Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗

In-Situ XRD/XRF to Support Life Detection on Mars

X-ray diffraction / X-ray fluorescence (XRD/XRF) analysis provides the most comprehensive mineralogical / compositional characterization of rocks and soils of any flight-capable technique. XRD data provide quantitative mineralogy (including abundance of X-ray amorphous materials) and crystal chemistry (structure, elemental composition and valence state), and XRF data provide complimentary major, minor, and some trace element abundances. Both types of data are important in evaluating habitability (environment of formation) and biosignature preservation/degradation (post-depositional diagenetic change). Whether or not a relict biosignature is detected, the mineral assemblage and its geochemistry can be used to determine the habitability of an ancient environment (e.g., salinity, pH, temperature), and to identify potential sources of energy for life (e.g., elements in different redox states). In this respect, a null result (a habitable environment lacking evidence of life) can play an important role in constraining the parameters of the search. Conversely, diagenetic alteration (taphonomic change) resulting from post-depositional variations in temperature, pressure or fluid chemistry can preserve evidence of biogenicity, erase such evidence completely or indeed can provide for post-depositional habitable conditions in the subsurface. XRD / XRF data are critical to these determinations. The CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover is the first XRD instrument flown in space. CheMin operates in transmission geometry with a Co X-ray source to minimize fluorescence from iron. Diffracted photons are collected with an energy-sensitive charge-coupled device (CCD). The position of the diffracted photons provides structural information for minerals, whereas the energy of sample-generated X-ray fluorescence photons provides elemental information, though these XRF data are qualitative. Mineralogical data from the CheMin XRD identified the three circumstances above: habitable depositional environments (e.g., Yellowknife Bay), habitable subsurface/diagenetic environments (e.g., throughout the Murray formation), and diagenetic conditions that may destroy evidence of habitability (e.g., oxidative and acidic environments at Vera Rubin ridge). Technological advances in X-ray technology and lessons learned from the operation of CheMin on Mars have resulted in a next-generation XRD/XRF, called CheMinX. Replacement of CheMin’s CCD with an array of hybrid pixel detectors and improvements in focusing optics dramatically decrease analysis time (15 minutes vs. 22 hours for MSL-CheMin) and result in a better angular resolution (0.18 vs. 0.30 °2θ for MSL-CheMin). This increased resolution improves mineral detection, including discrimination between types of pyroxenes, which is not possible with MSL-CheMin data. The hybrid pixel detectors do not require cooling like the MSL-CheMin CCD, therefore reducing the power needed to operate CheMinX. CheMinX has a silicon-drift detector (SDD) to measure fluoresced photons, enabling the quantification of major, minor, and some trace elements via XRF. XRD/XRF data are collected simultaneously in CheMinX, obviating the need for multiple compositional instruments. The CheMinX design also improves upon MSL-CheMin’s sample handling. Instead of sample cells on wheel, which are often not reusable and add complexity in commanding the instrument, CheMinX has single-use cells in a cartridge/dispenser configuration. Because of these improvements, CheMinX is an ideal instrument for Discovery-class life-detection missions, including Mars Life Explorer that was recommended for development in the Planetary Science and Astrobiology Decadal Survey 2023-2032.

E B Rampe↗

Some aspects of analytical chemistry as applied to water quality assurance techniques for reclaimed water: The potential use of X-ray fluorescence spectrometry for automated on-line fast real-time simultaneous multi-component analysis of inorganic pollutants in reclaimed water

The potential use of isotopically excited energy dispersive X-ray fluorescence (XRF) spectrometry for automated on line fast real time (5 to 15 minutes) simultaneous multicomponent (up to 20) trace (1 to 10 parts per billion) analysis of inorganic pollutants in reclaimed water was examined. Three anionic elements (chromium 6, arsenic and selenium) were studied. The inherent lack of sensitivity of XRF spectrometry for these elements mandates use of a preconcentration technique and various methods were examined, including: several direct and indirect evaporation methods; ion exchange membranes; selective and nonselective precipitation; and complexation processes. It is shown tha XRF spectrometry itself is well suited for automated on line quality assurance, and can provide a nondestructive (and thus sample storage and repeat analysis capabilities) and particularly convenient analytical method. Further, the use of an isotopically excited energy dispersive unit (50 mCi Cd-109 source) coupled with a suitable preconcentration process can provide sufficient sensitivity to achieve the current mandated minimum levels of detection without the need for high power X-ray generating tubes.

