Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WALTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

CHANG-ES V: NUCLEAR OUTFLOW IN A VIRGO CLUSTER SPIRAL AFTER A TIDAL DISRUPTION EVENT

We have observed the Virgo Cluster spiral galaxy, NGC 4845, at 1.6 and 6 GHz using the Karl G. Jansky Very Large Array, as part of the Continuum Halos in Nearby Galaxies—an EVLA Survey (CHANG-ES). The source consists of a bright unresolved core with a surrounding weak central disk (1.8 kpc diameter). The core is variable over the 6 month timescale of the CHANG-ES data and has increased by a factor of ≈6 since 1995. The wide bandwidths of CHANG-ES have allowed us to determine the spectral evolution of this core, which peaks between 1.6 and 6 GHz (it is a Gigahertz-peaked spectrum source). We show that the spectral turnover is dominated by synchrotron self-absorption and that the spectral evolution can be explained by adiabatic expansion (outflow), likely in the form of a jet or cone. The CHANG-ES observations serendipitously overlap in time with the hard X-ray light curve obtained by Nikolajuk and Walter (2013), which they interpret as due to a tidal disruption event (TDE) of a super-Jupiter mass object around a 10{sup 5} M{sub ⊙} black hole. We outline a standard jet model, provide an explanation for the observed circular polarization, and quantitatively suggest a link between the peak radio and peak X-ray emission via inverse Compton upscattering of the photons emitted by the relativistic electrons. We predict that it should be possible to resolve a young radio jet via VLBI as a result of this nearby TDE.

79 ASTRONOMY AND ASTROPHYSICS↗

A passion for theoretical physics: a special issue in memory of Peter G O Freund

This is a preface to A Passion for Theoretical Physics, a special issue collection of articles published in J. Phys. A in memory of Peter G. O. Freund. We dedicate this special issue to the memory of our esteemed colleague, inspiring teacher and cherished friend, Peter Freund. Peter George Oliver Freund was born on 7 September 1936 in Timisoara, Romania. He obtained his PhD under the supervision of Walter Thirring at the University of Vienna in 1960. He came to the University of Chicago in 1963, where he remained throughout his career. He passed away on 6 March 2018.

97 MATHEMATICS AND COMPUTING↗

Quantum Complexity of the Kronecker Coefficients

Whether or not the Kronecker coefficients of the symmetric group count some set of combinatorial objects is a longstanding open question. In this work we show that a given Kronecker coefficient is proportional to the rank of a projector that can be measured efficiently using a quantum computer. In other words a Kronecker coefficient counts the dimension of the vector space spanned by the accepting witnesses of a QMA verifier, where QMA is the quantum analogue of NP . This implies that approximating the Kronecker coefficients to within a given relative error is not harder than a certain natural class of problems that captures the complexity of estimating thermal properties of quantum many-body systems. A second consequence is that deciding positivity of Kronecker coefficients is contained in QMA , complementing a recent NP -hardness result of Ikenmeyer, Mulmuley, and Walter. We obtain similar results for the related problem of approximating row sums of the character table of the symmetric group. Finally, we discuss an efficient quantum algorithm that approximates normalized Kronecker coefficients to inverse-polynomial additive error. Published by the American Physical Society 2024

