Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIDICON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Application of calibration masks to TV vidicon tube

Photographic application method devised for overlaying test pattern masks on TV camera vidicon tubes prints the mask within 0.0076 cm of the vertical and horizontal center lines of the tube face. Entire process, including mask fabrication and alignment procedure, requires less than 10 minutes.

Brawner, E. L.↗

Recent developments and applications of the SEC vidicon for astronomy

The engineering development of the SEC vidicon as an astronomical sensor has continued in parallel with its operational use. One scientific application was the six hour exposure of the quasar PHL-957 at the Coude spectrograph of the 200-inch Hale telescope. The developmental effort includes both the enhancement of the basic attributes that make the SEC an appropriate sensor, namely, high quantum efficiency, low threshold, and long integration; as well as work to broaden its scientific usefulness, such as the development of a MgF2 photocathode window for vacuum ultraviolet sensitivity, and a permanent magnet focus design for thermal compatibility with proposed large space telescopes. Additional details on the characteristics of the SEC tube are discussed, as well as plans to make a larger and higher resolution version.

Zucchino, P.↗

Performance evaluation of the two-inch return-beam vidicon three-camera subsystem.

A very-high resolution multispectral television camera system is being developed for NASA for use on the Earth Resources Technology Satellite (ERTS) program. There are three cameras in the system, each viewing the same area but operating in the blue-green, red and near-infrared spectral bands. In the laboratory the cameras' limiting resolution is 4500 TV lines over the 25 x 25-mm image format of the Return Beam Vidicon (RBV). Analysis of typical ERTS scenes shows that actual contrast ratios will be much lower than those of laboratory test targets. A model was developed to predict the resolving power performance of the RBV camera under realistic conditions. The methods used are applicable to all types of imaging systems. To verify the model, tests were conducted using the RBV camera, a laser-beam image reproducer and a series of AF tribar test patterns of known values of contrast. As a more graphic demonstration, simulated multispectral images were generated using color-IR photographs from Apollo 9.

Miller, B. P.↗

A calibration model for a stellar photometer using a SEC vidicon.

Description of a SEC vidicon response model that was used to calculate intensities of stars in the ultraviolet. The tube was used only as a stellar filter photometer. The model proposed is applicable for point sources. Experiments with both curve- or surface-fitting techniques and with extrapolation-interpolation procedures were conducted. The curve-fitting techniques were not successful, and the target gain was calculated with the aid of interpolation techniques.

Deutschman, W. A.↗

Extreme ultraviolet solar images televised in-flight with a rocket-borne SEC vidicon system.

A TV image of the entire sun while an importance 2N solar flare was in progress was recorded in the extreme ultraviolet (XUV) radiation band 171-630 A and was transmitted to ground from an Aerobee-150 rocket on Nov. 4, 1969 using S-band telemetry. The camera tube was a SEC vidicon, with its fiber optic faceplate coated with an XUV-to-visible conversion layer of p-quaterphenyl. The XUV passband was produced by three 1000-A thick aluminum filters in series together with the platinized reflecting surface of the off-axis paraboloid that imaged the sun. A number of images were recorded with integration times between 1/30 sec and 2 sec. Reconstruction of pictures was enhanced by combining several to reduce the noise.

Tousey, R.↗

Two-inch Return Beam Vidicon (RBV) multispectral three camera subsystem

A return beam vidicon multispectral three camera subsystem was developed and built as one of the two principal sensor payloads for the ERTS-A and -B missions. The performance of the cameras on ERTS-1 has been excellent, meeting or exceeding all expectations, especially in the area of geometric fidelity and stability. The three cameras are coaligned in the spacecraft to view the same square ground scene but in different spectral bands. When the separate images are processed and superimposed in their respective colors, they provide a single false color image containing the radiometric and cartographic information required for the ERTS system. The three spectral regions covered by the RBV subsystem are the blue-green red, and the near infrared. The three cameras are exposed simultaneously to facilitate registration of the three separate images into the final color composite.

Weinstein, O.↗

Astronomical observations with an SEC vidicon system.

Description of the design and operation of an SEC vidicon camera system, and review of some of the astronomical observations performed with it. Following a discussion of the main system and instrumentation features and a delineation of present and future software tasks, the preliminary series of observations obtained in conjunction with the 36-inch telescope at Kitt Peak National Observatory is briefly surveyed. These observations include (1) exposures on the Orion Nebula through various narrow-band interference filters, and (2) exposures on the galaxy Messier 82 in white light and with medium band filters.

Chiu, H.-Y.↗

High-resolution stellar vidicon spectrophotometry. I - Variable mass loss from Arcturus and the hypothesis of giant convective elements

High-resolution spectrophotometry of the variable Ca II K line in the K2 IIIp star Alpha Boo was performed with the McMath Solar Telescope at Kitt Peak National Observatory and an experimental SEC vidicon camera. The results are compared with Copernicus observations of the Mg II h and k lines and with earlier Ca II data. It is found that either of two states may typically occur in the Arcturus chromosphere. From comparison with the results of model calculations for expanding chromospheres, it is concluded that these correspond respectively to a 'normal' state in which the mass loss is less than one billionth of a solar mass per year and an 'abnormal' state in which the mass loss is about 8 billionths of a solar mass per year. In the latter case, the expansion velocity is around 13 km/s at optical depth unity in the K-line, which exceeds the local sound speed. It is suggested that the abnormal state represents the rise to the photosphere of a very large convective element, as hypothesized for red giants by Schwarzschild (1975).

