Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASONOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula

PurposeThe present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses.MethodThe cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery.ResultsOf 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (range 41–78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery.ConclusionIn palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Stenting in Patients with Acute Lower Limb Arterial Occlusions: Immediate and Long-Term Results

PurposeThe purpose of this study is to accentuate the efficacy of direct stenting (stent placement without predilatation of the lesion) in patients with acute lower limb arterial ischemia (ALLI).Materials and MethodsBetween January 2010 and September 2015, 16 patients (11 men and 5 women) underwent direct stenting of acute arterial occlusions. All patients had contraindication for surgical revascularization or catheter-directed thrombolysis. According to SVS/ISCVS Classification, six patients had IIa and ten patients IIb ALLI. The occlusions were located in CIA, EIA, SFA, or popliteal artery. Mean follow-up time with clinical examination and color Duplex ultrasonography was 37.6 months (range 1–72). We analyzed the technical and clinical outcomes of the procedures, as well the complications and patency rates.ResultsTechnical success was achieved in all patients (16/16) and there was significant clinical improvement in 15 patients. There was neither distal embolization nor procedure-related complications. During the 6 years of follow-up, four patients died due to non-procedure-related causes and there were two minor and one major amputations. The primary patency rates and the amputation-free survival rates were 93.7 and 87% at 1 year, 75.2 and 71.2% at 3 years, and 75.2 and 62.3%, respectively, at 6 years.ConclusionsDirect stenting may be a valuable alternative procedure for acute arterial occlusions in selected cases with high technical success and significant clinical improvement.Level of EvidenceLevel 4, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutting Balloon Angioplasty (CBA) for the Treatment of Renal Artery Fibromuscular Dysplasia (FMD) in Six Patients: 5-Year Long-Term Results

PurposeTo evaluate long-term outcomes in terms of hypertension control, recurrent stenosis, and reinterventions from patients who underwent cutting balloon angioplasty (CBA) for symptomatic renal artery fibromuscular dysplasia (FMD).Materials and MethodsFrom 2011, six consecutive renal artery FMD women underwent CBA for poorly controlled hypertension, despite antihypertensive therapy. Follow-up consisted of blood pressure monitoring and duplex ultrasonography at 1, 6, and 12 months and thereafter annually for 5 years.ResultsAll treatments were technically successful. Recurrence of hypertension was found in two patients within 12 months, and reinterventions were performed using CBA.ConclusionResults show the efficacy of CBA for renal artery FMD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions

PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prophylactic Occlusion Balloon Placement in the Abdominal Aorta Combined with Uterine or Ovarian Artery Embolization for the Prevention of Cesarean Hysterectomy Due to Placenta Accreta: A Retrospective Study

Objective: To evaluate the outcomes of uterine-conserving surgery with the occlusion balloon technique followed by uterine or ovarian artery embolization (OAE) in women with placenta accreta. Methods: A total of 31 consecutive patients, who were diagnosed with placenta accreta through grayscale ultrasonography or magnetic resonance imaging prenatally, were retrospectively analyzed in our hospital between October 2015 and September 2017. All of the women underwent a Cesarean section combined with prophylactic placement of a balloon catheter in the abdominal aorta followed by uterine artery embolization (UAE) or OAE when necessary. Results: Technical success was achieved in 31 cases (100%), including successful catheterization and inflation of balloons. The uterus was conserved in 30 (96.77%) patients. The estimated blood loss, packed RBC transfused, and the operation time were 1906.45 ± 1117.64 ml, 4(0–6) U, and 88.68 ± 28.35 min, respectively. Out of all of the patients, we found nine cases of bleeding after the release of the balloon. Among these patients, six cases originated from the ovarian arteries and three cases originated from uterine arteries. Further embolization was performed through catheterization. The mean fetal radiation exposure was 4.33 ± 0.79 mGy. Conclusions: Prophylactic abdominal aorta balloon occlusion followed by UAE or OAE can effectively control postpartum hemorrhaging with reduced blood loss, transfusion requirements, and hysterectomy rates in patients with placenta accreta.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Post-thrombotic Venous Ilio-Femoral Occlusions: Prognostic Value of Venous Lesions Caudal to the Common Femoral Vein

