Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Virtual models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

Calibration of a Neutron Hydroprobe for Moisture Measurements in Small-Diameter Steel-Cased Boreholes

Computation of soil moisture content from thermalized neutron counts for the T-Farm Interim cover requires a calibration relationship but none exists for 2-in tubes. A number of calibration options are available for the neutron probe, including vendor calibration, field calibration, but none of these methods were deemed appropriate for the configuration of interest. The objective of this work was to develop a calibration relation for converting neutron counts measured in 2-in access tubes to soil water content. The calibration method chosen for this study was a computational approach using the Monte Carlo N-Particle Transport Code (MCNP). Model calibration was performed using field measurements in the Hanford calibration models with 6-in access tubes, in air and in the probe shield. The bet-fit model relating known water content to measured neutron counts was an exponential model that was essentially equivalent to that currently being used for 6-in steel cased wells. The MCNP simulations successfully predicted the neutron count rate for the neutron shield and the three calibration models for which data were collected in the field. However, predictions for air were about 65% lower than the measured counts . This discrepancy can be attributed to uncertainties in the configuration used for the air measurements. MCNP-simulated counts for the physical models were essentially equal to the measured counts with values. Accurate prediction of the response in 6-in casings in the three calibration models was motivation to predict the response in 2-in access tubes. Simulations were performed for six of the seven calibration models as well as 4 virtual models with the entire set covering a moisture range of 0 to 40%. Predicted counts for the calibration models with 2-in access tubes were 40 to 50% higher than in the 6-inch tubes. Predicted counts for water were about 60% higher in the 2-in tube than in the 6-in tube. The discrepancy between the 2-in and 6-in tube can be attributed to the smaller air gap between the probe and the 2-in access tube. The best-fit model relating volumetric water content to count ratio (CR) is of the form e^A x CR^B with A=0.3596 ± 0.0216 and B=0.4629 ± 0.0629 and r^2= 0.9998. It is recommended that the calibration function based on the count ratio, rather than raw counts, be used to avoid the effects of electronic noise in the probe that may arise due to the conditions at the time of measurement. These results suggest that the MCNP code can be used to extend calibrations for the neutron probe to different conditions including access tube size as well as composition without the need to construct additional physical models.

36 MATERIALS SCIENCE↗

Investigation of assumptions and approximations in the virtual fields method for a viscoplastic material model

The Virtual Fields Method (VFM) is an inverse technique used for parameter estimation and calibration of constitutive models. Many assumptions and approximations—such as plane stress, incompressible plasticity, and spatial and temporal derivative calculations—are required to use VFM with full-field deformation data, for example, from Digital Image Correlation (DIC). Here, this work presents a comprehensive discussion of the effects of these assumptions and approximations on parameters identified by VFM for a viscoplastic material model for 304L stainless steel. We generated synthetic data from a Finite-Element Analysis (FEA) in order to have a reference solution with a known material model and known model parameters, and we investigated four cases in which successively more assumptions and approximations were included in the data. We found that VFM is tolerant to small deviations from the plane stress condition in a small region of the sample, and that the incompressible plasticity assumption can be used to estimate thickness changes with little error. A local polynomial fit to the displacement data was successfully employed to compute the spatial displacement gradients. The choice of temporal derivative approximation (i.e., backwards difference versus central difference) was found to have a significant influence on the computed rate of deformation and on the VFM results for the rate-dependent model used in this work. Finally, the noise introduced into the displacement data from a stereo-DIC simulator was found to have negligible influence on the VFM results. Evaluating the effects of assumptions and approximations using synthetic data is a critical first step for verifying and validating VFM for specific applications. Finally, the results of this work provide the foundation for confidently using VFM for experimental data.

304L stainless steel↗

NVBL (National Virtual Biotechnology Laboratory): Pandemic Monitoring and Modeling

This virtual symposium was held to highlight the impact the U.S. Department of Energy’s (DOE) National Virtual Biotechnology Laboratory (NVBL) has had utilizing the unique capabilities of the DOE to tackle the science and technology challenges associated with COVID-19, and to discuss areas in which the NVBL can have impact in the future. With perspectives from Chris Fall, Director, Office of Science, DOE, and William A. Bookless, Principal Deputy Administrator of the National Nuclear Security Administration, the event featured Presentations from lead investigators reporting progress in: Epidemiological modeling, Therapeutics, Testing, Understanding transport of the virus, and Solving issues around supply chain challenges. In addition, keynote speakers from outside the NVBL discussed the upcoming science and technology needs in computing, testing and surveillance, and vaccines. The event was aimed at the S&T community, media, and general public.

Bhaduri, Budhu↗

Multiplayer Engineering

INL engineers developed a special purpose software framework designed to establish real-time connections between multiple running Unity instances. The framework is developed in Unity, a game engine development platform. This framework programmatically attaches functions to engineering models, enabling users to interact with, observe, and make changes to virtual models. These interactions are broadcasted through websocket connections, and received by other engineers in real-time.