Ling, A. C.↗

A Combined XRD/XRF Instrument for Lunar Resource Assessment

Robotic surface missions to the Moon should be capable of measuring mineral as well as chemical abundances in regolith samples. Although much is already known about the lunar regolith, our data are far from comprehensive. Most of the regolith samples returned to Earth for analysis had lost the upper surface, or it was intermixed with deeper regolith. This upper surface is the part of the regolith most recently exposed to the solar wind; as such it will be important to resource assessment. In addition, it may be far easier to mine and process the uppermost few centimeters of regolith over a broad area than to engage in deep excavation of a smaller area. The most direct means of analyzing the regolith surface will be by studies in situ. In addition, the analysis of the impact-origin regolith surfaces, the Fe-rich glasses of mare pyroclastic deposits, are of resource interest, but are inadequately known; none of the extensive surface-exposed pyroclastic deposits of the Moon have been systematically sampled, although we know something about such deposits from the Apollo 17 site. Because of the potential importance of pyroclastic deposits, methods to quantify glass as well as mineral abundances will be important to resource evaluation. Combined x ray diffraction (XRD) and x ray fluorescence (XRF) analysis will address many resource characterization problems on the Moon. XRF methods are valuable for obtaining full major-element abundances with high precision. Such data, collected in parallel with quantitative mineralogy, permit unambiguous determination of both mineral and chemical abundances where concentrations are high enough to be of resource grade. Collection of both XRD and XRF data from a single sample provides simultaneous chemical and mineralogic information. These data can be used to correlate quantitative chemistry and mineralogy as a set of simultaneous linear equations, the solution of which can lead to full characterization of the sample. The use of Rietveld methods for XRD data analysis can provide a powerful tool for quantitative mineralogy and for obtaining crystallographic data on complex minerals.

Vaniman, D. T.↗

Remote X-Ray Diffraction and X-Ray Fluorescence Analysis on Planetary Surfaces

The legacy of planetary X-ray Diffraction (XRD) and X-ray Fluorescence (XRF) began in 1960 when W. Parish proposed an XRD instrument for deployment on the moon. The instrument was built and flight qualified, but the Lunar XRD program was cancelled shortly before the first human landing in 1969. XRF chemical data have been collected in situ by surface landers on Mars (Viking 1 & 2, Pathfinder) and Venus (Venera 13 & 14). These highly successful experiments provide critical constraints on our current understanding of surface processes and planetary evolution. However, the mineralogy, which is more critical to planetary surface science than simple chemical analysis, will remain unknown or will at best be imprecisely constrained until X-ray diffraction (XRD) data are collected. Recent progress in X-ray detector technology allows the consideration of simultaneous XRD (mineralogic analysis) and high-precision XRF (elemental analysis) in systems miniaturized to the point where they can be mounted on fixed landers or small robotic rovers. There is a variety of potential targets for XRD/XRF equipped landers within the solar system, the most compelling of which are the poles of the moon, the southern highlands of Mars and Europa.

Blake, David F.↗

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗

Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

Instrument Development: The membrane properties were investigated in detail due to its critical role. A series of experiments determined that our designed membranes have high electron transmission, yet are capable of isolating high vacuum, are able to withstand differential pressure in excess of one atmosphere, survive vibrational shocks of a magnitude to be expected during a planetary mission. Our initial work has been with a 10 keV source and a 200 nm thick Silicon Nitride (SiN) encapsulation membrane micro-fabricated within a Si support frame (1.5 mm x 1.5 mm window openings. Fig 2 compares the spectra taken with the 10 keV source with spectra taken within SEM. Introduction: This paper describes the progress in the development of the AEXS instrument in our laboratory at JPL. The AEXS is a novel miniature instrument[1-3] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. The impinging electrons excite XRF spectra from the irradiated spots on samples in external atmosphere with high-to-medium (sub-mm to cm-scale) spatial resolution at Mars atmospheric pressure. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition, or in the case of electron-induced luminescence to identify unusual formations on surface that cathodo-luminescence (CL). The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an EDX detection and analyzer system to determine the elemental abundance, an optional CL detection system, and a high voltage power supply. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of micro-fabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. This paper will focus on description of the development of the instrument.

