Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ultrasonication of Bismuth Telluride Nanocrystals Fabricated by Solvothermal Method

The objective of this study is to evaluate the effect of ultrasonication on bismuth telluride nanocrystals prepared by solvothermal method. In this study, a low dimensional nanocrystal of bismuth telluride (Bi2Te3) was synthesized by a solvothermal process in an autoclave at 180 C and 200 psi. During the solvothermal reaction, organic surfactants effectively prevented unwanted aggregation of nanocrystals in a selected solvent while controlling the shape of the nanocrystal. The atomic ratio of bismuth and tellurium was determined by energy dispersive spectroscopy (EDS). The cavitational energy created by the ultrasonic probe was varied by the ultrasonication process time, while power amplitude remained constant. The nanocrystal size and its size distribution were measured by field emission scanning electron microscopy (FESEM) and a dynamic light scattering system. When the ultrasonication time increased, the average size of bismuth telluride nanocrystal gradually increased due to the direct collision of nanocrystals. The polydispersity of the nanocrystals showed a minimum when the ultrasonication was applied for 5 min. Keywords: bismuth telluride, nanocrystal, low-dimensional, ultrasonication, solvothermal

Chu, Sang-Hyon↗

Ultrasonic Apparatus for Pulverizing Brittle Material

The figure depicts an apparatus that pulverizes brittle material by means of a combination of ultrasonic and sonic vibration, hammering, and abrasion. The basic design of the apparatus could be specialized to be a portable version for use by a geologist in collecting powdered rock samples for analysis in the field or in a laboratory. Alternatively, a larger benchtop version could be designed for milling and mixing of precursor powders for such purposes as synthesis of ceramic and other polycrystalline materials or preparing powder samples for x-ray diffraction or x-ray fluorescence measurements to determine crystalline structures and compositions. Among the most attractive characteristics of this apparatus are its light weight and the ability to function without need for a large preload or a large power supply: It has been estimated that a portable version could have a mass <0.5 kg, would consume less than 1 W h of energy in milling a 1-cm3 volume of rock, and could operate at a preload <10 N. The basic design and principle of operation of this apparatus are similar to those of other apparatuses described in a series of prior NASA Tech Briefs articles, the two most relevant being Ultrasonic/ Sonic Drill/Corers With Integrated Sensors (NPO-20856), Vol. 25, No. 1 (January 2001), page 38 and Ultrasonic/ Sonic Mechanisms for Deep Drilling and Coring (NPO-30291), Vol. 27, No. 9 (September 2003), page 65. As before, vibrations are excited by means of a piezoelectric actuator, an ultrasonic horn, and a mass that is free to move axially over a limited range. As before, the ultrasonic harmonic motion of the horn drives the free-mass in a combination of ultrasonic harmonic and lower-frequency hammering motion. In this case, the free-mass is confined within a hollow cylinder that serves as a crushing chamber, and the free-mass serves as a crushing or milling tool. The hammering of the free-mass against a material sample at the lower end of the chamber grinds the sample into powder in a relatively short time. The restriction of the free-mass to axial motion only makes the grinding very efficient. The free-mass can be fabricated to have teeth on its lower face to enhance the grinding effect. Optionally, there can be a hole at the bottom of the chamber covered with a sieve to tailor the size distribution of the powder leaving the crushing chamber.

Sherrit, Stewart↗

An Analysis of Peak Wind Speed Data from Collocated Mechanical and Ultrasonic Anemometers

This study focuses on a comparison of peak wind speeds reported by mechanical and ultrasonic anemometers at Cape Canaveral Air Force Station and Kennedy Space Center (CCAFS/KSC) on the east central coast of Florida and Vandenberg Air Force Base (VAFB) on the central coast of California. The legacy mechanical wind instruments on CCAFS/KSC and VAFB weather towers are being changed from propeller-and-vane (CCAFS/KSC) and cup-and-vane (VAFB) sensors to ultrasonic sensors under the Range Standardization and Automation (RSA) program. The wind tower networks on KSC/CCAFS and VAFB have 41 and 27 towers, respectively. Launch Weather Officers, forecasters, and Range Safety analysts at both locations need to understand the performance of the new wind sensors for a myriad of reasons that include weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The Legacy sensors measure wind speed and direction mechanically. The ultrasonic RSA sensors have no moving parts. Ultrasonic sensors were originally developed to measure very light winds (Lewis and Dover 2004). The technology has evolved and now ultrasonic sensors provide reliable wind data over a broad range of wind speeds. However, because ultrasonic sensors respond more quickly than mechanical sensors to rapid fluctuations in speed, characteristic of gusty wind conditions, comparisons of data from the two sensor types have shown differences in the statistics of peak wind speeds (Lewis and Dover 2004). The 45th Weather Squadron (45 WS) and the 30 WS requested the Applied Meteorology Unit (AMU) to compare data from RSA and Legacy sensors to determine if there are significant differences in peak wind speed information from the two systems.

