Progress on a Superconducting Planar Undulator in the UK

Superconducting (SC) undulators can potentially reach a higher field, for short period devices, than permanent magnet devices. The latest design work on a proposed superconducting planar undulator being designed in the UK by the STFC is presented. The initial layout of the undulator, including superconducting fill factor and the cryogenic system is presented. Calculations of the wakefield heating effects due to different vacuum vessels and electron beam configurations are also presented. Another important issue for superconducting planar undulators is the effect of engineering tolerances of the pole pieces: the computer simulated effects, for different size pole errors, on the electron beam trajectory and phase error through the device are also shown.

43 PARTICLE ACCELERATORS↗

Overview of the superconducting undulator development program at ANKA

Superconducting undulators (SCUs) have the potential to reach higher brilliance and flux with respect to the state of the art permanent magnet insertion devices. ANKA is collaborating with the industrial partner Babcock Noell GmbH (BNG) to realize NbTi conduction cooled planar devices for low emittance light sources, and is developing the instrumentation to characterize the magnetic field properties and to measure the beam heat load to a cold bore needed for the cryogenic design of SCUs. We present here: the most recent results obtained within the ANKA-BNG collaboration, the progress achieved in the development of the instrumentation, and the in house studies on the application of high temperature superconducting (HTS) tape to the SCU technology.

43 PARTICLE ACCELERATORS↗

Efficiency and Spectrum Enhancement in a Tapered Free-Electron Laser Amplifier

We report the first experimental characterization of efficiency and spectrum enhancement in a laser-seeded free-electron laser using a tapered undulator. Output and spectra in the fundamental and third harmonic were measured versus distance for uniform and tapered undulators. With a 4% field taper over 3 m, a 300% (50%) increase in the fundamental (third harmonic) output was observed. A significant improvement in the spectra with the elimination of sidebands was observed using a tapered undulator. The experiment is in good agreement with predictions using the MEDUSA simulation code.

43 PARTICLE ACCELERATORS↗

A design concept for a planar superconducting undulator for the APS.

A superconducting planar undulator is under development at the Advanced Photon Source. The R&D phase culminated in the successful testing of several short magnetic structure prototypes. Work is now focused on a complete design for the first undulator. The conceptual designs for its superconducting magnet, the cooling system, and the cryostat are described in this paper.

43 PARTICLE ACCELERATORS↗

Cyclotron Resonances in Electron Cloud Dynamics

A new set of resonances for electron cloud dynamics in the presence of a magnetic field has been found. For short beam bunch lengths and low magnetic fields where l{sub b} << 2{pi}{omega}{sub c}, (l{sub b} = bunch duration, {omega}{sub c} = non-relativistic cyclotron frequency) resonances between the bunch frequency and harmonics of the cyclotron frequency cause an increase in the electron cloud density in narrow ranges of magnetic field near the resonances. For ILC parameters the increase in the density is up to a factor {approx} 3, and the spatial distribution of the electrons is broader near resonances, lacking the well-defined density 'stripes' of multipactoring found for non-resonant cases. Simulations with the 2D computer code POSINST, as well as a single-particle tracking code, were used to elucidate the physics of the dynamics. The resonances are expected to affect the electron cloud dynamics in the fringe fields of conventional lattice magnets and in wigglers, where the magnetic fields are low. Results of the simulations, the reason for the bunch-length dependence, and details of the dynamics will be discussed.

43 PARTICLE ACCELERATORS↗

Cyclotron Resonances in Electron Cloud Dynamics

A new set of resonances for electron cloud dynamics in the presence of a magnetic field has been found. For short beam bunch lengths and low magnetic fields where lb<< 2pi c/omega c (with lb = bunch length, omega c = non-relativistic cyclotron frequency) resonances between the bunch frequency and harmonics of the electron cyclotron frequency cause an increase in the electron cloud density in narrow ranges of magnetic field near the resonances. For ILC parameters the increase in the density is up to a factor ~;;3, and the spatial distribution of the electrons is broader near resonances, lacking the well-defined vertical density"stripes" found for non-resonant cases. Simulations with the 2D computer code POSINST, as well as a single-particle tracking code, were used to elucidate the physics of the dynamics. The existence of the resonances has been confirmed in experiments at PEP-II. The resonances are expected to affect the electron cloud dynamics in the fringe fields of conventional lattice magnets and in wigglers, where the magnetic fields are low. Results of the simulations and experimental observations, the reason for the bunch-length dependence, and details of the dynamics are discussed here.