Woodruff, Nathan↗

A one-dimensional model illustrating virtual-cathode formation in a novel coaxial virtual-cathode oscillator

A one-dimensional electrostatic sheet model of a coaxial geometry Virtual Cathode Oscillator (VCO) is presented. The cathode is centrally located and connects to a peripherally located plate electrode to form a resonant cavity, and is thus considered to be a novel design. Charge is modelled as concentric sheets about the cathode whose absolute position and velocity are determined as a function of time by solving the relativistic equations of motion. The model predicts the formation of a virtual cathode between the grid and plate electrodes for the case of a space-charge limited current. Setting the electron reflexing frequency (as a function of the grid potential) comparable with the cavity resonant frequency is predicted to improve the efficiency of microwave emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Creation Synthetic Data to Train a Digital Twin to Predict Reactor Operations

Understanding techniques to strengthen the nuclear safeguards regime is crucial in preventing nuclear proliferation due to recent advancements in the nuclear energy industry such as Generation IV reactors and microreactors. Prior to the construction of a nuclear power plant, it is necessary to understand the proliferation potential of the plant's reactor. Digital twins serve as a unique solution to recognizing reactor behavior indicative of nuclear proliferation. A digital twin is defined as a virtual model that works in unison to represent a physical asset, with a transference of data between the virtual and physical assets [1]. This work serves as validation for training a digital twin on synthetic data fabricated via means of Serpent reactor physics and point kinetics equations simulations. In this case this work is based on parameters of Idaho State University's AGN-201 reactor. The synthetic data can then be utilized to train machine learning models in the future to further investigate the utility of these methods. The accuracy of the predicted data is measured against real operational data to verify the reliability of the synthetic data creation methods and decide whether these methods should be used in the future to inform inspectors of a reactor's proliferation potential.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Detector density and small field dosimetry: Integral versus point dose measurement schemes

Purpose: TheAlfonso et al. [Med. Phys.35, 5179–5186 (2008)] formalism for small field dosimetry proposes a set of correction factors (k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}) which account for differences between the detector response in nonstandard (clinical) and machine-specific-reference fields. In this study, the Monte Carlo method was used to investigate the viability of such small field correction factors for four different detectors irradiated under a variety of conditions. Because k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values for single detector position measurements are influenced by several factors, a new theoretical formalism for integrated-detector-position [dose area product (DAP)] measurements is also presented and was tested using Monte Carlo simulations. Methods: A BEAMnrc linac model was built and validated for a Varian Clinac iX accelerator. Using the egs++ geometry package, detailed virtual models were built for four different detectors: a PTW 60012 unshielded diode, a PTW 60003 Diamond detector, a PTW 31006 PinPoint (ionization chamber), and a PTW 31018 MicroLion (liquid-filled ionization chamber). The egs-chamber code was used to investigate the variation ofk{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} with detector type, detector construction, field size, off-axis position, and the azimuthal angle between the detector and beam axis. Simulations were also used to consider the DAP obtained by each detector: virtual detectors and water voxels were scanned through high resolution grids of positions extending far beyond the boundaries of the fields under consideration. Results: For each detector, the correction factor (k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}) was shown to depend strongly on detector off-axis position and detector azimuthal angle in addition to field size. In line with previous studies, substantial interdetector variation was also observed. However, it was demonstrated that by considering DAPs rather than single-detector-position dose measurements the high level of interdetector variation could be eliminated. Under small field conditions, mass density was found to be the principal determinant of water equivalence. Additionally, the mass densities of components outside the sensitive volumes were found to influence the detector response. Conclusions: k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values for existing detector designs depend on a host of variables and their calculation typically relies on the use of time-intensive Monte Carlo methods. Future moves toward density-compensated detector designs or DAP based protocols may simplify the methodology of small field dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

WE-D-303-00: Computational Phantoms

Modern medical physics deals with complex problems such as 4D radiation therapy and imaging quality optimization. Such problems involve a large number of radiological parameters, and anatomical and physiological breathing patterns. A major challenge is how to develop, test, evaluate and compare various new imaging and treatment techniques, which often involves testing over a large range of radiological parameters as well as varying patient anatomies and motions. It would be extremely challenging, if not impossible, both ethically and practically, to test every combination of parameters and every task on every type of patient under clinical conditions. Computer-based simulation using computational phantoms offers a practical technique with which to evaluate, optimize, and compare imaging technologies and methods. Within simulation, the computerized phantom provides a virtual model of the patient’s anatomy and physiology. Imaging data can be generated from it as if it was a live patient using accurate models of the physics of the imaging and treatment process. With sophisticated simulation algorithms, it is possible to perform virtual experiments entirely on the computer. By serving as virtual patients, computational phantoms hold great promise in solving some of the most complex problems in modern medical physics. In this proposed symposium, we will present the history and recent developments of computational phantom models, share experiences in their application to advanced imaging and radiation applications, and discuss their promises and limitations. Learning Objectives: Understand the need and requirements of computational phantoms in medical physics research Discuss the developments and applications of computational phantoms Know the promises and limitations of computational phantoms in solving complex problems.

