Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLATILE MATTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Differential scanning calorimetry of coal

Differential scanning calorimetry studies performed during the first year of this project demonstrated the occurrence of exothermic reactions associated with the production of volatile matter in or near the plastic region. The temperature and magnitude of the exothermic peak were observed to be strongly affected by the heating rate, sample mass and, to a lesser extent, by sample particle size. Thermal properties also were found to be influenced by oxidation of the coal sample due to weathering effects.

Gold, P. I.↗

Development of Methods of Characterizing Coal in Its Plastic State

Coal in its plastic state (typically 400-460 C) was examined by the isothermal Gieseler plastometry of seven selected coals of widely varying plastic properties. Kinetic models were proposed for the isothermal plastometric curves. Plastic behavior was compared with a variety of laboratory analyses and characterizations of these coals, including classical coal analysis; mineral analysis; microstructural analysis (extractable fractions, surface area measurement, and petrographic analysis); and thermal analysis (thermogravimetric analysis, thermomechanical analysis, and differential scanning calorimetry). The phenomenon of a sharp, large, poorly reproducible exotherm in the differential scanning calorimetric analysis of coking coals was examined. Several coal extrudates show mineral distribution, organic maceral composition and overall calorific value to be little affected by 800 F extrusion. Volatile matter and plastic properties are moderately reduced, and the network structure (as gauged by extractables) appears to be slightly degraded in the extrusion process.

Lloyd, W. G.↗

A study of the possible effect of a thermal post cure on the mechanical properties of the 404 carbon-phenolic ring of the space shuttle solid rocket motor nozzle

Erratic pockets of erosion have occurred on the inner perimeter of the 404 rocket nozzle ring during liftoff firing. It is thought that it may be caused by pockets of volatile matter entrapped during manufacture. A thermal post cure was suggested as a possible means of outgassing such pockets, if they in fact do exist. To confirm an outgassing during a post cure and to establish a working upper temperature limit, thermal gravimetric and differential calorimetric analyses were made on a number of samples from two 404 rings supplied by the manufacturer. Continuous weight loss was observed over the temperature range explored (750 F) indicating outgassing, and a strong exothermic reaction occurs beginning about 390 F. Thus, an upper post cure temperature of 350 F is recommended. To determine the possible effect of a post cure on physical properties, the following tests will be made on matched sets of cured and post cured material: x-radiography (internal structure), linear dimensions, weight, porosity, cross ply thermal expansion, drop and double notch shear strengths, and tensional strength in the ply direction.

Giardini, A. A.↗

Combustion Stages of a Single Heavy Oil Droplet in Microgravity

Heavy oil is a common fuel for industrial furnaces, boilers, marines and diesel engines. Previous studies showed that the combustion of heavy oil involves not only the complete burning of volatile matters but also the burn-out of coke residues. Detailed knowledge about heavy oil combustion therefore requires an understanding of the different burning stages of heavy oil droplets in the burner. This in turn, demands knowledge about the single droplet evaporation and combustion characteristics. This study measured the temperature and size histories of heavy oil (C glass) droplets burning in microgravity to elucidate the various stages that occur during combustion. The elimination of the gravity-induced gas convection in microgravity allows the droplet combustion to be studied in greater detail. Noting that the compositions of heavy oil are various, we also tested the fuel blends of a diesel light oil (LO) and a heavy oil residue (HOR).

Ikegami, M.↗

Forest Irrigation of Tritiated Water: A Proven Tritiated Water Management Tool - 13357

