Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Voltammetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Applying Anodic Stripping Voltammetry to Complex Wastewater Streams for Rapid Metal Detection (Final Report)

The overall objective of this project is the development of a lab-on-a-chip (LOC) electrochemical sensor capable of accurately measuring heavy metal (lead (Pb), cadmium (Cd), and arsenic (As)) concentrations in complex aqueous streams such as wastewater. The specific goals include: i) identify how heavy metal speciate and transform during the different stages of the wastewater treatment train, and explore pre-treatment methods that will de-complex heavy metals, making them available to ASV, ii) develop appropriate electrodes for ASV using organic/inorganic nanomaterials, and iii) integrate pre-treatment steps and specialized electrodes into an LOC sensor device capable of autonomously determining heavy metal concentrations in complex wastewater streams.

99 GENERAL AND MISCELLANEOUS↗

Use of cyclic current reversal polarization voltammetry for investigating the relationship between corrosion resistance and heat-treatment induced variations in microstructures of 400 C martensitic stainless steels

Software for running a cyclic current reversal polarization voltammagram has been developed for use with a EG&G Princeton Applied Research Model 273 potentiostat/galvanostat system. The program, which controls the magnitude, direction and duration of an impressed galvanostatic current, will produce data in ASCII spreadsheets (Lotus, Quattro) for graphical representation of CCRPV voltammograms. The program was used to determine differences in corrosion resistance of 440 C martenstic stainless steel produced as a result of changes in microstructure effected by tempering. It was determined that tempering at all temperatures above 400 F resulted in increased polarizability of the material, with the increased likelihood that pitting would be initiated upon exposure to marine environments. These results will be used in development of remedial procedures for lowering the susceptibility of these alloys toward the stress corrosion cracking experienced in bearings used in high pressure oxygen turbopumps used in the main engines of space shuttle orbiters.

Ambrose, John R.↗

An Electrochemical Electrode to Detect Theophylline Based on Copper Oxide Nanoparticles Composited with Graphene Oxide

The electrochemical analysis of theophylline (THP) was investigated by fabricating a carbon paste electrode (CPE) modified with graphene oxide (GO) along with copper oxide (CuO) nanoparticles (CuO-GO/CPE). The impact of electro-kinetic parameters such as the heterogeneous rate constant, the scan rate, the accumulation time, the pH, the transfer coefficient, and the number of electrons and protons transferred into the electro-oxidation mechanism of THP has been studied utilizing electrochemical methods such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The differential pulse voltammetry technique was employed to investigate THP in pharmaceutical and biological samples, confirming the limit of detection (LOD) and quantification (LOQ) of the THP. X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis were performed to characterize the CuO nanoparticles. The CuO-GO/CPE was more sensitive in THP detection because its electrocatalytic characteristics displayed an enhanced peak current in the 0.2 M supporting electrolyte of pH 6.0, proving the excellent sensing functioning of the modified electrode.

36 MATERIALS SCIENCE↗

An electrochemical study of hydrogen in molten 2LiF-BeF 2 (FLiBe) with addition of LiH

The chemical and transport behavior of hydrogen isotopes in molten 2LiF-BeF 2 (FLiBe) is of interest for the design of tritium management systems in nuclear fission and fusion reactors that use FLiBe. The chemical reaction of LiH with FLiBe is used to introduce hydrogen in the molten salt and electrochemical methods are used for in situ studies of hydrogen in FLiBe. LiH reacts with molten FLiBe to generate an electroactive species whose voltammetry peak is proportional to the added quantity of LiH. The cyclic voltammetry reaction potential of 2.009 ± 0.050 V vs Be/Be 2+ and the electron exchange of n = 0.8 ± 0.5 are consistent with the one-electron oxidation of dissolved H in the zero valence state, H o to H + . The concentration of H o is estimated by linear sweep voltammetry at 60–80% of the hydrogen introduced by the reaction of 0.42 mol% LiH with FLiBe and after eleven hours it remains above 40%. It is postulated that covalent BeH 2 is formed in FLiBe upon LiH addition, as a FLiBe-soluble quasi-stable intermediate product. Furthermore, the results provide an evaluation of LiH as a means of introducing dissolved hydrogen in FLiBe, enabling electrochemical methods as tools to advance the understanding of the chemistry of hydrogen isotopes in FLiBe.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HunStat – a simple and low-cost potentiostat for analytical and educational purposes