Physics↗

CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions

Purpose: To measure radiation absorbed dose and its distribution in an anthropomorphic head phantom under clinically representative scan conditions in three widely used computed tomography (CT) scanners, and to relate those dose values to metrics such as high-contrast resolution, noise, and contrast-to-noise ratio (CNR) in the American College of Radiology CT accreditation phantom.Methods: By inserting optically stimulated luminescence dosimeters (OSLDs) in the head of an anthropomorphic phantom specially developed for CT dosimetry (University of Florida, Gainesville), we measured dose with three commonly used scanners (GE Discovery CT750 HD, Siemens Definition, Philips Brilliance 64) at two different clinical sites (Walter Reed National Military Medical Center, National Institutes of Health). The scanners were set to operate with the same data-acquisition and image-reconstruction protocols as used clinically for typical head scans, respective of the practices of each facility for each scanner. We also analyzed images of the ACR CT accreditation phantom with the corresponding protocols. While the Siemens Definition and the Philips Brilliance protocols utilized only conventional, filtered back-projection (FBP) image-reconstruction methods, the GE Discovery also employed its particular version of an adaptive statistical iterative reconstruction (ASIR) algorithm that can be blended in desired proportions with the FBP algorithm. We did an objective image-metrics analysis evaluating the modulation transfer function (MTF), noise power spectrum (NPS), and CNR for images reconstructed with FBP. For images reconstructed with ASIR, we only analyzed the CNR, since MTF and NPS results are expected to depend on the object for iterative reconstruction algorithms.Results: The OSLD measurements showed that the Siemens Definition and the Philips Brilliance scanners (located at two different clinical facilities) yield average absorbed doses in tissue of 42.6 and 43.1 mGy, respectively. The GE Discovery delivers about the same amount of dose (43.7 mGy) when run under similar operating and image-reconstruction conditions, i.e., without tube current modulation and ASIR. The image-metrics analysis likewise showed that the MTF, NPS, and CNR associated with the reconstructed images are mutually comparable when the three scanners are run with similar settings, and differences can be attributed to different edge-enhancement properties of the applied reconstruction filters. Moreover, when the GE scanner was operated with the facility's scanner settings for routine head exams, which apply 50% ASIR and use only approximately half of the 100%-FBP dose, the CNR of the images showed no significant change. Even though the CNR alone is not sufficient to characterize the image quality and justify any dose reduction claims, it can be useful as a constancy test metric.Conclusions: This work presents a straightforward method to connect direct measurements of CT dose with objective image metrics such as high-contrast resolution, noise, and CNR. It demonstrates that OSLD measurements in an anthropomorphic head phantom allow a realistic and locally precise estimation of magnitude and spatial distribution of dose in tissue delivered during a typical CT head scan. Additional objective analysis of the images of the ACR accreditation phantom can be used to relate the measured doses to high contrast resolution, noise, and CNR.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-AB-206-00: Diagnostic QA/QC Hands-On Workshop

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-AB-206-03: Workshop

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Right Time at the Right Places

In my undergraduate studies at the Massachusetts Institute of Technology (MIT), the short-lived chemical physics major allowed me to evade a number of courses required for chemistry majors. Thus, it was possible to take many physics courses and most of the advanced PhD-level courses in physical chemistry. I also took the introductory electrical engineering course in computer programming. The latter allowed me to write lots of computer code as a part of my (passing, but largely unsuccessful) senior thesis directed graciously by Professor Walter Thorson. As recommended by MIT Professor John C. Slater, I moved to Stanford University with Professor Frank Harris as my PhD supervisor. Frank was the perfect advisor for me, providing very close direction during the first year, and then allowing me to develop more and more independently. Within a few days of my twenty-fifth birthday, I became an assistant professor of chemistry at the University of California, Berkeley. Eighteen years later, I moved to the University of Georgia as director of a new research institute.

autobiography↗

Coda Envelope Ratio Tool

The Coda Envelope Ratio Tool (CERT) allows for calculating seismic envelopes from waveforms and measuring the amplitude ratios for multiple events against each other to invert for seismic source information. The methodology is based on Walter, W. R., Yoo, S.-H., Mayeda, K., and Gök, R. (2017), Earthquake stress via event ratio levels: Application to the 2011 and 2016 Oklahoma seismic sequences, Geophys. Res. Lett., 3147- 3155, 44, doi:10.1002/2016GL072348.

Barno, JustinG↗

PLUMES 2.0

PLUMES2.0 is a revived version of the Visual Plumes model that was developed by Dr. Walter Frick at USEPA. PLUMES2.0 and Visual Plumes are codes that compute initial and far-field dilution of buoyant discharges into receiving fresh or marine environments.

