Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Xenon Isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evidence of an Extended Period of Aqueous Alteration on the Bennu Parent Body Revealed By I-Xe Analyses

NASA’s OSIRIS-REx mission delivered to Earth 121.6 g of regolith material from asteroid Bennu on 24th September 2023. We report multi-step laser pyrolysis xenon isotopic analysis to investigate the I-Xe system in individual particles separated from aggregate material (a mixture of small particles of undefined lithology). The high sensitivity of the RELAX mass spectrometer allows us to observe small excesses of individual isotopes and separate out different components, which may not be possible using a conventional noble gas mass spectrometer. The temperature resolution of RELAX is sufficient to seek an I-Xe isochron from step heating analysis of a sample mass <100 μg, which can contribute to our understanding of the nature and timing of aqueous alteration on Bennu’s parent body. We also aim to better estimate and understand the iodine concentration of CI chondrite-like material.

S A Crowther

Theoretical investigation of isotopic anomaly of xenon in carbonaceous chondrites and other terrestrial and extra-terrestrial samples

The composition of Xe released from carbonaceous chondrites between 600 and 1000 C, particularly its isotopic trapped forms, is analyzed. Data show trapped Xe to have the following forms: Xe-124, 126, 130, 131, 132, 134, and 136. Attempts were also made to explain the Xe anomaly by mass fractionation as well as determine the relationship between metoritic trapped Xe and solar Xe.

Sabu, D. D.

Lunar trapped xenon

Evidence is presented for the presence in Apollo 16 light matrix breccias of trapped xenon which is isotopically similar to terrestrial xenon. This trapped component is predominantly released above 900 C, together with cosmic ray produced spallation gases. The relative abundances of Ar, Kr, and Xe are distinct from both solar and terrestrial patterns. Terrestrial-type xenon has so far been observed in both Apollo 14 and 16 breccias.

Lightner, B. D.

Barium isotopes in Allende meteorite - Evidence against an extinct superheavy element

Carbon and chromite fractions from the Allende meteorite that contain isotopically anomalous xenon-131 to xenon-136 (carbonaceous chondrite fission or CCF xenon) at up to 5 x 10 to the 11th atoms per gram show no detectable isotopic anomalies in barium-130 to barium-138. This rules out the possibility that the CCF xenon was formed by in situ fission of an extinct superheavy element. Apparently the CCF xenon and its carbonaceous carrier are relics from stellar nucleosynthesis.

Lewis, R. S.

Xenon Fractionation and Archean Hydrogen Escape

Xenon is the heaviest gas found in significant quantities in natural planetary atmospheres. It would seem the least likely to escape. Yet there is more evidence for xenon escape from Earth than for any element other than helium and perhaps neon. The most straightforward evidence is that most of the radiogenic Xe from the decay of (129)I (half-life 15.7 Myr) and (244)Pu (half-life 81 Myr) that is Earth's birthright is missing. The missing xenon is often attributed to the impact erosion of early atmospheres of Earth and its ancestors. It is obvious that if most of the radiogenic xenon were driven off by impacts, most of the rest of the atmophiles fared the same fate. The other line of evidence is in the nonradiogenic isotopes of xenon and its silent partner, krypton. Atmospheric xenon is strongly mass fractionated (at about 4% per amu) compared to any known solar system source (Figure 1). This is in stark contrast to krypton, which may not be fractionated at all: atmospheric Kr is slightly heavier than solar Kr (at about 0.5% per amu), but it is the same as in carbonaceous chondrites. Nonradiogenic xenon is also under abundant relative to krypton (the so-called "missing xenon" problem). Together these observations imply that xenon has been subject to fractionating escape and krypton not.

magnetic fields

A statistical approach to screening isotopic signatures in monitoring for underground nuclear explosions

