Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VALVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.

Armijo, Kenneth (ORCID:0000000346832147)↗

Statistical Performance Evaluation Of Soft Seat Pressure Relief Valves

Risk-based inspection methods enable estimation of the probability of failure on demand for spring-operated pressure relief valves at the United States Department of Energy's Savannah River Site in Aiken, South Carolina. This paper presents a statistical performance evaluation of soft seat spring operated pressure relief valves. These pressure relief valves are typically smaller and of lower cost than hard seat (metal to metal) pressure relief valves and can provide substantial cost savings in fluid service applications (air, gas, liquid, and steam) providing that probability of failure on demand (the probability that the pressure relief valve fails to perform its intended safety function during a potentially dangerous over pressurization) is at least as good as that for hard seat valves. The research in this paper shows that the proportion of soft seat spring operated pressure relief valves failing is the same or less than that of hard seat valves, and that for failed valves, soft seat valves typically have failure ratios of proof test pressure to set pressure less than that of hard seat valves.

42 ENGINEERING↗

Assessment on the Practicality of Off-the-Shelf Valves for Use in Molten Salt

From the mid to late 1960s, the Molten Salt Reactor Experiment (MSRE) was operated at Oak Ridge National Laboratory (ORNL). The MSRE design is unique: instead of standard valves, freeze valves were used to isolate the fluid salt as needed. While standard valves were considered for use in the MSRE, key design challenges (leaking, corrosion, valve alignment, and cold-welding, etc.) were all avoided by choosing a freeze type valve. While the freeze valves were integral to the MSRE’s success, they do not respond quickly, and they are not capable of throttling flow: two key features important to commercial operation and test facilities. More than half a century after the MSRE’s inception, design and manufacturing capabilities have changed. There is a renewed interest in molten salts for energy storage in nuclear and concentrated solar power. Therefore, there is a strong desire to have a functioning valve that can be obtained off the shelf or with minimal modification to a custom valve. This research addresses the known challenges associated with valve selection in fluoride salts, provides guidelines as to potential options for selection of a valve, and uses these guidelines to select a valve for testing in ORNL’s Liquid Salt Test Loop (LSTL).

Howard, Trevor↗

Multi-channel pulsed valve inlet system and method

A multichannel inlet system for a mass spectrometer includes a plurality of valve assemblies coupled to a manifold, and a pulsed valve driver. The manifold is configured to be connected in fluid connection with an ion trap of the mass spectrometer. Each valve assembly includes a valve and an injection port operably coupled to receive the reagent. The valve has an actuated state in which the valve provides fluid communication between the injection port and the manifold, and an unactuated state in which the valve substantially prevents fluid communication between the injection port and the manifold. The pulsed valve driver is operably connected to receive a pulse signal sequence from a processor, and is configured to generate pulsed valve drive signals for one or more of the valves based on the pulse signal sequence to cause a corresponding one of the valves to be in the actuated state.

Kenttamaa, Hilkka↗

Characterization of small microfluidic valves for studies of mechanical properties of bacteria

Lab-on-a-chip platforms present many new opportunities to study bacterial cells and cellular assemblies. Here, the authors describe a new platform that allows us to apply uniaxial stress to individual bacterial cells while observing the cell and its subcellular assemblies using a high resolution optical microscope. The microfluidic chip consists of arrays of miniature pressure actuated valves. By placing a bacterium under one of such valves and partially closing the valve by externally applied pressure, the cell can be deformed. Although large pressure actuated valves used in integrated fluidic circuits have been extensively studied previously, here the authors downsize those microfluidic valves and use flow channels with rectangular cross-sections to maintain the bacteria in contact with cell culture medium during the experiments. The closure of these valves has not been characterized before. First, these valves are modeled using finite element analysis, and then compared the modeling results with the actual closing profiles of the valves, which is determined from absorption measurements. The measurements and modeling show with good agreement that the deflection of valves is a linear function of externally applied pressure and the deflection scales proportionally to the width of the flow channel. In addition to characterizing the valve, the authors show at a proof-of-principle level that it can be used to deform a bacterial cell at considerable magnitude. They found the largest deformations in 5 μm wide channels where the bacterial width and length increase by 1.6 and 1.25 times, respectively. Narrower and broader channels are less optimal for these studies. Finally, the platform presents a promising approach to probe, in a quantitative and systematic way, the mechanical properties of not only bacterial cells but possibly also yeast and other single-celled organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Mesofluidic two stage digital valve

