Maritime Fuel Cell Generator Project: 2018 – 2023

This report summarizes activity in the Maritime Fuel Cell (MarFC) Generator Project from 2018 – 2023. FY 2018 saw the implementation of upgrades and repairs, making the unit more reliable and operator friendly. In FY2019 the team engaged the Scripps Institution of Oceanography (SIO) to use the MarFC to provide zero-emission shore power to the research vessel R/V Robert Gordon Sproul while in port at the Nimitz Marine Facility in San Diego, CA. In FY2020, the MarFC unit was shipped to San Diego, CA. A fueling contract with IGX was established to support MarFC operations at SIO, with renewable hydrogen provided by the California State University Los Angeles (CSULA) hydrogen station. The project team (Sandia, Cummins/Hydrogenics) provided training to SIO staff on the technical details of the MarFC, the safe use of hydrogen in general and the MarFC in particular. The first fueling of the unit at the SIO pier was successfully completed by IGX. The first powering of a vessel with fuel-cell shore power was conducted with the R/V Robert Gordon Sproul. While the mechanical systems (lights, AC, ventilation, hydraulics, pumps and cranes) were powered without incident, problems arose when powering the computer systems. Inspections carried out in FY2021 revealed the MarFC needed routine maintenance. Maintenance was performed and the unit was upgraded. The MarFC was turned on after the year pause, and initial test data on power levels and stability were collected. FY2022 was a year spent repairing, upgrading and testing the MarFC unit. Spikes in power and voltage were observed above 60 kW that could potentially extend below 60 kW with time. Such spikes could cause problems with the Sproul electrical systems. These age-related problems, the extended time for the Sproul spent in dry dock for scheduled upgrades, and the associated need to reschedule the vessel’s high-priority science missions made it no longer possible to deploy the unit at SIO. After due consideration, the decision was made by DOE, MARAD and the project team to cease the deployment, remove the MarFC from SIO, and not pursue further deployment activities. On December 2, 2022, the MarFC unit was removed from the Scripps Nimitz Marine Facility and shipped to Fridley, Michigan. The Cummins/Hydrogenics plan for the unit is to assess the condition of the MarFC subcomponents, and then use it as a training/learning system for technical employees new to hydrogen fuel-cell technology. After summarizing project activity from 2018 – 2023, this report provides a review of lessons learned. This report provides next steps in contemplating a follow-on project that would further advance the use of fuel-cell-based shore power in a marine setting. A comparison is made of the project results to the original objectives. This report ends with an accounting of presentations stemming from the project, and a list of references.

08 HYDROGEN↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗

Ligand Substituent Effects on the Electronic Properties of Lindqvist‐Type Polyoxometalate Multi‐Level‐Switches in the Gas Phase, Solution and on Surfaces

Abstract Although the intrinsic electronic properties of polyoxometalates (POMs) can be greatly influenced by modifying them with organic substituents, their resistive switching behavior on surfaces dependent on the organic substituents remains largely unexplored. In this work, we assessed the importance of electron‐withdrawing and electron‐donating ligand substituents on the material properties of a series of hybrid Lindqvist‐type hexavanadates TBA 2 [V 6 O 13 ((OCH 2 ) 3 CCH 2 OH) 2 ] (TBA 2 V 6 ‐OH), TBA 2 [V 6 O 13 ((OCH 2 ) 3 CMe) 2 ] (TBA 2 V 6 ‐Me), TBA 2 [V 6 O 13 ((OCH 2 ) 3 CNHCOCH 2 Cl) 2 ] (TBA 2 V 6 ‐Cl), and TBA 2 [V 6 O 13 ((OCH 2 ) 3 CNHCOCH 2 ‐OOCC 10 H 15 ) 2 ] (TBA 2 V 6 ‐Ad) as potential resistive random‐access memory (ReRAM) components. Compared to their redox behavior in solution, changing the ligand substituents on surfaces results in no significant effect on the potential and, thus, no effect on the resistance steps in the current‐voltage profiles. However, while the current‐voltage characteristics do not change, the peripheral metal‐free substituents in the trisalkoxide framework of Lindqvist‐type hexavanadate molecules influence the adsorption and switching stability of these POMs on gold. This work highlights the noticeable differences between hexavanadate's redox properties in solution (which follow the trend observed in the gas phase) and hexavanadate's resistive switching properties on conducting surfaces. Importantly, their multi‐state switching behavior is not significantly altered by the different type of substituent at the periphery of the trisalkoxo ligands.

