Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WEAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

NASA interdisciplinary collaboration in tribology. A review of oxidational wear

An in-depth review of oxidational wear of metals is presented. Special emphasis is given to a description of the concept of oxidational wear and the formulation of an Oxidational Wear Theory. The parallelism between the formation of an oxide film for dry contact conditions and the formation of other surface films for a lubricated contact is discussed. The description of oxidational wear is prefaced with a unification of wear modes into two major classes of mild and severe wear including both lubricated and dry contacts. Oxidational wear of metals is a class of mild wear where protective oxide films are formed at real areas of contact and during the time of contact at temperataure T sub c. When the oxide reaches a critical thickness, frequently in the range of 1 to 3 microns, the oxide breaks up and eventually appears as a wear particle. These oxides are preferentially formed on plateaux which alternately carry the load as they reach their critical thickness and are removed. If the system is operated at elevated temperatures, thick oxides can form both out of contact and between the plateaux. Temperature is important in determining the structure of the oxide film present. Spinel oxide (Fe3O4) which forms above 300 C is more protective than the lower temperature rhomobohedral (alpha-Fe2O3) oxide which is abrasive. An Oxidational Wear Theory is derived using a modified Archard wear law expressed in terms of activation energy (Qp) and Arrhenius constant (Ap).

Quinn, T. F. J.↗

Surface Design and Engineering Toward Wear-Resistant, Self-Lubricating Diamond Films and Coatings

The tribological properties of chemical-vapor-deposited (CVD) diamond films vary with the environment, possessing a Jekyll-and-Hyde character. CVD diamond has low coefficient of friction and high wear resistance in air but high coefficient of friction and low wear resistance in vacuum. Improving the tribological functionality of materials (such as achieving low friction and good wear resistance) was an aim of this investigation. Three studies on the surface design, surface engineering, and tribology of CVD diamond have shown that its friction and wear are significantly reduced in ultrahigh vacuum. The main criteria for judging whether diamond films are an effective wear-resistant, self-lubricating material were coefficient of friction and wear rate, which must be less than 0.1 and on the order of 10(exp 6) cu mm/N(dot)m, respectively. In the first study the presence of a thin film (less than 1 micron thick) of amorphous, nondiamond carbon (hydrogenated carbon, also called diamondlike carbon or DLC) on CVD diamond greatly decreased the coefficient of friction and the wear rate. Therefore, a thin DLC film on CVD diamond can be an effective wear-resistant, lubricating coating in ultrahigh vacuum. In the second study the presence of an amorphous, nondiamond carbon surface layer formed on CVD diamond by ion implantation significantly reduced the coefficient of friction and the wear rate in ultrahigh vacuum. Therefore, such surface layers are acceptable for effective self-lubricating, wear-resistant applications of CVD diamond. In the third study CVD diamond in contact with cubic boron nitride exhibited low coefficient of friction in ultra high vacuum. Therefore, this materials combination can provide an effective self-lubricating, wear-resistant couple in ultrahigh vacuum.

Miyoshi, Kazuhisa↗

Wear of Steel and Ti6Al4V Rollers in Vacuum

This investigation was prompted by results of a qualification test of a mechanism to be used for the James Webb Space Telescope. Post-test inspections of the qualification test article revealed some loose wear debris and wear of the steel rollers and the mating Ti6Al4V surfaces. An engineering assessment of the design and observations from the tested qualification unit suggested that roller misalignment was a controlling factor. The wear phenomena were investigated using dedicated laboratory experiments. Tests were done using a vacuum roller rig for a range of roller misalignment angles. The wear in these tests was mainly adhesive wear. The measured wear rates were highly correlated to the misalignment angle. For all tests with some roller misalignment, the steel rollers lost mass while the titanium rollers gained mass indicating strong adhesion of the steel with the titanium alloy. Inspection of the rollers revealed that the adhesive wear was a two-way process as titanium alloy was found on the steel rollers and vice versa. The qualification test unit made use of 440F steel rollers in the annealed condition. Both annealed 440F steel rollers and hardened 440C rollers were tested in the vacuum roller rig to investigate possibility to reduce wear rates and the risk of loose debris formation. The 440F and 440C rollers had differing wear behaviors with significantly lesser wear rates for the 440C. For the test condition of zero roller misalignment, the adhesive wear rates were very low, but still some loose debris was formed