Tritium releases from the Old Radioactive Waste Burial Ground (ORWBG) at the SRS in South Carolina has impacted groundwater and surface water. Tritiated groundwater plumes discharge into Fourmile Branch which is a small tributary of the Savannah River, a regional water resource. Taking advantage of the groundwater flow paths and the local topography a water collection and irrigation system was constructed and has been used at the SRS for over a decade to reduce these tritiated water releases to Fourmile Branch. The tritiated water is transferred to the atmosphere by evaporation from the pond surface, and after irrigation, wetted surface evaporation and evapotranspiration through the forest vegetation. Over the last decade SRS has irrigated over 120,000,000 gallons of tritiated water, which diverted over 6000 curies away from Fourmile Branch and the Savannah River. The system has been effective in reducing the flux of tritiated groundwater by approximately 70%. Mass balance studies of tritium in the forest soils before operations and over the last decade indicate that approximately 90% of the tritiated water that is irrigated is transferred to the atmosphere. Dose studies indicate that exposure to site workers and offsite maximally exposed individual is very low, approximately 6 mrem/year and 0.004 mrem/year, respectively. To consistently meet the flux reduction goal of tritium into Fourmile Branch optimization activities are proposed. These efforts will increase irrigation capacity and area. An additional 17 acres are proposed for an expansion of the area to be irrigated and a planting of approximately 40 acres of pine forest plantations is underway to expand irrigation capacity. Co-mingled with the tritiated groundwater are low concentrations of chlorinated volatile organic compounds (cVOCs), and 1,4-dioxane. Research studies and SRS field data indicate the forest irrigation system may have an added benefit of reducing the mass of these co-contaminants via degradation. This semi-passive system makes use of natural processes of hydrology and evapotranspiration to manage tritium-contaminated water by reducing its entrance into site streams and the Savannah River, as well as treating low levels of co-mingled VOCs. SRS expects to operate the system until the tritium decays to levels that represent a minimal impact to Fourmile Branch and the Savannah River, and meets the stakeholder expectations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Middlesex FUSRAP Site - A Path to Site-Wide Closure - 13416

The road-map to obtaining closure of the Middlesex Sampling Plant FUSRAP site in Middlesex, New Jersey (NJ) has required a multi-faceted approach, following the CERCLA Process. Since 1998, the US ACE, ECC, and other contractors have completed much of the work required for regulatory acceptance of site closure with unrestricted use. To date, three buildings have been decontaminated, demolished, and disposed of. Two interim storage piles have been removed and disposed of, followed by the additional removal and disposal of over 87,000 tons of radiologically and chemically-impacted subsurface soils by the summer of 2008. The US ACE received a determination from the EPA for the soils Operable Unit, (OU)-1, in September 2010 that the remedial excavations were acceptable, and meet the criteria for unrestricted use as required by the 2004 Record of Decision (ROD) for OU-1. Following the completion of OU-1, the project delivery team performed additional field investigation of the final Operable Unit for Middlesex, OU-2, Groundwater. As of December 2012, the project delivery team has completed a Supplemental Remedial Investigation, which will be followed with a streamlined Feasibility Study, Proposed Plan, and ROD. Several years of historical groundwater data was available from previous investigations and the FUSRAP Environmental Surveillance Program. Historical data indicated sporadic detections of Volatile Organic Compounds (VOCs), primarily trichloroethylene (TCE), carbon tetrachloride (CT), and methyl tert-butyl ether (MTBE), with no apparent trend or pattern indicating extent or source of the VOC impact. In 2008, the project delivery team initiated efforts to re-assess the Conceptual Site Model (CSM) for groundwater. The bedrock was re-evaluated as a leaky multi-unit aquifer, and a plan was developed for additional investigations for adequate bedrock characterization and delineation of groundwater contaminated primarily by CT, TCE, and tetrachloroethene (PCE). The investigation was designed to accumulate multiple lines of evidence to determine the source and to delineate the extent of contamination, as required to complete the CERCLA Process and gain regulatory acceptance. Investigative techniques included in-well vertical flow tracing, borehole geophysics and packer testing of temporary test holes to characterize contamination in the bedrock fractures beneath the site, and to delineate likely source areas. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater Transport of Organic Compounds in Old Salvage Yard, Oak Ridge, TN - 12089