Wilcox, J. Z.↗

X-ray Fluorescence Spectroscopy Study of Coating Thickness and Base Metal Composition

For electrical, electronic, and electromechanical (EEE) parts to be approved for space use, they must be able to meet safety standards approved by NASA. A fast, reliable, and precise method is needed to make sure these standards are met. Many EEE parts are coated in gold (Au) and nickel (Ni), and the thickness coating is crucial to a part s performance. A nondestructive method that is efficient in measuring coating thickness is x-ray fluorescence (XRF) spectroscopy. The XRF spectrometer is a machine designed to measure layer thickness and composition of single or multilayered samples. By understanding the limitations in the collection of the data by this method, accurate composition and thickness measurements can be obtained for samples with Au and Ni coatings. To understand the limitations of data found, measurements were taken with the XRF spectrometer and compared to true values of standard reference materials (SRM) that were National Institute of Standards and Technology (NIST) traceable. For every sample, six different parameters were varied to understand measurement error: coating/substrate combination, number of layers, counting interval, collimator size, coating thickness, and test area location. Each measurement was taken in accordance with standards set by the American Society for Testing and Materials (ASTM) International Standard B 568.

Rolin, T. D.↗

The Mapping X-Ray Fluorescence Spectrometer (MAPX)

MapX will provide elemental imaging at ≤100 micron spatial resolution over 2.5 X 2.5 centimeter areas, yielding elemental chemistry at or below the scale length where many relict physical, chemical, and biological features can be imaged and interpreted in ancient rocks. MapX is a full-frame spectroscopic imager positioned on soil or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample surface with X-rays or αlpha-particles / gamma rays, resulting in sample X-ray Fluorescence (XRF). Fluoresced X-rays pass through an X-ray lens (X-ray μ-Pore Optic, "MPO") that projects a spatially resolved image of the X-rays onto a CCD. The CCD is operated in single photon counting mode so that the positions and energies of individual photons are retained. In a single analysis, several thousand frames are stored and processed. A MapX experiment provides elemental maps having a spatial resolution of ≤100 micron and quantitative XRF spectra from Regions of Interest (ROI) 2 centimers ≤ x ≤ 100 micron. ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. The MapX geometry is being refined with ray-tracing simulations and with synchrotron experiments at SLAC. Source requirements are being determined through Monte Carlo modeling and experiment using XMIMSIM [1], GEANT4 [2] and PyMca [3] and a dedicated XRF test fixture. A flow-down of requirements for both tube and radioisotope sources is being developed from these experiments. In addition to Mars lander and rover missions, MapX could be used for landed science on other airless bodies (Phobos/Deimos, Comet nucleus, asteroids, the Earth's moon, and the icy satellites of the outer planets, including Europa.

Blake, David↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC): A Payload Designed for Exploration of Terrestrial Planetary Bodies