43 PARTICLE ACCELERATORS↗

Mode growth and competition in the x-ray free-electron laser oscillator start-up from noise.

We describe the radiation properties of an x-ray free-electron laser (FEL) oscillator, beginning with its start-up from noise through saturation. We first decompose the initially chaotic undulator radiation into the growing longitudinal modes of the composite system consisting of the electron beam, the undulator, and the Bragg mirror resonator cavity. Because the radiation initially comprises several modes whose growth rates are comparable, we find that only after many oscillator passes is the output pulse dominantly characterized by the lowest-order Gaussian mode. We verify our analytic results with a novel, reduced one-dimensional FEL code (derived in the text), and with two-dimensional FEL simulations. Understanding the full longitudinal structure during the initial amplification will be critical in assessing the tolerances on the electron beam, undulator, and optical cavity required for robust operation.

43 PARTICLE ACCELERATORS↗

Low-Charge, Hard X-Ray Free Electron Laser Driven with an X-Band Injector and Accelerator

After the successful operation of the Free Electron Laser in Hamburg (FLASH) and the Linac Coherent Light Source (LCLS), soft and hard x-ray free electron lasers (FELs) are being built, designed, or proposed at many accelerator laboratories. Acceleration employing lower frequency rf cavities, ranging from L-band to C-band, is usually adopted in these designs. In the first stage bunch compression, higher-frequency harmonic rf system is employed to linearize the beam's longitudinal phase space, which is nonlinearly chirped during the lower frequency rf acceleration process. In this paper, a hard x-ray FEL design using an all X-band accelerator at 11.424 GHz (from photocathode rf gun to linac end) is presented, without the assistance of any harmonic rf linearization. It achieves LCLS-like performance at low charge using X-band linac drivers, which is more versatile, efficient, and compact than ones using S-band or C-band rf technology. It employs initially 42 microns long (rms), low-charge (10 pC) electron bunches from an X-band photoinjector. An overall bunch compression ratio of roughly 100 times is proposed in a two stage bunch compressor system. The start-to-end macroparticle 3D simulation employing several computer codes is presented in this paper, where space charge, wakefields, and incoherent and coherent synchrotron radiation effects are included. Employing an undulator with a short period of 1.5 cm, a Genesis FEL simulation shows successful lasing at a wavelength of 0.15 nm with a pulse length of 2 fs and a power saturation length as short as 20 meters, which is equivalent to LCLS low-charge mode. Its overall length of both accelerators and undulators is 180 meters (much shorter than the effective LCLS overall length of 1230 meters, including an accelerator length of 1100 meters and an undulator length of 130 meters), which makes it possible to be built in places where only limited space is available.

43 PARTICLE ACCELERATORS↗

Electromagnetic Mass--Separation and Its Applications

The article describes the electromagnetic mass-separation method and its application in nuclear and solid state physics. The limited review of the results in these fields, obtained by scientific groups at the Physics Institute, Maria Curie Sklodowska University, Lublin, Poland and the Joint Institute for Nuclear Research, Dubna, Russia is presented.

43 PARTICLE ACCELERATORS↗

High-Gradient High-Energy-Gain Inverse Free Electron Laser Experiment Using a Helical Undulator

In this paper we present the design of the high-gradient, high-energy-gain IFEL accelerator proposed for construction at the ATF beamline in BNL. We plan to accelerate the ATF electron beam from 50 MeV to 120 MeV using a 60 cm long tapered permanent magnet helical undulator designed at UCLA and the existing ATF 0.5 TW CO2 laser system. The experiment will obtain a record 120 MV/m gradient and >70 MeV energy gain and will be an important step in the development of compact IFEL accelerators for the mid-high energy range (up to 1-2 GeV).

43 PARTICLE ACCELERATORS↗

CHESS upgrade with compact undulator magnets: Operating experience and first results

In November 2014 two in-air 1.5 m CHESS Compact Undulator (CCU) magnets built by KYMA S.R.l. were installed in Cornell Electron Storage Ring (CESR) in canted arrangement and after few days of commissioning their regular operation started. CCU magnets are compact, lightweight and cost efficient devices. They have very stable magnetic field integrals independent of deflection parameter value. This feature greatly simplifies the storage ring operation. The CCU concept was developed at Cornell in 2011 and the first 1 m in-vacuum CCU magnet was beam-tested in 2012. The article presents CCU concept and some details of the design. It describes also the layout of CCUs installation in CESR, their performance and characteristics. The current status of operation and future plans are discussed as well. Presently, at CHESS two CCU magnets provide radiation for 5 out of 11 experimental stations.