Short, David A.↗

Ultrasonic Measurement and Monitoring of Loads in Bolts used in Structural Joints

The paper is an overview of work by the author in measuring and monitoring loads in bolts using an ultrasonic extensometer. A number of cases of bolted joints are covered. These include, a clamped joint with clearance fit between the bolt and hole, a clamped joint with the bolt in an interference fit with the hole, a flanged joint which allows the flange and bolt to bend; and a shear joint in a clevis and tang configuration. These applications were initially developed for measuring and monitoring preload in the NASA Space Shuttle Orbiter critical joints but are also applicable for monitoring loads in other critical bolted joints of structures such as transportation bridges and other aerospace structures. The paper explains how to set‐up a model to estimate the load factor and accuracy for the ultrasonic preload application in a clamped joint with clearance fit. The ultrasonic preload application for clamped joint with bolt in an interference fit can also be used to measure diametrical interference between the bolt shank and hole; and interference pressure on the bolt shank. Model and experimental data are given to demonstrate use of ultrasonic measurements in a shear joint. A bolt in a flanged joint experiences both tensile and bending loads. This application involves measurement of bending and tensile preload in a bolt. The ultrasonic beam bends due to the bending load on the bolt. A numerical technique to compute the trace of ultrasonic ray is presented.

Koshti, Ajay↗

Assessment and Calibration of a Crimp Tool Equipped with Ultrasonic Analysis Features

A method is provided for calibrating ultrasonic signals passed through a crimp formed with respect to a deformable body via an ultrasonically-equipped crimp tool (UECT). The UECT verifies a crimp quality using the ultrasonic signals. The method includes forming the crimp, transmitting a first signal, e.g., a pulse, to a first transducer of the UECT, and converting the first signal, using the first transducer, into a second signal which defines an ultrasonic pulse. This pulse is transmitted through the UECT into the crimp. A second transducer converts the second signal into a third signal, which may be further conditioned, and the ultrasonic signals are calibrated using the third signal or its conditioned variant. An apparatus for calibrating the ultrasonic signals includes a pulse module (PM) electrically connected to the first and second transducers, and an oscilloscope or display electrically connected to the PM for analyzing an electrical output signal therefrom.

Yost, William T.↗

Ultrasonic Device for Assessing the Quality of a Wire Crimp

A system for determining the quality of an electrical wire crimp between a wire and ferrule includes an ultrasonically equipped crimp tool (UECT) configured to transmit an ultrasonic acoustic wave through a wire and ferrule, and a signal processor in communication with the UECT. The signal processor includes a signal transmitting module configured to transmit the ultrasonic acoustic wave via an ultrasonic transducer, signal receiving module configured to receive the ultrasonic acoustic wave after it passes through the wire and ferrule, and a signal analysis module configured to identify signal differences between the ultrasonic waves. The signal analysis module is then configured to compare the signal differences attributable to the wire crimp to a baseline, and to provide an output signal if the signal differences deviate from the baseline.

Yost, William T.↗

Local Ultrasonic Resonance Spectroscopy of Lithium Metal Batteries for Aerospace Applications

As next-generation aircraft and vehicles continue to develop, so do their associated energy demands. Lithium metal batteries are a leading candidate to fulfill this energy requirement, but these batteries are prone to internal dendrite defects that can lead to catastrophic thermal runaway events. Current battery management systems are capable of mitigating such risks, but are unable to detect such defects until thermal runaway has already begun. Various nondestructive evaluation (NDE) techniques, particularly ultrasonic NDE, can directly monitor internal battery parameters giving them the potential to detect critical defects prior to catastrophic failure. However, most of the current battery NDE research has focused on improved battery state-of-charge (SOC) and stateof- health (SOH) monitoring with little emphasis on critical defect detection. Thus, a measurement technique sensitive to subtle battery defects is needed. In addition, the complex mechanics of ultrasound in porous, thin, multilayered batteries prompt the use of physics-based simulation to guide inspections. In this work, an ultrasonic NDE technique has been developed utilizing frequency domain analysis of local battery resonances to detect the presence of battery defects. This technique is a practical extension of local ultrasonic resonance spectroscopy (LURS) – which previously required non-contact laser ultrasonics – to measurements with piezoelectric contact and immersion scan transducers. To extend the technique to work with piezoelectric transducers, ultrasonic battery measurements were compared to a sans-battery calibration measurement. Then, a linear systems deconvolution was used to eliminate the transfer functions of extraneous factors such as the transducer and electronics, leaving only the frequency-dependent battery reflection coefficient. The LURS technique was first validated on stainless steel and aluminum plates, producing reflection coefficients in line with analytical and numerical finite element modeling (FEM) results. Functioning Li-metal pouch cells were then seeded with lithium chip defects prior to LURS measurements. The presence of these defects is shown to cause a measurable shift in the battery’s through-thickness local resonances. 2D, frequency-domain poroelastic models of ultrasonic propagation in a single-cell lithium metal pouch battery were created and corroborated these findings. Thus, this work has both extended and proven the feasibility of the LURS technique in the detection of local battery defects.

