energy ground test facilities that accomplish the nation s most advanced aerospace research. A facility inventory was created for each facility, and the operational-phase carbon footprint and environmental impact were calculated. The largest impacts stemmed from electricity and natural gas used directly at the facility and to generate support processes such as compressed air and steam. However, in specialized facilities that use unique inputs like R-134a, R-14, jet fuels, or nitrogen gas, these sometimes had a considerable effect on the facility s overall environmental impact. The second LCA project was conducted on the NASA Ames Arc Jet Complex and also involved creating a facility inventory and calculating the carbon footprint and environmental impact. In addition, operational alternatives were analyzed for their effectiveness at reducing impact. Overall, the Arc Jet Complex impact is dominated by the natural-gas fired boiler producing steam on-site, but alternatives were provided that could reduce the impact of the boiler operation, some of which are already being implemented. The data and results provided by these LCA projects are beneficial to both the individual facilities and NASA as a whole; the results have already been used in a proposal to reduce carbon footprint at Ames Research Center. To help future life cycle projects, several lessons learned have been recommended as simple and effective infrastructure improvements to NASA, including better utility metering and data recording and standardization of modeling choices and methods. These studies also increased sensitivity to and appreciation for quantifying the impact of NASA s activities.

Sydnor, George Honeycutt↗

Kansas City, Missouri, Streetlight Electric Vehicle Charging: Strategies and challenges for site selection of streetlight electric vehicle infrastructure in Kansas City, Missouri (Final Report)

Public streetlight charging, whether on streets in central business districts or residential areas, provides easy charging access for apartment residents and homeowners alike. While most electric vehicle (EV) drivers charge at home, they do so in garages or on driveways they own. For renters and residents of multifamily housing (MFH), however, this may not be an option. EVs have a lower cost of ownership compared to conventional vehicles, and a used EV may be an affordable option for a lower-income household. But without easy access to charging, even a low-cost used EV may not be an option for a prospective buyer. An affordable curbside charging network has the potential to expand EV adoption into neighborhoods that have to date seen minimal interest and uptake of the technology and associated charging infrastructure. Streetlight charging networks can provide an economical, scalable, and effective approach to providing equitable and convenient charging. Metropolitan Energy Center (MEC) is dedicated to the mission of creating resource efficiency, environmental health, and economic vitality in the Kansas City region and beyond. Since 1983, MEC has provided resources, outreach, and training to make alternative fuels and energy efficiency commonplace. MEC led a streetlight charging pilot project that installed limited EV charging infrastructure on the streetlight system in Kansas City, Missouri, to demonstrate and test the benefits of curbside charging for EVs at existing on-street parking locations. The project aimed to cost-effectively expand the charging network in Kansas City to support residential charging and provide infrastructure in one or more charging deserts throughout the city. This pilot evaluates the impact and overall success of streetlight charging based on community feedback, utilization of charging infrastructure, technical feasibility, and cost. The project has pursued a data- and community-driven site selection process designed to identify sites with high demand and high opportunity for EV charging. This project was funded by the U.S. Department of Energy (DOE) and awarded to MEC through a competitive proposal process. The novelty and complexity of this project required an organization that could facilitate collaboration across levels of government, community members, and industry partners. For the past 25 years, through Kansas City Regional Clean Cities, MEC has worked with numerous public and private fleets on a variety of projects to improve the environmental performance and efficiency of the regional vehicle fleet. To advance affordable, efficient, and clean transportation efforts, DOE Clean Cities and Communities coalitions create local networks of public and private sector stakeholders and engage communities. Rooted within their local communities, the coalitions serve as experts and ambassadors, bringing to bear the collective knowledge, experience, and practical know-how of the entire network from within DOE, its national laboratories, and diverse stakeholders in the field. MEC and its project partners made in-kind contributions to leverage federal dollars for the benefit of the Kansas City community. Findings from this project will help determine the best applications for streetlight charging technologies to maximize funding impact and serve community needs. The team evaluated locations based on expected charging demand, technical feasibility, safety considerations, and enhanced charging network siting needs. Throughout the project, the team gathered feedback and evaluated ways to make public charging for EVs available to all community members. The insights will help Kansas City and other communities streamline future efforts to support EV drivers through public charging in the city right-of-way. Furthermore, this project will inform citywide guidance for future installations. MEC is committed to a transparent and publicly accessible approach that encourages the collaborative evaluation of streetlight charging. The project has engaged the community to proactively identify and evaluate the benefits and impacts of streetlight charging. It was a priority for the project to ensure the benefits of this pilot are distributed equitably to all members of the Kansas City community and that new charging opportunities and associated resources are available in diverse neighborhoods across the city. The charging infrastructure supports an affordable curbside charging network that will enable more drivers to choose EVs and provide easy charging access for all community members interested in driving an EV. The community feedback received through this project informed future resources and opportunities to make EVs more accessible to all members of the Kansas City community. MEC worked with several community partners on this project, including Missouri University of Science and Technology (MST), Pennsylvania State University (Penn State), the National Renewable Energy Laboratory (NREL); the city of Kansas City, Missouri; Evergy; Black and McDonald (B&M); LilyPad EV; EVNoire; and Westside Housing Organization (WHO). Project partners contributed to the cost match required for DOE grants through capital expenditures, personnel, and other in-kind contributions. Detailed descriptions of project team organizations can be found in Appendix A. Project Partners. Analysts at NREL and MST/PennState developed site maps based on demand and equity considerations. MEC conducted outreach to community members to garner input on project design and site selection, and received approval from the Missouri Public Service Commission (PSC) for Evergy’s EV charging station ownership. MEC worked with all partners to gather additional siting criteria and developed a site selection evaluation checklist, and partners conducted site visits to proposed installation sites. Next, B&M, Evergy, and the city executed all site agreements, conducted site-specific engineering design, acquired associated permits, and issued notices to proceed site by site or in small batches. Finally, from January to April 2023, the project team installed 23 EV charging stations built on Kansas City’s streetlight system in six council districts. Evergy will own, operate, and monitor the stations for 10 years, sharing charging data with MEC for at least 1 year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