Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $\$$50-$\$$75/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Night ventilation control strategies in office buildings

In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factors influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of 4-Dimensional Computed Tomography-Based Ventilation Imaging to Correlate Lung Dose and Function With Clinical Outcomes

Purpose: Four-dimensional computed tomography (4DCT)-based ventilation is an emerging imaging modality that can be used in the thoracic treatment planning process. The clinical benefit of using ventilation images in radiation treatment plans remains to be tested. The purpose of the current work was to test the potential benefit of using ventilation in treatment planning by evaluating whether dose to highly ventilated regions of the lung resulted in increased incidence of clinical toxicity. Methods and Materials: Pretreatment 4DCT data were used to compute pretreatment ventilation images for 96 lung cancer patients. Ventilation images were calculated using 4DCT data, deformable image registration, and a density-change based algorithm. Dose–volume and ventilation-based dose function metrics were computed for each patient. The ability of the dose–volume and ventilation-based dose–function metrics to predict for severe (grade 3+) radiation pneumonitis was assessed using logistic regression analysis, area under the curve (AUC) metrics, and bootstrap methods. Results: A specific patient example is presented that demonstrates how incorporating ventilation-based functional information can help separate patients with and without toxicity. The logistic regression significance values were all lower for the dose–function metrics (range P=.093-.250) than for their dose–volume equivalents (range, P=.331-.580). The AUC values were all greater for the dose–function metrics (range, 0.569-0.620) than for their dose–volume equivalents (range, 0.500-0.544). Bootstrap results revealed an improvement in model fit using dose–function metrics compared to dose–volume metrics that approached significance (range, P=.118-.155). Conclusions: To our knowledge, this is the first study that attempts to correlate lung dose and 4DCT ventilation-based function to thoracic toxicity after radiation therapy. Although the results were not significant at the .05 level, our data suggests that incorporating ventilation-based functional imaging can improve prediction for radiation pneumonitis. We present an important first step toward validating the use of 4DCT-based ventilation imaging in thoracic treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-249: Correlation of Mean Lung Ventilation Value with Ratio of Total Lung Volumes

Purpose: Lung ventilation function measured from 4D-CT and from breathing correlated CT images is a novel concept to incorporate the lung physiologic function into treatment planning of radiotherapy. The calculated ventilation functions may vary from different breathing patterns, affecting evaluation of the treatment plans. The purpose of this study is to correlate the mean lung ventilation value with the ratio of the total lung volumes obtained from the relevant CTs. Methods: A ventilation map was calculated from the variations of voxel-to-voxel CT densities from two breathing phases from either 4D-CT or breathing correlated CTs. An open source image registration tool of Plastimatch was used to deform the inhale phase images to the exhale phase images. To calculate the ventilation map inside lung, the whole lung was delineated and the tissue outside the lung was masked out. With a software tool developed in house, the 3D ventilation map was then converted in the DICOM format associated with the planning CT images. The ventilation map was analyzed on a clinical workstation. To correlate ventilation map thus calculated with lung volume change, the total lung volume change was compared the mean ventilation from our method. Results: Twenty two patients who underwent stereotactic body irradiation for lung cancer was selected for this retrospective study. For this group of patients, the ratio of lung volumes for the inhale (Vin ) and exhale phase (Vex ) was shown to be linearly related to the mean of the local ventilation (Vent), Vin/Vex=1.+0.49*Vent (R2=0.93, p<0.01). Conclusion: The total lung volume change is highly correlated with the mean of local ventilation. The mean of local ventilation may be useful to assess the patient's lung capacity.

60 APPLIED LIFE SCIENCES↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-J-178: A Normalization Method Can Remove Discrepancy in Ventilation Function Due to Different Breathing Patterns

Purpose: To develop a normalization method to remove discrepancy in ventilation function due to different breathing patterns. Methods: Twenty five early stage non-small cell lung cancer patients were included in this study. For each patient, a ten phase 4D-CT and the voluntarily maximum inhale and exhale CTs were acquired clinically and retrospectively used for this study. For each patient, two ventilation maps were calculated from voxel-to-voxel CT density variations from two phases of the quiet breathing and two phases of the extreme breathing. For the quiet breathing, 0% (inhale) and 50% (exhale) phases from 4D-CT were used. An in-house tool was developed to calculate and display the ventilation maps. To enable normalization, the whole lung of each patient was evenly divided into three parts in the longitude direction at a coronal image with a maximum lung cross section. The ratio of cumulated ventilation from the top one-third region to the middle one-third region of the lung was calculated for each breathing pattern. Pearson's correlation coefficient was calculated on the ratios of the two breathing patterns for the group. Results: For each patient, the ventilation map from the quiet breathing was different from that of the extreme breathing. When the cumulative ventilation was normalized to the middle one-third of the lung region for each patient, the normalized ventilation functions from the two breathing patterns were consistent. For this group of patients, the correlation coefficient of the normalized ventilations for the two breathing patterns was 0.76 (p < 0.01), indicating a strong correlation in the ventilation function measured from the two breathing patterns. Conclusion: For each patient, the ventilation map is dependent of the breathing pattern. Using a regional normalization method, the discrepancy in ventilation function induced by the different breathing patterns thus different tidal volumes can be removed.