We have developed a truly low-cost (15 USD), simple do-it-yourself (DIY) potentiostat with compact dimensions. The output potential range of this device is between ±1.65 V. The developed instrument takes advantage of a Seeeduino XIAO microcontroller equipped with 10 bit digital-to-analog (D/A) and 12 bit analog-to-digital (A/D) converters and supports various voltammetry techniques, including cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CA). Interested users are provided with circuit diagrams, bill of materials, and design files. Additionally, software components are also provided free of charge, including an Arduino sketch and control software. The software enables easy manipulation of electrochemical parameters and visualization of results. The presented design introduces a simple and low-cost DIY potentiostat recommended for both analytical and educational purposes.

47 OTHER INSTRUMENTATION↗

Electrochemistry of Redox Active Ferrocene Covalently Attached to Glassy Carbon Electrodes

Formation of well-ordered redox active monolayers is desirable for systematic study of electron transfer for sensor applications and generation of tailored hybrid materials. We have covalently attached 6-bromohexylferrocene (Fc(CH 2 ) 6 Br) to glassy carbon electrodes through a Grignard reaction and used cyclic voltammetry to characterize interfacial electron transfer and probe disorder in these modified electrodes. X-ray photoelectron spectroscopy (XPS) and cyclic voltammetry confirmed attachment of the expected Fe(II) species and reversible electron transfer is observed. However, the full width at half max of the cyclic voltammogram features deviates from the ideal value of 90.6 mV and varies with surface coverage, indicating a disordered surface. As a result, we determine this disorder arises from phase segregation where some domains have a high loading of the hexylferrocene chains while others have a lower loading of hexylferrocene resulting in different local environments that are distinguishable by cyclic voltammetry.

25 ENERGY STORAGE↗

The effects of cations and anions on hydrogen chemisorption at Pt

Experimental evidence based on linear sweep voltammetry is presented to substantiate the view that ionic adsorption substantially shifts electrode potentials in addition to the relative heights of the hydrogen adsorption peaks. HClO4 and HF are chosen as better reference electrolytes for anion studies. The voltammetry curves for 0.1M HF and 0.1M HClO4 as well as the effect of adding successively increasing amounts of H2SO4 to these electrolytes are discussed. The measurements are also extended to alkaline solutions. Mechanisms whereby the addition of various cations and anions to electrolytes such as HF and HClO4 can induce changes in the structure of the hydrogen adsorption region in the voltammetry curves are identified: (1) blocking of sites by anion adsorption and coupling of hydrogen adsorption and anion desorption, (2) modification in the hydrogen adsorption energies for sites adjacent to adsorbed anions, (3) changes in the potential distribution across the interface, and (4) surface restructuring.

Huang, J. C.↗

The Mars Environmental Compatibility Assessment (MECA) Wet Chemistry Experiment on the Mars 2001 Lander

The Mars Environmental Compatibility Assessment (MECA) is an instrument suite that will fly on the Mars Surveyor 2001 Lander Spacecraft. MECA is sponsored by the Human Exploration and Development of Space (HEDS) program and will evaluate potential hazards that the dust and soil of Mars might present to astronauts and their equipment on a future human mission to Mars. Four elements constitute the integrated MECA payload: a microscopy station, patch plates, an electrometer, and the wet chemistry laboratory (WCL). The WCL consists of four identical cells, each of which will evaluate a sample of Martian soil in water to determine conductivity, pH, redox potential, dissolved C02 and 02 levels, and concentrations of many soluble ions including sodium, potassium, magnesium, calcium and the halides. In addition, cyclic voltammetry will be used to evaluate reversible and irreversible oxidants present in the water/soil solution. Anodic stripping voltammetry will be used to measure concentrations of trace metals including lead, copper, and cadmium at ppb levels. Voltammetry is a general electrochemical technique that involves controlling the potential of an electrode while simultaneously measuring the current flowing at that electrode. The WCL experiments will provide information on the corrosivity and reactivity of the Martian soil, as well as on soluble components of the soil which might be toxic to human explorers. They will also guide HEDS scientists in the development of high fidelity Martian soil simulants. In the process of acquiring information relevant to HEDS, the WCL will assess the chemical composition and properties of the salts present in the Martian soil.