In 1950's and early 1960's during production of nuclear weapons at the US Department of Energy Y-12 National Security Complex in Oak Ridge TN, volatile organic compounds (VOCs) as well as heavy metals, nitrates, and radionuclides were released to the environment. Field investigations revealed that much of this contamination is still present in soil, bedrock, and groundwater. Operational buildings and old disposal facilities at the site have been identified as major sources of contamination. The Old Salvage Yard (OSY) on the western side of the site has long been characterized as the major source of VOC contamination in soil and groundwater. In order to analyze the fate and transport of VOC contamination- including tetrachloroethene (PCE), 1,2- dichloroethene (1,2-DCE), cis-1,2-dichloroethene (cis-1,2-DCE) and vinyl chloride (VC) - in groundwater and soil at the vicinity of OSY, an integrated surface and subsurface flow and transport model has been developed for the Y-12 NSC using the hydrodynamic and transport numerical package, MIKE-SHE. Hydrogeological characteristics of the site such as hydraulic conductivity, and transport parameters such as partitioning coefficients were varied in an effort to delineate subsurface flow and transport pathways, potential downstream impacts on Upper East Fork Poplar Creek, and the potential risk to industrial workers involved in related Decontamination and Decommissioning (D and D) activities. The simulation results were compared with the analytical modeling results previously performed by McLane Environmental Inc. using SESOIL-AT123D. Specific simulations have been performed to investigate the effect of possible remedial action (removing the contaminated surface soil layers) on the fate and transport of VOCs. The results of the MIKE-SHE reported here can be considered as an upper limit for the predicted concentrations. Based on MIKE-SHE results, PCE, 1,2 DCE, cis-1,2-DCE, and VC are sources in soil with potential to equal or exceed industrial groundwater hazard and risk levels at the vicinity of OSY. VOC contaminants in soil and groundwater will decay below industrial groundwater risk and hazard levels within approximately 20 years. Excavation of surface soil layers at the site will considerably reduce the concentration of VOCs in groundwater and the possibility of migration of VOCs to surface waters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solar-Powered Air Stripping at the Rocky Flats Site, Colorado - 12361

The U.S. Department of Energy's Rocky Flats Site (the Site), near Denver, Colorado, is a former nuclear weapons facility that was constructed beginning in 1951. With the end of the Cold War, the Site was cleaned up and closed in 2005. Four gravity-driven groundwater treatment systems were installed during cleanup, and their continued operation was incorporated into the final remedy for the Site. All utilities, including electrical power, were removed as part of this closure, so all Site electrical power needs are now met with small solar-powered systems. The Mound Site Plume Treatment System (MSPTS) was installed in 1998 as an innovative system based on zero-valent iron (ZVI). Groundwater flow from the Mound source area containing elevated concentrations of volatile organic compounds (VOCs), primarily in the tetrachloroethene (PCE)-trichloroethene (TCE) family of chlorinated solvents, is intercepted by a collection trench and routed to twin ZVI treatment cells. Later, in 2005, remediation of VOC-contaminated soils at a second up-gradient source area included adding an electron donor to the backfill to help stimulate biodegradation. This reduced concentrations of primary constituents but caused down-gradient groundwater to contain elevated levels of recalcitrant degradation byproducts, particularly cis-1,2-dichloroethene and vinyl chloride. A gravel drain installed as part of the 2005 remediation directs contaminated groundwater from this second source area to the MSPTS for treatment. This additional contaminant load, coupled with correspondingly reduced residence time within the ZVI media due to the increased flow rate, resulted in reduced treatment effectiveness. Elevated concentrations of VOCs were then detected in MSPTS effluent, as well as in surface water at the downstream performance monitoring location for the MSPTS. Subsequent consultations with the Site regulators led to the decision to add a polishing component to reduce residual VOCs in MSPTS effluent. Initially, several alternatives such as commercial air strippers and cascade aerators were evaluated; resulting cost estimates exceeded $100,000. After several simpler alternatives were considered and prototype testing was conducted, the existing effluent metering manhole was converted to house a spray-nozzle based, solar-powered air stripper, at a cost of approximately $20,000. About two-thirds of this cost was for the solar power system, which was initially designed to only provide power for 12 hours per day. Performance data are being collected and adjustments made to optimize the design, determine maintenance requirements, and establish power needs for continuous operation. Analytical data confirm the air stripper is sharply reducing concentrations of residual contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vapor Intrusion Mitigation Beneath an Occupied Industrial Building at the Young - Rainey Science, Technology, and Research Center Largo, Florida - 17463

