Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Simulating the optical properties of soot using a stochastic soot model

KL extinction measurements are common in literature concerning soot producing sprays because of their nonintrusiveness. Unfortunately, these measurements often rely on bold assumptions of uniform and monodisperse spherical particles. In this work, a Spray A case is simulated using a highly detailed 3D stochastic soot model and the measured and simulated soot volume fraction are compared. Although the simulated volume fraction magnitude is approximately correct, features are much sharper than in the measured data. Optical models based on particle shape are applied to the simulated soot particles to nd the local optical thickness. The modeled optical thickness aligns with the measured volume fraction much more closely than the simulated volume fraction indicating KL extinction measurements are not simply related to soot volume fraction.

Strickland, Tyler↗

Consequences of the failure of equipartition for the p – V behavior of liquid water and the hydration free energy components of a small protein

Earlier we showed that in the molecular dynamics simulation of a rigid model of water it is necessary to use an integration time-step δ t ≤ 0.5 fs to ensure equipartition between translational and rotational modes. Here we extend that study in the NVT ensemble to NpT conditions and to an aqueous protein. We study neat liquid water with the rigid, SPC/E model and the protein BBA (PDB ID: 1FME) solvated in the rigid, TIP3P model. We examine integration time-steps ranging from 0.5 fs to 4.0 fs for various thermostat plus barostat combinations. We find that a small δ t is necessary to ensure consistent prediction of the simulation volume. Hydrogen mass repartitioning alleviates the problem somewhat, but is ineffective for the typical time-step used with this approach. The compressibility, a measure of volume fluctuations, and the dielectric constant, a measure of dipole moment fluctuations, are also seen to be sensitive to δ t . Using the mean volume estimated from the NpT simulation, we examine the electrostatic and van der Waals contribution to the hydration free energy of the protein in the NVT ensemble. These contributions are also sensitive to δ t . In going from δ t = 2 fs to δ t = 0.5 fs, the change in the net electrostatic plus van der Waals contribution to the hydration of BBA is already in excess of the folding free energy reported for this protein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Improving Experimental Design through Uncertainty Analysis

In this paper, the development of a fission-gas collecting and physical-analysis-enabling instrument was proposed for small-volume determination. Analysis specifications require a design capable of accurately and repeatably determining volumes in the range of 0.07–2.5 mL. This system relies on a series of gas expansions originating from a cylinder with known internal volume. The combined gas law is used to derive the unknown volumes from these expansions. Initial system designs included one of two known volumes, 11.85 ± 0.34 mL and 5.807 ± 0.078 mL, with a manifold volume of 32 mL. Results obtained from modeling this system’s operation showed that 0.07 mL can be determined with a relative expanded uncertainty greater than 300% (k = 2) for a single replicate, which was unacceptable for the proposed experimental design. Initial modeling showed that the volume connecting the known volume and rodlet, i.e., the manifold volume, and the sensitivity of the pressure sensor were key contributors to the expanded uncertainty of the measured rodlet volume. The system’s design limited the available options for pressure sensors, so emphasis was placed on the design of the manifold volume. The final system design reduced the manifold volume to 17 mL. These changes in design, combined with replicate analysis, were able to reduce the relative expanded uncertainty by ±12% (k = 2) for the 0.07 mL volume.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Utah FORGE: Pump and Probe Test on an Intact Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on an intact Westerly Granite sample with a diameter of 1 inch and a height of 1 3/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally increased from 1 MPa to 17 MPa before being reduced back to 1 MPa. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Pump and Probe Test on a Mated Fracture Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on a mated fracture Westerly Granite sample with a diameter of 1 inch and a height of 2 7/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally reduced from 17 MPa to 1 MPa in 1 MPa steps. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Method for measurement of TRISO kernel and layer volumes by X-ray computed tomography

Layer dimensions are key parameters for as-fabricated tristructural-isotropic (TRISO) particle fuel as well as for post-irradiation examination of particle performance. Layer thicknesses are typically measured by optical microscopy of the particle cross section near mid-plane, while layer volumes are estimated with serial sectioning and microscopy. This method for measuring layer volumes is limited due to the resolution limit imposed by slice thickness and the effect of the polishing process on delicate irradiated particle microstructures. In this study, image processing software has been developed to segregate the three-dimensional (3D) TRISO particle images provided by x-ray computed tomography (XCT) into high-resolution volumetric data for the kernel, all particle layers, and any internal voids introduced during irradiation. These data can be used to analyze key in-reactor behaviors of TRISO particles such as kernel swelling or buffer shrinkage, which are important inputs for fuel performance modeling.

