Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VISCOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

ZBLAN Viscosity Instrumentation

The past year's contribution from Dr. Kaukler's experimental effort consists of these 5 parts: a) Construction and proof-of-concept testing of a novel shearing plate viscometer designed to produce small shear rates and operate at elevated temperatures; b) Preparing nonlinear polymeric materials to serve as standards of nonlinear Theological behavior; c) Measurements and evaluation of above materials for nonlinear rheometric behavior at room temperature using commercial spinning cone and plate viscometers available in the lab; d) Preparing specimens from various forms of pitch for quantitative comparative testing in a Dynamic Mechanical Analyzer, Thermal Mechanical Analyzer; and Archeological Analyzer; e) Arranging to have sets of pitch specimens tested using the various instruments listed above, from different manufacturers, to form a baseline of the viscosity variation with temperature using the different test modes offered by these instruments by compiling the data collected from the various test results. Our focus in this project is the shear thinning behavior of ZBLAN glass over a wide range of temperature. Experimentally, there are no standard techniques to perform such measurements on glasses, particularly at elevated temperatures. Literature reviews to date have shown that shear thinning in certain glasses appears to occur, but no data is available for ZBLAN glass. The best techniques to find shear thinning behavior require the application of very low rates of shear. In addition, because the onset of the thinning behavior occurs at an unknown elevated temperature, the instruments used in this study must provide controlled low rates of shear and do so for temperatures approaching 600 C. In this regard, a novel shearing parallel plate viscometer was designed and a prototype built and tested.

Kaukler, William↗

Transient Torque Method: A Fast and Non-Intrusive Technique to Simultaneously Determine Viscosity and Electrical Conductivity of Semiconducting and Metallic Melts

A transient torque method was developed to rapidly and simultaneously determine the viscosity and electrical conductivity of semiconducting or metallic melts. The experimental setup is similar to that for the oscillation cup technique. The melt sample is sealed inside a fused silica ampoule, and the ampoule is suspended by a long quartz fiber to form a torsional oscillation system. A rotating magnetic field is used to induce a rotating flow in the conductive melt, which causes the ampoule to rotate along its axis. A sensitive angular detector is used to measure the deflection angle of the ampoule. Based on the transient behavior of the deflection angle as the rotating magnetic field is applied, the electrical conductivity and viscosity of the melt can be obtained simultaneously by numerically fitting the data to a set of governing equations. The transient torque viscometer was applied successfully to measure the viscosity and electrical conductivity of high purity mercury at 53.4 C. The results were in excellent agreement with the published data. The main advantage of the technique is that the measurement can be completed in one or two minutes, as opposed to the one or two-hour measurement time required by the oscillation cup technique. The method is non-intrusive; capable of rapid measurement of the viscosity of toxic, high vapor pressure melts at elevated temperatures. In addition, the transient torque viscometer can also be operated as an oscillation cup viscometer if desired.

Li, C.↗

Transient Torque Method: A Fast and Nonintrusive Technique to Simultaneously Determine Viscosity and Electrical Conductivity of Semiconducting and Metallic Melts

A transient torque method was developed to rapidly and simultaneously determine the viscosity and electrical conductivity of liquid metals and molten semiconductors. The experimental setup of the transient torque method is similar to that of the oscillation cup method. The melt sample is sealed inside a fused silica ampoule, and the ampoule is suspended by a long quartz fiber to form a torsional oscillation system. A rotating magnetic field is used to induce a rotating flow in the conductive melt, which causes the ampoule to rotate around its vertical axis. A sensitive angular detector is used to measure the deflection angle of the ampoule. Based on the transient behavior of the deflection angle as the rotating magnetic field is applied, the electrical conductivity and viscosity of the melt can be obtained simultaneously by numerically fitting the data to a set of governing equations. The transient torque viscometer was applied successfully to measure the viscosity and electrical conductivity of high purity mercury at 53.4 C. The results were in excellent agreement with published data. The method is nonintrusive; capable of rapid measurement of the viscosity of toxic, high vapor pressure melts at elevated temperatures. In addition, the transient torque viscometer can also be operated as an oscillation cup viscometer to measure just the viscosity of the melt or as a rotating magnetic field method to determine the electrical conductivity of a melt or a solid if desired.