43 PARTICLE ACCELERATORS↗

Dual fast-cycling superconducting synchrotron at Fermilab and a possible path to the future of high energy particle physics

We briefly outline shorter and longer term physics motivation for constructing a dual, fast-cycling superconducting synchrotron accelerator (DSFMR - Dual Super-Ferric Main Ring) in the Tevatron tunnel at Fermilab. We discuss using this accelerator as a high-intensity dual neutrino beam source for the long-baseline neutrino oscillation search experiments, and also as a fast, dual pre-injector accelerator for the VLHC (Very Large Hadron Collider).

43 PARTICLE ACCELERATORS↗

Thermal Tests of Undulator Quad

Running at the nominal temperature, the undulator quadrupole has a several degree temperature increase. This note describes the test used to determine the effect on the undulator integrals from the temperature gradient caused by the heat from the quadrupole conducting down the beam pipe. The undulator quadrupoles running at their nominal current of 4 amps heat up approximately 4 degrees Celsius; this magnet in turn heats up the beampipe which goes into the undulator. The heating ends up introducing a thermal gradient across the undulator which causes small changes in the magnetic field of the heated poles. By measuring the temperature change in the poles we can model the effects on the field and determine what the magnetic errors will be.

43 PARTICLE ACCELERATORS↗

Magnetic Measurement of the Background Field in the Undulator Hall

The steel present in the construction of the undulator hall facility has the potential for changing the ambient fields present in the undulator hall. This note describes a measurement done to make a comparison between the fields in the hall and in the Magnetic Measurement Facility. In order for the undulators to have the proper tuning, the background magnetic field in the Undulator Hall should agree with the background field in the Magnetic Measurements Facility within .5 gauss. In order to verify that this was the case measurements were taken along the length of the undulator hall, and the point measurements were compared to the mean field which was measured on the MMF test bench.

36 MATERIALS SCIENCE↗

Undulator Long Coil Measurement System Tests

The first and second field integrals in the LCLS undulators must be below a specified limit. To accurately measure the field integrals, a long coil system is used. This note describes a set of tests which were used to check the performance of the long coil system. A long coil system was constructed to measure the first and second field integrals of the LCLS undulators. The long coil measurements of the background fields were compared to field integrals obtained by sampling the background fields and numerically calculating the integrals. This test showed that the long coil has the sensitivity required to measure at the levels specified for the field integrals. Tests were also performed by making long coil measurements of short magnets of known strength placed at various positions The long coil measurements agreed with the known field integrals obtained by independent measurements and calculation. Our tests showed that the long coil measurements are a valid way to determine whether the LCLS undulator field integrals are below the specified limits.

43 PARTICLE ACCELERATORS↗

Refurbishment of radiation-damaged undulators

Partial radiation damage has been observed over the previous five years of operation for a few of the PETRA III permanent magnet undulators at DESY. The degradation of the affected devices has been observed by a change in the energy tuning curves and the spectral properties of the undulator harmonics, and also by direct measurements of the peak field distribution of the magnet structure in the storage ring tunnel [1]. During the recent shutdown of the machine, two undulators were removed from the tunnel for repair. One of the devices (U29) has been retuned after flipping of all magnets of the hybrid structure. In addition to this temporary repair, one further magnet structure (U23) has been completely disassembled and refurbished by application of a rare earth diffusion process and a coating to the permanent magnets. We will report on the details of the refurbishment of these undulators which were both fully brought back to specifications and are meanwhile back in operation.

43 PARTICLE ACCELERATORS↗

Earth's Magnetic Field Measurements for the LCLS Undulators

Measurements of the earth's magnetic field at several locations at SLAC were conducted to determine the possible field error contribution from tuning the undulators in a location with a different magnetic field than that which will be found in the undulator hall. An average difference of 0.08 {+-} 0.04 Gauss has been measured between the downward earth's field components in the test facility and SLAC tunnel locations.