Krantz, Timothy L.↗

WearGP: A computationally efficient machine learning framework for local erosive wear predictions via nodal Gaussian processes

Computational fluid dynamics (CFD)-based wear predictions are computationally expensive to evaluate, even with a high-performance computing infrastructure. Thus, it is difficult to provide accurate local wear predictions in a timely manner. Data-driven approaches provide a more computationally efficient way to approximate the CFD wear predictions without running the actual CFD wear models. In this paper, a machine learning (ML) approach, termed WearGP, is presented to approximate the 3D local wear predictions, using numerical wear predictions from steady-state CFD simulations as training and testing datasets. The proposed framework is built on Gaussian process (GP) and utilized to predict wear in a much shorter time. The WearGP framework can be segmented into three stages. At the first stage, the training dataset is built by using a number of CFD simulations in the order of O (10 2 ). At the second stage, the data cleansing and data mining process are performed, where the nodal wear solutions are extracted from the solution database to build a training dataset. At the third stage, the wear predictions are made, using trained GP processes. Two CFD case studies including 3D slurry pump impeller and casing are used to demonstrate the WearGP framework, in which 144 training and 40 testing data points are used to train and test the proposed method, respectively. The numerical accuracy, computational effiency and effectiveness between the WearGP framework and CFD wear model for both slurry pump impellers and casings are compared. It is shown that the WearGP framework can achieve highly accurate results that are comparable with the CFD results, with a relatively small size training dataset, with a computational time reduction in an order of 10 5 to 10 6 .

42 ENGINEERING↗

Friction and Wear Properties of As-deposited and Carbon Ion-implanted Diamond Films

Recent work on the friction and wear properties of as-deposited and carbon ion-implanted diamond films was reviewed. Diamond films were produced by the microwave plasma chemical vapor deposition (CVD) technique. Diamond films with various grain sizes and surface roughnesses were implanted with carbon ions at 60 ke V ion energy, resulting in a dose of 1.2310(exp 17) carbon ions/cm(exp 2). Various analytical techniques, including Raman spectroscopy, proton recoil analysis, Rutherford backscattering, transmission and scanning electron microscopy, x-ray photoelectron spectroscopy, and x-ray diffraction, were utilized to characterize the diamond films. Sliding friction experiments were conducted with a polished natural diamond pin in contact with diamond films in the three environments: humid air (40 percent relative humidity), dry nitrogen (less than 1 percent relative humidity), and ultrahigh vacuum (10(exp -7) Pa). The CVD diamond films indeed have friction and were properties similar to those of natural diamond in the three environments. The as-deposited, fine-grain diamond films can be effectively used as self-lubricating, wear-resistant coatings that have low coefficients of friction (0.02 to 0.04) and low wear rates (10(exp -7) to 10(exp -8)mm(exp 3)/N-m) in both humid air and dry nitrogen. However, they have high coefficients of friction (1.5 to 1.7) and a high wear rate (10(exp -4)mm(exp 3/N-m) in ultrahigh vacuum. The carbon ion implanation produced a thin surficial layer (less than 0.1 micron thick) of amorphous, nondiamond carbon on the diamond films. In humid air and dry nitrogen, the ion-implanted, fine- and coarse-grain diamond films have a low coefficient of friction (around 0.1) and a low wear rate (10(exp -7)mm(exp 3/N-m). Even in ultrahigh vacuum, the presence of the nondiamond carbon layer reduced the coefficient of friction of fine-grain diamond films to 0.1 or lower and the wear rate to 10(exp -6)mm(exp 3)/N-m. Thus, the carbon ion-implanted, fine-grain diamond films can be effectively used as wear-resistant, self-lubricating coatings not only in air and dry nitrogen, but also in ultrahigh vacuum. The wear mechanism of diamond films is that of small fragments chipping off the surface. The size of wear particles is related to the extent of wear rates.

