Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Virtual temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Polar Heat Flow on Io

Recently, Galileo spacecraft data have revealed Io's polar regions to be much warmer than previously expected. This unexpected development came from Photo-Polarimeter Radiometer (PPR) data which show that the minimum night temperatures are in the range of 90-95 K virtually everywhere on Io. The minimum night temperatures show no dependence upon latitude and, when away from the sunset terminator, they show no dependence upon time of night. This is indeed bizarre behavior for surface units which generally had been assumed to be passive with respect to Io's pervasive volcanism. Night temperatures of 90-95 K at high, polar latitudes are particularly hard to explain. Even assuming infinite thermal inertia, at these latitudes there is insufficient sunlight to support these warm night temperatures. Thus, through the process of elimination of other possibilities, we come to the conclusion that these surfaces are volcanically heated. Taking previously passive units and turning them into new sources of heat flow is a radical departure from previous thermophysical model paradigms. However, the geological interpretation is straight forward. We are simply seeing the effect of old, cool lava flows which cover most of the surface of Io but yet have some heat to radiate. Under these new constraints, we have taken on the challenge of formulating a physical model which quantitatively reproduces all of the observations of Io's thermal emission. In the following we introduce a new parametric model which suffices to identify a previously unrecognized polar component of Io's heat flow.

Veeder, G. J.↗

Two Color Interferometry with Nonlinear Refractive Properties

Using nonlinear refractive properties of salt-water solution at two wavelengths, numerical analysis has been performed to extract temperature and concentration from virtual interferometric fringe data. The theoretical study, using a commercially available equation solving tool, starts with critical fringe counting needs and the role of nonlinear refractive properties in such measurements. Finally, methodology of the analysis, developed codes, and fringe counting accuracy needs are described in detail.

Vikram, Chandra S.↗

High-temperature thermal storage systems for advanced solar receivers materials selections

Advanced space power systems that use solar energy and Brayton or Stirling heat engines require thermal energy storage (TES) systems to operate continuously through periods of shade. The receiver storage units, key elements in both Brayton and Stirling systems, are designed to use the latent heat of fusion of phase-change materials (PCMs). The power systems under current consideration for near-future National Aeronautics and Space Administration space missions require working fluid temperatures in the 1100 to 1400 K range. The PCMs under current investigation that gave liquid temperatures within this range are the fluoride family of salts. However, these salts have low thermal conductivity, which causes large temperature gradients in the storage systems. Improvements can be obtained, however, with the use of thermal conductivity enhancements or metallic PCMs. In fact, if suitable containment materials can be found, the use of metallic PCMs would virtually eliminate the orbit associated temperature variations in TES systems. The high thermal conductivity and generally low volume change on melting of germanium and alloys based on silicon make them attractive for storage of thermal energy in space power systems. An approach to solving the containment problem, involving both chemical and physical compatibility, preparation of NiSi/NiSi2, and initial results for containment of germanium and NiSi/NiSi2, are presented.

Wilson, D. F.↗

Preliminary results from screening tests of commercial catalysts with potential use in gas turbine combustors. Part 2: Combustion test rig evaluation

Several commercial monolithic catalysts were tested in a combustion test rig to determine their suitability for use in a gas turbine combuster primary zone. The catalyst test bed consisted of two to four elements of 12-centimeter diameter by 2.5-centimeter long monolith. Results are presented of the measured combustion efficiency and catalyst bed temperature history for an inlet propane-air mixture temperature of 800 K, a pressure of 300,000 newtons per square meter, inlet velocities of 10 to 25 meters per second and equivalence ratios of 0.1 to 0.3. The best catalysts tested gave combustion efficiencies of virtually 100 percent for reaction temperatures ranging from 1,325 K at 10 meters per second to 1,400 K at 25 meters per second. This performance was only possible with fresh catalysts. The catalysts tested were not specifically developed for use at these conditions and showed some loss in activity after about 3 hours' testing.