Geological materials (indeed, all solid objects) are characterized by their crystal structure, elemental composition, and morphology. The Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC) instrument suite quantifies all three. These measurements address fundamental science questions (e.g., the origin and evolution of planetary bodies) and support the human exploration of space (e.g., the characterization of regolith for ISRU and the constraint of its geotechnical properties). METRIC comprises an X-ray Diffraction/X-ray Fluorescence instrument (XRD: mineral structure and XRF: elemental composition), an X-ray micro-Computed Tomography instrument (XCT: 3D internal micromorphology), and a hyperspectral imaging infrared spectrometer (IRS) to provide local/regional mineralogic context for these measurements. METRIC XRD/F draws heritage from the highly successful Mars Science Laboratory CheMin instrument. The METRIC XRD/F employs two separate sample cells, one optimized for XRD and one for XRF, resulting in more rapid XRD analysis (tens of minutes vs. tens of hours for CheMin) and an orders-of-magnitude improvement in XRF detection. XCT has not been deployed in space, so the METRIC XCT represents a new capability for solar system exploration. The XCT uses the same basic high-TRL components as METRIC XRD/F, decreasing its development cost for flight. The METRIC IRS is a derivative of the NASA Earth Science Technology Office funded Hyperspectral Thermal Imager instrument and utilizes the NASA Technology Transfer Program to incorporate a commercial-of-the-shelf infrared camera ruggedized for space by NASA Marshall Space Flight Center. The IRS spectral range (8–14 µm) and resolution (10.8 cm -1 ) are tailored to quantify mineralogy in rocks using their characteristic Reststrahlen bands and to characterize mineralogy of soils using the position of the Christensen Feature. The METRIC payload is currently designed for deployment to the Moon on a Commercial Lunar Payload Services (CLPS) mission, where the XRD/F and XCT would be located on a lander and the IRS would be on deployed on a companion rover to evaluate the mineralogical diversity of the landing site. A pneumatic drill designed by Honeybee Robotics would excavate regolith up to 50 cm below the lander and deliver multiple aliquots of regolith to the XRD/F and XCT. The METRIC payload could also be deployed on a rover. In this case, a sample handling system on a robotic arm could scoop regolith and/or drill rocks and deliver powder to the XRD/F and XCT located in the rover’s interior. Alternatively, METRIC instruments could be used singly or in combination on human space missions. The XRD/F and XCT could be used to characterize samples in a rover or in a science laboratory within a habitat. These data could help astronauts identify resource-enriched rocks and regolith and triage geologic samples to return samples of high interest for analysis in terrestrial laboratories. The IRS could be attached to a human-navigated rover to collect mineralogical data along a traverse and identify high-priority science samples.

E. B. Rampe↗

MapX: An In Situ, Full-Frame X-Ray Spectroscopic Imager for the Biogenic Elements

Microbial life exploits microscale disequilibria at boundaries where valence, chemical potential, pH, Eh, etc. vary on a length scale commensurate with the organisms themselves - tens to hundreds of micrometers. These disequilibria can exist within cracks or veins in rocks and ice, at inter- or intra-crystalline boundaries, at sediment/water or sediment/atmosphere interfaces, or even within fluid inclusions trapped inside minerals. The detection of accumulations of the biogenic elements C,N,O,P,S at appropriate concentrations on or in a mineral/ice substrate would constitute permissive evidence of extant life, but context is also required. Does the putative biosignature exist in a habitable environment? Under what conditions of P, T, and chemical potential was the host mineralogy formed? MapX is an arm-deployed contact instrument that directly images the biogenic elements C, N, O, P, S, as well as the cations of the rock-forming minerals (Na, Mg, Al, Si, K, Ca, Ti, Cr, Mn, Fe) and important anions such as Cl, Fl. The instrument provides element images having ≤100 micron lateral spatial resolution over a 2.5 cm X 2.5 cm area, as well as quantitative XRF spectra from ground-selected or instrument-selected Regions of Interest (ROI) on the sample. Quantitative XRF spectra from ROI can be translated into mineralogies using ground- or instrument-based algorithms. Either an X-ray tube source (X-ray fluorescence) or a radioisotope source such as 244-Cm (alpha-particle and gamma-ray fluorescence) can be used, and characteristic X-rays emitted from the sample are imaged onto an X-ray sensitive CCD through an X-ray MicroPore Optic (MPO). As a fluorescent source, 244-Cm is highly desirable in a MapX instrument intended for life detection since high-energy alpha-particles are unrivaled in fluorescence yield for the low-Z elements. The MapX design as well as baseline performance requirements for a MapX instrument intended for life detection/identification of habitable environments will be presented.

micro-XRF spectrometer↗

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

Utilization of independent solar flux measurements to eliminate nongeochemical variation in X-ray fluorescence data

It is shown that the direct method of solar activity correction for lunar XRF data produces XRF data with better statistics than uncorrected data. Direct measurements of the solar flux made by Solrad 10 are converted to emissions of the sun from two assumed temperature regions. These emissions are ratioed to produce emission measure ratios, sensitive indicators of shifts in solar activity. The Tucker-Koren model (1971) of the solar flux is used in the calculation of EMRs and in the calculation of theoretical lunar Si, Al, and Mg fluorescence of maria and highland soils. Al/Si(Mg/Si) ratios calculated at a 'normal' EMR of 0.030 are divided by Al/Si(Mg/Si) ratios at particular EMRs. The relationship between EMR and the quotients of this division, called 'correction factors', is well explained by empirically derived power law functions.