Groundwater contamination, consisting of chlorinated solvents, was identified in the southeastern portion of the Pinellas Site in Largo, Florida. The contamination is beneath Building 100, an 11-acre building that housed manufacturing facilities during US Department of Energy (DOE) operations at the site. Because the building was constructed in phases over a period of decades, it is comprised of approximately 20 different buildings, each with a separate foundation, all of which are now connected under a single roof. Based on the results of a pilot test that indicated the presence of volatile organic compounds beneath the floor slab and, in the absence of state regulations or guidance, DOE elected to proactively address the potential for release of these compounds into the facility by designing and installing a vapor intrusion (VI) mitigation system. To ventilate vapors from beneath the building, piping was installed from beneath the concrete floor slab through the roof, and negative pressure was created using electric blowers. The system design was complicated by foundation walls supporting each of the various sections of Building 100 and by special requirements due to the sensitive nature of the tenant's manufacturing activities and the heightened need for security. This paper addresses significant aspects of the design and construction of a VI mitigation system beneath a large, occupied industrial production facility, including technical, logistical, and environmental challenges; community relations; and regulatory relations. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Concluding a steam injection remediation project at a dense non-aqueous phase liquid source zone at the Savannah River site - 15303

Multiple subsurface dense non-aqueous phase liquid (DNAPL) source zones served as the sources for a groundwater plume within the A/M Area of the Savannah River Site. Between 1952 and 1985 over 1,600 metric tons of trichloroethylene, tetrachloroethylene, and 1,1,1-trichloroethane were released to the environment resulting in a 648 hectare plume with the M-Area Settling Basin receiving over half of the solvent discharges. In 1991, DNAPL was found in a water table well and steam injection technology was selected to remediate the source zone. Based on characterization data, the treatment area was 1.21 hectare with depths between 13.7 to 50.3 m. The remediation system included 96 vertical, horizontal, and angled steam injection and soil vapor extraction wells and a thermal monitoring system. Construction of the system began in 2004 and operation began in 2005. Steam was applied to the deep vadose zone first, then progressed to the aquifer, followed by the mid-vadose zone. Multiple steam strategies were utilized to enhance mass removal and were concluded in 2009. Soil vapor extraction continues, with residual temperatures in the deep permeability zones still exceeding 65 deg.C. To date over 204 metric tons of volatile organic compounds (VOCs) have been removed. Post-remediation soil, vapor, temperature, and groundwater data were used to evaluate steam injection effectiveness and demonstrated significant reduction in soil concentration, including removal of DNAPL that was evident in several soil cores prior to treatment. Heating the subsurface increased VOC solubility in groundwater and increased mass removal rates outside the target zone. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress toward cleanup of operable unit 1 groundwater at the US DOE0 Mound, Ohio, site: success of a phased-combined remedy - 15310