Anderson, D. N.↗

Development of a static feed water electrolysis system

A one person level oxygen generation subsystem was developed and production of the one person oxygen metabolic requirements, 0.82 kg, per day was demonstrated without the need for condenser/separators or electrolyte pumps. During 650 hours of shakedown, design verification, and endurance testing, cell voltages averaged 1.62 V at 206 mA/sq cm and at average operating temperature as low as 326 K, virtually corresponding to the state of the art performance previously established for single cells. This high efficiency and low waste heat generation prevented maintenance of the 339 K design temperature without supplemental heating. Improved water electrolysis cell frames were designed, new injection molds were fabricated, and a series of frames was molded. A modified three fluid pressure controller was developed and a static feed water electrolysis that requires no electrolyte in the static feed compartment was developed and successfully evaluated.

Schubert, F. H.↗

Experimental clean combustor program: Diesel no. 2 fuel addendum, phase 3

A CF6-50 engine equipped with an advanced, low emission, double annular combustor was operated 4.8 hours with No. 2 diesel fuel. Fourteen steady-state operating conditions ranging from idle to full power were investigated. Engine/combustor performance and exhaust emissions were obtained and compared to JF-5 fueled test results. With one exception, fuel effects were very small and in agreement with previously obtained combustor test rig results. At high power operating condition, the two fuels produced virtually the same peak metal temperatures and exhaust emission levels. At low power operating conditions, where only the pilot stage was fueled, smoke levels tended to be significantly higher with No. 2 diesel fuel. Additional development of this combustor concept is needed in the areas of exit temperature distribution, engine fuel control, and exhaust emission levels before it can be considered for production engine use.

Gleason, C. C.↗

Trajectory Control for Vehicles Entering the Earth's Atmosphere at Small Flight Path Angles

Methods of controlling the trajectories of high-drag-low-lift vehicles entering the earth's atmosphere at angles of attack near 90 deg and at initial entry angles up to 3 deg are studied. The trajectories are calculated for vehicles whose angle of attack can be held constant at some specified value or can be perfectly controlled as a function of some measured quantity along the trajectory. The results might be applied in the design of automatic control systems or in the design of instruments which will give the human pilot sufficient information to control his trajectory properly during an atmospheric entry. Trajectory data are compared on the basis of the deceleration, range, angle of attack, and, in some cases, the rate of descent. The aerodynamic heat-transfer rate and skin temperature of a vehicle with a simple heat-sink type of structure are calculated for trajectories made with several types of control functions. For the range of entry angles considered, it is found that the angle of attack can be controlled to restrict the deceleration down to an arbitrarily chosen level of 3g. All the control functions tried are successful in reducing the maximum deceleration to the desired level. However, in order to avoid a tendency for the deceleration to reach an initial peak decrease, and then reach a second peak, some anticipation is required in the control function so that the change in angle of attack will lead the change in deceleration. When the angle of attack is controlled in the aforementioned manner, the maximum rate of aerodynamic heat transfer to the skin is reduced, the maximum skin temperature of the vehicle is virtually unaffected, and the total heat absorbed is slightly increased. The increase in total heat can be minimized, however, by maintaining the maximum desired deceleration for as much of the trajectory as possible. From an initial angle of attack of 90 deg, the angle-of-attack requirements necessary to maintain constant values of deceleration (1g to 4g) and constant values of rate of descent (450 to 1,130 ft/sec) as long as it is aerodynamically practical are calculated and are found to be moderate in both magnitude and rate. Entry trajectories made with these types of control are presented and discussed.

Eggleston, John M.↗

The effect of thermal exposure on the mechanical properties of aluminum-graphite composites

The mechanical properties of aluminum-graphite composites were measured at room temperature in the as-received condition, after elevated temperature exposure and after thermal cycling. The composites were fabricated by solid-state diffusion bonding of liquid-phase Al-infiltrated Thornel 50 fibers. The results showed that the maximum longitudinal tensile strength of the as-received material was 80,000 psi, which corresponds well with the rule of mixture value. The composite strength was observed to vary widely, depending on the extent of wetting of the fibers by the aluminum. The strength of the composites in the transverse direction was generally very low, due to poor interfacial bonding. Aluminum carbide (Al4C3) formed at the surface of the fibers at temperatures greater than 500 C. Development of the carbide was shown to be diffusion-controlled and was dependent on the time and temperature used. It was shown that the tensile strength was virtually unaffected by heat-treatment up to 500 C; beyond that temperature a drastic degradation of tensile strength occurred. Thermal cycling of the composites below 500 C resulted in an observable degradation of the composite strength.