Clark, P. E.↗

Compositional variation in the Hadley Apennine region

Orbital geochemical data in the Hadley Apennine region are related to typical rock compositions and used in determining the distribution of soils derived from the rock types found in this region. Orbital XRF Mg/Si and Al/Si intensities are the orbital data that are used primarily. These data are corrected for spurious interorbit variation using a modification of a previously developed method. The corrected values are than converted to % MgO and % Al2O3, respectively, from theoretical considerations, and as such are compared with similar concentrations for typical lunar rocks and soils of the Apollo 15 landing site. The relationship of the XRF values to Fe, Ti, and Th concentrations, derived from gamma-ray observations, is also considered. It is established that the orbital geochemistry data for this region are consistent with the presence of a mixture of ANT suite and Fra Mauro basalt components frequently dominated by a KREEP basalt component toward the west and by a mafic pyroclastic component toward the east.

Clark, P. E.↗

Crustal development in the terrestrial planets

The development of planetary crusts may be divided into primary, resulting from melting during accretion, and secondary crusts developed by partial melting from planetary mantles. The Mercurian crust is probably primary with no compelling evidence of later basaltic extrusions. Reflectance spectral evidence for the existence Fe2(+) is equivocal. The Viking Lander XRF data on Mars indicate basaltic material at both sites 4,000 km apart. Surface aeolian processes would be expected to provide a homogeneous average of the crust, but no evidence of more siliceous material is present. This conclusion is weakly supported by the Russian gamma ray data. No evidence for granite appears from the Russian Venera XRF data which indicates MORB-type and alkali basalt (4% K2O) surface compositions. The highlands of Ishtar Terra and Aphrodite probably owe their elevation to tectonic processes rather than compositional effects. Venus may thus resemble the early Archean Earth. The terrestrial granitic continental crust is a product of episodic multiple partial melting events, probably a consequence of the presence of surface water.

Taylor, S. R.↗

Fine-scale traverses in cumulate rocks, Stillwater Complex: A lunar analogue study

The objective was to document finite-scale compositional variations in cumulate rocks from the Stillwater Complex in Montana and to interpret these data in the context of planetary magma fractionation processes such as those operative during the formation of the Earth's Moon. This research problem involved collecting samples in the Stillwater Complex and analyzing them by electron microprobe, X-ray fluorescence (XRF), and instrumental neutron activation analysis (INAA). The electron microprobe is used to determine the compositions of cumulus and intercumulus phases in the rocks, the XRF is used to determine the bulk-rock major element and trace element (Y, Sr, Rb, Zr, Ni, and Cr) abundances, and the INAA lab. is used to determine the trace element (Sc, Co, Cr, Ni, Ta, Hf, U, Th, and the REE) abundances of mineral separates and bulk rocks.

Elthon, Donald↗

X-ray fluorescence analysis of alloy and stainless steels using a mercuric iodide detector

A mercuric iodide detector was used for the XRF analysis of a number of NBS standard steels, applying a specially developed correction method for interelemental effects. It is shown that, using this method and a good peak-deconvolution technique, the HgI2 detector is capable of achieving resolutions and count rates needed in the XRF anlysis of multielement samples. The freedom from cryogenic cooling and from power supplies necessary for an electrically cooled device makes this detector a very good candidate for a portable instrument.

Kelliher, Warren C.↗

The relationship between orbital, earth-based, and sample data for lunar landing sites

Results are reported of a detailed examination of data available for the Apollo lunar landing sites, including the Apollo orbital measurements of six major elements derived from XRF and gamma-ray instruments and geochemical parameters derived from earth-based spectral reflectivity data. Wherever orbital coverage for Apollo landing sites exist, the remote data were correlated with geochemical data derived from the soil sample averages for major geological units and the major rock components associated with these units. Discrepancies were observed between the remote and the soil-anlysis elemental concentration data, which were apparently due to the differences in the extent of exposure of geological units, and, hence, major rock eomponents, in the area sampled. Differences were observed in signal depths between various orbital experiments, which may provide a mechanism for explaining differences between the XRF and other landing-site data.

Clark, P. E.↗