A mesofluidic scale digital valve system includes a first mesofluidic scale valve having a valve body including a bore, wherein the valve body is configured to cooperate with a solenoid disposed substantially adjacent to the valve body to translate a poppet carried within the bore. The mesofluidic scale digital valve system also includes a second mesofluidic scale valve disposed substantially perpendicular to the first mesofluidic scale valve. The mesofluidic scale digital valve system further includes a control element in communication with the solenoid, wherein the control element is configured to maintain the solenoid in an energized state for a fixed period of time to provide a desired flow rate through an orifice of the second mesofluidic valve.

42 ENGINEERING↗

Excess flow shutoff valve

Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

42 ENGINEERING↗

Debris tolerant valve

A valve includes a valve body, a sleeve within the valve body and a rotatable valve element that has one portion within the sleeve to control flow of media through the valve and another portion extending from the valve body and coupled to an actuator that rotates the valve element. The valve element is rotatable to a first position to flow media to one port and to a second position to flow media to another port. The sleeve has a pair of side openings. Each side opening has an angled perimetrical edge and is aligned with a corresponding port member. A half dovetail shaped groove is formed by the angled perimetrical edge of each side opening, the corresponding port and the valve body. A seal is lodged within each groove to form a seal that exhibits reduced unswept volume and which wipes debris off the valve element as it rotates.

42 ENGINEERING↗

Fluid–Structure Interaction Analysis of Papillary Muscle Forces Using a Comprehensive Mitral Valve Model with 3D Chordal Structure

Numerical models of native heart valves are being used to study valve biomechanics to aid design and development of repair procedures and replacement devices. These models have evolved from simple two-dimensional approximations to complex three-dimensional, fully coupled fluid-structure interaction (FSI) systems. Such simulations are useful for predicting the mechanical and hemodynamic loading on implanted valve devices. A current challenge for improving the accuracy of these predictions is choosing and implementing modeling boundary conditions. In order to address this challenge, we are utilizing an advanced in-vitro system to validate FSI conditions for the mitral valve system. Explanted ovine mitral valves were mounted in an in vitro setup, and structural data for the mitral valve was acquired with *CT. Experimental data from the in-vitro ovine mitral valve system were used to validate the computational model. As the valve closes, the hemodynamic data, high speed lea et dynamics, and force vectors from the in-vitro system were compared to the results of the FSI simulation computational model. The total force of 2.6 N per papillary muscle is matched by the computational model. In vitro and in vivo force measurements are important in validating and adjusting material parameters in computational models. The simulations can then be used to answer questions that are otherwise not possible to investigate experimentally. This work is important to maximize the validity of computational models of not just the mitral valve, but any biomechanical aspect using computational simulation in designing medical devices.

Comprehensive Computational Model↗

Effect of the mitral valve on diastolic flow patterns

The leaflets of the mitral valve interact with the mitral jet and significantly impact diastolic flow patterns, but the effect of mitral valve morphology and kinematics on diastolic flow and its implications for left ventricular function have not been clearly delineated. In the present study, we employ computational hemodynamic simulations to understand the effect of mitral valve leaflets on diastolic flow. A computational model of the left ventricle is constructed based on a high-resolution contrast computed-tomography scan, and a physiological inspired model of the mitral valve leaflets is synthesized from morphological and echocardiographic data. Simulations are performed with a diode type valve model as well as the physiological mitral valve model in order to delineate the effect of mitral-valve leaflets on the intraventricular flow. The study suggests that a normal physiological mitral valve promotes the formation of a circulatory (or “looped”) flow pattern in the ventricle. The mitral valve leaflets also increase the strength of the apical flow, thereby enhancing apical washout and mixing of ventricular blood. The implications of these findings on ventricular function as well as ventricular flow models are discussed.