Industrial solvents (primarily trichloroethene) and other volatile organic compounds (VOCs) that originated from the former solid waste landfill contaminated the groundwater in the Buried Valley Aquifer beneath the Mound, Ohio, Site. The landfill was used from 1948 to 1974 for the disposal of trash, debris, and liquid waste. In 1977, much of the waste was relocated and encapsulated onsite. The landfill site and surrounding area (Operable Unit 1 [OU-1]) occupy approximately 1.6 hectares (4 acres) in the southwestern portion of the site. The historical pathway of concern consisted of leaching of contaminants from site soils or disposed wastes down into the groundwater, entrainment in the flowing groundwater, and migration toward former Mound site water-production wells. A groundwater pump-and-treat (P and T) system was initiated in 1996 to interdict the plume and a soil vapor extraction system was installed and operated from 1997 to 2003 to remove the bulk of the VOC sources from the vadose zone. Physical removal of the landfill waste and contaminated soil was performed between 2006 and 2010. Approximately 76,000 cubic meters (99,400 cubic yards) of material were removed from the OU-1 landfill area; the remaining soils in the OU-1 area meet the site cleanup objectives for future industrial or commercial use. Operation of the groundwater P and T system continued throughout this period. During the remediation time frame, groundwater monitoring and a number of innovative characterization campaigns were completed to assess the contaminant and biogeochemical conditions in the subsurface at OU-1. For example, in 2013 an integral pumping test was performed to characterize the amount (mass) of the low-level VOCs in groundwater. Soil and groundwater were also collected to obtain site-specific data to identify if geochemical conditions support natural attenuation reactions. Contaminant and hydrogeologic data collected from this test, as well as historical data, were evaluated to identify the distribution and potential sources of VOCs, refine the hydrogeologic description, update the conceptual model of VOC fate and transport, and determine if monitored natural attenuation remains a viable option to address VOCs in groundwater. To date, the performance of the phased-combined remedy has resulted in significant reductions in the concentrations of VOCs in the groundwater. For example, in 2013 the trichloroethene in all wells was less than 40 micrograms per liter, with a plurality of the wells near or below maximum contaminant levels. The generally observed declining concentration trends and the low concentrations for 2013 represent the net impact of source removal actions, P and T operation, and natural attenuation. In accordance with the current conditions, the joint US DOE and regulator Core Team is proceeding with a field demonstration of enhanced attenuation-an engineering and regulatory strategy that was recently developed by the Interstate Technology and Regulatory Council. Enhanced attenuation strategies focus on altering a target site in such a way that it can transition to natural attenuation. The combination of technologies to be deployed includes neat (pure) vegetable oil deployment in the deep vadose zone of the former landfill area and emulsified vegetable oil deployment within the footprint of the groundwater plume. In the first part of the deployment, neat oil spreads laterally and forms a thin layer on the water table beneath residual soil sources to intercept and reduce future VOC loading and to reduce oxygen inputs to the local groundwater. In the second part of the deployment, emulsified oil forms active bioremediation treatment zones within the plume footprint to degrade existing groundwater contaminants (via reductive dechlorination, co-metabolism, or both) and stimulates long-term attenuation capacity in the down-gradient plume (via co-metabolism). If the proposed activities are successful, they will accelerate the progress of the Mound OU-1 toward remedial goals and convert the current active P and T remedy into a passive attenuation-based remedy that represents a cost-effective final step in a phased remediation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A GIS-Based Suitability Analysis of a Phytomanagment Strategy for TCE in Groundwater and Soil Niagara Falls Storage Site, New York - 19385

The large number of complexly contaminated sites throughout the nation has propagated the application of phytoremedial techniques in a wide array of environmental remediation strategies. The use and breeding of vegetation for the in-situ treatment of environmental media (soil, groundwater, sediment) contaminated with organic or inorganic contaminants has shown to provide a low-cost alternative to conventional means of remediating contaminated sites (e.g., groundwater extraction, chemical oxidation or reduction, bioremediation, excavation, etc.). One impediment to effective phytoremediation is the selection of proper plant-species, which is complicated due to the many variables that are required for plant-species viability (i.e. range of soil pH, annual precipitation values, depth to groundwater table, etc.). This study employed the use of a Geographic Information Systems (GIS) to first define the spatial extent of contaminated media (soil and groundwater) at a project site and then support an effective means to optimize phytoremediative techniques to manage these impacts prior to final remediation. Spatial analyses and analytical calculations were coupled to determine an optimal plant species and spacing to maximize the effectiveness of a phytomanagement plan. The incorporation of fuzzy membership functions and fuzzy overlay provide an innovative method to help select the optimal plant-species for phytomanagement planning. Fuzzy membership functions were used to represent the plant growth requirements and provided an intuitive method to represent the uncertainty associated with plant-growth requirements. The fuzzy overlay function then employed a raster-based suitability analysis that together provided decision makers with a scientific solution to optimally design a phytomanagement strategy for site-related volatile organic compound (VOC) impacts. The Niagara Falls Storage Site (NFSS) VOC-impacted groundwater is contained in clayey glacial sediments, which commonly are technically impractical to remediate. Prior on-site studies show that native poplar (cottonwood variants) preferentially translocate or phytoextract the VOCs from the site soils and thus provide a proven mechanism to manage the multi-media impacts. Consequently, the Army Corps of Engineers Buffalo District evaluated phytoremediative approaches as a passive tool to manage the VOCs during the project life cycle prior to final remediation. The fuzzy membership functions and fuzzy overlay modeling of candidate species narrowed the selection to an optimal species and subsequent transpiration modeling estimated the plant spacing for the overall phytomanagement plan. The method employed for this study is easy applied to other phytoremediative and phytomanagement actions derived from hazardous waste decision making. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculating the Effects of Solids Input and Removal as a Temperature Control in the Advanced Scale Up Reactor Experiment (ASURE) Facility at NETL Using Aspen

