Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Unknown Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Shock-induced fine-grained recrystallization of olivine - Evidence against subsolidus reduction of Fe/2+/

Electron spin resonance (ESR) studies have been carried out on three single grains of terrestrial olivine (Fo90) shock loaded along the 010 line to peak pressures of 280, 330, and 440 kbar. The results indicate that neither metallic Fe similar to that observed in returned lunar soils nor paramagnetic Fe(3+) caused by oxidation of Fe(2+) has been produced in these shock experiments. Trace amounts of Mn (2+) have been detected in both shocked and unshocked olivine. The ESR signals of Mn(2+) show spectral features which are found to correlate with the degree of shock-induced recrystallization observed petrographically. The increasing mass fraction of recrystallized olivine correlates with increasing shock pressures. This phenomenon is modelled assuming it results from the progressive effect of the shock-induced transformation of the olivine to a yet unknown high-pressure phase and its subsequent reversion to the low-pressure olivine phase. The mass fraction of recrystallized material is predicted to be nearly linear with shock pressure.

Ahrens, T. J.↗

Assessing Reliability of NDE Flaw Detection Using Smaller Number of Demonstration Data Points

The paper provides an engineering analysis approach for assessing reliability of NDE flaw detection using smaller number of demonstration data points. It explores dependence of probability of detection (POD), probability of false positive (POF), on contrast-to-noise ratio, and net decision threshold-to-noise ratio in a simulated data; and draws some generically applicable inferences to devise the approach. ASTM nondestructive evaluation standards provide requirements on signal-to-noise ratio and/or contrast-to-noise ratio in order to provide reliable flaw detection and limit false positive calls. POD analysis of inspection test data results in an estimated flaw size, denoted by 𝑎90/95. This flaw size has 90% POD and minimum 95% confidence. POF is also estimated in the analysis. POD demonstration requires specimens with flaws of known size. In many situations, it is very expensive to produce the large number of flaws required for the POD analysis. In some situations, only real flaws can truly represent the flaws for demonstration. Real flaws of correct size and location in part configuration specimen may be difficult to produce, if not impossible. Here, an engineering analysis approach is devised using simulation to assess reliability of NDE technique when a limited number of flaws are available for demonstration. In this simulation, a technique is considered reliable, if it provides flaw detectability size equal to or better than the theoretical 𝑎90𝑡ℎ used in simulation and also provides a POF less than or equal to a chosen value. The paper uses simulated signal response versus flaw size data to devise the approach. Linear correlation is used between the signal response data and flaw size. POD software mh1823 uses generalized linear model (GLM) in POD analysis after transforming the flaw size and signal response, if needed, using logarithm. Therefore, this approach is in agreement with the linear signal correlation used in mh1823. Using the POD analysis of data, generic conditions on contrast-to-noise ratio and net decision threshold-to-noise ratio are derived for reliable flaw detection. In order to assess technique reliability using the engineering approach, signal response-to-flaw size correlation about the flaw size of concern is needed. In addition, measurement of noise is also needed. If the technique meets the above requirements, assumption of linear signal-to-flaw size correlation and conditions on noise, then the technique can be assessed using this analysis as it fits the underlying POD model used here. The approach is conservative and is designed to provide a larger flaw size compared to the POD approach. Such NDE technique assessment approach, although, not as rigorous as POD, can be cost effective if the larger flaw size can be tolerated. Typically, this is a situation for all quality control NDE inspections. Here, an NDE technique needs to be reliable and 𝑎90/95 is not estimated, but the assessed flaw size is assumed to be larger than the unknown a90 due to conservative factors or margins. Applicability of the approach for assessing reliability of flaw detection in x-ray radiography and 2D imaging in general is also explored.

Koshti, Ajay M.↗

Numerical Simulation of Infrasound Resonance in Underground Tunnel Structures

Remote observation of infrasound resonant signals emanating from underground tunnel structures could potentially allow the remote quantification of the geometry of the underground structures in which the signals were generated. However, the sensitivity of these observations to tunnel geometry and changes in that geometry are unknown. In this report we outline a numerical simulation study with the following three objectives: 1. Can we model infrasound resonance using numerical simulations? 2. What is the sensitivity of the modeled observations to changes in tunnel geometry or boundary conditions? And 3. Can we accurately model resonant observations of explosions occurring in Redmond Salt Mine in Central Utah. In this report we outline affirmative answers to the first two objectives, but we were unable to accurately model the Redmond Explosions due to numerical instability in the model of the complex structure of the mine. Recommendations for future work emphasize the need to acquire additional datasets and to explore a more data-based approach in which changes in data signatures are detected as a first step towards developing a method which inverts resonant infrasound signals for tunnel geometry.