Ultrasound↗

Sources of Uncertainty in Ultrasonic Phase-Based Assessment of Interfacial Stiffness in Adhesive Joints

Quantitative nondestructive evaluation (NDE) of adhesive joint strength is critical for certifying fastener-free bonded aerospace structures. Unfortunately, available adhesive NDE approaches are only suitable for detecting gross defects and delamination and cannot reliably detect variations in strength in intact bonds. Intact (i.e., nominally defect free) bonds are challenging to inspect because they, by definition, contain no macroscopic defects that would produce a strong NDE signature. Even in the absence of obvious defects, however, bond strength can vary substantially due to factors such as contamination, variations in the adhesive cure processes, and environmental exposure. For ultrasonic bond inspections, the effect of interactions from an imperfect adhesive interface are subtle and may include changes in the frequency content or phase of the ultrasonic signal. The bond condition can be deduced from these subtle changes in the acoustic response using an accompanying physics-based model of adhesive joint interaction. For example, researchers have used the spring network adhesion model of Baik and Thompson [1] to determine the interfacial stiffness of the joint from its ultrasonic response (e.g., [2]). This interfacial stiffness metric describes the bonds resistance to separation between the adhesive and adherent and has shown a strong correlation with joint strength. In this study, interfacial stiffness is assessed using the ultrasonic phase change associated with bond interaction in varying bond conditions. The phase change is measured precisely using a phase-locked-loop instrument over a swept range of frequencies. The phase transition at resonance, where the bond thickness is half the acoustic wavelength, produces a unique signature with which to fit a physics-based model. Interfacial stiffness is determined by minimizing the difference between the theoretical and experimental phase response. Experimental results are presented for glass specimens bonded with aerospace adhesives and a sensitivity analysis is performed to examine the effects of parameters that may be uncertain in the industrial inspection environment – namely bond thickness, adhesive and adherent properties, and porosity. The results are a first step toward an uncertainty quantified version of the measurement technique, show correlation between interfacial stiffness and bond strength, and are another key step toward maturing this approach for use in complex materials and joint geometries. [1] Baik, J.M. and Thompson, R.B., 1984. “Ultrasonic scattering from imperfect interfaces: a quasi-static model”. Journal of Nondestructive Evaluation, 4. [2] Haldren, H.A., Perey, D.F., Yost, W.T., Cramer, K.E., and Gupta, M.C., 2019. “Swept-frequency ultrasonic phase evaluation of adhesive bonding in tri-layer structures”. Journal of the Acoustical Society of America, 145.

Matt Webster↗

Porosity Prediction and Detection During Composite Cure Using Simulation and Ultrasonic In-Situ Inspection Inside and Autoclave

Composite materials offer unique benefits in aerospace applications such as increased strength-to-weight ratio and improved fatigue properties. They are increasingly being used in major commercial aircraft programs. However, current processing methods can lead to defects in composite parts, which are currently identified using post-manufacturing inspection methods. A cure defects process model has been developed to predict the formation of manufacturing defects (e.g., porosity and fiber waviness) in composites based on the cure parameters and part geometry. However, a capability to directly validate porosity during cure did not exist. Validation methods included comparing resin pressure measured during cure with predictions by the process model and inspection/microscopy after cure. This study developed a high-temperature ultrasonic inspection system to detect porosity defects in composites during autoclave cure and experimentally verify the predictions of the model. The system operated inside an autoclave within an enclosure cooled by intermittent liquid nitrogen(LN2) injections. A high-temperature 2.25 MHz ultrasonic transducer was utilized to transmit ultrasonic waves through the tool plate and into the composite material and to measure the amplitude and time of flight of the reflected waves with a 1 mm × 1 mm resolution. Porosity was observed via the ultrasonic reflections, which experienced increased attenuation in regions of high porosity. Distinct regions of increased porosity were present due to uneven pressure across the panel, which was driven by an intentional misfit between the flat caul plate and the tapered composite panel with ply drops. These observations matched the predictions of the model using the inputs from the experiment (e.g., part material and geometry, cure cycle) and were validated by post-cure ultrasonic inspection and micrographs. The in-situ inspection system was able to successfully provide defect detection and localization and can be applied to future manufacturing of composite structure for aerospace applications.