36 MATERIALS SCIENCE↗

Dataset for manuscript "Consequences of the failure of equipartition for the p-V behavior of liquid water and the hydration free energy components of a small protein"

Previously, we showed that in the molecular dynamics simulation of a rigid model of water it is necessary to use an integration time-step dt that is less than or equal to 0.5 fs to ensure equipartition between translational and rotational modes. We extended that study in the NVT ensemble to NpT conditions and to an aqueous protein. We study neat liquid water with the rigid, SPC/E model and the protein BBA (PDB ID: 1FME) solvated in the rigid, TIP3P model. We examined integration time-steps ranging from 0.5 fs to 4.0 fs for various thermostat plus barostat combinations. We find that a small time-step, dt, is necessary to ensure consistent prediction of the simulation volume. Hydrogen mass repartitioning alleviates the problem somewhat, but is ineffective for the typical time-step used with this approach. The compressibility, a measure of volume fluctuations, is seen to be sensitive to dt. Using the mean volume estimated from the NpT simulation, we examined the electrostatic and van der Waals contribution to the hydration free energy of the protein in the NVT ensemble. These contributions are also sensitive to dt. In going from a time-step of 2 fs to a time-step of 0.5 fs, the change in the net electrostatic plus van der Waals contribution to the hydration of BBA is already in excess of the folding free energy reported for this protein. The data-set contains the simulation metadata and log files that support the claims noted above.

59 BASIC BIOLOGICAL SCIENCES↗

Quasiparticle Generation-Recombination Noise in the Limit of Low Detector Volume

We have measured the quasiparticle generation-recombination (GR) noise in aluminium lumped element kinetic inductors with a wide range of detector volumes at various temperatures. The basic detector consists of meandering inductor and interdigitated capacitor fingers. The inductor volume is varied from 2 to 153 mu m(3) by changing the inductor width and length to maintain a constant inductance. We started with measuring the power spectrum density (PSD) of the detectors frequency noise which is a function of GR noise and we clearly observed the spectrum roll off at 10 kHz which corresponds to the quasiparticle lifetime. Using data from a temperature sweep of the resonator frequency we convert the frequency fluctuation to quasiparticle fluctuation and observe its strong dependence on detector volume: detectors with smaller volume display less quasiparticle noise amplitude. Meanwhile we observe a saturated quasiparticle density at low temperature from all detectors as the quasiparticle life time tqp approaches a constant value at low temperature.

Li, Juliang↗

CheKiPEUQ Intro 2: Harnessing Uncertainties from Data Sets, Bayesian Design of Experiments in Chemical Kinetics**

When choosing experimental conditions, Bayesian statistical tools can predict the experimental choices which will yield the highest information gain. Experimental choices could be temperature, pressure, reaction time, number of measurements, reactor volume, etc.. Three example analyses are presented here, each using the software Chemical Kinetics Parameter Estimation and Uncertainty Quantification (CheKiPEUQ). Information gain is a measure of reduction of uncertainty in a model's parameters. The three chemical system examples presented each illustrate Bayesian Design of Experiments using information gain. In the first chemical example, temperature selection impacts the information gain for the free energy of reaction in a two-component equilibrium reaction. In the second example, temperature and pressure are explored for a competitive adsorption Langmuir replacement reaction system. Finally, the third example is a catalytic membrane reactor which is a culmination of the previous examples. The catalytic membrane reactor has a complex and nonlinear response in the observables which is solved by numerical evaluation. In the three examples, the experimental conditions are treated as design variables for maximizing information gain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

Atomistic modeling of surface and grain boundary dislocation nucleation in FCC metals

Dislocation nucleation plays a critical role in the plastic deformation of crystalline materials. However, it is challenging to predict the active mode and associated rate of dislocation nucleation under typical experimental loading conditions through molecular dynamics simulation due to timescale limitations. In this report we use the free-end nudged elastic band method to determine the activation energies and activation volumes of dislocation nucleation in four typical face-centered cubic metals of Au, Al, Cu and Ni. We focus on the representative processes of surface and grain boundary dislocation nucleation. The atomistically determined activation volumes of these dislocation nucleation processes are larger than 10b3 (with b being the Burgers vector length) under typical experimental loading conditions. These results are compared with experimentally measured activation volumes in ultrafine-grained and nanocrystalline metals, thereby providing mechanistic insight into their rate-controlling deformation mechanisms.

36 MATERIALS SCIENCE↗

MARCUS Ice Nucleating Particle Measurements (revised 7/2020)

These data list ice nucleating particle (INP) number concentrations active in the immersion freezing mode. Aerosol filters were collected during 4 voyages of the Aurora Australis vessel from 02 November 2017 to 22 March 2018, as part of the Measurements of Aerosols, Radiation and Clouds over the Southern Ocean (MARCUS) study. These voyages transected the Southern Ocean from Hobart, Tasmania to four Australian Antarctic Division stations, including three in Antarctica. Collections were made over alternating periods of 24 and 48 hours using open-faced polycarbonate filters that were approximately 18 m MSL, sited near the AOS trailer and other AMF measurements. The volume of air filtered ranged from 19000 to 38000 standard liters per filter sample. Filters were stored and returned frozen to Colorado State University (CSU), where immersion freezing measurements over a range from 0 to -28 degC were made using the CSU Ice Spectrometer (IS). Collected particles from each filter were resuspended in filtered, deionized water, and then dispensed into the IS and cooled to obtain cumulative INP temperature spectra. Aliquots of suspensions from selected samples were also heat treated (95 degC for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95 degC under UV-B for 20 min to remove all organic carbon INPs, prior to measurement using the IS.