36 MATERIALS SCIENCE↗

Evaluating Brightness and Stability of Cathodoluminescence from Colloidal Semiconductor Nanocrystals

Cathodoluminescence offers promise as a technique for correlation of atomic structure with electronic structure at the level of individual nanoparticles or even defects, with the ability to analyze complex nanostructures at length-scales far below those typically available to optical spectroscopy. Unlike other forms of electron microscopy, cathodoluminescence offers direct insights into the electronic structure of the visualized sample. Despite reports more than 10 years ago of individual nanoparticle cathodoluminescence, effective cathodoluminescence collection from colloidal semiconductor materials is relatively rare and remains challenging due to the instability of materials under the conditions of electron beam irradiation. In this work, to clarify the roadblocks for cathodoluminescence analysis of colloidal nanocrystals, we attempt a comprehensive study of the cathodoluminescence properties of semiconductor quantum shells, which have a thin concentric CdSe shell surrounding CdS nanoparticles, then surrounded by a further concentric CdS shell. These same materials were recently demonstrated to show promising scintillation performance in radioluminescence measurements, including high brightness (up to 100 ph/keV) and excellent durability. Comparative quantum yield measurements are designed to assess the brightness of semiconductor nanocrystal films, which show that the quantum shells are much less bright under electron irradiation compared to X-ray photons. Instability of CL emission is assigned to charging effects on the samples—and not thermal effects—through a series of voltage, current, dwell time, and atmospheric pressure experiments.

cathodoluminescence↗

Reliable operation of Cr 2 O 3 :Mg/ $β$-Ga 2 O 3 p–n heterojunction diodes at 600 °C

Beta gallium oxide (β-Ga 2 O 3 )-based semiconductor heterojunctions have recently demonstrated improved performance at high voltages and elevated temperatures and are, thus, promising for applications in power electronic devices and harsh environment sensors. However, the long-term reliability of these ultra-wideband gap (UWBG) semiconductor devices remains barely addressed and may be strongly influenced by chemical reactions at the p–n heterojunction interface. Here, we experimentally demonstrate operation and evaluate the reliability of Cr 2 O 3 :Mg/β-Ga 2 O 3 p–n heterojunction diodes during extended operation at 600 °C, as well as after 30 repeated cycles between 25 and 550 °C. The calculated pO 2 -temperature phase stability diagram of the Ga-Cr-O material system predicts that Ga 2 O 3 and Cr 2 O 3 should remain thermodynamically stable in contact with each other over a wide range of oxygen pressures and operating temperatures. The fabricated Cr 2 O 3 :Mg/β-Ga 2 O 3 p–n heterojunction diodes show room-temperature on/off ratios >104 at ±5 V and a breakdown voltage (V Br ) of -390 V. The leakage current increases with increasing temperature up to 600 °C, which is attributed to Poole–Frenkel emission with a trap barrier height of 0.19 eV. Over the course of a 140-h thermal soak at 600 °C, both the device turn-on voltage and on-state resistance increase from 1.08 V and 5.34 mΩ cm 2 to 1.59 V and 7.1 mΩ cm 2 , respectively. This increase is attributed to the accumulation of Mg and MgO at the Cr 2 O 3 /Ga 2 O 3 interface as observed from the time-of-flight secondary ion mass spectrometry analysis. These findings inform future design strategies of UWBG semiconductor devices for harsh environment operation and underscore the need for further reliability assessments for β-Ga 2 O 3 -based devices.