Li, C.↗

In Pursuit of a High-Temperature, High-Pressure, High-Viscosity Standard: The Case of Tris(2-ethylhexyl) Trimellitate

This study presents a reference correlation for the viscosity of tris(2-ethylhexyl) trimellitate designed to serve in industrial applications for the calibration of viscometers at elevated temperatures and pressures such as those encountered in the exploration of oil reservoirs and in lubrication. Tris(2-ethylhexyl) trimellitate has been examined with respect to the criteria necessary for an industrial standard reference material such as toxicity, thermal stability, and variability among manufactured lots. The viscosity correlation has been based upon all of the data collected in a multinational project and is supported by careful measurements and analysis of all the supporting thermophysical property data that are needed to apply the standard for calibration to a wide variety of viscometers. The standard reference viscosity data cover temperatures from 303 to 473 K, pressures from 0.1 to 200 MPa, and viscosities from approximately 1.6 to 755 mPa s. The uncertainty in the data provided is of the order of 3.2% at 95% confidence level, which is thought to be adequate for most industrial applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated electronic transport and thermometry at milliKelvin temperatures and in strong magnetic fields

We fabricated a He-3 immersion cell for transport measurements of semiconductor nanostructures at ultra low temperatures and in strong magnetic fields. We have a new scheme of field-independent thermometry based on quartz tuning fork Helium-3 viscometry which monitors the local temperature of the sample's environment in real time. The operation and measurement circuitry of the quartz viscometer is described in detail. We provide evidence that the temperature of two-dimensional electron gas confined to a GaAs quantum well follows the temperature of the quartz viscometer down to 4 mK.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An analysis of HS6-5-2 steel viscosity in the semi-solid state

The main objective of this study was an analysis of the rheological properties of selected steel alloy in the semi-solid state. A knowledge of the rheological properties of material is crucial for the numerical modeling of the shaping technology. Semi-solid processing of metal alloys, also known as thixoforming processes, is an innovative method which has many advantages in comparison with classical metal forming and foundry processes. The most significant achievement of this particular study is the application of a viscometer which was specially designed for material tests executed at extremely high temperatures, such as the measurement of liquid or semi-liquid steel viscosity. This paper presents the results of a rheological analysis of HS6-5-2 (PN SW7M) tool steel. It was performed using a rotational viscometer with a stationary external cup. The results were used for the development of mathematical models of the apparent viscosity.

36 MATERIALS SCIENCE↗

Viscous flow properties and hydrodynamic diameter of phenothiazine-based redox-active molecules in different supporting salt environments

We report viscous flow properties of a redox-active organic molecule, N-(2-(2-methoxyethoxy)ethyl)phenothiazine (MEEPT), a candidate for non-aqueous redox flow batteries, and two of its radical cation salts. A microfluidic viscometer enabled the use of small sample volumes in determining viscosity as a function of shear rate and concentration in the non-aqueous solvent, acetonitrile, both with and without supporting salts. All solutions tested show Newtonian behavior over shear rates of up to 30 000 s−1, which was rationalized by scaling arguments for the diffusion-based relaxation time of a single MEEPT molecule without aggregation. Neat MEEPT is flowable but with a large viscosity (412 mPa⋅s at room temperature), which is ∼1000 times larger than that of acetonitrile. MEEPT solutions in acetonitrile have low viscosities; at concentrations up to 0.5 M, the viscosity increases by less than a factor of two. From concentration-dependent viscosity measurements, molecular information was inferred from intrinsic viscosity (hydrodynamic diameter) and the Huggins coefficient (interactions). Model fit credibility was assessed using the Bayesian Information Criterion. It is found that the MEEPT and its charged cations are “flowable” and do not flocculate at concentrations up to 0.5 M. MEEPT has a hydrodynamic diameter of around 8.5 Å, which is almost insensitive to supporting salt and state of charge. This size is comparable to molecular dimensions of single molecules obtained from optimized structures using density functional theory calculations. The results suggest that MEEPT is a promising candidate for redox flow batteries in terms of its viscous flow properties.