42 ENGINEERING↗

Engine including hydraulically actuated valvetrain and method of valve overlap control

An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

42 ENGINEERING↗

Pilot-pressure-controlled flow valve and fluid system containing same

In a thermal fluid system, a control valve includes a flow valve and a solenoid pilot valve. The flow valve has an inlet and an outlet; a control chamber for receiving a pilot pressure; and a valve member operable by the pilot pressure to selectively open and close a fluid path from the inlet to the outlet. The pilot pressure acts in a closing direction of the flow valve. The pilot valve provides the pilot pressure to the control chamber and is a 3/2 way valve with a first port in fluid communication with the control chamber, a second port to be connected to a pressure source, and a third port. The pilot valve has a first position connecting the first port with the second port and a second position connecting the first port with the third port.

Chowdhury, Sourav↗

Final CRADA Report for Enhanced and Miniaturized Wireless Valve Position Indicator Prototype

Most operating nuclear power plants (NPPs) in the United States have received approval to extend their operating licenses to 60 years. Now the nuclear industry is preparing to extend operating licenses to 80 years. While NPPs are preparing for extensions (60 years and beyond), the nuclear industry is facing a unique economic sustainability challenge in the current energy market. According to the Nuclear Energy Institute (NEI), generating costs of U.S. reactors have risen by 28% over the last 12 years, which is impacting the competitiveness of nuclear power in a market being increasingly penetrated by natural gas and renewable energy. This is partly because of the fact that the present nuclear work practice is dependent on a large technical staff which results in high operation and maintenance (O&M) costs, accounting for approximately 66% of the total operating cost. To address these concerns and abide by the NEI’s “Delivering the Nuclear Promise Initiative,” the U.S. utilities are embracing digitalization of their work practice to lower the O&M costs and increase productivity and efficiency while maintaining a safe and reliable operation. To address these above-mentioned concerns, Idaho National Laboratory (INL) researchers (proposal team) have developed a wireless valve position indication (VPI) sensor system that can be retrofitted on three main manual valve types (extendible to other manual valve types) to replace manual valve position verification with digital verification and enable online monitoring of manual valves. The developed technology 1) is evaluated for electromagnetic interference, 2) has a low power consuming and miniaturized electronic board, 3) is mounted on adjustable and reconfigurable sensor mounting unit that can fit on an actual flow-loop (at Idaho State University-ISU) to enable online monitoring of manual valve types without any valve body modification, and 4) ensures robust, secure, and reliable real-time communication of manual valve position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary characterization of active MEMS valves.

Partial characterization of a series of electrostatically actuated active microfluidic valves is to be performed. Tests are performed on a series of 24 valves from two different MEMS sets. Focus is on the physical deformation of the structures under variable pressure loadings, as well as voltage levels. Other issues that inhibit proper performance of the valves are observed, addressed and documented as well. Many microfluidic applications have need for the distribution of gases at finely specified pressures and times. To this end a series of electrostatically actuated active valves have been fabricated. Eight separate silicon die are discussed, each with a series of four active valves present. The devices are designed such that the valve boss is held at a ground, with a voltage applied to lower contacts. Resulting electrostatic forces pull the boss down against a series of stops, intended to create a seal as well as prevent accidental shorting of the device. They have been uniquely packaged atop a stack of material layers, which have inlaid channels for application of fluid flow to the backside of the valve. Electrical contact is supplied from the underlying printed circuit board, attached to external supplies and along traces on the silicon. Pressure is supplied from a reservoir of house compressed air, up to 100 Psig. This is routed through a Norgren R07-200-RGKA pressure regulator, rated to 150 Psig. From there flow passes a manually operated ball valve, and to a flow meter. Two flow meters were utilized; initially an Omega FMA1802 rated at 10 sccm, and followed by a Flocat model for higher flow rates up to 100 sccm. An Omega DPG4000-500 pressure gauge produced pressure measurements. Optical measurements were returned via a WYKO Interferometry probe station. This would allow for determination of physical deformations of the device under a variety of voltage and pressure loads. This knowledge could lead to insight as to the failure mechanisms of the device, yielding improvements for subsequent fabrications.