Khan, I. H.↗

Preliminary analysis of hot spot factors in an advanced reactor for space electric power systems

The maximum fuel pin temperature for nominal operation in an advanced power reactor is 1370 K. Because of possible nitrogen embrittlement of the clad, the fuel temperature was limited to 1622 K. Assuming simultaneous occurrence of the most adverse conditions a deterministic analysis gave a maximum fuel temperature of 1610 K. A statistical analysis, using a synthesized estimate of the standard deviation for the highest fuel pin temperature, showed probabilities of 0.015 of that pin exceeding the temperature limit by the distribution free Chebyshev inequality and virtually nil assuming a normal distribution. The latter assumption gives a 1463 K maximum temperature at 3 standard deviations, the usually assumed cutoff. Further, the distribution and standard deviation of the fuel-clad gap are the most significant contributions to the uncertainty in the fuel temperature.

Lustig, P. H.↗

Infrared Thermometer

Diatek Corporation, San Diego, CA and the Jet Propulsion Lab developed the Diatek Model 7000 aural thermometer which weighs only eight ounces, and measures temperature in less than two seconds using infrared astronomy technology to measure the amount of infrared energy emitted by the eardrum (the same way temperature of stars and planets is measured). This method avoids contact with mucous membranes, virtually eliminating the possibility of cross infection, and permits temperature measurement of newborn, critically ill, or incapacitated patients. Diatek Corporation was purchased by Welch Allyn Inc. The Diatek Model 7000 is now marketed as SureTemp.

Source record↗

Calibration, Data Acquisition, and Post Analysis of Turbulent Fluid Flow in a Calibration Jet Using Hot-wire Anemometry

The Turbine Branch concentrates on the following areas: Computational Fluid Dynamics (CFD), and implementing experimental procedures to obtain physical modeling data. Hot-wire Anemometry is a valuable tool for obtaining physical modeling data. Hot-wire Anemometry is likely to remain the principal research tool for most turbulent air/gas flow studies. The Hot-wire anemometer consists of a fine wire heated by electric current. When placed in a fluid stream, the hot-wire loses heat to the fluid by forced convection. In forced convection, energy transfer is due to molecular motion imposed by an extraneous force moving fluid parcels. When the hot-wire is in "equilibrium", the rate of heat input to the wire is equal to the rate of heat loss at the wire ends. The equality between heat input and heat loss is the basis for King s equation, which relates the electrical parameters of the hot-wire to the flow parameters of the fluid. Hot-wire anemometry is based on convective heat transfer from a heated wire element placed in a fluid flow. Any change in the fluid flow condition that affects the heat transfer from the heated element will be detected virtually instantaneously by a constant-temperature Hot-wire anemometry system. The system implemented for this research is the IFA 300. The system is a fully-integrated, thermal anemometer-based system that measures mean and fluctuating velocity components in air, water, and other fluids. It also measures turbulence and makes localized temperature measurements. A constant-temperature anemometer is a bridge and amplifier circuit that controls a tiny wire at constant temperature. As a fluid flow passes over the heated sensor, the amplifier senses the bridge off-balance and adjusts the voltage to the top of the bridge, keeping the bridge in balance. The voltage on top of the bridge can then be related to the velocity of the flow. The bridge voltage is sensitive to temperature as well as velocity and so the built-in thermocouple circuit can be attached to a thermocouple that can measure the fluid temperature. Additional information is included in the original extended abstract.