Premathilake, LakshithaLaki↗

Pathosphere.org: pathogen detection and characterization through a web-based, open source informatics platform

The detection of pathogens in complex sample backgrounds has been revolutionized by wide access to next-generation sequencing (NGS) platforms. However, analytical methods to support NGS platforms are not as uniformly available. Pathosphere (found at Pathosphere.org) is a cloud - based open - sourced community tool that allows for communication, collaboration and sharing of NGS analytical tools and data amongst scientists working in academia, industry and government. The architecture allows for users to upload data and run available bioinformatics pipelines without the need for onsite processing hardware or technical support. The pathogen detection capabilities hosted on Pathosphere were tested by analyzing pathogen-containing samples sequenced by NGS with both spiked human samples as well as human and zoonotic host backgrounds. Pathosphere analytical pipelines developed by Edgewood Chemical Biological Center (ECBC) identified spiked pathogens within a common sample analyzed by 454, Ion Torrent, and Illumina sequencing platforms. ECBC pipelines also correctly identified pathogens in human samples containing arenavirus in addition to animal samples containing flavivirus and coronavirus. These analytical methods were limited in the detection of sequences with limited homology to previous annotations within NCBI databases, such as parvovirus. Utilizing the pipeline-hosting adaptability of Pathosphere, the analytical suite was supplemented by analytical pipelines designed by the United States Army Medical Research Institute of Infectious Diseases and Walter Reed Army Institute of Research (USAMRIID-WRAIR). These pipelines were implemented and detected parvovirus sequence in the sample that the ECBC iterative analysis previously failed to identify. By accurately detecting pathogens in a variety of samples, this work demonstrates the utility of Pathosphere and provides a platform for utilizing, modifying and creating pipelines for a variety of NGS technologies developed to detect pathogens in complex sample backgrounds. These results serve as an exhibition for the existing pipelines and web-based interface of Pathosphere as well as the plug-in adaptability that allows for integration of newer NGS analytical software as it becomes available.

59 BASIC BIOLOGICAL SCIENCES↗

The Effects of Assumed Source Depth and Shear-Wave Velocity on Moment Tensors Estimated for Small, Contained Chemical Explosions in Granite

ABSTRACT The Source Phenomenology Experiment (SPE-Arizona) included of a series of chemical explosions detonated within a copper mine in Arizona. This study focuses on ground motions from detonations in the copper mine, which are analyzed to assess the uniqueness of the resulting source representation when the source region propagation characteristics have a range of possible models. P-wave velocities are well constrained by refraction data with less constraint of the S-wave velocities. The effects of explosion source depth and VS are assessed with Green’s functions for a range of models in which VP is held constant. Propagation models with a Poisson’s value of 0.25 and a source depth 30–60 m most accurately replicate the data. The explosion was detonated at a centroid depth of 30 m, so trade-offs in depth are demonstrated. The compensated linear vector dipole and explosion components of the Green’s functions convolved with a Mueller–Murphy source function are compared. Both produce significant energy in the 2–12 Hz band, due to surface-wave contributions with no clear depth dependencies above 20 Hz. The range of propagation models is used with the observational data to invert for the frequency-domain moment tensor. Fits to the data from these inversions have cross-correlation values of 0.64, demonstrating effectiveness in replicating the observations with the assumed propagation path effects and resulting source function. Inversions produce horizontal dipoles (Mxx and Myy), roughly half the maximum amplitude of Mzz, consistent with a compensated linear vector dipole source, which is frequency dependent. Denny and Johnson, Mueller–Murphy, Walter and Ford, and the revised Mueller–Murphy source models, parameterized for granite, are compared to the moment tensors. Despite a nonisotropic moment tensor source, the revised Mueller–Murphy isotropic source model best replicates the long-period moments, overshoot, and corner frequency.

Geochemistry & Geophysics↗

Comparison of the PLTEMP code flow instability predictions with measurements made with electrically heated channels for the advanced test reactor.