47 OTHER INSTRUMENTATION↗

Evaluating All-Metal Valves for Use in a Tritium Environment

In the tritium gas processing system, it is desired to minimize polymer components due to their degradation from tritium exposure (beta decay). One source of polymers in the tritium process is valve components. A vendor has been identified that manufactures a valve that is marketed as being made from all-metal construction. This manufacturer, Ham-Let Group, manufactures a diaphragm valve (3LE series) that claims to be made entirely of metal. SRNL procured twelve (12) Ham-Let diaphragm valves for characterization and evaluation. The characterization tests include identification of the maximum pressure of these valves by performing pressure and burst tests. Leak tests were performed to ensure the valves do not exceed the acceptable leak rate for tritium service. These valves were then cycled in a nitrogen gas and/or vacuum environment to ensure they would be durable in a process environment. They were subsequently leak tested per ASTM protocol to ensure that the valves maintained their leak tight integrity. A detailed material analysis was also conducted to determine hydrogen and tritium compatibility.

36 MATERIALS SCIENCE↗

Metal Bellows Valve Reliability Testing - Copper Stem Tip Testing

SRNL was funded in Mid-Year FY20 by NNSA NA-231 to continue evaluation of alternate valves for use in tritium service to support domestic Mo-99 production. The focus of the effort was to identify valve cycle life as a function of actuator size and stem tip material. Using the minimum size actuator to reliability open and close valves can reduce glovebox size and thus support domestic companies to “come to market” faster in supplying Mo-99 to the US market. This report serves as a continuation to the FY19 report and summarizes the task activities completed in FY20 after authorization to start work was obtained on May 5 th , 2020. Copper stem tips were tested on the Swagelok 1C and 5C actuated metal bellows valves. With ambitions to cycle each set 150,000 times, both 1C and 5C valves were met with high failure rates. The smaller 1C actuated valves required additional closing pressure to form a seal with the Cu stem tips installed however, excessive stem tip deformation may be the root cause of the majority of the valves failing before 500 cycles. The larger 5C actuated valves were cycled 150,000 times but still resulted in 80% failure rate, suspected of metal fatigue in the bellows due to high cycling frequencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Compression-Ratio; Atkinson-Cycle Engine Using Low-Pressure Direct Injection and Pneumatic-Electronic Valve Actuation Enabled by Ionization Current and Foward-Backward Mass Air Flow Sensor Feedback

This report describes the work completed over a two and one half year effort sponsored by the US Department of Energy. The goal was to demonstrate the technology needed to produce a highly efficient engine enabled by several technologies which were to be developed in the course of the work. The technologies included: (1) A low-pressure direct injection system; (2) A mass air flow sensor which would measure the net airflow into the engine on a per cycle basis; (3) A feedback control system enabled by measuring ionization current signals from the spark plug gap; and (4) An infinitely variable cam actuation system based on a pneumatic-hydraulic valve actuation These developments were supplemented by the use of advanced large eddy simulations as well as evaluations of fuel air mixing using the KIVA and WAVE models. The simulations were accompanied by experimental verification when possible. In this effort a solid base has been established for continued development of the advanced engine concepts originally proposed. Due to problems with the valve actuation system a complete demonstration of the engine concept originally proposed was not possible. Some of the highlights that were accomplished during this effort are: (1) A forward-backward mass air flow sensor has been developed and a patent application for the device has been submitted. We are optimistic that this technology will have a particular application in variable valve timing direct injection systems for IC engines. (2) The biggest effort on this project has involved the development of the pneumatic-hydraulic valve actuation system. This system was originally purchased from Cargine, a Swedish supplier and is in the development stage. To date we have not been able to use the actuators to control the exhaust valves, although the actuators have been successfully employed to control the intake valves. The reason for this is the additional complication associated with variable back pressure on the exhaust valves when they are opened. As a result of this effort, we have devised a new design and have filed for a patent on a method of control which is believed to overcome this problem. The engine we have been working with originally had a single camshaft which controlled both the intake and exhaust valves. Single cycle lift and timing control was demonstrated with this system. (3) Large eddy simulations and KIVA based simulations were used in conjunction with flow visualizations in an optical engine to study fuel air mixing. During this effort we have devised a metric for quantifying fuel distribution and it is described in several of our papers. (4) A control system has been developed to enable us to test the benefits of the various technologies. This system used is based on Opal-RT hardware and is being used in a current DOE sponsored program.

33 ADVANCED PROPULSION SYSTEMS↗

Control Valve

A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

42 ENGINEERING↗