Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adsorption pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

Lunar-surface UV Photometric Investigation of Exospheres (LUPINE): Thermal Modeling of Payload in a Relevant Daylit Environment

Direct upward remote sensing of the moon’s exosphere from a surface vantage can address production of water-related lunar volatiles as well as their exospheric loss, ballistic transport, and ultimate adsorption in permanently shadowed regions (PSRs). Far UV (FUV) dayside measurements of atomic oxygen, liberated from regolith by energetic solar protons and micrometeorite impact, can provide critical insight into the endogenic lunar water cycle by constraining total column density [O] at site of production. A notional Lunar-surface UV Photometric Investigation of Exospheres (LUPINE) instrument is designed to exploit solar-pumped atomic oxygen fluorescence at 130.4-nm, in a manner similar to the Apollo 17 UV Spectrometer (UVS) experiment [Fastie 1973; Feldman and Morrison, 1991] and the LRO Lyman-alpha Mapping Project (LAMP) spectrograph [Cook et al., 2013], by implementing a zenith-directed FUV photometer from the lunar surface at low (± 10°) selenographic latitude during the lunar day. Atomic oxygen production from solar energetic particle impact sources is thought to maximize in near solar noon [Sarantos et al., 2012], and the lander-embedded zenith-directed LUPINE photometer, in contrast to UVS and LAMP twilight measurements from orbit, can potentially capture the full column abundance of lunar regolith liberated oxygen. Herein we describe adaptation of FUV reflective optics, pulse-counting electronics, and scattered-light-suppression technologies developed for LEO FUV photometry for the challenging thermal environment of the daylit lunar surface. Preliminary thermal modeling and TVAC measurements of heritage FUV photometer components suggests that, if allowed to shed ~8W of waste heat into the bus of a reference Commercial Lunar Payload Services (CLPS) lander, the LUPINE photometer will be kept sufficiently cool to limit dark current to less than 20 counts/s. This level of dark signal enables an OI 130.4-nm 3-sigma detection threshold of ~1 mR for assumed 2-hour integrations.

Lunar UV Photometer↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

Ionic silver (Ag+) biocide is a leading candidate to provide residual microbial control in spacecraft potable water systems, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. One approach to resolve this problem is the coating of metal surfaces with an inert barrier film. In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316Ltubing under static immersion. In such conditions, parylene-C and -AF4 coatings have shown excellent Ag+loss mitigation and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we report on our work to investigate the performance of parylene-C barrier coatings, under more challenging and realistic conditions, in order to evaluate potential suitability for use. The resilience and associated Ag+ loss with Parylene-C coating on½” (12.7 mm)316L tubing and fittings under medium-term immersion and repeated fitting dis/reassembly were investigated. Potential mechanical challenges to barrier coatings in spacecraft potable water systems were investigated, with two main focuses being identified: liquid flow/pressure cycling in tubing and cyclic operation of bellows in positive-expulsion storage tanks. Two corresponding testbeds for experimental characterization of coating performance were developed. In the Flow/Pressure Testbed System, Ag+ solution will be pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution will be cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. The design and operation of these testbeds are described. Finally, the Ag+ adsorption and saturation behaviors of Kalrez and Viton, for potential use as seal materials in fittings and other connections, were characterized in limited experiments.

mitigation↗

Measurement and Control of Oxygen Partial Pressure in an Electrostatic Levitator

Recently the NASA Marshall Space Flight Center electrostatic levitation (ESL) laboratory has been upgraded to include an oxygen control system. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, at elevated temperatures, theoretically in the range from 10(exp -36) to 10(exp 0) bar. The role of active surface agents in liquid metals is fairly well known; however, published surface tension data typically has large scatter, which has been hypothesized to be caused by the presence of oxygen. The surface tension of metals is affected by even a small amount of adsorption of oxygen. It has even been shown that oxygen partial pressures may need to be as low as 10(exp -24) bar to avoid oxidation. While electrostatic levitation is done under high vacuum, oxide films or dissolved oxygen may have significant effects on materials properties, such as surface tension and viscosity. Therefore, the ability to measure and control the oxygen partial pressure within the chamber is highly desirable. The oxygen control system installed at MSFC contains a potentiometric sensor, which measures the oxygen partial pressure, and an oxygen ion pump. In the pump, a pulse-width modulated electric current is applied to yttrium-stabilized zirconia, resulting in oxygen transfer into or out of the system. Also part of the system is a control unit, which consists of temperature controllers for the sensor and pump, PID-based current loop for the ion pump, and a control algorithm. This system can be used to study the effects of oxygen on the thermophysical properties of metals, ceramics, glasses, and alloys. It can also be used to provide more accurate measurements by processing the samples at very low oxygen partial pressures. The oxygen control system will be explained in more detail and an overview of its use and limitations in an electrostatic levitator will be described. Some preliminary measurements have been made, and the results to date will be provided.