36 MATERIALS SCIENCE↗

Experimental study of ECH pre-ionization on J-TEXT

An experimental study on electron cyclotron heating (ECH) pre-ionization has been conducted on J-TEXT in support of the joint experiment research for ITER plasma initiation. In this experiment, ECH power was injected to the vessel before the application of loop voltage ionize the neutral gas and form the initial plasma or so-called pre-plasma. The impact of several significant factors, such as magnetic field configuration, pre-fill gas pressure, ECH toroidal injection angle and ECH power on the evolution of pre-plasma are systematically studied, aiming to identify shared features, clarify their potential relationship and optimize the discharge parameters to generate a rather high pre-plasma density. By separating ECH power from the inductive start-up, the effect of pre-plasma on tokamak start-up can be observed. A dynamic magnetic configuration facilitates the transition of pre-plasma to tokamak plasma. To assess the influence of pre-plasma density on tokamak start-up, two kinds of magnetic field configurations are examined. While the effect of different pre-plasma densities on tokamak start-up is negligible, a significant difference is observed between pure ohmic start-up and start-up with pre-ionization. The studies presented here show evolutionary trends and threshold values needed to optimize ECH pre-ionization and also a feasible way to improve pre-plasma density and a configuration to stabilize pre-plasma for transition. Eventually, these results may contribute to multi-machine research and physics analysis that can assist ITER with its optimal preparation for first plasma operation.

ECH↗

Designing Hydropower Flows to Balance Energy and Environmental Needs (HydroWIRES Topic A Final Project Report)

Hydropower is expected to play a new role in the US electricity grid as more variable renewable energy sources like wind and solar come online. Wind and solar generation increase fluctuations in electrical supply increasing the value of flexible generation sources that can quickly ramp generation up and down. The flexible generation hydropower can provide as well as the ancillary services (e.g., frequency and voltage regulation and reserves, black start capability) it provides for balancing and stabilizing the power grid are predicted to be of increased value in these future grid scenarios. Yet, the flexibility of hydropower may come with environmental costs due to up- and down-ramping of hydropower plants (i.e., quickly increasing or decreasing generation flows, respectively) which may strand fish, dewater or scour fish nests, alter habitat, or create unsafe recreational conditions that may be unacceptable to participants in the hydropower regulatory process. These types of environmental impacts are often mitigated through environmental flow requirements that specify minimum or maximum flow releases, or ramp-rates changes allowed at a hydropower facility. While it is not currently known to what degree electrical grid reliability could be affected by environmental flow requirements, gaining a better understanding of these interactions before the grid becomes more deeply decarbonized can help define what policy, regulation, or infrastructure may be needed to support the clean energy transition. As the future grid will rely on hydropower to provide both flexibility and robust environmental protections, the analyses and tools described in this report are centered on making mechanistic linkages between energy and the environment in hydropower systems. This understanding of energy-environment linkages can provide the foundational understanding needed to quantitatively assess the trade-offs between the increased generation flexibility that hydropower will be expected to provide and the environmental impacts of this flexibility. This report seeks to provide an objective foundation for building future science and tools that can be used by a broad spectrum of the hydropower community that is involved in licensing or environmental regulatory proceedings tasked with balancing energy and environmental objectives through flow management.

13 HYDRO ENERGY↗

Thermal Assessment of Swift BAT Instrument Thermal Control System in Flight

THE BAT is the primary instrument on the Swift spacecraft. The Swift mission is part of the National Aeronautics and Space Administration (NASA) Medium-Size Explorer (MIDEX) Program, and is managed by Goddard Space Flight Center (GSFC). It is designed to detect gamma ray burst over a broad region of the sky in a low Earth orbit of 600-km altitude and quickly align the telescopes on the spacecraft to the gamma ray source. It was successfully launched into orbit on November 20, 2004. The Swift mission is a first of its kind of multi-wavelength transient observatory for gamma ray burst astronomy. Its mission life is 2 years. The inclination is 22 deg maximum. The spacecraft bus voltage to the instruments is in the 24 V to 35 V range. The instruments will be turned off when the voltage is below 27 V. The BAT is mounted to the optical bench through five titanium flexures. The BAT has been developed at GSFC. Its telescope assembly consists of 256 Detector Modules (DMs) in the Detector Array. There are 16 Detector Array Blocks. Each Block holds 16 DMs, 3 Block Voltage Regulator (BVR) units and 3 Block Command & Data Handling (BCDH) units. The power dissipation of each Block has been measured to be 13 W. Therefore the total power dissipation of the 16 Blocks is 208 W. The DAP is 1.3 m (4.3 ft) x 1 m (3.3 ft), accommodates all the 16 Blocks. It also provides the mounting surface and the positional stability for the Blocks. The DMs are located at the top (+X side) of the DAP and is enclosed by graded-Z shields on the sides and a coded mask at the top. The BVRs and BCDHs are located at the bottom (-X side) of the DAP. Eight Blocks are located at the front (-Z side or radiator side) of the DAP, and eight are located at the rear (+Z side) of the DAP. The DMs and top of DAP are insulated with a 7-layer multi-layer insulation (MLI). There is a 5.08 cm (2 in) x 5.08 cm (2 in) MLI cutout over each Block heater controller so that heat radiates from the heater controller to the mask. The exterior of the mask, graded-Z shields and bottom of DAP is insulated with a 15-layer MLI.