The ability to differentiate between atmospheric radionuclide signatures from underground nuclear explosions (UNEs) and signals from other sources, such as medical isotope-production facilities and nuclear reactors, can be critical to the detection and monitoring of unannounced, low-yield nuclear events. Signatures having anomalously high amplitudes, compared to background levels, remain the best indicator in screening for a UNE. However, isotopic composition can further validate a suspected UNE signature, but separation from any atmospheric background composition is first necessary. To date, evaluating the challenges of performing this separation has typically involved comparing an observed background with a highly idealized deterministic model of radioxenon signature production by a UNE that does not consider the influence of post-detonation chemical/physical processes in the detonation cavity or the subsequent gas transport mechanisms that can also affect the isotopic composition of the detected gas signature. In addition, purely deterministic models, as previously employed, overlook the uncertainty inherent in estimating critical parameters characterizing the UNE and its detonation environment. In this paper, we create detailed, multi-parameter models of radionuclide evolution using the widely accepted England and Rider post-detonation radionuclide decay-chain network coupled to detailed models simulating physical production and transport processes affecting the gas signature. Because these models are governed by uncertain parameters including barometric fluctuations, realistic ranges of variation for each of the parameters influencing isotopic composition are then defined. A Latin-Hypercube sampling approach is used to obtain a random distribution of isotopic production and gas transport results associated with a given value of each parameter. We apply these results to background histories of two stations, one providing 4-isotope background measurements and the other providing two-isotope measurements associated with the 2013 DPRK announced UNE.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P

A first roadmap for kryptology

Studies of the complex variations of the isotopic composition of xenon in the solar system have been christened 'xenology'. In the title of the present investigation, the word 'kryptology' is employed to indicate the primary objective of the reported studies. This objective is related to the prediction of the isotopic composition of krypton which comes from a number of specific locations of a supernova in association with the isotopic compositions of xenon from these locations. Krypton is a logical candidate for testing the stellar theory on geochemical grounds, taking into account also the point of view of nucleosynthesis, because the isotopes of xenon and krypton are formed by the same thermonuclear processes in stars. The data and arguments presented in the investigation show that the treatment by Heymann and Dziczkaniec (1979), although not wrong, is too simplistic, because it has ignored the possibility of holdup and arrest in Xe network.

Heymann, D.

In Situ Measurement of Atmospheric Krypton and Xenon on Mars with Mars Science Laboratory

Mars Science Laboratorys Sample Analysis at Mars (SAM) investigation has measured all of the stable isotopes of the heavy noble gases krypton and xenon in the martian atmosphere, in situ, from the Curiosity Rover at Gale Crater, Mars. Previous knowledge of martian atmospheric krypton and xenon isotope ratios has been based upon a combination of the Viking missions krypton and xenon detections and measurements of noble gas isotope ratios in martian meteorites. However, the meteorite measurements reveal an impure mixture of atmospheric, mantle, and spallation contributions. The xenon and krypton isotopic measurements reported here include the complete set of stable isotopes, unmeasured by Viking. The new results generally agree with Mars meteorite measurements but also provide a unique opportunity to identify various non-atmospheric heavy noble gas components in the meteorites. Kr isotopic measurements define a solar-like atmospheric composition, but deviating from the solar wind pattern at 80Kr and 82Kr in a manner consistent with contributions originating from neutron capture in Br. The Xe measurements suggest an intriguing possibility that isotopes lighter than 132Xe have been enriched to varying degrees by spallation and neutron capture products degassed to the atmosphere from the regolith, and a model is constructed to explore this possibility. Such a spallation component, however, is not apparent in atmospheric Xe trapped in the glassy phases of martian meteorites.

Conrad, P. G.

A target for production of radioxenons

A liquid cesium target has been developed which permits the production and identification of the neutron deficient isotopes of xenon. The thick target yields of Xe-127 and Xe-129 m were measured for proton energies between 28 and 40 MeV. Production of Xe-129 m, as indicated by the presence of a 196 keV line in the gamma ray spectra, occurred at all proton energies; Xe-127 was produced at proton energies above 33 MeV. Both accumulated on the target with the same time constant, and the cross sections were comparable in magnitude. The radioxenons were removed from the target by a stream of carrier gas so that chemical separation was unnecessary.

Blue, J. W.

