Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

47 records · Page 3

Unveiling Spatial and Temporal Dynamics of Plasmon-Enhanced Localized Fields in Metallic Nanoframes through Ultrafast Electron Microscopy

Plasmonic nanomaterials, particularly noble metal nanoframes (NFs), are important for applications such as catalysis, biosensing, and energy harvesting due to their ability to enhance localized electric fields and atomic efficiency via localized surface plasmon resonance (LSPR). Yet the fundamental structure-function relationships and plasmonic dynamics of the NFS are difficult to study experimentally and thus far rely predominately on computational methodologies, limiting their utilization. This study leverages the capabilities of ultrafast electron microscopy (UEM), specifically photon-induced near-field electron microscopy (PINEM), to probe the light-matter interactions within plasmonic NF structures. Here, the effects of shape, size, and plasmonic coupling of Pt@Au core-shell NFs on spatial and temporal characteristics of plasmon-enhanced localized electric fields are explored. Importantly, time-resolved PINEM analysis reveals that the plasmonic fields around hexagonal NF prisms exhibit a spatially dependent excitation and decay rate, indicating a nuanced interplay between the spatial geometry of the NF and the temporal evolution of the localized electric field. These results and observations uncover nanophotonic energy transfer dynamics in NFs and highlight their potential for applications in biosensing and photocatalysis.

Plasmonics↗

A compact tunable quadrupole lens for brighter and sharper ultra-fast electron diffraction imaging

In this article, we report our proof-of-principle design and experimental commissioning of a broadly tunable and low-cost transverse focusing lens system for MeV-energy electron beams. The lens system based on electromagnetic (EM) quadrupoles has been built as a part of the existing instrument for ultra-fast electron diffraction (UED) experiments at the Accelerator Test Facility II (ATF-II) at Brookhaven National Laboratory (BNL). We experimentally demonstrated the independent control of the size and divergence of the beam with the charge ranging from 1 to 13 pC. The charge density and divergence of the beam at the sample are the most important factors determining the quality of the Bragg-diffraction image (BDI). By applying the Robust Conjugate Directional Search (RCDS) algorithm for online optimization of the quadrupoles, the transverse beam size can be kept constant down to 75 µm from 1 to 13 pC. The charge density is nearly two orders of magnitude higher than the previously achieved value using a conventional solenoid. Using the BDI method we were able to extract the divergence of the beam in real-time and apply it to the emittance measurement for the first time. Our results agree well with simulations and with the traditional quadrupole scan method. The real-time divergence measurement opens the possibility of online optimization of the beam divergence (< 0.2 mrad) at the sample with the increased beam charge. This optimization is crucial for the future development of single-shot ultra-fast electron microscope (UEM). Finally, we demonstrated BDI with significant improvement, up to 3 times higher peak intensity and 2 times sharper Bragg-diffraction peaks at 13 pC. The charge is now limited by the laser power and increasing charge may improve the quality of BDI further. The capability we demonstrated here provides us with opportunities for new sciences using near-parallel, bright and ultrafast electron beams for single-shot imaging, to directly visualize the dynamics of defects and nanostructured materials, or even record molecular movie, which are impossible using present electron-beam technologies.

43 PARTICLE ACCELERATORS↗

A novel nondestructive diagnostic method for mega-electron-volt ultrafast electron diffraction

Abstract A real-time, nondestructive, Bragg-diffracted electron beam energy, energy-spread and spatial-pointing jitter monitor is experimentally verified by encoding the electron beam energy and spatial-pointing jitter information into the mega-electron-volt ultrafast electron diffraction pattern. The shot-to-shot fluctuation of the diffraction pattern is then decomposed to two basic modes, i.e., the distance between the Bragg peaks as well as its variation (radial mode) and the overall lateral shift of the whole pattern (drift mode). Since these two modes are completely decoupled, the Bragg-diffraction method can simultaneously measure the shot-to-shot energy fluctuation from the radial mode with 2·10 −4 precision and spatial-pointing jitter from the drift mode having wide measurement span covering energy jitter range from 10 −4 to 10 −1 . The key advantage of this method is that it allows us to extract the electron beam energy spread concurrently with the ongoing experiment and enables online optimization of the electron beam especially for future high charge single-shot ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) experiments. Furthermore, real-time energy measurement enables the filtering process to remove off-energy shots, improving the resolution of time-resolved UED. As a result, this method can be applied to the entire UED user community, beyond the traditional electron beam diagnostics of accelerators used by accelerator physicists.