The Advanced Scale Up Reactor Experiment (ASURE) facility at NETL is being designed to be a fuel-flexible multi-purpose reactor that can be used for pyrolysis/gasification or evaluation of other high pressure “circulating fluidized bed” (CFB) chemical processes. The initial system design calculations for pyrolysis/gasification are presented in this work showing the expected performance of the ASURE facility when used as a biomass conversion reactor. Several other areas of application include gasification of any carbonaceous fuel including biomass, coal, plastics, and other waste materials. The reactor can therefore be used to produce SYNGAS of various compositions and hydrogen as well as other high value chemicals resulting from a typical tuned gasification process. This paper discusses an ASPEN model of the facility, focusing on the riser of the CFB reactor and the solids recirculation loop. The ASPEN model divides the riser into two sections. A bottom section which receives ash, char and sand which have been recirculated from a return loop. In this section an inert fluidization gas, (N2 or CO2), is introduced which acts as the primary mover of the solids through the system. The bottom section is equipped with a restricted air feed so that the recirculated char can be partially oxidized. This oxidation process along with the inventory of recirculating sand are used to effectively control the temperature in the following two chemical conversion sections of the reactor which are the pyrolysis zone followed by a tar cracking zone. Fresh fuel is added to the pyrolysis zone and undergoes drying and devolatilization. The products ash, char, volatile matter, and water vapor exit the pyrolysis zone and enter the reaction block for tar cracking. Steam and CO2 gasification reactions will be incorporated into the tar cracking zone, however at the design operating temperature, conversion from these reactions is expected to be essentially zero. The unit when completed in 2026 will test mixtures of biomass, plastics, and waste coal. This paper presents the basic ASPEN engineering design model for this project and provides preliminary sensitivity studies to determine how the various parts of the reactor will perform.

ASSURE↗

Development and Application of A Membrane-Based Thermodenuder for Measurement of Volatile Particles Emitted by A Jet Turbine Engine

Measurement of volatile particles emitted by modern jet engines is a daunting task. Besides the complexity in sampling jet aircraft exhaust, the main difficulty lies at how to faithfully capture the phase-partition dynamics of volatile particles as they travel downstream from the engine exhaust nozzle. As a result, the physico-chemical properties of the exhaust are also transformed. We have developed a sampling instrument that aims at enabling study of the phase-partition dynamics. The objective of this research project was to design and evaluate a new thermodenuder for performing phase separation of the engine-emitted volatile particles. The backbone of the new thermodenuder is a thin metallic membrane. The membrane enables extraction of molecules that can be thermally desorbed from the condensed particulate phases and collected for subsequent chemical analysis. Toward realization of the technique in the future field aircraft emissions measurement we tested this new thermo-denuding device using laboratory-generated particles that were made of non-volatile or semi-volatile chemicals. The particle penetration efficiency, a measure of the device performance, of this thermodenuder was found to be better than 99%. Results obtained from the tests executed at a number of operating temperature conditions show reasonably good thermal separation. We have scheduled to apply this new device to characterize emissions from a T63 turboshaft engine in the spring of 2010 and are expecting to show the engine results at the conference. The test results based on the laboratory-generated particles were encouraging for the intended application. With excellent particle transmission efficiency and an ability to simultaneously measure the composition in the gas and particle phases of the engine particles, we believe the new technology will make a great contribution to measurement research of engine emissions.