Anomalous Xenon in the Precambrian Nuclear Reactor in Okelobondo (Gabon): A Possible Connection to the Fission Component in the Terrestrial Atmosphere

Some CFF-Xe (Chemically Fractionated Fission Xenon), whose isotopic composition is established by simultaneous decay and migration of radioactive fission products, is probably present in the Earth's lithosphere, a conclusion based on available Xe data from various crustal and mantle rocks . Our recent isotopic analysis of Xe in alumophosphate from zone 13 of Okelobondo (southern extension of Oklo), along with the independent estimation of the isotopic composition of atmospheric fission Xe , supports the hypothesis that CFF-Xe was produced on a planetary scale. Additional information is contained in the original extended abstract.

Meshik, A. P.

Measuring surface-area-to-volume ratios in soft porous materials using laser-polarized xenon interphase exchange nuclear magnetic resonance

We demonstrate a minimally invasive nuclear magnetic resonance (NMR) technique that enables determination of the surface-area-to-volume ratio (S/V) of soft porous materials from measurements of the diffusive exchange of laser-polarized 129Xe between gas in the pore space and 129Xe dissolved in the solid phase. We apply this NMR technique to porous polymer samples and find approximate agreement with destructive stereological measurements of S/V obtained with optical confocal microscopy. Potential applications of laser-polarized xenon interphase exchange NMR include measurements of in vivo lung function in humans and characterization of gas chromatography columns.

Non-NASA Center

Probing porous media with gas diffusion NMR

We show that gas diffusion nuclear magnetic resonance (GD-NMR) provides a powerful technique for probing the structure of porous media. In random packs of glass beads, using both laser-polarized and thermally polarized xenon gas, we find that GD-NMR can accurately measure the pore space surface-area-to-volume ratio, S/V rho, and the tortuosity, alpha (the latter quantity being directly related to the system's transport properties). We also show that GD-NMR provides a good measure of the tortuosity of sandstone and complex carbonate rocks.

NASA Discipline Environmental Health

Evaluation of carrier agents for hyperpolarized xenon MRI

Several biocompatible carrier agents, in which xenon is highly soluble and has a long T(1), were tested, and injected in living rats. These included saline, Intralipid suspension, perfluorocarbon emulsion and (129)Xe gas-filled liposomes. The T(1) of (129)Xe in these compounds ranged from 47 to 116 s. Vascular injection of these carrier agents was tolerated well, encouraging their use for further experiments in live animals. In vivo spectra, obtained from gas-filled liposomes and perfluorocarbon solutions, suggest that these carrier agents have potential for use in angiography and perfusion imaging. Copyright 2000 John Wiley & Sons, Ltd.

Non-NASA Center

Reduced xenon diffusion for quantitative lung study--the role of SF(6)

The large diffusion coefficients of gases result in significant spin motion during the application of gradient pulses that typically last a few milliseconds in most NMR experiments. In restricted environments, such as the lung, this rapid gas diffusion can lead to violations of the narrow pulse approximation, a basic assumption of the standard Stejskal-Tanner NMR method of diffusion measurement. We therefore investigated the effect of a common, biologically inert buffer gas, sulfur hexafluoride (SF(6)), on (129)Xe NMR and diffusion. We found that the contribution of SF(6) to (129)Xe T(1) relaxation in a 1:1 xenon/oxygen mixture is negligible up to 2 bar of SF(6) at standard temperature. We also measured the contribution of SF(6) gas to (129)Xe T(2) relaxation, and found it to scale inversely with pressure, with this contribution approximately equal to 1 s for 1 bar SF(6) pressure and standard temperature. Finally, we found the coefficient of (129)Xe diffusion through SF(6) to be approximately 4.6 x 10(-6) m(2)s(-1) for 1 bar pressure of SF(6) and standard temperature, which is only 1.2 times smaller than the (129)Xe self diffusion coefficient for 1 bar (129)Xe pressure and standard temperature. From these measurements we conclude that SF(6) will not sufficiently reduce (129)Xe diffusion to allow accurate surface-area/volume ratio measurements in human alveoli using time-dependent gas diffusion NMR.

Non-NASA Center