60 APPLIED LIFE SCIENCES↗

Building America Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts, Tyler, Texas

?Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WE-AB-202-03: Quantifying Ventilation Change Due to Radiation Therapy Using 4DCT Jacobian Calculations

Purpose: Four-dimensional computed tomography (4DCT) and image registration can be used to determine regional lung ventilation changes after radiation therapy (RT). This study aimed to determine if lung ventilation change following radiation therapy was affected by the pre-RT ventilation of the lung. Methods: 13 subjects had three 4DCT scans: two repeat scans acquired before RT and one three months after RT. Regional ventilation was computed using Jacobian determinant calculations on the registered 4DCT images. The post-RT ventilation map was divided by the pre-RT ventilation map to get a voxel-by-voxel Jacobian ratio map depicting ventilation change over the course of RT. Jacobian ratio change was compared over the range of delivered doses. The first pre-RT ventilation image was divided by the second to establish a control for Jacobian ratio change without radiation delivered. The functional change between scans was assessed using histograms of the Jacobian ratios. Results: There were significantly (p < 0.05) more voxels that had a large decrease in Jacobian ratio in the post-RT divided by pre-RT map (15.6%) than the control (13.2%). There were also significantly (p < .01) more voxels that had a large increase in Jacobian ratio (16.2%) when compared to control (13.3%). Lung regions with low function (<10% expansion by Jacobian) showed a slight linear reduction in expansion (0.2%/10 Gy delivered), while high function regions (>10% expansion) showed a greater response (1.2% reduction/10 Gy). Contiguous high function regions > 1 liter occurred in 11 of 13 subjects. Conclusion: There is a significant change in regional ventilation following a course of radiation therapy. The change in Jacobian following RT is dependent both on the delivered dose and the initial ventilation of the lung tissue: high functioning lung has greater ventilation loss for equivalent radiation doses. Substantial regions of high function lung tissue are prevalent. Research support from NIH grants CA166119 and CA166703, a gift from Roger Koch, and a Pilot Grant from University of Iowa Carver College of Medicine.

60 APPLIED LIFE SCIENCES↗

Development of a Residential Integrated Ventilation Controller

The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20%, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

30 DIRECT ENERGY CONVERSION↗

Advanced Controls for Residential Whole-House Ventilation Systems

Whole-house ventilation systems are becoming commonplace in new construction, remodeling/renovation, and weatherization projects, driven by combinations of specific requirements for indoor air quality (IAQ), health and compliance with standards, such as ASHRAE 62.2. Ventilation systems incur an energy penalty on the home via fan power used to drive the airflow, and the additional space-conditioning load associated with heating or cooling the ventilation air. Finding a balance between IAQ and energy use is important if homes are to be adequately ventilated while not increasing the energy burden. This study used computer simulations to examine RIVEC the Residential Integrated Ventilation Controller - a prototype ventilation controller that aims to deliver whole-house ventilation rates that comply with ventilation standards, for the minimum use of energy. Four different whole-house ventilation systems were simulated, both with and without RIVEC, so that the energy and IAQ results could be compared. Simulations were conducted for 13 US climate zones, three house designs, and three envelope leakage values. The results showed that the RIVEC controller could typically return ventilation energy savings greater than 40percent without compromising long-term chronic or short-term acute exposures to relevant indoor contaminants. Critical and average peak power loads were also reduced as a consequence of using RIVEC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equivalence in Ventilation and Indoor Air Quality

We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooking methods and kitchen ventilation availability, usage, perceived performance and potential in Canadian homes