47 OTHER INSTRUMENTATION↗

Subtask 3.4 – Fischer–Tropsch Fuels Development

Under Subtask 3.4, the Energy & Environmental Research Center (EERC) examined the opportunities and challenges facing Fischer–Tropsch (FT) technology in the United States today. Work was completed in two distinct budget periods (BPs). In BP1, the EERC examined the technical feasibility of using modern warm-gas cleanup techniques for FT synthesis. FT synthesis is typically done using more expensive and complex cold-gas sweetening. Warm-gas cleanup could greatly reduce capital and operating costs, making FT synthesis more attractive for domestic fuel production. Syngas was generated from a variety of coal and biomass types; cleaned of sulfur, moisture, and condensables; and then passed over a pilot-scale FT catalyst bed. Laboratory and modeling work done in support of the pilot-scale effort suggested that the catalyst was performing suboptimally with warm-gas cleanup. Long-term trends showed that the catalyst was also quickly deactivating. In BP3, the EERC compared FT catalyst results using warm-gas cleanup to results using cold-gas sweetening. A gas-sweetening absorption system (GSAS) was designed, modeled, and constructed to sweeten syngas between the gasifier and the pilot-scale FT reactor. Results verified that the catalyst performed much better with gas sweetening than it had with warm-gas cleanup. The catalyst also showed no signs of rapid deactivation when the GSAS was running. Laboratory tests in support of this effort verified that the catalyst had deactivated quickly in BP1 because of exposure to syngas, not because of any design flaw with the pilot-scale FT reactor itself. Based on these results, the EERC concludes that the two biggest issues with using syngas treated with warm-gas cleanup for FT synthesis are high concentrations of CO 2 and volatile organic matter. Other catalysts tested by the EERC may be more tolerant of CO 2 , but volatile matter removal is critical to ensuring long-term FT catalyst operation. This subtask was funded through the EERC–U.S. Department of Energy (DOE) Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding for BP1 was provided by the North Dakota Industrial Commission’s (NDIC) Renewable Energy Council.

10 SYNTHETIC FUELS↗

Silica-volatile interaction and the geological cause of the Xuan Wei lung cancer epidemic

Parts of Xuan Wei County, Yunnan Province, China have the highest known lung cancer mortality in nonsmoking women. This high mortality displays a clear spatial relationship to the mines producing coal from the uppermost Permian. Geochemical, petrographic, and grain size analyses were undertaken on a set of coal samples from Xuan Wei. Results demonstrate that the single geochemical property that makes this coal unusual is its high concentration of quartz (13.5 wt %) of which 35-55% occurs as < 10 {mu}m grains. We propose the potential for silica-volatile interaction (PSVI) as a new method for assessing the combined influence of silica and volatile organic matter and use this as a basis for re-evaluating existing ecological data. Published lung cancer mortality values are more strongly correlated with PSVI values for Xuan Wei coal than with volatiles or silica alone and the PSVI values measured are distinct from those of other coals. Finally we propose that the localization of this epidemic to Xuan Wei results from enhanced weathering of the local Emeishan basalts as a consequence of geochemical perturbations at the Permo-Triassic Boundary.

01 COAL, LIGNITE, AND PEAT↗

A Comprehensive Program for Measurement of Military Aircraft Emissions

Emissions of gases and particulate matter by military aircraft were characterized inplume by 'extractive' and 'optical remote-sensing (ORS)' technologies. Non-volatile particle size distribution, number and mass concentrations were measured with good precision and reproducibly. Time-integrated particulate filter samples were collected and analyzed for smoke number, elemental composition, carbon contents, and sulfate. Observed at EEP the geometric mean diameter (as measured by the mobility diameter) generally increased as the engine power setting increased, which is consistent with downstream observations. The modal diameters at the downstream locations are larger than that at EEP at the same engine power level. The results indicate that engine particles were processed by condensation, for example, leading to particle growth in-plume. Elemental analysis indicated little metals were present in the exhaust, while most of the exhaust materials in the particulate phase were carbon and sulfate (in the JP-8 fuel). CO, CO{sub 2}, NO, NO{sub 2}, SO{sub 2}, HCHO, ethylene, acetylene, propylene, and alkanes were measured. The last five species were most noticeable under engine idle condition. The levels of hydrocarbons emitted at high engine power level were generally below the detection limits. ORS techniques yielded real-time gaseous measurement, but the same techniques could not be extended directly to ultrafine particles found in all engine exhausts. The results validated sampling methodology and measurement techniques used for non-volatile particulate aircraft emissions, which also highlighted the needs for further research on sampling and measurement for volatile particulate matter and semi-volatile species in the engine exhaust especially at the low engine power setting.

33 ADVANCED PROPULSION SYSTEMS↗