Objectives: To propose a scale of severity for post-thrombotic venous lesions (PTVLs) after ilio-femoral deep venous thrombosis and to compare the grade with the results of endovascular treatment of ilio-femoral PTVLs. Methods: In this retrospective monocentric observational study, we included 95 patients treated for ilio-femoral PTVLs. We proposed a four-grade scale evaluating the severity of PTVLS caudal to the common femoral vein based on CT phlebography and per-operative phlebography. For most patients, venous patency was assessed with color duplex ultrasonography and the clinical efficacy of the intervention using the Villalta and CIVIQ scores. Results: Recanalization was successful in 100% of patients with a morbidity rate of 4%. After a mean follow-up of 21 months, the overall primary patency was 75%, the assisted primary patency 82%, and the secondary patency 93%. Secondary patency was 100% for grade 0–1, 90% for grade 2, and 63% for grade 3 (p < 0.002). There was no correlation between the extension of stenting caudally of the common femoral vein and venous patency. The mean improvements in the Villalta and CIVIQ-20 scores were, respectively, 4.6 (p < 0.0001) and 18 (p < 0.0001); scores were not correlated with the grade of PTVLs in the thigh. Conclusion: Venous patency after endovascular treatment of ilio-femoral PTVLs was strongly linked to the severity of PTVLs caudal to the common femoral vein but not to the extent of stenting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Laser Ablation of Liver Metastases from Neuroendocrine Neoplasm. A Retrospective Study for Safety and Effectiveness

Purpose: To retrospectively assess safety and efficacy of laser ablation (LA) of multiple liver metastases (LM) from neuroendocrine neoplasms (NEN). Methods: Twenty-one patients with NEN and at least 3 LM ≤ 4 cm in diameter underwent ultrasonography-guided LA. Up to seven LM were ablated in a single session; if the number of LM exceeded seven, the remaining LM were ablated in further LA sessions with a time interval of 3–4 weeks. LA was performed according to the multifiber technique. The patients underwent contrast-enhanced CT 1 month after LA, and were subsequently monitored every 3 months for the first 2 years and then every 6 months. Results: In total, 189 LM were treated in 21 patients (mean 9 ± 8.2, median 6) in 41 LA sessions (range 1–5). The diameter of LM ranged from 5 to 35 mm (median 19 mm, mean 17.9 ± 6.4 mm). One grade 4 complication occurred (0.53%): a bowel perforation managed by surgery. Technical efficacy was 100%, primary efficacy rate 94.7%, and secondary efficacy rate 100%. Complete relief of hormone-related symptoms was obtained in all the 13 symptomatic patients. Median follow-up was 39 months (range 12–99). 1-, 2-, 3-, and 5-year survival rates were 95%, 86%, 66%, and 40%, respectively. Overall survival resulted higher for patients with Ki-67 expression ≤ 7% than for those with Ki-67 > 7% (p = 0.0347). Conclusions: LA is a promising and safe technique to treat LM from NEN. A longer follow-up should provide definitive information on the long-term efficacy of this liver-directed therapy. Level of Evidence: Retrospective study, local non-random sample, level 3.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Blunt Chest Trauma: A Radiologic Approach and Review

Blunt chest trauma, a frequent component of trauma admissions, is the second leading cause of death in motor-vehicle accidents. Additionally, it may be associated with significant morbidity in those who survive. Radiography, ultrasonography, and computed tomography (CT) have a widespread role in evaluating blunt chest trauma, importantly aiding in the diagnosis and management of injury. Herein, we discuss the most common salient injuries, imaging protocol considerations and imaging findings associated with acute blunt chest trauma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Evaluation of Radiation Dose Delivered in Prostate Cancer Patients as Measured by an Implantable MOSFET Dosimeter

Purpose: To perform a comparison of the daily measured dose at depth in tissue with the predicted dose values from treatment plans for 29 prostate cancer patients involved in a clinical trial. Methods and Materials: Patients from three clinical sites were implanted with one or two dosimeters in or near the prostatic capsule. The implantable device, known as the DVS, is based on a metal-oxide-semiconductor field effect transistor (MOSFET) detector. A portable telemetric readout system couples to the dosimeter antenna (visible on kilovoltage, computed tomography, and ultrasonography) for data transfer. The predicted dose values were determined by the location of the MOSFET on the treatment planning computed tomography scan. Serial computed tomography images were taken every 2 weeks to evaluate any migration of the device. The clinical protocol did not permit alteration of the treatment parameters using the dosimeter readings. For some patients, one of several image-guided radiotherapy (RT) modalities was used for target localization. Results: The evaluation of dose discrepancy showed that in many patients the standard deviation exceeded the previous values obtained for the dosimeter in a phantom. In some patients, the cumulative dose disagreed with the planned dose by {>=}5%. The data presented suggest that an implantable dosimeter can help identify dose discrepancies (random or systematic) for patients treated with external beam RT and could be used as a daily treatment verification tool for image-guided RT and adaptive RT. Conclusion: The results of our study have shown that knowledge of the dose delivered per fraction can potentially prevent over- or under-dosage to the treatment area and increase the accuracy of RT. The implantable dosimeter could also be used as a localizer for image-guided RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance Issues for Computed Tomography-, Ultrasound-, and Magnetic Resonance Imaging-Guided Brachytherapy