47 OTHER INSTRUMENTATION↗

Gravitational Wave Sources as Timing References for LISA Data

In the megahertz gravitational-wave band, galactic ultra-compact binaries (UCBs) are continuous sources emitting at near-constant frequency. The signals from many of these galactic binaries will be sufficiently strong to be detectable by the Laser Interferometer Space Antenna (LISA) after approximately Omicron (1 week) of observing. In addition to their astrophysical value, these UCBs can be used to monitor the data quality of the observatory. This paper demonstrates the capabilities of galactic UCBs to be used as calibration sources for LISA by demanding signal coherence between adjacent week-long data segments separated by a gap in time of a priori unknown duration. A parameter for the gap duration is added to the UCB waveform model and used in a Markov-chain Monte Carlo algorithm simultaneously fitting for the astrophysical source parameters. Results from measurements of several UCBs are combined to produce a joint posterior on the gap duration. The measurement accuracy's dependence on how much is known about the UCBs through prior observing, and seasonal variations due to the LISA orbital motion, is quantified. The duration of data gaps in a two-week segment of data can be constrained to within approximately 0.2 s using Omicron (10) UCBs after one month of observing. The timing accuracy from UCBs improves to approximately or less than o.1 s after 1 year of mission operations. These results are robust to within a factor of approximately 2 when taking into account seasonal variations.

Gravitation Wave Sources↗

Heterodyne method for high specificity gas detection.

This paper describes a new technique for measuring trace quantities of gases. The technique involves the use of a reference cell (containing a known amount of the gas being sought) and a sample cell (containing an unknown amount of the same gas) wherein the gas densities are modulated. Light passing through the two cells in sequence is modulated in intensity at the vibrational-rotational lines characteristic of the absorption spectrum for the gas of interest. Since the absorption process is nonlinear, modulating the two absorption cells at two different frequencies gives rise to a heterodyning effect, which in turn introduces sum and difference frequencies in the detected signal. Measuring the ratio of the difference frequency signal for example, to the signal introduced by the reference cell provides a normalized measure of the amount of the gas in the sample cell. The readings produced are thereby independent of source intensity, window transparency, and detector sensitivity. Experimental evaluation of the technique suggests that it should be applicable to a wide range of gases, that it should be able to reject spurious signals due to unwanted gases, and that it should be sensitive to concentrations of the order of 10 to the minus 8th power when used with a sample cell of only 20 cm length.

Dimeff, J.↗

Carrier Estimation Using Classic Spectral Estimation Techniques for the Proposed Demand Assignment Multiple Access Service

In any satellite communication, the Doppler shift associated with the satellite's position and velocity must be calculated in order to determine the carrier frequency. If the satellite state vector is unknown then some estimate must be formed of the Doppler-shifted carrier frequency. One elementary technique is to examine the signal spectrum and base the estimate on the dominant spectral component. If, however, the carrier is spread (as in most satellite communications) this technique may fail unless the chip rate-to-data rate ratio (processing gain) associated with the carrier is small. In this case, there may be enough spectral energy to allow peak detection against a noise background. In this thesis, we present a method to estimate the frequency (without knowledge of the Doppler shift) of a spread-spectrum carrier assuming a small processing gain and binary-phase shift keying (BPSK) modulation. Our method relies on an averaged discrete Fourier transform along with peak detection on spectral match filtered data. We provide theory and simulation results indicating the accuracy of this method. In addition, we will describe an all-digital hardware design based around a Motorola DSP56303 and high-speed A/D which implements this technique in real-time. The hardware design is to be used in NMSU's implementation of NASA's demand assignment, multiple access (DAMA) service.