Cooking is a substantial contributor to air pollutant exposures in many residences. Effective use of kitchen ventilation can mitigate exposure; however, information on its availability, usage, and potential to increase its use across the population has been limited. This study aimed to obtain nationally representative information on cooking methods, kitchen ventilation availability and usage, and the potential for education to increase effective usage. An online survey was sent to a representative sample of Canadian homes to collect data on cooking methods, the presence and use of mechanical kitchen ventilation devices, perceived device performance, and willingness to implement mitigation strategies. Responses were weighted to match key demographic factors and analyzed using non-parametric statistics. Among the 4500 respondents, 90% had mechanical ventilation devices over the cooktop (66% of which were vented to the outside), and 30% reported regularly using their devices. Devices were used most often for deep-frying, followed by stir-frying, sautéing or pan-frying, indoor grilling, boiling or steaming. Almost half reported rarely or never using their ventilation devices during baking or oven self-cleaning. Only 10% were fully satisfied with their devices. More frequent use was associated with the device being vented to the outdoors, having more than two speed settings, quiet operation if only one speed, covering over half of the cooktop, and higher perceived effectiveness. After being informed of the benefits of kitchen ventilation, 64% indicated they would consider using their devices more often, preferentially using back burners with ventilation, and/or using higher ventilation device settings when needed. This study provides population-representative data on the most used cooking methods, kitchen ventilation availability and usage, and influencing factors in Canadian homes. Such data are needed for exposure assessments and evaluating the potential to mitigate cooking-related pollutant exposures via more effective use of kitchen ventilation. The data can be reasonably extrapolated to the United States, given the similarities in residential construction practices and cultural norms between the two countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-J-87: Ventilation Weighting Effect On Mean Doses of Both Side Lungs for Patients with Advanced Stage Lung Cancer

Purpose: To study ventilation weighting effect on radiation doses to both side lungs for patients with advanced stage lung cancer. Methods: Fourteen patients with advanced stage lung cancer were included in this retrospective study. Proprietary software was developed to calculate the lung ventilation map based on 4DCT images acquired for radiation therapy. Two phases of inhale (0%) and exhale (50%) were used for the lung ventilation calculations. For each patient, the CT images were resampled to the same dose calculation resolution of 3mmx3mmx3mm. The ventilation distribution was then normalized by the mean value of the ventilation. The ventilation weighted dose was calculated by applying linearly weighted ventilation to the dose of each pixel. The lung contours were automatically delineated from patient CT image with lung window, excluding the tumor and high density tissues. For contralateral and ipsilateral lungs, the mean lung doses from the original plan and ventilation weighted mean lung doses were compared using two tail t-Test. Results: The average of mean dose was 6.1 ±3.8Gy for the contralateral lungs, and 26.2 ± 14.0Gy for the ipsilateral lungs. The average of ventilation weighted dose was 6.3± 3.8Gy for the contralateral lungs and 24.6 ± 13.1Gy for the ipsilateral lungs. The statistics analysis shows the significance of the mean dose increase (p<0.015) for the contralateral lungs and decrease (p<0.005) for the ipsilateral lungs. Conclusion: Ventilation weighted doses were greater than the un-weighted doses for contralateral lungs and smaller for ipsilateral lungs. This Result may be helpful to understand the radiation dosimetric effect on the lung function and provide planning guidance for patients with advance stage lung cancer.

60 APPLIED LIFE SCIENCES↗

Significant Improvements in Pyranometer Nighttime Offsets Using High-Flow DC Ventilation

Abstract Ventilators are used to keep the domes of pyranometers clean and dry, but they affect the nighttime offset as well. This paper examines different ventilation strategies. For the several commercial single-black-detector pyranometers with ventilators examined here, high-flow-rate [50 cubic feet per minute (CFM) and higher] 12-VDC (where VDC refers to voltage direct current) fans lower the offsets, lower the scatter, and improve the predictability of the offsets during the night compared with lower-flow-rate (35 CFM) 120-VAC (where VAC refers to voltage alternating current) fans operated in the same ventilator housings. Black-and-white pyranometers sometimes show improvement with DC ventilation, but in some cases DC ventilation makes the offsets slightly worse. Since the offsets for these black-and-white pyranometers are always small, usually no more than 1 W m−2, whether AC or DC ventilated, changing their ventilation to higher CFM DC ventilation is not imperative. Future work should include all major manufacturers of pyranometers and unventilated and ventilated pyranometers. An important outcome of future research will be to clarify under what circumstances nighttime data can be used to predict daytime offsets.

14 SOLAR ENERGY↗

Potential model for single-sided naturally ventilated buildings in China

The paper investigates a single-sided naturally ventilated buildings potential model considering number of factors in China. This model can be used to estimate potential of natural ventilation via local climate data and building parameters. The main goal of the model is to predict natural ventilation hours and hourly ventilation flow rate. In fluid model, formula of single-sided natural ventilation by coupling wind pressure and temperature difference was used to calculate air flow rate. Accordingly, the paper analyzed four typical cities in different climate region in China and calculated pressure difference Pascal hours (PDPH). The results show that single-sided ventilation has fewer adaptive comfort hours than two-sided ventilation and much less ventilation volume. This model provided quantitative information for early stage architectural natural ventilation design and building energy efficiency evaluation. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