The requirements of quality assurance (QA) for both brachytherapy and imaging devices are well-defined, but image-guided brachytherapy has raised new issues. Image guidance in brachytherapy involves the transition from reference point dosimetry using films to volumetric imaging such as computed tomography, ultrasonography, and magnetic resonance imaging for treatment planning and guidance of applicator, needle, or seed placement. The QA of these devices might not reflect the conditions of use in brachytherapy or the requirements of brachytherapy treatment planning. Image interpretation becomes much more important with image-guided brachytherapy. The success of a procedure could depend on the interpretation of a single image in a calibration phase done under the time pressures of the operative setting. This change has implications at the level of treatment, the process, and the field of brachytherapy as a whole. The QA concerns arising from brachytherapy procedures using ultrasound, computed tomography, and magnetic resonance imaging guidance are discussed, as are the problems associated with using imaging in an interventional setting. This report was intended to indicate the QA concerns arising from the convergence of brachytherapy and imaging-highlighting areas in which technical improvements are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Dose on Risk of Acute Urinary Retention After Iodine-125 Prostate Brachytherapy

Purpose: To assess the influence of dose on the risk of acute urinary retention (AUR) after iodine-125 prostate brachytherapy. Methods and Materials: Between January 2005 and December 2008, 714 consecutive patients with localized prostate cancer were treated with iodine-125 prostate brachytherapy at our department. All patients completed four imaging studies: magnetic resonance imaging before and 4 weeks after treatment and intraoperative three-dimensional transrectal ultrasonography before and after implantation. The development of AUR was prospectively recorded. The evaluated treatment and dosimetric parameters included prostate volume, number of needles and seeds used, intra- and postoperative prostate edema, percentage of prostate volume receiving 100%, 150%, and 200% of the prescribed dose to the prostate, minimal dose received by 90% of the prostate volume, and percentage of the urethra receiving 100%, 150%, and 200% of the prescribed dose. Logistic regression analysis was used to examine which factors were associated with AUR. Results: Of the 714 patients, 57 (8.0%) developed AUR. On univariate analysis, the following treatment and dosimetric factors were significantly associated with AUR: International Prostate Symptom Score (odds ratio [OR], 2.07, per 10-point increase), preimplant prostate volume (OR, 1.06), postimplant prostate volume (OR, 1.04), number of needles used (OR, 1.09), and number of seeds used (OR, 1.03). On multivariate analysis, the only independent predictive factors for AUR were pretreatment prostate volume (OR, 1.05) and International Prostate Symptom Score (OR, 1.76, per 10-point increase). Patients with a pretreatment prostate volume >35 cm{sup 3} had a 10.4% risk of developing AUR compared with 5.4% for those with a prostate volume of {<=}35 cm{sup 3}. No association was found between any of the dosimetric parameters and the development of AUR. Conclusion: The radiation dose, within the range studied, did not influence the risk of AUR after iodine-125 prostate brachytherapy. Prostate volume and International Prostate Symptom Score were the most important predictors of AUR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential Impact of Preoperative Magnetic Resonance Imaging of the Breast on Patient Selection for Accelerated Partial Breast Irradiation