Wang, Yilin (ORCID:0000000316102995)↗

FY23 Progress Report on Viscosity and Thermal Conductivity Measurements of Molten Salts

As presented in this report, thermal conductivity and viscosity measurements were performed on key chloride pseudo-binary molten salt systems of relevance to molten salt reactor developers. Thermal conductivity measurements were conducted with a variable gap technique, in which a known heat flux is driven across a molten salt specimen and the temperature difference is measured, allowing calculation of the thermal conductivity. This is achieved by establishing a small gap between the bottom of a cylindrical inner containment, which houses electrical heating elements, and an outer containment, which houses cooling channels; the gap size can be varied by compression of a formed bellows. A new calibration scheme was developed herein, involving a correction factor to the heat flux based on He measurements at various temperatures. Furthermore, the data processing methodology was improved to minimize the impact of radiative heat transfer in the calculation of salt specimen thermal conductivity from the temperature difference measurements. Viscosity measurements were conducted with a rolling ball viscometer, in which a ball rolls some known distance in an angled tubular crucible, and the terminal velocity can be used to calculate the viscosity of the salt. The measurement can be performed in a quartz crucible, with which a standard camera can be used to track the ball, or in a metal crucible, with which x-ray radiography is required to track the ball. A new custom x-ray system was made and dedicated to the rolling ball viscometer to enable high throughput automated measurements with salts which require containment with metal. Both systems have been integrated with a ventilation stack which allows for off-gassing of radioactive material, enabling future measurements with U-bearing salts. The thermal conductivity measurements performed herein were with NaCl-KCl (44 mol% NaCl). This salt system was measured in the previous fiscal year, however the thermal conductivity values obtained were comparatively low, and so the system was remeasured with the aforementioned calibration scheme and improved post-processing techniques. The newly obtained thermal conductivity values for NaCl-KCl (44 mol% NaCl) indicate good agreement with kinetic theory and ab-initio models (within 5–10 %). The viscosity measurements performed herein were with three different compositions of NaCl-KCl: 75, 50, and 25 mol% NaCl; a new calibration scheme was applied to account for variable flow effects in the laminar regime. The results show reasonable agreement with literature (5–20 %, depending on the temperature, composition, and study); however, literature values are likely higher than true values based on pure end-member measurements performed in the comparative studies. The measurements conducted herein do show a trend such that viscosity increases with increasing NaCl concentration, which agrees well with one of two comparative studies. In general, the measurements conducted herein gives confidence in the capability to use these systems to accurately measure thermal conductivity and viscosity of actinide-bearing salts within the next fiscal year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Rheology Models on Horizontal Well Polymer Flooding in a Heavy Oil Reservoir on Alaska North Slope: A Simulation Study

Polymer rheology can have either a positive or a negative effect on polymer flooding performance under varied circumstances. Many researchers have studied the effect of polymer rheology in a vertical well, but no field scale studies have been conducted to investigate whether polymer rheology is beneficial to polymer flooding in heavy oil reservoirs developed by horizontal wells. In this paper, we conducted a numerical simulation study to examine the effect of HPAM polymer rheology on a polymer flooding pilot, which is the first-ever project conducted on a heavy oil reservoir from Alaska North Slope (ANS) developed by horizontal wells. Three rheology types were considered in the study including the apparent viscosity measured during coreflooding of using a HPAM polymer, the bulk viscosity measured with a viscometer, and a Newtonian flow model. The results suggest that using the bulk viscosity in simulation underestimates the conformance control and the water-oil-ratio reduction capability of the HPAM polymer solution. When the apparent viscosity is used, the incremental oil and sweep were largely increased, and the optimal recovery period of polymer flooding was extended greatly, especially for the heterogeneous formations. Therefore, the rheology type of polymer plays a significant role in the incremental oil recovery and injection profile of the horizontal well system given the pilot test conditions. This study has provided practical guidance to field operators for the ongoing polymer flooding pilot on ANS and will also provide valuable information for other polymer projects conducted in similar conditions.