Moreno, Michelle↗

Testing of Cloud Microphysics Scheme with Snow Events

One of the grand challenges of the Global Precipitation Measurement (GPM) mission is to improve precipitation measurements in mid- and high-latitudes during cold seasons through the use of high-frequency passive microwave radiometry. For this, the Weather Research Forecast (WRF) model with the Goddard microphysics scheme is coupled with the Satellite Data Simulation Unit (WRF-SDSU) that has been developed to facilitate the over-snowfall retrieval algorithm by providing virtual cloud library and microwave brightness temperature (To) measurements consistent to the GPM Microwave Imager (GMI). This study tested the Goddard cloud microphysics scheme in WRF in snowstorm events (January 20-22, 2007) over the Canadian CloudSat/CALIPSO Validation Project (C3VP) site up in Ontario, Canada. In this meeting, we will present the performance of the Goddard cloud microphysics scheme both with 2ice (ice and snow) and 3ice (ice, snow and graupel) as well as other WRF microphysics schemes. Results will be compared with the King Radar data. We will also use the WRF model outputs to drive the Goddard SDSU to calculate radiances and backscattering signals consistent to satellite direct observations. These simulated radiance are evaluated against the measurement from A-Train satellites.

Tao, Wei-Kuo↗

The 20-22 January 2007 Snow Events over Canada: Microphysical Properties

One of the grand challenges of the Global Precipitation Measurement (GPM) mission is to improve precipitation measurements in mid- and high-latitudes during cold seasons through the use of high-frequency passive microwave radiometry. Toward this end, the Weather Research and Forecasting (WRF) model with the Goddard microphysics scheme is coupled with a Satellite Data Simulation Unit (WRF-SDSU) that has been developed to facilitate over-land snowfall retrieval algorithms by providing a virtual cloud library and microwave brightness temperature (Tb) measurements consistent with the GPM Microwave Imager (GMI). This study tested the Goddard cloud microphysics scheme in WRF for snowstorm events (January 20-22, 2007) that took place over the Canadian CloudSAT/CALIPSO Validation Project (C3VP) ground site (Centre for Atmospheric Research Experiments - CARE) in Ontario, Canada. In this paper, the performance of the Goddard cloud microphysics scheme both with 2ice (ice and snow) and 3ice (ice, snow and graupel) as well as other WRF microphysics schemes will be presented. The results are compared with data from the Environment Canada (EC) King Radar, an operational C-band radar located near the CARE site. In addition, the WRF model output is used to drive the Goddard SDSU to calculate radiances and backscattering signals consistent with direct satellite observations for evaluating the model results.

Tao. W.K.↗

WRF Simulations of the 20-22 January 2007 Snow Events over Eastern Canada: Comparison with In-Situ and Satellite Observations

One of the grand challenges of the Global Precipitation Measurement (GPM) mission is to improve cold season precipitation measurements in middle and high latitudes through the use of high-frequency passive microwave radiometry. For this, the Weather Research and Forecasting (WRF) model with the Goddard microphysics scheme is coupled with a satellite data simulation unit (WRF-SDSU) that has been developed to facilitate over-land snowfall retrieval algorithms by providing a virtual cloud library and microwave brightness temperature (Tb) measurements consistent with the GPM Microwave Imager (GMI). This study tested the Goddard cloud microphysics scheme in WRF for two snowstorm events, a lake effect and a synoptic event, that occurred between 20 and 22 January 2007 over the Canadian CloudSAT/CALIPSO Validation Project (C3VP) site in Ontario, Canada. The 24h-accumulated snowfall predicted by the WRF model with the Goddard microphysics was comparable to the observed accumulated snowfall by the ground-based radar for both events. The model correctly predicted the onset and ending of both snow events at the CARE site. WRF simulations capture the basic cloud properties as seen by the ground-based radar and satellite (i.e., CloudSAT, AMSU-B) observations as well as the observed cloud streak organization in the lake event. This latter result reveals that WRF was able to capture the cloud macro-structure reasonably well.