Porosity↗

Porosity Detection and Localization During Composite Cure Inside an Autoclave Using Ultrasonic Inspection

Composite materials offer unique benefits in aerospace applications such as increased strength-to-weight ratio and improved fatigue properties. They are increasingly being used in major commercial aircraft programs. However, current processing methods can lead to defects in composite parts, which must be detected using post-manufacturing inspection methods. Porosity (i.e., pores, voids) is a critical defect from the cure process that is detrimental to performance of the composite part. It is therefore necessary to understand and eliminate the formation of porosity defects. At NASA Langley Research Center, an in-situ cure monitoring system was developed to detect porosity defects as they form in real-time inside an autoclave. A capability to directly detect and localize porosity within a composite during cure did not exist before. This study is focused on an elevated-temperature ultrasonic inspection system to detect porosity defects in composites during autoclave cure. The ultrasonic inspection system operated inside an autoclave within an enclosure cooled by intermittent liquid nitrogen (LN_2) injections. A high-temperature, 2.25 MHz, transducer transmitted ultrasonic waves through the tool plate and into the composite part and measured the amplitude and time of flight of the reflected waves with a 1 mm × 1 mm step size/areal resolution. Porosity was observed via the ultrasonic reflections, which experienced increased attenuation in regions of high porosity. Distinct regions of increased porosity were present due to uneven pressure across the panel, which was driven by an intentional misfit between the flat caul plate and the tapered composite panel with ply drops. The results were validated by post-cure ultrasonic inspection and micrographs. The in-situ inspection system was able to successfully provide porosity detection and localization in the tapered ply-drop panel. The successful results indicate the promise of this system for future implementation in the manufacturing of composite structures for aerospace applications.

Composites↗

Ultrasonic investigation of the superconducting properties of the Nb-Mo system

The superconducting properties of single crystals of Nb and two alloys of Nb with Mo were investigated by ultrasonic techniques. The results of measurements of the ultrasonic attenuation and velocities as a function of temperature, Mo composition, crystallographic direction, and ultrasonic frequency are reported. The attenuation and small velocity changes associated with the superconductivity of the samples are shown to be dependent on the sample resistivity ratio which varied from 4.3 for Nb-9% Mo to 6500 for pure Nb. The ultrasonic attenuation data are analyzed in terms of the superconducting energy gap term of the BCS theory. A new model is proposed for the analysis of ultrasonic attenuation in pure superconductors with two partially decoupled energy bands. To analyze the attenuation in pure superconducting Nb, the existence of two energy gaps was assumed to be associated with the two partially decoupled energy bands. One of the gaps was found to have the normal BCS value of 3.4 and the other gap was found to have the anomalously large value of 10. No experimental evidence was found to suggest that the second energy gap had a different transition temperature. The interpretation of the results for the Nb-Mo alloys is shown to be complicated by the possible existence of a second superconducting phase in Nb-Mo alloys with a transition temperature of 0.35 of the transition temperature of the first phase. The elastic constants of Nb and Nb-Mo alloys are shown to be approximately independent of Mo composition to nine atomic percent Mo. These results do not agree with the current microscopic theory of transition temperature for the transition elements.

Lacy, L. L.↗

Ultrasonic evaluation of high voltage circuit boards

Preliminary observations indicate that an ultrasonic scanning technique may be useful as a quick, low cost, nondestructive method for judging the quality of circuit board materials for high voltage applications. Corona inception voltage tests were conducted on fiberglass-epoxy and fiberglass-polyimide high pressure laminates from 20 to 140 C. The same materials were scanned ultrasonically by utilizing the single transducer, through-transmission technique with reflector plate, and recording variations in ultrasonic energy transmitted through the board thickness. A direct relationship was observed between ultrasonic transmission level and corona inception voltage. The ultrasonic technique was subsequently used to aid selection of high quality circuit boards for the Communications Technology Satellite.