Chiu, H. Y.↗

Application of the high resolution return beam vidicon

The Return Beam Vidicon (RBV) is a high-performance electronic image sensor and electrical storage component. It can accept continuous or discrete exposures. Information can be read out with a single scan or with many repetitive scans for either signal processing or display. Resolution capability is 10,000 TV lines/height, and at 100 lp/mm, performance matches or exceeds that of film, particularly with low-contrast imagery. Electronic zoom can be employed effectively for image magnification and data compression. The high performance and flexibility of the RBV permit wide application in systems for reconnaissance, scan conversion, information storage and retrieval, and automatic inspection and test. This paper summarizes the characteristics and performance parameters of the RBV and cites examples of feasible applications.

Cantella, M. J.↗

Return Beam Vidicon (RBV) panchromatic two-camera subsystem for LANDSAT-C

A two-inch Return Beam Vidicon (RBV) panchromatic two camera Subsystem, together with spare components was designed and fabricated for the LANDSAT-C Satellite; the basis for the design was the Landsat 1&2 RBV Camera System. The purpose of the RBV Subsystem is to acquire high resolution pictures of the Earth for a mapping application. Where possible, residual LANDSAT 1 and 2 equipment was utilized.

Source record↗

Silicon vidicon imaging of Jupiter - 4100- to 8300-A absolute reflectivities and limb darkening of spatially resolved regions

Jupiter was observed in six continuum wavelength channels in the region 4100-8300 A, using a silicon vidicon imaging photometer. Spectral reflectivities and high spatial resolution limb-darkening curves for several belts and zones have been extracted from the data. Simple model fits to the data yield information regarding spectral and spatial variations in single-scattering albedos and shape of particle single-scattering phase functions. Belts appear to be more backscattering than zones, particularly in the blue. The data are in moderate agreement with limb-darkening predicted by models derived from the center-to-limb variation in equivalent width of the H2 4-0 S(1) quadrupole line (Cochran, 1976) in the South Tropical Zone, but strongly disagree with the results of such models for the North Equatorial Belt.

Diner, D. J.↗

Space based topographic mapping experiment using Seasat synthetic aperture radar and LANDSAT 3 return beam vidicon imagery

A technique for producing topographic information is described which is based on same side/same time viewing using a dissimilar combination of radar imagery and photographic images. Common geographic areas viewed from similar space reference locations produce scene elevation displacements in opposite direction and proper use of this characteristic can yield the perspective information necessary for determination of base to height ratios. These base to height ratios can in turn be used to produce a topographic map. A test area covering the Harrisburg, Pennsylvania region was observed by synthetic aperture radar on the Seasat satellite and by return beam vidicon on by the LANDSAT - 3 satellite. The techniques developed for the scaling re-orientation and common registration of the two images are presented along with the topographic determination data. Topographic determination based exclusively on the images content is compared to the map information which is used as a performance calibration base.

Mader, G. L.↗

Some characteristics and advantages of LANDSAT 3 return beam vidicon images

One advantage of a LANDSAT 3 return beam vidicon (RBV) scene is the synoptic view it provides. A 1:500,000 paper print of the size 19.4 cm x 19.4 cm encompasses an area of about 3,721 square miles (9,637 sq. km.) and this compares very favorably in coverage to small scale aerial photography. A second important advantage is that the ground resolution is 38 by 38 meters. Compared to the resolution of the MSS which is 79 by 79 meters the RBV provides a wealth of detail useful for many purposes. A great variety of man made structures are visible including bridges, roads, docks, and small airfields. Agricultural field patterns are clear and settlements of various sizes can be identified and delineated. A third advantage is related to the approximate panchromatic spectral response displayed in RBV images. Since many aerial photographic interpreters are accustomed to working with panchromatic photographs, they should have no difficulty understanding and putting RBV images immediately into use.

Baker, S.↗

High resolution vidicon-based readout system for photon-counting streak camera applications

The design, implementation, and evaluation of a high-resolution vidicon-based reconfigurable imaging system for integration into a photon-counting streak camera that can be readily coupled to a standard interface and computer have been achieved. Experimental results are reported which demonstrate that the design goals are met, providing the capability to measure differential time to better than 3 picosecond accuracy. Augmented by real-time calibration, the accuracy, linearity, noise levels, and stability of the system are adequate to support dual wavelength laser ranging.

Varghese, Thomas K.↗

Vidicon intensifier

Computer-designed sensor, consisting of single-stage electrostatically-focused, triode image intensifier, provides high quality imaging characterized by exceptionally low geometric distortion, low shading, and high center-and-corner modulation transfer function.

Carpentier, R. P.↗