When the University of Missouri Research Reactor (MURR) was designed in the 1960s the potential for fuel element burnout by a phenomenon referred to at that time as 'autocatalytic vapor binding' was of serious concern. This type of burnout was observed to occur at power levels considerably lower than those that were known to cause critical heat flux. The conversion of the MURR from HEU fuel to LEU fuel will probably require significant design changes, such as changes in coolant channel thicknesses, that could affect the thermal-hydraulic behavior of the reactor core. Therefore, the redesign of the MURR to accommodate an LEU core must address the same issues of fuel element burnout that were of concern in the 1960s. The Advanced Test Reactor (ATR) was designed at about the same time as the MURR and had similar concerns with regard to fuel element burnout. These concerns were addressed in the ATR by two groups of thermal-hydraulic tests that employed electrically heated simulated fuel channels. The Croft (1964), Reference 1, tests were performed at ANL. The Waters (1966), Reference 2, tests were performed at Hanford Laboratories in Richland Washington. Since fuel element surface temperatures rise rapidly as burnout conditions are approached, channel surface temperatures were carefully monitored in these experiments. For self-protection, the experimental facilities were designed to cut off the electric power when rapidly increasing surface temperatures were detected. In both the ATR reactor and in the tests with electrically heated channels, the heated length of the fuel plate was 48 inches, which is about twice that of the MURR. Whittle and Forgan (1967) independently conducted tests with electrically heated rectangular channels that were similar to the tests by Croft and by Walters. In the Whittle and Forgan tests the heated length of the channel varied among the tests and was between 16 and 24 inches. Both Waters and Whittle and Forgan show that the cause of the fuel element burnout is due to a form of flow instability. Whittle and Forgan provide a formula that predicts when this flow instability will occur. This formula is included in the PLTEMP/ANL code.Error! Reference source not found. Olson has shown that the PLTEMP/ANL code accurately predicts the powers at which flow instability occurs in the Whittle and Forgan experiments. He also considered the electrically heated tests performed in the ANS Thermal-Hydraulic Test Loop at ORNL and report by M. Siman-Tov et al. The purpose of this memorandum is to demonstrate that the PLTEMP/ANL code accurately predicts the Croft and the Waters tests. This demonstration should provide sufficient confidence that the PLTEMP/ANL code can adequately predict the onset of flow instability for the converted MURR. The MURR core uses light water as a coolant, has a 24-inch active fuel length, downward flow in the core, and an average core velocity of about 7 m/s. The inlet temperature is about 50 C and the peak outlet is about 20 C higher than the inlet for reactor operation at 10 MW. The core pressures range from about 4 to about 5 bar. The peak heat flux is about 110 W/cm{sup 2}. Section 2 describes the mechanism that causes flow instability. Section 3 describes the Whittle and Forgan formula for flow instability. Section 4 briefly describes both the Croft and the Waters experiments. Section 5 describes the PLTEMP/ANL models. Section 6 compares the PLTEMP/ANL predictions based on the Whittle and Forgan formula with the Croft measurements. Section 7 does the same for the Waters measurements. Section 8 provides the range of parameters for the Whittle and Forgan tests. Section 9 discusses the results and provides conclusions. In conclusion, although there is no single test that by itself closely matches the limiting conditions in the MURR, the preponderance of measured data and the ability of the Whittle and Forgan correlation, as implemented in PLTEMP/ANL, to predict the onset of flow instability for these tests leads one to the conclusion that the same method should be able to predict the onset of flow instability in the MURR reasonably well.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Biosecurity management recommendations for rinderpest laboratories

Rinderpest is a virus that can affect cattle and other even toes ungulates; evidence of outbreaks from over 10,000 years ago highlights the potential impact of this virus. During the 18th century, Rinderpest caused huge losses in cattle throughout Europe. Starting in the mid 1900’s vaccination efforts seemed feasible and work was initiated to vaccinate large populations of cattle. Walter Plowright received numerous awards for updating the Rinderpest vaccine which many believed would be the key to eradication. Vaccination of the disease lead to a massive drop in outbreaks and the last confirmed case of Rinderpest in Asia was in 2000 and in Africa in 2001.1 At this point, Rinderpest has been declared eradicated from nature. However, stocks of the virus are still in many laboratories.2 Rinderpest was investigated as a biological weapon agent during the Second World War. However, following WWII, rinderpest was not considered a high risk as a biological weapon as there was no direct military advantage. Now, with the concern of the use of biological agents as weapons in acts of terrorism, concern regarding rinderpest has resurfaced. Since the eradication of this virus, cattle populations are highly susceptibility to the virus and the economic impacts would be significant. This paper will discuss the specific nature of the terrorism risks associated with rinderpest; and based upon those risks provide recommendations regarding biosecurity management. The biosecurity management measures will be defined in a manner to align with the CWA 15793: the laboratory biorisk management document.