Grannan, S. M.↗

A Comparative Study of Redox Mediators for Improved Performance of Li-Oxygen Batteries.

Redox meditators (RMs) are soluble catalysts located in an electrolyte that can improve the energy efficiency (reduced overpotential) and cyclability of Li-oxygen (Li-O-2) batteries. In this work, 20 RMs within a Li-O-2 system with dimethyl sulfoxide and tetraethylene glycol dimethyl ether electrolytes are studied and their electrochemical features such as redox potential, the separation of cathodic and anodic peaks, and their current intensities are measured using cyclic voltammetry (CV) experiments. Six RMs are selected as "primary" choices based on their electrochemical performance, and stability tests are then performed to examine their electrochemical responses after consecutive cycles. Moreover, galvanostatic cycling tests are performed within a Li-O-2 battery system assembled with selected six RMs for real case consistency investigations. It is found that results from CV to galvanostatic cycling tests are consistent for halides and organometallic RMs, where the former exhibit much higher stability. However, the organic RMs show high reversibility in CV but low in battery cycling results. Density functional theory calculations are carried out to gain more understanding of the stability and redox potentials of the RMs. This study provides comparative information to select the most reliable RMs for Li-O-2 batteries along with new fundamental understanding of their electrochemical activity and stability.

cyclic voltammetry↗

Electrochemical measurement and analysis of YCl 3 , ScCl 3 , GdCl 3 and MgCl 2 in molten eutectic LiCl-KCl

For this work, electrochemical measurements of YCl 3 , ScCl 3 , GdCl 3 and MgCl 2 were obtained in molten LiCl-KCl eutectic at 773 K using a three-electrode configuration. Tungsten rods were used as the working and counter electrodes. Two quasi- and one reference electrode(s) (glassy carbon, nickel wire, and Ni/NiO) were used to collect electrochemical measurements of the analyte salts. Cyclic voltammetry data were analyzed to calculate values of diffusion coefficient, exchange current density, and charge transfer resistance and were determined to be on the order of 10 –5 cm 2 s –1 , 10 –2 A cm –2 , and 10 0 Ω; respectively. In general, the values of diffusion coefficients were found to be consistent with those reported of high-temperature molten salts. Relatively large values of exchange current density corresponded with smaller values of charge transfer resistance. These values were found to be reasonable in comparison to results available in the literature. The measured cyclic voltammograms were normalized with respect to both lithium reduction and chloride ion oxidation potentials. Such a normalization technique is effective for comparing experimentally obtained cyclic voltammetry data to those that have been published. An analysis of experimentally obtained results indicates the relation of electrode reactions (e.g., differences of reduction potentials) are independent of the choice of reference electrode. Additionally, the choice of reference electrode did not affect the electrochemical window, exchange current density, or diffusion coefficient values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optical and photophysical properties of platinum benzoporphyrins with C 2v and D 2h symmetry

Platinum(II) mono- and di-benzoporphyrins carrying either ester or imide peripheral groups have been successfully synthesized. These benzoporphyrins possessing C 2v and D 2h symmetry were investigated using a range of techniques including UV-Vis and phosphorescence spectroscopy, differential pulse voltammetry, and transient absorption spectroscopy covering wide spatial and temporal ranges. Up to three oxidation and three reductions within the accessible potential window of dichlorobenzene were observed. Facile reductions for both mono- and dibenzoporphyrin derivatives, more so with imide peripheral substituents were witnessed. Computational studies were supportive of push-pull type interactions within these molecular systems. Here, the formation of triplet excited states within 5 ps after laser excitation was confirmed by femtosecond transient absorption studies. Nanosecond transient absorption studies coupled with phosphorescence lifetime studies revealed relatively rapid relaxation of the triplet excited states as compared to a controlled platinum porphyrin suggesting push-pull type interactions on a slower time scale.