Leng, Jianqiao↗

Hematological Viscometry

Concepts and defining equations for the design of a relative velocity blood viscometer are reported. The device consists of two cone and plate chambers, a variable speed drive, and rotational velocity detectors. Two con-plate systems are directly coupled with one system driving the other through the viscous drag transmitted in the test fluid. Angular velocity measurements are processed electronically. A brief description of current viscometer designs is included.

West, D. R.↗

Surface temperatures and glassy state investigations in tribology, part 4

Measurements were made of the limiting shear stress for two naphthenic oils of differing molecular weight and three blends of the lower molecular weight oil and polyalkylmethacrylate polymers of differing molecular weight. The two base oils reached the same limiting shear stress for the same temperature and pressure. This was also true for all the polymer solutions although the polymer reduced the limiting shear stress by about 15 percent. It is shown that limiting stress is more a function of material type than viscosity or molecular weight. A new falling body viscometer was constructed to operate to 230 C and 0.6 GPa. Another viscometer was constructed to extend the pressure range to 1.1 GPa. A concentrated contact simulator was developed which allows recording of the traction force while the slide-roll ratio is continuously varied and the rolling speed is maintained essentially constant by a single drive motor. The configuration is that of a crowned roller against a disk. Measurement of lubricant minimum film thickness of elliptical EHD contacts of various aspect ratios were made by optical interferometry. The data collected were used to evaluate the Hamrock and Dowson minimum film thickness model over a range of contract ellipticity ratio where the major axis of the contact ellipse was aligned both parallel and perpendicular to the direction of motion. A statistical analysis of the measured film thickness data showed that on the average the experimental data were 30 percent greater than the film thickness predicted by the model. Preliminary development of the application of a scanning infrared radiation system to a tribo-system was completed.

Bair, S. S.↗

High Accuracy Fuel Flowmeter, Phase 1

Technology related to aircraft fuel mass - flowmeters was reviewed to determine what flowmeter types could provide 0.25%-of-point accuracy over a 50 to one range in flowrates. Three types were selected and were further analyzed to determine what problem areas prevented them from meeting the high accuracy requirement, and what the further development needs were for each. A dual-turbine volumetric flowmeter with densi-viscometer and microprocessor compensation was selected for its relative simplicity and fast response time. An angular momentum type with a motor-driven, spring-restrained turbine and viscosity shroud was selected for its direct mass-flow output. This concept also employed a turbine for fast response and a microcomputer for accurate viscosity compensation. The third concept employed a vortex precession volumetric flowmeter and was selected for its unobtrusive design. Like the turbine flowmeter, it uses a densi-viscometer and microprocessor for density correction and accurate viscosity compensation.

Mayer, C.↗

Science Requirements for a Space Flight Experiment Entitled Critical Viscosity of Xenon

We propose to measure in low gravity the viscosity of xenon close to its critical point. The accuracy will be sufficient to eliminate uncertainties currently associated with the analysis of l-g experiments. The measurements will provide the first direct observation of the predicted power-law divergence of viscosity in a pure fluid. The measurements will also strengthen Zeno's test of mode coupling theory by greatly increasing the reliability of the extrapolation of viscosity to low reduced temperatures. Our scientific objectives are described in more detail in one of the attached reports. The low-gravity experiment will be the final stage of a program whose completed ground-based stages are: (1) theoretical studies by one of the principal investigators (MRM) and coworkers, (2) critical viscosity measurements of binary liquid mixtures, (3) critical viscosity measurements of pure fluids in l-g, and development of a suitable vibration-insensitive viscometer. Our technical approach is described in the draft Science Requirements Document. One of us (MRM) has reviewed opportunities for critical phenomena research in low gravity. Both of us were co-principal investigators in the Thermal Equilibration Experiment in the Critical Point Facility, flown on IML-1 in 1992. From this experience, and from the technical maturity of our ground-based work, we believe our critical point viscometer is ready for development as a flight experiment.