60 APPLIED LIFE SCIENCES↗

2017 Report for New LANL Physical Vapor Deposition Capability

There is an urgent need at LANL to achieve uniform, thin film actinide targets that are essential for nuclear physics experiments. The target preparation work is currently performed externally by Professor Walter Loveland at Oregon State University, who has made various evaporated actinide targets such as Th and U for use on several nuclear physics measurements at LANSCE. We are developing a vapor deposition capability, with the goal of evaporating Th and U in the Actinide Research Facility (ARF) at TA-48. In the future we plan to expand this work to evaporating transuranic elements, such as Pu. The ARF is the optimal location for evaporating actinides because this lab is specifically dedicated to actinide research. There are numerous instruments in the ARF that can be used to provide detailed characterization of the evaporated thin films such as: Table top Scanning Electron Microscope, In-situ X-Ray Diffraction, and 3D Raman spectroscopy. These techniques have the ability to determine the uniformity, surface characterization, and composition of the deposits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aftershocks of a Chemical Explosion in Granite from the Source Physics Experiment Phase I

The Source Physics Experiment (SPE) is a multiphase experiment to better understand explosion source physics and thereby improve explosion monitoring. The rst phase (Phase I) examined the explosion source in a hard-rock medium and took place in a granite outcrop called the Climax Stock section of the Nevada National Security Site (NNSS). This series of chemical explosions are called the Wet Granite Geology (WGG) events, but are usually referred to simply as the SPE events (i.e., SPE-1, SPE-2, etc.). Event information for the chemical explosions is given in Table 1. The study of explosion aftershocks can aid in understanding of in-situ stresses and be used as a discriminant for earthquakes [Ford and Walter, 2010]. Sweeney and Harben reported no observed aftershocks for SPE-1 and -2, respectively. They calculated a minimum magnitude of observation based on the noise oor of the seismic array and predicted at least one or two events in the week after the events using the hard-rock aftershock model from Ford and Labak. Possible explanations for the null observation ranged from instrumental - poor seismometer coupling, to physical - the shallow depth of burial was unable to access the deep tectonic stress that causes some explosion aftershocks. We extend the analysis of Sweeney and Harben to the largest of the SPE Phase I chemical explosions, SPE-5, which was approximately a 5 tonne TNT-equivalent shot at 76.5 m depth. This event registered as an M L 2 on the University of Nevada, Reno seismic network and should produce a measurable aftershock sequence.