Miyoshi, Kazuhisa↗

Adhesive Wear of Rollers in Vacuum

This work was done to support NASA's James Webb Space Telescope that is equipped with a Near Infrared Camera and Spectrograph and Micro Shutter Assembly (MSA). A MSA mechanism's qualification test in cryogenic vacuum at 30deg K for 96K cycles resulted in roller wear and formation of some debris. Lab tests in vacuum were conducted at NASA Glenn Research Center (GRC) to understand the wear of Ti6Al4V mated with 440F steel rollers. Misalignment angle was found to have the most significant effect on debris formation. At misalignment angle of 1.4deg, significant amount of wear debris were formed within 50,000 cycles. Very few wear particles were found for a zero misalignment angle, and the total wear was small even after 367,000 cycles. The mode of wear in all the tests was attributed to adhesion, which was clearly evident from video records as well as the plate-like amalgamated debris material from both rollers. The adhesive wear rate was found to be approximately proportional to the misalignment angle. The wear is a two-way phenomenon, and the mixing of both roller materials in wear debris was confirmed by x-ray fluorescence (XRF) and EDX spectra. While there was a net loss of mass from the steel rollers, XRF and energy dispersive x-ray (EDX) spectra showed peaks of Ti on steel rollers, and peaks of Fe on Ti rollers. These results are useful for designers in terms of maintaining appropriate tolerances to avoid misalignment of rolling elements and the resulting severe wear

Shaeef, Iqbal↗

Wear Behavior of Vanadium and V-Ti-Ta Alloys under Reciprocating Sliding Conditions

Vanadium and newly developed V-Ti-Ta alloys have been systematically investigated for wear characteristics using ball-on-flat reciprocative sliding experiments. These materials have been tested at different sliding conditions (load and frequency) against hardened steel (AFBMA Grade 10) ball as counter-body. Coefficient of friction, wear volume and specific wear rate were measured and evaluated. Friction coefficient of vanadium and its alloys increases with increase in applied load irrespective of sliding frequencies. Wear rate decreases with increase in alloying content. Among the investigated compositions, V-4Ti-7Ta alloy exhibited superior wear performance having a least wear rate of 3.06 × 10{sup −6} mm{sup 3}/Nm, which is three times lower as compared with unalloyed vanadium when tested at 5 N and 5 Hz conditions. Addition of Ti and Ta strengthens the vanadium matrix by solid solution and contributes to enhanced wear resistance of the material without affecting the friction coefficient values. The major phases identified in the wear track regions were V{sub 2}O{sub 5} and Fe{sub 0.11}V{sub 2}O{sub 5.15}. Microstructural investigation reveals the predominant presence of adhesive wear regions at higher loads (15 N).

36 MATERIALS SCIENCE↗

Sensor selection and tool wear prediction with data‐driven models for precision machining

Abstract Estimation of tool wear in precision machining is vital in the traditional subtractive machining industry to reduce processing cost, improve manufacturing efficiency and product quality. In this vein, fusion of time and frequency‐domain features of commonly sensed signals can provide an early indication of tool wear and improve its prediction accuracy for prognostics and health management. This paper presents a data‐driven methodology and a complete tool chain for the inference of precision machining tool wear from fused machine measurements, such as cutting force, power, audio and vibration signals, and quantify the usefulness of each measurement. Indicators of tool wear are extracted from time‐domain signal statistics, frequency‐domain analysis, and time‐frequency domain analysis. Correlation coefficients between the extracted features (indicators) and the tool wear are used to select the most informative features. Principal Component Analysis and Partial Least‐Squares are used to reduce the dimensionality of the feature space. Regression models, including linear regression, support vector regression, Decision tree regression, neural network regression and Gaussian process regression, are used to predict the tool wear using data from a Haas milling machine performing spiral boss face milling. The performance of the regression models based on subsets of sensors validates the preliminary estimates about the saliency of the sensors. The experimental results show that the proposed methods can predict the machine tool wear precisely, with readily available sensor measurements. Neural network and Gaussian process regression were able to achieve good estimates of tool wear at different machine operating conditions. The most informative signal in predicting tool wear was shown to be the vibration signal. Time‐frequency domain features were the most informative features among the combination of features of three domains. In addition, using partial least squares components extracted from the original features of signals led to higher prediction accuracy.

