Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Recent progress on coarse graining simulations

We focus on coarse graining simulations based on the primary conservation equations, effectively codesigned physics and algorithms, and low-Mach-number corrected (LMC) hydrodynamics. Simulation methods involve LANL’s x-Radiation-Adaptive-Grid-Eulerian Large-Eddy Simulation, Besnard-Harlow-Rauenzahn (BHR) Reynolds-Averaged Navier-Stokes (RANS) approach, and Dynamic BHR – a paradigm bridging RANS and LES. A relevant question addressed relates to whether 3D RANS and RANS/LES hybrids – the industry standards for aerospace and automotive research, are presently relevant for practical variable-density applications involving shocked and accelerated interface instabilities. Furthermore, recent simulations of the GaTECH inclined mixing-layer shock-tube and NIF ICF-capsule experiments are used to demonstrate issues, challenges, and potential for 3D coarse grained LMC simulation strategies for robustly simulating complex transitional and coupled hydrodynamics-multiphysics with coarser resolution. Present LES readiness to provide accurate predictions at scale is demonstrated – whereas 3D RANS and RANS/LES bridging do not appear impactful in this context.

42 ENGINEERING↗

Beryllium (Be) Handbook

Beryllium (Be), atomic number 4, is a silver gray metal of low density (1.85g/cm 3 ), moderately high melting point (1289°C), and quite good stability in the atmosphere. Favorable mechanical properties, particularly specific stiffness (elastic modulus/density), have resulted in a number of weight-critical structural applications. Other notable properties of beryllium include good dimensional stability, high specific heat and extremely high transparency to X-radiation. The nuclear properties of beryllium include a high neutron scattering cross section (6 barns for thermal neutrons) and a low neutron absorption cross section (0.009 barns for thermal neutrons) making it a good choice for a neutron reflector. The (n, 2n) reaction in beryllium also makes it suitable for a neutron multiplier.

36 MATERIALS SCIENCE↗

Evaluation of quantitative synchrotron radiation micro-X-ray fluorescence in rice grain

Concentrations of nutrients and contaminants in rice grain affect human health, specifically through the localization and chemical form of elements. Methods to spatially quantify the concentration and speciation of elements are needed to protect human health and characterize elemental homeostasis in plants. Here, an evaluation was carried out using quantitative synchrotron radiation microprobe X-ray fluorescence (SR-µXRF) imaging by comparing average rice grain concentrations of As, Cu, K, Mn, P, S and Zn measured with rice grain concentrations from acid digestion and ICP-MS analysis for 50 grain samples. Better agreement was found between the two methods for high-Z elements. Regression fits between the two methods allowed quantitative concentration maps of the measured elements. These maps revealed that most elements were concentrated in the bran, although S and Zn permeated into the endosperm. Arsenic was highest in the ovular vascular trace (OVT), with concentrations approaching 100 mg kg –1 in the OVT of a grain from a rice plant grown in As-contaminated soil. Quantitative SR-µXRF is a useful approach for comparison across multiple studies but requires careful consideration of sample preparation and beamline characteristics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On Possibilities of Using Edge Radiation for X-ray and Electron Beam Diagnostics at Bending Magnet Beamlines of NSLS-II

Spectral flux density distributions of long-wavelength Edge Radiation, i.e. radiation generated by relativistic electrons at edges of bending magnets in a storage ring are described, both analytically and numerically. Possibilities of using this radiation for the alignment of optical components of bending magnet beamlines at NSLS-II and for non-destructive X-ray and electron beam diagnostics at these beamlines are discussed.

43 PARTICLE ACCELERATORS↗

Calibration of the IXPE Focal Plane X-Ray Polarimeters to Polarized Radiation

The Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission—in partnership with the Italian Space Agency—dedicated to X-ray polarimetry in the 2–8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector, a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units at INAF-IAPS, in Italy, where a dedicated facility was setup at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

79 ASTRONOMY AND ASTROPHYSICS↗

The infrared imaging video bolometer at Wendelstein 7-X

The radiated power distribution is a crucial aspect of heat transport, heat load mitigation, and plasma exhaust performance. An imaging video bolometer camera has been installed to measure the plasma radiated power in the divertor region of the Wendelstein 7-X (W7-X) stellarator. This diagnostic offers a wide-angle (40° × 68°) sampling of the plasma volume in both the poloidal and toroidal directions. The field-of-view is covered with a large number (> 500) of bolometer channels, providing imaging capability. The diagnostic design is introduced here together with its data analysis procedure. A set of laboratory experiments is performed to assess the thermal properties of the gold absorber foil and their spatial uniformity. Following installation, a heat source originating from the inertially cooled front of the diagnostic is identified and filtered out. The discharge data indicate a satisfactory signal-to-noise ratio as well as spatiotemporal resolution. These represent the first toroidally resolved images of the line-integrated radiated power in the W7-X island divertor. The diagnostic was then upgraded with a thinner platinum absorber and adjusted mirrors. Early data from the most recent experimental campaign employing the upgraded design show a considerable improvement in the diagnostic performance with more bolometer channels (> 1400), extended coverage, and increased spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative study of crystallization kinetics and phase segregation of triple cation and methylammonium lead iodide perovskites on moisture probing using synchrotron X-ray based radiation