Shi, J. J.↗

Alternatives to ozone depleting refrigerants in test equipment

This paper describes the initial results of a refrigerant retrofit project at the Aerospace Guidance and Metrology Center (AGMC) at Newark Air Force Base, Ohio. The objective is to convert selected types of test equipment to properly operate on hydrofluorocarbon (HFC) alternative refrigerants, having no ozone depleting potential, without compromising system reliability or durability. This paper discusses the primary technical issues and summarizes the test results for 17 different types of test equipment: ten environmental chambers, two ultralow temperature freezers, two coolant recirculators, one temperature control unit, one vapor degreaser, and one refrigerant recovery system. The postconversion performance test results have been very encouraging: system capacity and input power remained virtually unchanged. In some cases, the minimum operating temperature increased by a few degrees as a result of the conversion, but never beyond AGMC's functional requirements.

Hall, Richard L.↗

Color and temperature signatures of ocean fronts observed with the Nimbus-7 CZCS

The Nimbus-7 Coastal Zone Color Scanner has a unique capability for imaging simultaneously the optical (ocean color) and surface temperature (thermal infrared) signatures of ocean fronts. Examples of such color and temperature visualizations of some ocean fronts delineate virtually identical morphology. In other cases, however, the two signatures are displaced horizontally by tens of km, and display markedly different morphology and fine structure. For example, an image of the Gulf Stream's north wall over the Grand Banks shows the sharpest color front to occur approximately 50 km away from the sharpest temperature front. Moreover, the fine structure of the color front is qualitatively suggestive of disorganized turbulent diffusion, whereas that of the thermal front shows distinctive shear instabilities. These differences can occur because the infrared temperature image represents the top 0.05 millimeter of the sea surface, whereas the ocean color image represents the upper meters to decameters of the sea.

Mueller, J. L.↗

Development and Application of a Tool for Optimizing Composite Matrix Viscoplastic Material Parameters

This document describes a recently developed analysis tool that enhances the resident capabilities of the Micromechanics Analysis Code with the Generalized Method of Cells (MAC/GMC) and its application. MAC/GMC is a composite material and laminate analysis software package developed at NASA Glenn Research Center. The primary focus of the current effort is to provide a graphical user interface (GUI) capability that helps users optimize highly nonlinear viscoplastic constitutive law parameters by fitting experimentally observed/measured stress-strain responses under various thermo-mechanical conditions for braided composites. The tool has been developed utilizing the MATrix LABoratory (MATLAB) (The Mathworks, Inc., Natick, MA) programming language. Illustrative examples shown are for a specific braided composite system wherein the matrix viscoplastic behavior is represented by a constitutive law described by seven parameters. The tool is general enough to fit any number of experimentally observed stress-strain responses of the material. The number of parameters to be optimized, as well as the importance given to each stress-strain response, are user choice. Three different optimization algorithms are included: (1) Optimization based on gradient method, (2) Genetic algorithm (GA) based optimization and (3) Particle Swarm Optimization (PSO). The user can mix and match the three algorithms. For example, one can start optimization with either 2 or 3 and then use the optimized solution to further fine tune with approach 1. The secondary focus of this paper is to demonstrate the application of this tool to optimize/calibrate parameters for a nonlinear viscoplastic matrix to predict stress-strain curves (for constituent and composite levels) at different rates, temperatures and/or loading conditions utilizing the Generalized Method of Cells. After preliminary validation of the tool through comparison with experimental results, a detailed virtual parametric study is presented wherein the combined effects of temperature and loading rate on the predicted response of a braided composite is investigated.

thermo-mechanical; MATLAB; GUI-Based Too↗

Analytical prediction of aerothermal environment in a wing-elevon cove

The fluid/thermal environment in the cove between the wing and elevon surfaces was a concern throughout the design and initial operational phases of the space shuttle. Experimenal and analytical investigations provided some understanding of the environmental in the wing-elevon cove. An incompressible finite element analysis of flow through straight parallel walls and curved parallel walls to determine the effects of cove geomtry on the fluid/thermal environment is described. Results from this analysis agree qualitatively with experimental data. The centerline gas temperatures and cold wall heating rates are virtually identical for the two cases indicating that the slight curvature has little effect on the overall thermal environment.

Bey, K. S.↗