Han, Seulki↗

A comparative wear study on Al-Li and Al-Li/SiC composite

Aluminum-lithium based unreinforced (Al-8090) alloy and Al-8090/SiCp/17 vol.% metal matrix composite produced by extrusion after spray co-deposition. A dry ball-on disk wear test was carried out for both alloy and composite. The tests were performed against an Al{sub 2}O{sub 3} ball, 10 mm in diameter, at room temperature and in laboratory air conditions with a relative humidity of 40-60%. Sliding speed was chosen as 1.0 ms{sup −1} and normal loads of 1.0, 3.0 and 5.0 N were employed at a constant sliding distance of 1000 m. The wear damage on the specimens was evaluated via measurement of wear depth and diameter. Microstructural and wear characterization was carried out via scanning electron microscopy (SEM). The results showed that wear loss of the Al-8090/SiC composite was less than that of the Al-8090 matrix alloy. Plastic deformation observed on the wear surface of the composite and the matrix alloy, and the higher the applied load the greater the plastic deformation. Scanning electron microscopy examinations of wear tracks also reveal that delamination fracture was the dominant wear mechanism during the wear progression. Friction coefficient was maximum at the low applied load in the case of the Al-8090/SiC composite while a gradual increase was observed with applied load for the matrix alloy.

36 MATERIALS SCIENCE↗

The effect of Tricresyl-Phosphate (TCP) as an additive on wear of Iron (Fe)

The effect of tricresyl phosphate (TCP) as an antiwear additive in lubricant trimethyol propane triheptanoate (TMPTH) was investigated. The objective was to examine step loading wear by use of surface analysis, wetting, and chemical bonding changes in the lubricant. The investigation consisted of steploading wear studies by a pin or disk tribometer, the effects on wear related to wetting by contact angle and surface tension measurements of various liquid systems, the chemical bonding changes between lubricant and TCP chromatographic analysis, and by determining the reaction between the TCP and metal surfaces through wear scar analysis by Auger emission spectroscopy (AES). The steploading curve for the base fluid alone shows rapid increase of wear rate with load. The steploading curve for the base fluid in presence of 4.25 percent by volume TCP under dry air purge has shown a great reduction of wear rate with all loads studied. It has also been found that the addition of 4.25 percent by volume TCP plus 0.33 percent by volume water to the base lubricant under N2 purge also greatly reduces the wear rate with all loads studied. AES surface analysis reveals a phosphate type wear resistant film, which greatly increases load-bearing capacity, formed on the iron disk. Preliminary chromatographic studies suggest that this film forms either because of ester oxidation or TCP degradation. Wetting studies show direct correlation between the spreading coefficient and the wear rate.

Ghose, Hiren M.↗

Wear of Spur Gears Having a Dithering Motion and Lubricated with a Perfluorinated Polyether Grease

Gear contact surface wear is one of the important failure modes for gear systems. Dedicated experiments are required to enable precise evaluations of gear wear for a particular application. The application of interest for this study required evaluation of wear of gears lubricated with a grade 2 perfluorinated polyether grease and having a dithering (rotation reversal) motion. Experiments were conducted using spur gears made from AISI 9310 steel. Wear was measured using a profilometer at test intervals encompassing 10,000 to 80,000 cycles of dithering motion. The test load level was 1.1 GPa maximum Hertz contact stress at the pitch-line. The trend of total wear as a function of test cycles was linear, and the wear depth rate was approximately 1.2 nm maximum wear depth per gear dithering cycle. The observed wear rate was about 600 times greater than the wear rate for the same gears operated at high speed and lubricated with oil.

Krantz, Timothy↗

Fretting Wear of Ti-48Al-2Cr-2Nb

An investigation was conducted to examine the wear behavior of gamma titanium aluminide (Ti-48Al-2Cr-2Nb in atomic percent) in contact with a typical nickel-base superalloy under repeated microscopic vibratory motion in air at temperatures from 296-823 K. The surface damage observed on the interacting surfaces of both Ti-48Al-2Cr-2Nb and superalloy consisted of fracture pits, oxides, metallic debris, scratches, craters, plastic deformation, and cracks. The Ti-48Al-2Cr-2Nb transferred to the superalloy at all fretting conditions and caused scuffing or galling. The increasing rate of oxidation at elevated temperatures led to a drop in Ti-48Al-2Cr-2Nb wear at 473 K. Mild oxidative wear was observed at 473 K. However, fretting wear increased as the temperature was increased from 473-823 K. At 723 and 823 K, oxide disruption generated cracks, loose wear debris, and pits on the Ti-48Al-2Cr-2Nb wear surface. Ti-48Al-2Cr-2Nb wear generally decreased with increasing fretting frequency. Both increasing slip amplitude and increasing load tended to produce more metallic wear debris, causing severe abrasive wear in the contacting metals. Keywords