Scaife, Bradley James↗

Ultraviolet Spectropolarimetry: on the Origin of Rapidly Rotating B Stars

UV spectroscopy and spectropolarimetry hold the key to understanding certain aspects of massive stars that are largely inaccessible (or exceptionally difficult) with optical or longer wavelength observations. As we demonstrate, this is especially true for the rapidly-rotating Be and Bn stars, owing to their high temperatures, geometric asymmetries, binary properties, evolutionary history, as well as mass ejection and disks (in the case of Be stars). UV spectropolarimetric observations are extremely sensitive to the photospheric consequences of rapid rotation (i.e. oblateness, temperature, and surface gravity gradients), far beyond the reach of optical wavelengths. Our polarized radiative-transfer modelling predicts that with low-resolution UV spectropolarimetry covering 120–300 nm, and with a reasonable SNR, the inclination angle of a rapid rotator can be determined to within 5 degrees, and the rotation rate to within 1%. The origin of rapid rotation in Be/n stars can be explained by either single-star or binary evolution, but their relative importance is largely unknown. Some Be stars have hot sub-luminous (sdO) companions, which at an earlier phase transferred their envelope (and with it mass and angular momentum) to the present-day rapid rotator. Although sdO stars are small and relatively faint, their flux peaks in the UV making this the optimal observational wavelength regime. Through spectral modelling of a wide range of simulated Be/n+sdO configurations, we demonstrate that high-resolution high-signal-to-noise ratio UV spectroscopy can detect an sdO star even when ∼1,000 times fainter in the UV than its Be/n star companion. This degree of sensitivity is needed to more fully explore the parameter space of Be/n+sdO binaries, which so far has been limited to about a dozen systems with relatively luminous sdO stars. We suggest that a UV spectropolarimetric survey of Be/n stars is the next step forward in understanding this population. Such a dataset would, when combined with population synthesis models, allow for the determination of the relative importance of the possible evolutionary pathways traversed by these stars, which is also crucial for understanding their future evolution and fate.

Ultraviolet astronomy↗

The Atacama Cosmology Telescope: Cosmology from Galaxy Clusters Detected Via the Sunyaev-Zel'dovich Effect

We present constraints on cosmological parameters based on a sample of Sunyaev-Zel'dovich-selected galaxy clusters detected in a millimeter-wave survey by the Atacama Cosmology Telescope. The cluster sample used in this analysis consists of 9 optically-confirmed high-mass clusters comprising the high-significance end of the total cluster sample identified in 455 square degrees of sky surveyed during 2008 at 148 GHz. We focus on the most massive systems to reduce the degeneracy between unknown cluster astrophysics and cosmology derived from SZ surveys. We describe the scaling relation between cluster mass and SZ signal with a 4-parameter fit. Marginalizing over the values of the parameters in this fit with conservative priors gives (sigma)8 = 0.851 +/- 0.115 and w = -1.14 +/- 0.35 for a spatially-flat wCDM cosmological model with WMAP 7-year priors on cosmological parameters. This gives a modest improvement in statistical uncertainty over WMAP 7-year constraints alone. Fixing the scaling relation between cluster mass and SZ signal to a fiducial relation obtained from numerical simulations and calibrated by X-ray observations, we find (sigma)8 + 0.821 +/- 0.044 and w = -1.05 +/- 0.20. These results are consistent with constraints from WMAP 7 plus baryon acoustic oscillations plus type Ia supernova which give (sigma)8 = 0.802 +/- 0.038 and w = -0.98 +/- 0.053. A stacking analysis of the clusters in this sample compared to clusters simulated assuming the fiducial model also shows good agreement. These results suggest that, given the sample of clusters used here, both the astrophysics of massive clusters and the cosmological parameters derived from them are broadly consistent with current models.

Sehgal, Neelima↗

Method and apparatus for frequency spectrum analysis

A method for frequency spectrum analysis of an unknown signal in real-time is discussed. The method is based upon integration of 1-bit samples of signal voltage amplitude corresponding to sine or cosine phases of a controlled center frequency clock which is changed after each integration interval to sweep the frequency range of interest in steps. Integration of samples during each interval is carried out over a number of cycles of the center frequency clock spanning a number of cycles of an input signal to be analyzed. The invention may be used to detect the frequency of at least two signals simultaneously. By using a reference signal of known frequency and voltage amplitude (added to the two signals for parallel processing in the same way, but in a different channel with a sampling at the known frequency and phases of the reference signal), the absolute voltage amplitude of the other two signals may be determined by squaring the sine and cosine integrals of each channel and summing the squares to obtain relative power measurements in all three channels and, from the known voltage amplitude of the reference signal, obtaining an absolute voltage measurement for the other two signals by multiplying the known voltage of the reference signal with the ratio of the relative power of each of the other two signals to the relative power of the reference signal.