54 ENVIRONMENTAL SCIENCES↗

Comparing and contrasting In-Vial and full-scale systems for sparging volatile analytes

Here, in-vial sparging was demonstrated as an effective, practical alternative to a full-scale sparging system for supporting the analysis of volatile constituents. Using elemental mercury (Hg 0 ) and toluene as representative purgeable analytes, the mass removal for various sparge configurations was measured and a reduced order model was developed and validated. In the primary experiments, Hg 0 in the sparge gas was trapped on activated carbon or gold, thermally desorbed, and quantified using atomic absorption or atomic fluorescence spectroscopy. Toluene experiments using the same in-vial sparge apparatus and sparge parameters were performed to demonstrate the applicability of the reduced order model to a broad range of compounds. Toluene removal was tracked by measuring the remaining toluene in sparged aliquots using Ultraviolet-visible (UV–Vis) spectroscopy. For the sparging, flow rates varied from 25 to 75 mL/min for periods from 0 to 30 min. Sparge performance, mass removal as a function of time, and sparge gas volume were measured for both in-vial and full-scale systems. A model based on dimensionless Henry's Law coefficient, normalized sparge gas volume, and fractional extent of equilibrium matched the experimental data for both compounds and provides a practical tool for future applications. For the conditions tested in this study, the calibrated model indicated that the sparge gas in the in-vial system reached approximately 33% of its equilibrium value before exiting the water surface, while a full-scale system reached approximately 100%. The tests validated the quality, reproducibility, and predictability of sparging performance for both full scale and in-vial sparge systems. Related factors such as waste generation, worker risk, and labor were also assessed. Full scale sparge systems provide the advantage of lower detection levels due to larger sample volume, while the in-vial sparge systems provide advantages for most other factors; including automatability, reducing secondary wastes, lessening the need to clean and check the sparge apparatus, and lowering labor and costs. The data and associated reduced order model support continued development and deployment of in-vial sparge platforms as a practical option for analysis of purgeable analytes such as volatile organic compounds and volatile metals/organometallics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic signal recovery in distribution grids using compressive lossy measurements

Distribution system state estimation requires reliable aggregation of the measured data. However, the large volume of the measured data imposes a significant stress on the underlying communication infrastructure. With the challenges associated with measurement availability, current distribution systems are typically unobservable. To cope with the unobservability issue, compressive sensing theory allows us to recover system state information from a small number of measurements provided the states of the distribution system exhibit sparsity. In this paper, we evaluate the robustness of an updated Kalman filtered modified compressive sensing (KF-ModCS) technique that dynamically estimates the grid states using a small fraction of measured data. In practice, measurements used for sparsity based state estimation may also be intermittent due to communication network induced losses. Further, to understand the effect of packet losses on KF-ModCS, we provide an upper bound for the expected variances of the state estimation error for a given rate of information loss. This upper bound is further improved if the support set of the sparse signal that characterizes the state dynamics does not change over time and/or the reduced model is observable. Simulations based on two practical data sets collected from actual customers in a distribution grid validate the theoretical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bulk modulus measurement at mHz frequencies and high-pressure using synchrotron x-ray radiation

We report an experimental protocol for measuring the frequency dependence of the bulk modulus carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. An oscillating pressure perturbation characterized by x-ray diffraction produces a volume strain measured by imaging. Together, these yield the bulk modulus of the sample. In this work, we report data at 3 mHz as an example of the possibility of providing these data for the frequency range of 1 mHz–100 mHz.

47 OTHER INSTRUMENTATION↗

Results from the Baksan Experiment on Sterile Transitions (BEST)

The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos 𝜈𝑒 observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the “gallium anomaly,” which could be interpreted as evidence for oscillations between 𝜈𝑒 and sterile neutrino (𝜈 𝑠 ) states. A 3.414-MCi 51 Cr 𝜈 𝑒 source was placed at the center of two nested Ga volumes and measurements were made of the production of 71 Ge through the charged current reaction, 71 Ga ⁢(𝜈 𝑒 ,𝑒 − ) ⁢71 Ge, at two average distances. The measured production rates for the inner and the outer targets, respectively, are [54.9$^{+2.5}_{−2.4}$⁢(stat) ± 1.4⁢(syst)] and [55.6$^{+2.7}_{−2.6}$⁢(stat) ± 1.4⁢(syst)] atoms of 71 Ge/𝑑. The ratio (𝑅) of the measured rate of 71 Ge production at each distance to the expected rate from the known cross section and experimental efficiencies are 𝑅 in = 0.79 ± 0.05 and 𝑅 out = 0.77 ± 0.05. The ratio of the outer to the inner result is 0.97 ± 0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20%–24% lower than expected, thus reaffirming the anomaly. Furthermore, these results are consistent with 𝜈 𝑒 → 𝜈 𝑠 oscillations with a relatively large Δ⁢𝑚 2 (>0.5 eV 2 ) and mixing sin 2 ⁡2⁢𝜃 (≈ 0.4).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