Miyoshi, Kazuhisa↗

Assessment of wear coefficients of nuclear zirconium claddings without and with pre-oxidation

In the cores of pressurized water nuclear reactors, water-flow induced vibration is known to cause claddings on the fuel rods to rub against their supporting grids. Such grid-to-rod-fretting (GTRF) may lead to fretting wear-through and the leakage of radioactive species. The surfaces of actual zirconium alloy claddings in a reactor are inevitably oxidized in the high-temperature pressurized water, and some claddings are even pre-oxidized. As a result, the wear process of the surface oxide film is expected to be quite different from the zirconium alloy substrate. In this paper, we attempt to measure the wear coefficients of zirconium claddings without and with pre-oxidation rubbing against grid samples using a bench-scale fretting tribometer. Results suggest that the volumetric wear coefficient of the pre-oxidized cladding is 50 to 200 times lower than that of the untreated cladding. In terms of the linear rate of wear depth, the pre-oxidized alloy wears about 15 times more slowly than the untreated cladding. Finally, fitted with the experimentally-determined wear rates, a stage-wise GTRF engineering wear model demonstrates good agreement with in-reactor experience in predicting the trend of cladding lives.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EVALUATION AND RECOMMENDATION OF SALTSTONE MIXER AUGER/PADDLES MATERIALS OF CONSTRUCTION FOR IMPROVED WEAR RESISTANCE

Wear and corrosion testing were conducted to evaluate alternate materials of construction for the Saltstone mixer auger and paddles. These components have been degraded by wear from the slurry processed in the mixer. Material test options included PVD coatings (TiN, TiCN, and ZrN), weld overlays (Stellite 12 and Ultimet) and higher hardness steels and carbides (D2 and tungsten carbide). The corrosion testing demonstrated that the slurry is not detrimental to the current materials of construction or the new candidates. The ASTM G75 Miller wear test showed that the high hardness materials and the Stellite 12 weld overlay provide superior wear relative to the Astralloy and CF8M stainless steel, which are the current materials of construction, as well as the PVD coatings and Ultimet. The following recommendations are made for selecting new material options and improving the overall wear resistance of the Saltstone mixer components: • A Stellite 12 weld overlay or higher hardness steel (with toughness equivalent to Astralloy) be used to improve the wear resistance of the Saltstone mixer paddles; other manufacturing specifications for the mixer need to be considered in this selection. • The current use of the Stellite 12 weld overlay be evaluated so that coverage of the 316 auger can be optimized for improved wear resistance of the auger. • The wear surfaces of the Saltstone mixer auger and paddles be evaluated so that laboratory data can be better correlated to actual service. • The 2-inch Saltstone mixer prototype be used to verify material performance.

36 MATERIALS SCIENCE↗

Achieving Ultralow Wear with Stable Nanocrystalline Metals

Recent work suggests that thermally stable nanocrystallinity in metals is achievable in several binary alloys by modifying grain boundary energies via solute segregation. The remarkable thermal stability of these alloys has been demonstrated in recent reports, with many alloys exhibiting negligible grain growth during prolonged exposure to near-melting temperatures. In this paper, we show that PtAu, a proposed stable alloy consisting of two noble metals, exhibits extraordinary resistance to wear. Ultra-low wear rates, less than a monolayer of material removed per sliding pass, were measured for PtAu thin films at a maximum Hertz contact stress of up to 1.1 GPa. This is the first instance of an all-metallic material exhibiting a specific wear rate on the order of 10 -9 mm 3 /N-m, comparable to diamond-like carbon and sapphire. Remarkably, the wear rate of sapphire and silicon nitride probes used in wear experiments were either higher or comparable to that of the PtAu alloy, despite the substantially higher hardness of the ceramic probe materials. High-resolution microscopy showed negligible surface microstructural evolution in the wear tracks after 100k sliding passes. Finally, mitigation of fatigue-driven delamination enabled a transition to wear by atomic attrition, a regime previously limited to highly wear resistant materials such as diamond-like carbon.