58 GEOSCIENCES↗

Draft Electric Rule 21 Test Protocols for Advanced Inverter Functions

Disclaimer: The following document includes draft certification protocols and should not be viewed as a consensus-based performance standard. Distributed energy resources (DERs), such as photovoltaic (PV) systems, when deployed in a large scale, are capable of significantly influencing the operation of bulk and local power systems. Looking to the future, European and American stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. One of the jurisdictions considering modifications to the DER interconnection requirements is California. To determine what changes could improve electric grid reliability and allow greater penetrations of renewable energy, the California Public Utilities Commission (CPUC) and the California Energy Commission (CEC), in conjunction with consultant Frances Cleveland, convened the Smart Inverter Working Group (SIWG) in January 2013. The SIWG--composed of state agencies, utility engineers, national laboratories, manufacturers, trade associations, and advocacy groups--provided the CPUC a set of recommendations in early 2014 1 . The recommendations included specific advanced DER functions and interoperability requirements, along with a proposed timeline, for California to add new capabilities to grid-interconnected DER. On August 18, 2014 the three California Investor-Owned Utilities (IOUs)--Pacific Gas and Electric Company (PG&E), Southern California Edison Company (SCE) and San Diego Gas & Electric Company (SDG&E)--drafted a Advice Letter filing to the CPUC setting forth revisions to Electric Tariff Rule 21 to conform to the seven recommendations made by the Working Group 2 . After a comment period, the CPUC issued an update to the IOU recommendations 3 . At the time of this publication, there was no final legal ruling on the CPUC Rulemaking (R.) 11-09-011 ("Order Instituting Rulemaking on the Commission's Own Motion to improve distribution level interconnection rules and regulations for certain classes of electric generators and electric storage resources"). In the U.S., Nationally Recognized Test Laboratories (NRTLs) independently verify products to safety and functional standards. PV inverters are certified to Underwriters Laboratories (UL) Standard 1741 4 . However, new advanced inverter functions described in the SIWG and IOU proposals are not included in this standard, so there is a critical need to develop test protocols for these functions in preparation of a positive ruling by the CPUC. Through a California Solar Initiative Grant, Sandia National Laboratories (Sandia or SNL), Underwriters Laboratories (UL), Electric Power Research Institute, Inc. (EPRI), Xanthus Consulting, SunSpec Alliance, Loggerware, and utility and PV inverter manufacturers have collaborated to draft this certification protocol for the Rule 21 SIWG Phase 1 advanced inverter functions. This report also includes test procedures for Phase 2 and Phase 3 functions that will be demonstrated later in the CSI4 project. This collaborative effort was performed in close junction with the UL 1741 Standards Technical Panel (STP) working group. This document represents a snapshot of the draft testing protocols at the time of publication and not a consensus certification protocol for advanced inverters. 1 California Public Utilities Commission, "Recommendations for Updating the Technical Requirements for Inverters in Distributed Energy Resources, Smart Inverter Working Group Recommendations," Filed 7 Feb 2014. 2 J.J. Newlander, R.G. Litteneker, S.W. Walter, M. Dwyer, Joint motion of Pacific Gas and Electric Company (U 39 E), Southern California Edison Company (U 338 E) and San Diego Gas & Electric Company (U 902 E) regarding implementation of smart inverter functionalities, Rulemaking 11-09-011 Advice Letter, 18 July, 2014. 3 J.T. Sullivan, CPUC Rulemaking 11-09-011 Agenda ID #13460, 13 Nov, 2014. 4 Underwriters Laboratories Std. 1741 Ed. 2, "Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources," 2010.

42 ENGINEERING↗

DATASET RELEASE AND QUALITY CONTROL REVIEW OF LIVERMORE NEVADA NETWORK (LNN) RECORDINGS OF A SUBSET OF NEVADA NUCLEAR SECURITY SITE NUCLEAR EXPLOSIONS FROM 1979 TO 1992.

Geophysical research on historical nuclear tests is an important aspect of future monitoring capabilities in seismic research. This research is challenging due to the limited number of digital seismic recordings during the peak of nuclear testing (1945-1992). These limited records are unique and non-reproducible data with potential high research impact. Releasing available nuclear explosion seismic records to the explosion monitoring community is thus of high value and is the motivation for this dataset release. The target of this effort was on compilation and quality control of regional seismic records of nuclear explosions recorded on Lawrence Livermore National Laboratory stations ELK, KNB, LAC, and MNV, known collectively as the Livermore National Network (LNN) (Figure 1). LNN was established in the early 1960s for the primary purpose of monitoring underground nuclear testing at the former Nevada Test Site (NTS), now known as the Nevada Nuclear Security Site (NNSS) following the signing of the Limited Test Ban Treaty (LTBT). LNN consisted initially of short-period vertical component Benioff’s recorded on film located at Mina, NV (MNV) and Kanab, Utah (KNB). LNN added two additional stations at Landers, CA (LAC) and Elko, NV (ELK) in 1967 and upgraded equipment to broadband seismometers recorded on frequency modulation (FM) tapes from 1967-1979, followed by digital recordings after 1979 (Jarpe, 1989). The digital recordings were on a variety of now obsolete media, including 9-track, Exabyte, and DAT tapes. Jarpe (1989) describes the seismic station instrumentation details over the period of deployment. LNN recorded valuable non-repeatable unique data of several hundreds of nuclear explosions at NNSS, as well as earthquakes and chemical and mining explosions (Walter, 2020). The details of these nuclear tests are provided in the Department of Energy Report NV-209 Rev 16 (DOE, 2015).

58 GEOSCIENCES↗