Berg, Robert F.↗

A Novel Wastewater Treating Material: Cationic Poly Acrylamide/Diatomite Composite Flocculant

In this work, poly(methacrylatoethyl trimethyl ammonium chloride -co-acrylamide)/diatomite composite flocculant was synthesized via in situ polymerization in aqueous solution and applied in waste water treatment. The structure of composite flocculants was characterized by FT-IR, {sup 1}HNMR and XRD, TGA and viscometer. Herein, the apparent viscosity of composite flocculants was employed as comparison standard of their performance to evaluate the influence of the reaction parameters, such as monomer feeding ratio, diatomite mass fraction and polymerization temperature, etc. on their flocculation performance. And based on the above investigations, the optimum synthesis condition could be found. By comparing flocculation properties of composite flocculants with that of the conventional cationic flocculant, the dosage of composite flocculant that could make the transmittance of treated waste water exceed 95 % was only 7.5 ppm which was far lower than that of conventional flocculant (60–90 ppm). Meanwhile, the settling time was lower than 5 s which was similarly to that of conventional flocculant. Finally, the conclusion was that the composite flocculant owned higher absorption capacity and larger chain extending space than those of conventional linear flocculant due to the introduction of diatomite as backbone, which could make linear polymer chains free from entanglement and improve the flocculation capacity notably.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow Behaviour and Microstructure of a β-Glucan Concentrate

The extensional viscosity is an important rheological characteristic of polymer melts. It is however not as frequently reported on as the shear viscosity. The extensional viscosity is of special interest when considering polymeric materials for foaming and film blowing processes. Here, the extensional (and shear) viscosity along with the melt strength and the tensile properties of the corresponding solid film of a β-glucan concentrate are reported on. A capillary viscometer equipped with a hyperbolic die, yielding a contraction flow, was used to assess the extensional viscosity of the aqueous β-glucan compound at room temperature and at elevated temperatures (110 and 130 °C). In general, the extensional viscosity as well as the shear viscosity decreased with increasing deformation rate. The influence of two different amounts of added water (40 and 50%) was also examined. As expected, both types of viscosities decreased with increasing temperature. It is suggested that gelatinization of the starch fraction in the concentrate at 110 and 130 °C contributes to temperature dependence of the viscosity. To some extent, this is supported by light microscopy and confocal scanning laser microscopy studies of the microstructure of the materials. The results reported here indicate that the β-glucan concentrate might, after some modifications, be used as a complement to fossil-based polymers and processed by conventional manufacturing techniques.

36 MATERIALS SCIENCE↗

Study of Non-Newtonian Behavior of CaO-SiO{sub 2}-Based Mold Slag and Its Effect on Lubrication in Continuous Casting of Steel

To understand the effect of the non-Newtonian behavior of mold slag on lubrication during continuous casting of steel, the current study investigated the rheology of CaO-SiO{sub 2}-based mold slag using a rotational viscometer with variable rotating speed. The constitutive equations at different temperatures were determined. Subsequently, the obtained viscosity as a function of temperature and shear rate was incorporated into a validated mathematical model. The main results demonstrated that slag viscosity decreased dramatically with increased shear rate as the experimental temperature approached the break temperature of mold slag, meaning that the mold slag had a property of shear thinning. The predicted evolution of slag viscosity during mold oscillation was consistent with the shear thinning as the shear rate exerted on the slag channel varied. The calculated slag consumption was higher than that for slag treated as a Newtonian fluid, which agreed well with measurements using a miniature continuous caster. This study finds that the consideration of the non-Newtonian behavior of mold slag is significant to understand the lubrication mechanism and optimize related parameters via simulation.

36 MATERIALS SCIENCE↗