60 APPLIED LIFE SCIENCES↗

WE-D-303-01: Development and Application of Digital Human Phantoms

Modern medical physics deals with complex problems such as 4D radiation therapy and imaging quality optimization. Such problems involve a large number of radiological parameters, and anatomical and physiological breathing patterns. A major challenge is how to develop, test, evaluate and compare various new imaging and treatment techniques, which often involves testing over a large range of radiological parameters as well as varying patient anatomies and motions. It would be extremely challenging, if not impossible, both ethically and practically, to test every combination of parameters and every task on every type of patient under clinical conditions. Computer-based simulation using computational phantoms offers a practical technique with which to evaluate, optimize, and compare imaging technologies and methods. Within simulation, the computerized phantom provides a virtual model of the patient’s anatomy and physiology. Imaging data can be generated from it as if it was a live patient using accurate models of the physics of the imaging and treatment process. With sophisticated simulation algorithms, it is possible to perform virtual experiments entirely on the computer. By serving as virtual patients, computational phantoms hold great promise in solving some of the most complex problems in modern medical physics. In this proposed symposium, we will present the history and recent developments of computational phantom models, share experiences in their application to advanced imaging and radiation applications, and discuss their promises and limitations. Learning Objectives: Understand the need and requirements of computational phantoms in medical physics research Discuss the developments and applications of computational phantoms Know the promises and limitations of computational phantoms in solving complex problems.

60 APPLIED LIFE SCIENCES↗

Simulation Model of Microsphere Distribution for Selective Internal Radiation Therapy Agrees With Observations

Purpose: To perform a detailed analysis of microsphere distribution in biopsy material from a patient treated with {sup 90}Y-labeled resin spheres and characterize microsphere distribution in the hepatic artery tree, and to construct a novel dichotomous bifurcation model for microsphere deposits and evaluate its accuracy in simulating the observed microsphere deposits. Methods and Materials: Our virtual model consisted of arteries that successively branched into 2 new generations of arteries at 20 nodes. The artery diameter exponentially decreased from the lowest generation to the highest generation. Three variable parameters were optimized to obtain concordance between simulations and measure microsphere distributions: an artery coefficient of variation (ACV) for the diameter of all artery generations and the microsphere flow distribution at the nodes; a hepatic tree distribution volume (HDV) for the artery tree; and an artery diameter reduction (ADR) parameter. The model was tested against previously measured activity concentrations in 84 biopsies from the liver of 1 patient. In 16 of 84 biopsies, the microsphere distribution regarding cluster size and localization in the artery tree was determined via light microscopy of 30-μm sections (mean concentration, 14 microspheres/mg; distributions divided into 3 groups with mean microsphere concentrations of 4.6, 14, and 28 microspheres/mg). Results: Single spheres and small clusters were observed in terminal arterioles, whereas large clusters, up to 450 microspheres, were observed in larger arterioles. For 14 microspheres/mg, the optimized parameter values were ACV=0.35, HDV = 50 cm{sup 3}, and ADR=6 μm. For 4.6 microspheres/mg, ACV and ADR decreased to 0.26 and 0 μm, respectively, whereas HDV increased to 130 cm{sup 3}. The opposite trend was observed for 28 microspheres/mg: ACV = 0.49, HDV = 20 cm{sup 3}, and ADR = 8 μm. Conclusion: Simulations and measurements reveal that microsphere clusters are larger and more common in volumes with high microsphere concentrations and indicate that the spatial distribution of the artery tree must be considered in estimates of microsphere distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Virtual Frame System for Stereotactic Radiosurgery Planning

Purpose: We describe a computerized (or virtual) model of a stereotactic head frame to enable planning prior to the day of radiosurgery. The location of the virtual frame acts as a guide to frame placement on the day of the procedure. Methods and Materials: The software consists of a triangular mesh representation of the essential frame hardware that can be overlaid with any MR scan of the patient and manipulated in three dimensions. The software calculates regions of the head that will actually be accessible for treatment, subject to the geometric constraints of the Leksell Gamma Knife hardware. DICOM-compliant MR images with virtual fiducial markers overlaid onto the image can then be generated for recognition by the treatment planning system. Results: Retrospective evaluation of the software on 24 previously treated patients shows a mean deviation of the position of the virtual frame from the actual frame position of 1.6 {+-} 1.3 mm. Initial clinical use on five patients indicates an average discrepancy of the virtual frame location and the actual frame location of <1 mm. MR images with virtual fiducial markers can be imported into radiosurgical treatment planning software and used to generate an initial treatment plan. Conclusions: The virtual frame provides a tool for prospective determination of lesion accessibility, optimization of the frame placement, and treatment planning before the day of the procedure. This promises to shorten overall treatment times, improve patient comfort, and reduce the need for repeat treatments due to suboptimally placed frames.

62 RADIOLOGY AND NUCLEAR MEDICINE↗