Klima, S. J.↗

A CW ultrasonic bolt-strain monitor

There exists a need for a relatively inexpensive system for measuring strain in bolts. The torque wrench is one technique for straining bolts which has been widely applied. Unfortunately, friction in the bolt threads and between the nut and the work tend to make such a simple system inaccurate. In practice, a torque wrench is unacceptable for many situations where strain is critical. In this article, an ultrasonic technique is described which can indicate changes in bolt strain to better than one part in 10,000. The technique is based on the one-dimensional propagating-ultrasonic-wave model and uses a new ultrasonic instrument called a Reflection Oscillator Ultrasonic Spectrometer which is a closed-loop feedback marginal-oscillator system that frequency locks the device to the peak of a mechanical resonance in the bolt. The instrument indicates a shift in the bolt resonance frequency due to elongation and changes in velocity of sound due to strain. Data are presented comparing a standard torque wrench to the ultrasonic monitor for different measured stresses on the bolt as well as for different bolt conditions. The strain instrument can be used to monitor changing stresses, to measure material properties and may be applied as a strain gage or load cell.

Heyman, J. S.↗

Ultrasonic evaluation of high voltage circuit boards

Preliminary observations indicate that an ultrasonic scanning technique may be useful as a quick, low cost, nondestructive method for judging the quality of circuit board materials for high voltage applications. Corona inception voltage tests were conducted on fiberglass-epoxy and fiberglass-polyimide high pressure laminates from 20 to 140 C. The same materials were scanned ultrasonically by utilizing the single transducer, through-transmission technique with reflector plate, and recording variations in ultrasonic energy transmitted through the board thickness. A direct relationship was observed between ultrasonic transmission level and corona inception voltage. The ultrasonic technique was subsequently used to aid selection of high quality circuit boards for the Communications Technology Satellite.

Klima, S. J.↗

Quantitative ultrasonic evaluation of engineering properties in metals, composites, and ceramics

Ultrasonic techniques that have demonstrated potential for material characterization are reviewed. These techniques rely on physical acoustic properties of materials and the interaction of elastic stress waves with morphological factors in the ultrasonic regime. The speed of wave propagation and energy loss by interaction with material microstructure and geometrical factors underlie ultrasonic determination of material properties. Two categories of ultrasonic measurements are discussed: those related to material strengths (e.g., elastic moduli, tensile strength, and fracture toughness) and those related to morphology and material conditions that govern strength and performance (e.g., microstructure, void content, residual stress, fatigue damage). It is shown that large-scale industrial application of ultrasonic NDE will depend on advancement in such areas as theory development, instrumentation, system automation, standardization, and coordination with design.

Vary, A.↗

Acousto-ultrasonic characterization of fiber reinforced composites

The acousto-ultrasonic technique combines advantageous aspects of acoustic emission and ultrasonic methodologies. Acousto-ultrasonics operates by introducing a repeating series of ultrasonic pulses into a material. The waves introduced simulate the spontaneous stress waves that would arise if the material were put under stress as in the case of acoustic emission measurements. These benign stress waves are detected by an acoustic emission sensor. The physical arrangement of the ultrasonic (input) transducer and acoustic emission (output) sensor is such that the resultant waveform carries an imprint of morphological factors that govern or contribute to material performance. The output waveform is complex, but it can be quantitized in terms of a 'stress wave factor.' The stress wave factor, which can be defined in a number of ways, is a relative measure of the efficiency of energy dissipation in a material. If flaws or other material anomalies exist in the volume being examined, their combined effect appears in the stress wave factor.

Vary, A.↗

Acousto-ultrasonic characterization of fiber reinforced composites

The acousto-ultrasonic technique combines advantageous aspects of acoustic emission and ultrasonic methodologies. Acousto-ultrasonics operates by introducing a repeating series of ultrasonic pulses into a material. The waves introduced simulate the spontaneous stress waves that would arise if the material were put under stress as in the case of acoustic emission measurements. These benign stress waves are detected by an acoustic emission sensor. The physical arrangement of the ultrasonic (input) transducer and acoustic emission (output) sensor is such that the resultant waveform carries an imprint of morphological factors that govern or contribute to material performance. The output waveform is quite complex, but it can be quantitized in terms of a 'stress wave factor'. The stress wave factor, which can be defined in a number of ways, is essentially a relative measure of the efficiency of energy dissipation in a material. If flaws or other material anomalies exist in the volume being examined, their combined effect will appear in the stress wave factor.

Vary, A.↗

Ultrasonic Mixing of Epoxy Curing Agents

New ultrasonic mixing technique used to mix several curing agents/epoxy combinations. Major component of commercially available base epoxy resin used in tetraglycidylmethylenedianiline (TGMDA). In ultrasonic mixing system cup holds resin and curing agent during acoustic excitation. Samples placed in cup with top to ultrasonic horn forming bottom of cup. Ultrasonically treated until amber colored and transparent. Because ultrasonic agitation drives out entrapped air, degassing not necessary before cure.

Hodges, W. T.↗