Purpose: Accelerated partial breast irradiation (APBI) after breast-conserving therapy is currently under investigation in prospective randomized studies. Multifocality and multicentricity are exclusion criteria for APBI. Preoperative breast magnetic resonance imaging (MRI) can detect ipsilateral and contralateral invasive tumor foci or ductal carcinoma in situ in addition to conventional diagnostic methods (clinical examination, mammography, and ultrasonography). The objective of this retrospective study was to evaluate the impact of preoperative MRI on patient selection for APBI. Methods and Materials: From 2002 to 2007, a total of 579 consecutive, nonselected patients with newly diagnosed early-stage breast cancer received preoperative breast MRI in addition to conventional imaging studies at the Bonn University Breast Cancer Center. In retrospect, 113 patients would have met the criteria for APBI using conventional imaging workup (clinical tumor size {<=}3 cm; negative axillary lymph node status; unifocal disease; no evidence of distant metastases; no invasive lobular carcinoma, ductal and lobular carcinoma in situ, or Paget's disease). We analyzed the amount of additional ipsilateral and contralateral tumor foci detected by MRI. Results: MRI detected additional tumor foci in 8.8% of patients eligible for APBI (11 tumor foci in 10 of 113 patients), either ipsilateral (n = 7, 6.2%) or contralateral (n = 4, 3.5%). In 1 patient, MRI helped detect additional tumor focus both ipsilaterally and contralaterally. Conclusions: Preoperative breast MRI is able to identify additional tumor foci in a clinically relevant number of cases in this highly selected group of patients with low-risk disease and may be useful in selecting patients for APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Brachytherapy With Oblique Needles to Treat Large Glands and Overcome Pubic Arch Interference

Purpose: First, to show that low-dose-rate prostate brachytherapy plans using oblique needle trajectories are more successful than parallel trajectories for large prostates with pubic arch interference (PAI); second, to test the accuracy of delivering an oblique plan by using a three-dimensional (3D) transrectal ultrasonography (TRUS)-guided mechatronic system. Methods and Materials: Prostates were contoured for 5 subjects' 3D TRUS images showing a maximum PAI of {<=}1 cm and a prostate volume of <50 cc. Two planning studies were done. First, prostate contours were artificially enlarged to 45 to 80 cc in 5- to 10-cc increments for a single subject. Second, all subject prostate contours were enlarged to 60 cc. For each study, three types of plans were manually created for comparison: a parallel needle template (PT) plan, a parallel needle no-template (PNT) plan, and an oblique needle no-template (OBL) plan. Needle positions and angles were not discretized for nontemplate plans. European Society for Therapeutic Radiology and Oncology dose-volume histogram guidelines, iodine-125 (145-Gy prescription, 0.43 U), and needle angles of <15 Degree-Sign were used. An OBL plan was delivered to a pubic arch containing a 60-cc prostate phantom that mimicked the anatomy of the subject with the greatest PAI (23% by volume). Results: In the increasing-prostate volume study, OBL plans were successful for prostates of {<=}80 cc, and PT plans were successful for prostates of <65 cc. In paired, one-sided t tests for the 60-cc volume study, OBL plans showed dosimetric improvements for all organs compared to both of the parallel type plans (p < 0.05); PNT plans showed a benefit only in planning target volumes receiving more than 100 Gy compared to PT plans. A computed tomography scan of the phantom showed submillimeter seed placement accuracy in all directions. Conclusion: OBL plans were significantly better than parallel plans, and an OBL plan was accurately delivered to a 60-cc prostate phantom with 23% PAI by volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Bed Motion During Intensity-Modulated Radiotherapy Treatment

Purpose: Conformal radiation therapy in the postprostatectomy setting requires accurate setup and localization of the prostatic fossa. In this series, we report prostate bed localization and motion characteristics, using data collected from implanted radiofrequency transponders. Methods and Materials: The Calypso four-dimensional localization system uses three implanted radiofrequency transponders for daily target localization and real-time tracking throughout a course of radiation therapy. We reviewed the localization and tracking reports for 20 patients who received ultrasonography-guided placement of Calypso transponders within the prostate bed prior to a course of intensity-modulated radiation therapy at Fox Chase Cancer Center. Results: At localization, prostate bed displacement relative to bony anatomy exceeded 5 mm in 9% of fractions in the anterior-posterior (A-P) direction and 21% of fractions in the superior-inferior (S-I) direction. The three-dimensional vector length from skin marks to Calypso alignment exceeded 1 cm in 24% of all 652 fractions with available setup data. During treatment, the target exceeded the 5-mm tracking limit for at least 30 sec in 11% of all fractions, generally in the A-P or S-I direction. In the A-P direction, target motion was twice as likely to move posteriorly, toward the rectum, than anteriorly. Fifteen percent of all treatments were interrupted for repositioning, and 70% of patients were repositioned at least once during their treatment course. Conclusion: Set-up errors and motion of the prostatic fossa during radiotherapy are nontrivial, leading to potential undertreatment of target and excess normal tissue toxicity if not taken into account during treatment planning. Localization and real-time tracking of the prostate bed via implanted Calypso transponders can be used to improve the accuracy of plan delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1 Clinical Trial of Stereotactic Body Radiation Therapy Concomitant With Neoadjuvant Chemotherapy for Breast Cancer