SanSoucie, Michael P.↗

The Use of the Molecular Adsorber Coating Technology to Mitigate Vacuum Chamber Contamination During Pathfinder Testing for the James Webb Space Telescope

As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

molecular contamination↗

Outgassing measurements of bare and magnetite-coated low-carbon steel vacuum chambers

The outgassing properties of bare and magnetite-coated AISI 1020 low-carbon steel vacuum chambers were evaluated to establish material selection criteria for extreme high vacuum applications, namely, to explore the possibility of using these materials to build next-generation spin-polarized photoelectron guns. Water outgassing measurements using the throughput method revealed that the magnetite-coated chamber exhibited five times lower outgassing at room temperature prior to baking, but this advantage disappears after 80 °C baking. Hydrogen outgassing measurements demonstrated significant differences after intensive heat treatment: the bare low-carbon steel vacuum chamber achieved a specific outgassing rate of 9.6 × 10 −16 Torr L s −1 cm −2 after 400 °C/50 h bake plus additional heat treatment at lower temperatures, 25 times lower than the magnetite-coated low-carbon steel chamber. Residual gas analysis showed >99% hydrogen composition after heat treatment for both materials, with carbon species below detection limits for bare low-carbon steel versus 0.8% for magnetite-coated surfaces. These measurements indicate that properly conditioned bare low-carbon steel can achieve the <10 −12 Torr pressures required for next-generation spin-polarized photogun applications. In conclusion, the paper includes various analysis techniques intended to explain observed behaviors: isotherm analysis of pump-down plots, Arrhenius analysis of hydrogen outgassing rate data, and residual gas composition tracking.

Adsorption isotherm↗

Membrane-Based Gas Traps for Ammonia, Freon-21, and Water Systems to Simplify Ground Processing

Gas traps are critical for the smooth operation of coolant loops because gas bubbles can cause loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and blockage of passages to remote systems. Coolant loops are ubiquitous in space flight hardware, and thus there is a great need for this technology. Conventional gas traps will not function in micro-gravity due to the absence of buoyancy forces. Therefore, clever designs that make use of adhesion and momentum are required for adequate separation, preferable in a single pass. The gas traps currently used in water coolant loops on the International Space Station are composed of membrane tube sets in a shell. Each tube set is composed of a hydrophilic membrane (used for water transport and capture of bubbles) and a hydrophobic membrane (used for venting of air bubbles). For the hydrophilic membrane, there are two critical pressures, the pressure drop and the bubble pressure. The pressure drop is the decrease in system pressure across the gas trap. The bubble pressure is the pressure required for air bubbles to pass across the water filled membrane. A significant difference between these pressures is needed to ensure complete capture of air bubbles in a single pass. Bubbles trapped by the device adsorb on the hydrophobic membrane in the interior of the hydrophilic membrane tube. After adsorption, the air is vented due to a pressure drop of approximately 1 atmosphere across the membrane. For water systems, the air is vented to the ambient (cabin). Because water vapor can also transport across the hydrophobic membrane, it is critical that a minimum surface area is used to avoid excessive water loss (would like to have a closed loop for the coolant). The currently used gas traps only provide a difference in pressure drop and bubble pressure of 3-4 psid. This makes the gas traps susceptible to failure at high bubble loading and if gas venting is impaired. One mechanism for the latter is when particles adhere to the hydrophobic membrane, promoting formation of a water layer about it that can blind the membrane for gas transport (Figure 1). This mechanism is the most probable cause for observed failures with the existing design. The objective of this project was to devise a strategy for choosing new membrane materials (database development and procedure), redesign of the gas trap to mitigate blinding effects, and to develop a design that can be used in ammonia and Freon-21 coolant loops.

Ritchie, Stephen M. C.↗