DFT calculations↗

Electrochemical Characterization of Dissolved Oxides in Molten FLiNaK

Molten fluoride salts have long been the subject of investigation given their application in a variety of industrial processes. Oxides are a common exogeneous impurity within these systems, and can lead to many operational and regulatory concerns. In recent studies, the electro-oxidation of dissolved metallic oxides has been attributed to a single step oxygen evolution reaction despite voltametric evidence suggesting otherwise. Here, we first use square wave voltammetry to confirm that the oxidation of dissolved oxides in fluorides proceeds via a two-electron transfer reaction and then demonstrate that the presence of a peroxide-mediated redox reaction better explains the electrochemical data. Numerical simulations were then used to support the determination of improved diffusion coefficients to enable electroanalytical measurements of the oxide concentration across at a variety of temperatures. A linear Arrhenius relationship was observed when the experimental data was corrected for ohmic resistance effects. Concentration measurements using the corrected square wave voltammetry data demonstrated high accuracy across a large range of concentrations, while the uncorrected data showed plateauing and high errors. In total, this work serves to rectify previously misconstrued electrochemical data of oxides in molten salts and demonstrate how accurate, in situ concentration measurements can be achieved in real-world systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Copolymers of vinylferrocene and vinylimidazole for potential sensing applications

Abstract Since imidazole is easily protonated and well known to coordinated to various transition metals, its incorporation into a polymer with ferrocene may result in interesting electronic interactions between the ferrocenyl and imidazolium moieties. To this end, copolymers of vinylferrocene and vinylimidazole were prepared in various ratios by free radical polymerization. The interactions between the ferrocenyl and imidazolium moieties were studied by cyclic voltammetry, UV–Vis spectroscopy and density functional theory (DFT) studies. Cyclic voltammetry of polymer thin films showed multiple oxidation waves at low pH or in the presence of Pb 2+ or Cd 2+ ions. The UV–Vis spectrum of thin films showed an additional absorbance at 625 nm suggesting electronic interactions. In addition, DFT studies indicated that the morphology of the polymer would place some of the ferrocenyl and imidazolium moieties in close proximity.

Polymer Science↗

Increasing Ligand Denticity and Stability for a Water Oxidation Electrocatalyst using P(V) as Connecting Element

Carboxylate complexes have risen to prominence in the field of water oxidation catalysis. Here for the first time we use the higher valence of phosphinates [P(V)] relative to that of carboxylates [C(IV)] to increase ligand denticity. We describe the synthesis and characterization of a new dianionic pentadentate ligand, bcpq 2− that contains a tridentate 2,2’-bipyridine-6-carboxylato moiety, in addition to a 6’-phosphinato substituent that acts as fourth ligand and bears a side arm containing a quinoline, the fifth ligand. The new bcpq ligand allows formation of [Ru(II)(bcpq)(L)] (2 a–b, L=picoline or isoquinoline) and in preliminary results, of a Co(II) complex. NMR spectroscopy, X-ray diffraction, cyclic voltammetry, differential pulse and square wave voltammetry were used to characterize 2 a–b, with 2 b being characterized more extensively as a catalyst. Bulk electrolysis over 15 h at pH 7 was also used, showing that 2 b gave 100±5 % faradaic efficiency and remained completely homogeneous, whereas 1 b was no longer homogeneous; this comparison conclusively shows the advantage of the added denticity in the electrocatalytic context. Replacing carboxylate with P(V) phosphinate with an added arm may be used in other ligand systems to enhance the durability of homogeneous catalysts.

14 SOLAR ENERGY↗