Purpose: Stereotactic body radiation therapy (SBRT) allows stereotactic irradiation of thoracic tumors. It may have a real impact on patients who may not otherwise qualify for breast-conserving surgery. We conducted a phase 1 trial that tested 5 dose levels of SBRT concomitant with neoadjuvant chemotherapy (NACT) before to surgery. The purpose of the current dose escalation study was to determine the maximum tolerable dose of SBRT in the treatment of breast cancer. Methods and Materials: To define toxicity, we performed dermatologic examinations that included clinical examinations by 2 separate physicians and technical evaluations using colorimetry, dermoscopy, and skin ultrasonography. Dermatologic examinations were performed before NACT, 36 and 56 days after the beginning of NACT, and before surgery. Surgery was performed 4 to 8 weeks after the last chemotherapy session. Efficacy, the primary endpoint, was determined by the pathologic complete response (pCR) rate. Results: Maximum tolerable dose was not reached. Only 1 case of dose-limiting toxicity was reported (grade 3 dermatologic toxicity), and SBRT was overall well tolerated. The pCR rate was 36%, with none being observed at the first 2 dose levels, and the highest rate being obtained at dose level 3 (25.5 Gy delivered in 3 fractions). Furthermore, the breast-conserving surgery rate was up to 92% compared with an 8% total mastectomy rate. No surgical complications were reported. Conclusions: This study demonstrates that SBRT can be safely combined with NACT. Regarding the efficacy endpoints, this trial showed promising results in terms of pCR rate (36%) and breast-conserving rate (92%). The findings provide a strong rationale for extending the study into a phase 2 trial. In view of the absence of correlation between dose and pCR, and given that the data from dose level 3 met the statistical requirements, a dose of 25.5 Gy in 3 fractions should be used for the phase 2 trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancer during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer Tumors Greater Than 5 cm: Safety and Efficacy

Purpose: The purpose of this study was to determine outcomes of patients with node-negative medically inoperable non-small cell lung cancer (NSCLC) whose primary tumors exceeded 5 cm and were treated with stereotactic body radiation therapy (SBRT). Methods and Materials: We surveyed our institutional prospective lung SBRT registry to identify treated patients with tumors >5 cm. Treatment outcomes for local control (LC), locoregional control (LRC), disease-free survival (DFS), and overall survival (OS) were assessed by Kaplan-Meier estimates. Toxicities were graded according to Common Terminology Criteria for Adverse Events version 4. Mean pretreatment pulmonary function test values were compared to mean posttreatment values. Results: From December 2003 to July 2014, 40 patients met study criteria. Median follow-up was 10.8 months (range: 0.4-70.3 months). Median age was 76 years (range: 56-90 years), median body mass index was 24.3 (range: 17.7-37.2), median Karnofsky performance score was 80 (range: 60-90), and median Charlson comorbidity index score was 2 (range: 0-5). Median forced expiratory volume in 1 second (FEV1) was 1.41 L (range: 0.47-3.67 L), and median diffusion capacity (DLCO) was 47% of predicted (range: 29%-80%). All patients were staged by fluorodeoxyglucose-positron emission tomography/computed tomography staging, and 47.5% underwent mediastinal staging by endobronchial ultrasonography. Median tumor size was 5.6 cm (range: 5.1-10 cm), median SBRT dose was 50 Gy (range: 30-60 Gy) in 5 fractions (range: 3-10 fractions). Eighteen-month LC, LRC, DFS, and OS rates were 91.2%, 64.4%, 34.6%, and 59.7%, respectively. Distant failure was the predominant pattern of failure (32.5%). Three patients (7.5%) experienced grade 3 or higher toxicity. Mean posttreatment FEV1 was not significantly reduced (P=.51), but a statistically significant absolute 6.5% (P=.03) reduction in DLCO was observed. Conclusions: Lung SBRT for medically inoperable node-negative NSCLC with primary tumors larger than 5 cm is safe and provides excellent local control with limited toxicity. The predominant pattern of failure in this population was distant failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