Cole, Steven W.↗

Structural basis for saxitoxin congener binding and neutralization by anuran saxiphilins

Dinoflagellates and cyanobacteria produce saxitoxin (STX) and ~50 congeners that disrupt bioelectrical signals by blocking voltage-gated sodium channels (NaVs). Consuming seafood carrying these toxins causes paralytic shellfish poisoning (PSP). Although NaVs and anuran STX binding proteins (saxiphilins, Sxphs) use convergent STX binding modes, the structural basis for STX congener recognition is unknown. Here, we show that American bullfrog (Rana catesbeiana) RcSxph and High Himalaya frog (Nanorana parkeri) NpSxph sequester STX congeners using a ‘lock and key’ mode shared with STX. Importantly, functional studies demonstrate that Sxph ‘toxin sponges’ reverse NaV block by multiple STX congeners and detect these toxins in a radioligand binding assay (RBA) used for environmental testing. Together, our study establishes how Sxphs sequester select neurotoxins and uncover STX congener-specific interactions distinct from NaVs. These findings expand understanding of toxin sponge action and provide a foundation for strategies to monitor and mitigate the harmful effects of STX congeners.

Zakrzewska, Sandra↗

Identification of the Ga interstitial in Al(x)Ga(1-x)As by optically detected magnetic resonance

A new optically detected magnetic resonance spectrum in Al(x)Ga(1-x)As is reported and assigned to native Ga interstitials. Luminescence-quenching signals were observed over the energy region from 0.75 to 1.1 eV. The optically detected magnetic resonance is nearly isotropic, with spin-Hamiltonian parameters g = 2.025 + or - 0.006, central hyperfine splitting A(Ga-69) = 0.050 + or - 0.001/cm, and A(Ga-71) = 0.064 + or - 0.001/cm for H near the 001 line. The strong hyperfine coupling denotes an electronic state of A1 symmetry, which current theories predict for the Ga interstitial but not the Ga antisite. The slight anisotropy probably indicates that the Ga(i) is paired with a second, unknown defect.

Kennedy, T. A.↗

A Saturn launched X-ray astronomy experiment. Volume 2: S-150

In order to develop an experiment which would provide previously unknown information at the projected new launch period, a decision was made to modify the S-027 experiment to allow detection of lower energies which had previously not been mapped. The modification basically required that the static counters be replaced with a thin film entrance window gas flow counter which would allow detection of X-ray energies as low as 150 ev. The new experiment designated S-150 was designed to detect X-ray energies over a spectrum of 150 ev to 10 Kev. Photographs of the S-150 experiment are shown. Basically the same signal detection and processing techniques were used on the S-150 experiment as were used on the S-027. For economic reasons much of the S-027 subassembly hardware was used on the new experiment. The main design changes were in the signal detection system and the high energy veto system.

Source record↗

Stark effect spectrophone for continuous absorption spectra monitoring

A Stark effect spectrophone using a pulsed or continuous wave laser having a beam with one or more absorption lines of a constituent of an unknown gas is described. The laser beam is directed through windows of a closed cell while the unknown gas to be modified flows continuously through the cell between electric field plates disposed in the cell on opposite sides of the beam path through the cell. When the beam is pulsed, energy absorbed by the gas increases at each point along the beam path according to the spectral lines of the constituents of the gas for the particular field strengths at those points. The pressure measurement at each point during each pulse of energy yields a plot of absorption as a function of electric field for simultaneous detection of the gas constituents. Provision for signal averaging and modulation is included.

Kavaya, M. J.↗

Spectroscopic CCD surveys for quasars at large redshift. 3: The Palomar Transit Grism Survey catalog

This paper reports the initial results of the Palomar Transit Grism Survey (PTGS). The PTGS was designed to produce a sample of z greater than 2.7 quasars that were identified by well-defined selection criteria. The survey consists of six narrow (approximately equal to 8.5 min wide) strips of sky; the total effective area is 61.47 sq deg. Low-resolution slitless spectra, covering the wavelength range from 4400 to 7500 A, were obtained for approximately 600 000 objects. The wavelength- and flux-calibrated spectra were searched for emission lines with an automatic software algorithm. A total to 1655 emission features in the grism data satisfied our signal-to-noise ratio and equivalent width selection criteria; subsequent slit spectroscopy of the candidates confirmed the existence of 1052 lines (928 different objects). Six groups of emission lines were detected in the survey: Lyman alpha + N V, C IV, C III1, Mg II, H Beta + (O III), and H alpha + (S II). More than two-thirds of the candidates are low-redshift (z less than 0.45) emission-line galaxies; ninety objects are high-redshift quasars (z greater than 2.7) detected via their Lyman alpha + N V emission lines. The survey contains three previously unknown quasars brighter than 17th magnitude; all three have redshifts of approximately equal to 1.3. In this paper we present the observational properties of the survey, the algorithms used to select the emission-line candidates, and the catalog of emission-line objects.