Choi, Michael K.↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Electro-Thermal Simulation Studies of SiC Junction Diodes Containing Screw Dislocations Under High Reverse-Bias Operation

The objective of this work was to conduct a modeling study of SiC P-N junction diodes operating under high reverse biased conditions. Analytical models and numerical simulation capabilities were to be developed for self-consistent electro-thermal analysis of the diode current-voltage (I-V) characteristics. Data from GRC indicate that screw dislocations are unavoidable in large area SiC devices, and lead to changes in the SiC diode electrical response characteristics under high field conditions. For example, device instability and failures linked to internal current filamentation have been observed. The physical origin of these processes is not well understood, and quantitative projections of the electrical behavior under high field and temperature conditions are lacking. Thermal calculations for SiC devices have not been reported in the literature either. So estimates or projections of peak device temperatures and power limitations do not exist. This numerical study and simulation analysis was aimed at resolving some of the above issues. The following tasks were successfully accomplished: (1) Development of physically based models using one- and two-dimensional drift-diffusion theory for the transport behavior and I-V characteristics; (2) One- and two-dimensional heat flow to account for internal device heating. This led to calculations of the internal temperature profiles, which in turn, were used to update the electrical transport parameters for a self-consistent analysis. The temperature profiles and the peak values were thus obtainable for a given device operating condition; (3) Inclusion of traps assumed to model the presence of internal screw dislocations running along the longitudinal direction; (4) Predictions of the operating characteristics with and without heating as a function of applied bias with and without traps. Both one and two-dimensional cases were implemented; (5) Assessment of device stability based on the operating characteristics. The presence of internal non-uniformities, particularly filamentary structures, was probed and demonstrated; (6) Cause and physical origins of filamentary behavior and unstable I-V characteristics were made transparent; (7) It was demonstrated that diodes containing defects would be more prone to thermal breakdown associated with the temperature dependent decrease in the thermal conductivity; and (8) Finally, negative differential resistance (S-shaped NDR) which can potential lead to device instability and filamentary behavior was shown to occur for diodes containing a line of defects such as could be associated with a screw dislocation line.

Joshi, R. P.↗

Feasibility Analyses for the Microgrid of the Mountain in the Cordillera Central Region of Puerto Rico

Distributed energy resource (DER) development can benefit communities through improvement of access to reliable electricity and a resilient energy system. Many place-specific considerations must be accounted for when designing electrical systems with co-located generation and loads. This paper presents an overview of four studies focusing on different aspects for regional DER development in the Cordillera Central region of Puerto Rico, including a grid and load stability study with the introduction of solar energy generation, microgrid design based on the solar resource in the area, resilience considerations during power outage scenarios, and qualitative risk aspects for components in the microgrid. Additionally, a conceptual substation microgrid analysis is conducted using the Microgrid Design Toolkit (MDT) to evaluate trade-offs between cost and energy availability, providing insights into optimal design strategies. A microgrid resilience assessment is performed using the Resilient Nodal Cluster Analysis Tool (ReNCAT) to identify critical loads and evaluates their accessibility during outages, emphasizing the importance of community needs. Finally, a qualitative risk assessment utilizing Hazard and Operability Analysis (HAZOP) methods highlights potential hazards and mitigations for microgrid components, ensuring robust system design and operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

black start↗

Demonstration of Grid Services Using Mixed Grid-Forming and Grid-Following Technologies at the Wheatridge Renewable Energy Facility (Final Technical Report)

This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.