3D mixed perovskites have achieved substantial success in boosting solar cell efficiency, but the complicated perovskite crystal formation pathway remains mysterious. Here we present detailed crystallization kinetics of mixed perovskites FA 0.83 MA 0.17 Pb(I 0.83 Br 0.17 ) 3 , where FA is formamidinium and MA is methylammonium, with the addition of Cs + to form a triple cation perovskite (3-CAT), in a comparison with the perovskite building block MAPbI 3 (MAPI) via static grazing-incidence wide-angle X-ray scattering (GIWAXS) and micro-diffraction measurements. Spin-coated films produced α-perovskite peaks with no PbI 2 or δ-intermediate phases, which was a promising result for the 3-CAT perovskite from micro-diffraction measurements. However, the 3-CAT did not remain stable on probing with varied relative humidity (RH) conditions as segregation back to the δ-intermediate and PbI 2 phase after 10 s of exposure to an RH value of 11% was found to occur from the GIWAXS results. When RH levels were elevated to over 100%, segregation peaks of PbI 2 and δ-intermediate (2H, 4H and 6H) became conspicuous as the α-phase intensity diminished, unlike for MAPI that remains relatively stable. The possible cause of this is hydrophilic bonds that form between the 3-CAT crystals and the small annealing window of the best composition perovskite (5% Cs + ) film.

Shatsala, Miller (ORCID:0009000927230192)↗

Evaluation of the relative importance of preheat from hohlraum x rays and a radiative shock on a low-density foam

Indirectly driven shock-tube experiments were performed on the Omega Laser Facility to evaluate the relative importance of hohlraum x ray and radiative shock preheat sources on a low-density foam. X rays emitted from the hohlraum and a subsequent shock wave are channeled into a low-density foam sample, which contains a plastic preheat-witness disk placed downstream of the foam. Simultaneous radiographic measurements of the shock speed in the foam and the expansion rate of the witness disk due to preheat allow for the observation of effects from the hohlraum's low-energy and high-energy x-ray spectrum. Here we showed, from simulations, that low-energy x rays from the hohlraum are preferentially absorbed near the ablator surface (where the hohlraum and the shock tube meet), while higher-energy x rays largely pass through the ablator and foam and are volumetrically absorbed by the witness disk. Reproducing the experimentally measured shock speed and expansion of the witness disk simultaneously, we extracted the temperature evolution of preheated foam from the simulation and evaluated the relative importance of preheat sources on a low-density foam from hohlraum x-ray radiation and radiative shock. We found that radiation from the shock front was more effective at preheating the low-density foam than the high-energy x rays from the hohlraum. This shock-tube preheat experiment is important for understanding the results of the MARBLE experiments at the National Ignition Facility because initial conditions of foam-filled MARBLE capsules are sensitive to preheat.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermo-Mechanical Shock, X-Ray Transport and Radiation Response Analysis Experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton Radiotherapy to Preserve Fertility and Endocrine Function: A Translational Investigation

Photon radiation therapy (x-ray radiation therapy [XRT] and gamma-ray radiation therapy [GRT]) of tumors close to ovaries causes reproductive and endocrine sequelae due to ovarian primordial follicle depletion. Given its finite range, proton radiation therapy (PRT) can preserve ovarian function when ovaries are positioned distal to the spread-out Bragg peak (SOBP) in tumors of the abdominopelvic region. This study compared anti-Müllerian hormone (AMH) levels (a biomarker of ovarian function) and primordial follicle survival after in vivo mouse pelvic GRT versus PRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of self-magnetic pinch radiographic diode performance on RITS-6 at Sandia National Laboratories. II. Coupling between the inductive voltage adder and the SMP load

The self-magnetic pinch (SMP) diode is a type of radiographic diode used to generate an intense electron beam for radiographic applications. At Sandia National Laboratories, SMP was the diode load for the six-cavity radiographic integrated test stand inductive voltage adder (IVA) driver operated in a magnetically insulated transmission line (MITL). The MITL contributes a flow current in addition to the current generated within the diode itself. Extensive experiments with a MITL of 40Ω load impedance [T. J. Renk et al., Phys. Plasmas 29, 023105 (2022)] indicate that the additional flow current leads to results similar to what might be expected from a conventional high-voltage interface driver, where flow current is not present. However, when the MITL flow impedance was increased to 80 Ω, qualitatively different diode behavior was observed. This includes large retrapping waves suggestive of an initial coupling to low impedance as well as diode current decreasing with time even as the total current does not. A key observation is that the driver generates total current (flow + diode) consistent with the flow impedance of the MITL used. The case is made in this paper that the 80Ω MITL experiments detailed here can only be understood when the IVA-MITL-SMP diode is considered as a total system. Additionally, the constraint of fixed total current plus the relatively high flow impedance limits the ability of the diode (whether SMP or other type) to act as an independent load. An unexpected new result is that in tracking the behavior of the electron strike angle on the converter as a function of time, we observed that the conventional cIV x “Radiographic” radiation scaling (where x~2.2) begins to break down for voltages above 8 MV, and cubic scaling is required to recover accurate angle tracking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

High-dynamic-range transmission-mode detection of synchrotron radiation using X-ray excited optical luminescence in diamond

Enhancement of X-ray excited optical luminescence in a 100 µm-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing is demonstrated. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range 7.6 × 10 8 to 1.26 × 10 12 photons s -1 mm -2 for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.

Instruments & Instrumentation↗