Schneider, Donald P.↗

Exploiting Multi-Domain Features for Detection of Unclassified Electromagnetic Signals

Deep Learning based classification techniques have shown excellent performance in static environments, where the training and testing samples are drawn from the same distribution. However, real world scenarios often present samples that do not belong to the known set of classes chosen during training. This is quite common for electromagnetic signals, where it is impractical to assume that all possible waveforms are known a-priori, specially in scenarios like warfare. To address this problem, we propose a deep learning based adversarial model where the generator learns to generate waveform features that can deceive the discriminator model as true samples. We introduce domain knowledge of wireless signals by decomposing the signal into a lower dimensional unique feature set, which is used for classifying known versus unknown signals. We further introduce multiple domain representations of the signal to extract features and combine them together to accurately classify new waveforms as an unknown class. Our results show that combined features from multiple domains outperform any single domain representation, especially at low SNR regimes with fewer number of samples to classify.

99 - GENERAL AND MISCELLANEOUS↗

Exploiting Multi-Domain Features for Detection of Unclassified Electromagnetic Signals (Presentation)

Deep Learning based classification techniques have shown excellent performance in static environments, where the training and testing samples are drawn from the same distribution. However, real world scenarios often present samples that do not belong to the known set of classes chosen during training. This is quite common for electromagnetic signals, where it is impractical to assume that all possible waveforms are known a-priori, specially in scenarios like warfare. To address this problem, we propose a deep learning based adversarial model where the generator learns to generate waveform features that can deceive the discriminator model as true samples. We introduce domain knowledge of wireless signals by decomposing the signal into a lower dimensional unique feature set, which is used for classifying known versus unknown signals. We further introduce multiple domain representations of the signal to extract features and combine them together to accurately classify new waveforms as an unknown class. Our results show that combined features from multiple domains outperform any single domain representation, especially at low SNR regimes with fewer number of samples to classify.

99 - GENERAL AND MISCELLANEOUS↗

Semiselective Optoelectronic Sensors for Monitoring Microbes

Sensor systems are under development for use in real-time detection and quantitation of microbes in water without need for sampling. These systems include arrays of optical sensors; miniature, portable electronic data-acquisition circuits; and optoelectronic interfaces between the sensor arrays and data-acquisition circuits. These systems are intended for original use in long-term, inline monitoring of waterborne micro-organisms in water-reclamation systems aboard future spacecraft. They could also be adapted to similar terrestrial uses with respect to municipal water supplies, stored drinking water, and swimming water; for detecting low-level biological contamination in biotechnological, semiconductor, and pharmaceutical process streams; and in verifying the safety of foods and beverages. In addition, they could be adapted to monitoring of airborne microbes and of surfaces (e.g., to detect and/or quantitate biofilms). The designs of the sensors in these systems are based partly on those of sensors developed previously for monitoring airborne biological materials. The designs exploit molecular- recognition and fluorescence-spectroscopy techniques, such that in the presence of micro-organisms of interest, fluorescence signals change and the changes can be measured. These systems are characterized as semiselective because they respond to classes of micro-organisms and can be used to discriminate among the classes. This semiselectivity is a major aspect of the design: It is important to distinguish between (1) the principle of detection and quantitation of classes of micro-organisms by use of these sensors and (2) the principle of detection and quantitation of individual microbiological species by means of prior immuno-diagnostic and/or molecular-biology techniques. Detection of classes (in contradistinction to species) is particularly valuable when the exact nature of a contaminant is unknown.

Tabacco, Mary Beth↗

Neural mechanisms of kinesthesia

Our primary interest is in where the signals for position and movement of the limbs originate and how the information is encoded. Humans can independently sense the positions and movements of their limbs in the absence of vision, and their senses are derived from mechanoreceptors located in the limbs. Receptors in muscles, skin and joints are potential sources of position and movement signals, but how (and whether) each of these groups contributes to kinesthesia remains uncertain. Recent evidence indicates that a sense of static-position derives from length receptors in muscle, whereas receptors in the skin, and possibly though not likely the joints, can signal movement of a limb but not its static position. At present, we are examining the consequences of not having a static-position sense at the fingers apart from an inability to detect very slow displacements. Using a more demanding test, we have found no substantial difference in the accuracy of reproducing target positions passively imposed on the MCP joint and the proximal interphalangeal (PIP) joint of the index finger. Our working hypothesis is that subjects normally use movement sense mechanisms to detect displacements, probably because they are faster, but how (or whether) subjects manage to obtain an absolute position reference with only a movement sense available remains unknown and is an issue under investigation.

Clark, Francis J.↗