14 SOLAR ENERGY↗

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Reliability and Safety Assessment of Urban Air Mobility Concept Vehicles

The following work was commissioned by the National Aeronautics and Space Administration (NASA) to guide industry and future regulation related to urban air mobility (UAM). Prior studies compared the relative safety of NASA concept vehicles, Figure ES1, designed for UAM and provided recommendations for industry research, aircraft architectural improvements, and regulatory updates. After the prior study completed, the European Aviation Safety Agency (EASA) released regulatory guidance in the form of a special condition (SC), SC-VTOL-01, for multirotors with distributed propulsion and flight controls (DPFC). The objective of the current work was to develop DPFC architectures that will comply with SC-VTOL-01. Vehicle designs, DPFC architectures, and stability & control (S&C) models were developed to find limitations and trends to guide industry. To guide this task, NASA developed quad, hex, and an octorotor to better define vehicle attributes and trade space. Aircraft for study included electric, hybrid-electric, and turboshaft powerplants and collective and RPM control schemes. Assessments are in terms of the safety level achieved, and/or aircraft component/features needed to meet SC-VTOL-01. The most challenging criteria being the catastrophic failure rate, ≤10-9 catastrophic failures per flight hour, and that no single failures may result in a catastrophic event. A disciplined process was followed, similar to that in Aerospace Recommended Practice (ARP) 4761. A preliminary system safety assessment (PSSA) leveraged prior work as a basis of creating failure rate budgets for system design teams. System designs were updated and iterated upon, working with reliability and safety subject matter experts to develop SC-VTOL-01 compliant designs. Design changes were reflected in updated PSSAs for initial verification of compliance. The DPFC architecture was broken into four system design teams, the (1) flight control system (FCS), (2) drive and power system, (3) thermal management system (TMS), and (4) electrical power and distribution system. The FCS including elements necessary to control the aircraft, drive and power including elements necessary to generate and transmit shaft power, the TMS including elements necessary to maintain temperature limits in all operating environments, and electrical pow-er and distribution including equipment necessary to store and transmit electrical energy. Results found that all aircraft evaluated may have paths to comply with SC-VTOL-01, Figure ES2. However, S&C models showed large power transients that must be addressed and PSSA results show that future work is needed in single load path structures, high voltage power storage and distribution, and in motor/rotor overspeed protection.

Boeing↗

Selecting the Optimal Fluorinated Ether Co-Solvent for Lithium Metal Batteries

To guide the selection of a suitable fluorinated ether (FE) co -solvent for lithium metal batteries, it is crucial to understand the relationship between the organic structures of the FEs and the electrochemical performance of an FE-containing electrolyte. In this work, 1,1,2,2-tetrafluoro-1-(2,2,2-trifluoroethoxy)ethane (FEE), 1,1,2,2-tetrafluoro-3-(1,1,2,2-tetrafluoroethoxy)-propane (TTE), and 1,2-bis(1,1,2,2-tetrafluoroethoxy)ethane (OFDEE) were chosen as representative FE co-solvents because of their distinct structural properties. The structure-activity relationship between the FEs and the electrochemical performance of Li||LiNi 0.6 Mn 0.2 Co 0.2 O 2 (Li||NMC622) cells was correlated and quantified by Fourier-transform infrared and multi-dimensional nuclear magnetic resonance techniques. Sand's model was also employed to assess the extent of lithium dendrite formation in the cells using various FE electrolytes. The cycling performance of Li||NMC622 cells using different FE co-solvents follows the order FEE > TTE > OFDEE. Further, since the direct measurement of Sand's time is difficult, we introduced relative Sand's time to probe the diffusion behavior of each electrolyte, and the results showed that the best performance was obtained in the electrolyte with the longest relative Sand's time. Moreover, the lithium metal cell using the electrolyte with FEE co-solvent showed similar capacity retention compared with the baseline electrolyte at room temperature, but it demonstrated significantly improved low-temperature performance. The results indicate that FEE is a promising co-solvent candidate for improving the low-temperature performance of lithium metal batteries because it possesses not only non-solvating behavior but also very low viscosity and non-flammability. The advanced electrolyte LiPF 6 -FEC-DMC-FEE enables very stable cycling of lithium metal batteries at various temperatures.

25 ENERGY STORAGE↗