36 MATERIALS SCIENCE↗

Measuring the Wear and Abrasive Resistance of Air Plasma Sprayed Aluminum Oxide for Lunar Exploration

Lunar regolith, especially finer dust particles traveling at high velocities, can cause significant wear and abrasive damage to structural components that ensure a prolongated presence on the surface of the Moon. With the absence of an atmosphere and lower gravity than on Earth, regolith particles maintain high velocities at large distances from where they were generated, for example next to lunar landers. Wear-resistant ceramic and ceramic composite materials can improve the durability of spacecraft components during long missions on the Moon’s surface. Aluminum oxide coatings are lightweight, have multifunctional properties, and have high strength including high hardness and wear resistance. These properties can help improve the durability of structures used in space exploration. Air plasma sprayed (APS) aluminum oxide coatings have demonstrated the potential to protect critical structures. This study investigated the abrasive wear resistance of APS aluminum oxide coatings via Taber abrasion experiments. Taber abrasion offers the advantage of quantifying the abrasive wear behavior of particles with different shapes on a surface. In this work, an abrasive wheel made of silicon carbide was utilized to evaluate wear properties of specimens progressively over 5000 cycles. This experiment focused on testing two series of specimens to determine whether a bond coat composed of nickel, chromium, aluminum, and yttrium (NiCrAlY) improved the protective behavior of the APS aluminum oxide coating. The specimens varied in topcoat thickness and were made with and without an approximately 100 µm bond coat layer. The mass of the specimens was measured at 400 cycles, 800 cycles, 3800 cycles, and 5000 cycles. Increasing thickness was found to result in higher wear for samples with and without a bond coat. Increased mass loss in samples with a bond coat was observed indicating a need for further studies on the overall impact of the use of a bond coat on the protective behavior of the coatings. To continue designing wear resistant coatings for structural protection in space missions, the multifunctional properties of the APS aluminum oxide coating will be studied. Future experiments will determine whether the APS aluminum oxide coating can protect the structures from other aspects of the harsh space environment, such as extreme temperature variations and ionizing radiation.

aluminum oxide↗

Wear Measurement of Highly Cross-linked UHMWPE using a 7 Be Tracer Implantation Technique

The very low wear rates achieved with the current highly cross-linked ultrahigh molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are there- fore being explored. The purpose of this study was to perform a proof-of-concept experiment on the use of the radioactive tracer beryllium-7 (7Be) for the determination of in vitro wear in a highly cross-linked orthopedic UHMWPE. Three cross-linked and four conventional UHMWPE pins made from compression- molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei up to 8.5 lm below the surface. The pins were tested for wear in a six-station pin-on-flat appara- tus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and esti- mated to be 17 6 3 lg per million cycles. The conventional-to- cross-linked ratio of the wear rates was 13.1 6 0.8, in the expected range for these materials. Oxidative degradation dam- age from implantation was negligible; however, a weak depend- ence of wear on implantation dose was observed limiting the number of radioactive tracer atoms that can be introduced. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.

cross-linked↗

Achieving Ultralow Wear with Stable Nanocrystalline Metals

Abstract Recent work suggests that thermally stable nanocrystallinity in metals is achievable in several binary alloys by modifying grain boundary energies via solute segregation. The remarkable thermal stability of these alloys has been demonstrated in recent reports, with many alloys exhibiting negligible grain growth during prolonged exposure to near‐melting temperatures. Pt–Au, a proposed stable alloy consisting of two noble metals, is shown to exhibit extraordinary resistance to wear. Ultralow wear rates, less than a monolayer of material removed per sliding pass, are measured for Pt–Au thin films at a maximum Hertz contact stress of up to 1.1 GPa. This is the first instance of an all‐metallic material exhibiting a specific wear rate on the order of 10 −9 mm 3 N −1 m −1 , comparable to diamond‐like carbon (DLC) and sapphire. Remarkably, the wear rate of sapphire and silicon nitride probes used in wear experiments are either higher or comparable to that of the Pt–Au alloy, despite the substantially higher hardness of the ceramic probe materials. High‐resolution microscopy shows negligible surface microstructural evolution in the wear tracks after 100k sliding passes. Mitigation of fatigue‐driven delamination enables a transition to wear by atomic attrition, a regime previously limited to highly wear‐resistant materials such as DLC.

Curry, John F.↗