43 PARTICLE ACCELERATORS↗

Imaging nanoscale spatial modulation of a relativistic electron beam with a MeV ultrafast electron microscope

Here, an accelerator-based MeV ultrafast electron microscope (MUEM) has been proposed as a promising tool to the study structural dynamics at the nanometer spatial scale and the picosecond temporal scale. Here, we report experimental tests of a prototype MUEM where high quality images with nanoscale fine structures were recorded with a pulsed ~3 MeV picosecond electron beam. The temporal and spatial resolutions of the MUEM operating in the single-shot mode are about 4 ps (FWHM) and 100 nm (FWHM), corresponding to a temporal-spatial resolution of 4 × 10 –19 sm, about 2 orders of magnitude higher than that achieved with state-of-the-art single-shot keV UEM. Using this instrument, we offer the demonstration of visualizing the nanoscale periodic spatial modulation of an electron beam, which may be converted into longitudinal density modulation through emittance exchange to enable production of high-power coherent radiation at short wavelengths. Our results mark a great step towards single-shot nanometer-resolution MUEMs and compact intense x-ray sources that may have widespread applications in many areas of science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stable Photoemission from the Wehnelt Aperture Surface in 4D Ultrafast Electron Microscopy

Here we show that photoemission with high long-term stability that is immediate and robust can be generated from the surface of the Wehnelt aperture in a TEG-based UEM. Further, we show that the resulting photobeam quality can be at least as good as that from LaB 6 , whether under photo or thermionic operation. We hypothesize that the energy distribution and the temporal properties of the beam are improved relative to LaB 6 owing to the closer match of photon energy to aperture work function.

36 MATERIALS SCIENCE↗

An X-Band Ultra-High Gradient Photoinjector

High brightness beams appealing for XFELs and UEM essentially imply a high current and a low emittance. To obtain such beams we propose to raise the accelerating voltage in the gun mitigating repealing Coulomb forces. An ultra-high gradient is achieved utilizing a short-pulse technology. We have designed a room temperature X-band 1,5 cell gun that is able to inject 4 MeV, 100 pC bunches with as low as 0.15 mcm normalized transverse emittance. The gun is operated with as high gradients as 400 MV/m and fed by 200 MW, 10 ns RF pulses generated with Argonne Wakefield Accelerator (AWA) power extractor. We report results of low RF power tests, laser alignment test results, and successful gun conditioning results carried out at nominal RF power.

43 PARTICLE ACCELERATORS↗

Implementation of ISO 50001 at Marine Corps Air Station Beaufort

The ISO 50001 implementation demonstration at U.S. Marine Corps Air Station (MCAS) Beaufort proved the feasibility of integrating an ISO 50001-conforming EnMS into existing command structures. The approach of leveraging external experts in gap analysis, EnMS training, and technical assistance were effective. In addition, strong leadership commitment and personnel resources were critical for success. Addressing typical personnel rotations by training newly rotated personnel and partnering key leadership positions in the EnMS structure with civilian counterparts can ensure program continuity. The project team brought forward many creative solutions that address the unique challenges for the Marine Corps and has paved the way for future Marine Corps EnMS implementations with example strategies and work products. Implementation of an ISO 50001 EnMS at additional Marine Corps facilities could provide for integration of base energy-related data systems and standardized energy reporting, using meaningful metrics for energy performance improvement. Beyond the energy performance improvement benefits of ISO 50001, widespread adoption of the standard at Marine Corps facilities would provide the communication and integration basis on which to reduce energy resiliency concern and could integrate energy service cyber security protections base wide. High levels of energy consumption, aggressive mandates from multiple sources, complex organizational structures, and constant personnel rotation make ISO 50001 a uniquely attractive proposition for the Marine Corps in support of the DoD’s overall energy strategy. The recently launched Energy Ethos and Unit Energy Manager (UEM) programs offer dynamic action-based programs over which ISO 50001 based business management can provide integrated governance of the Marine Corps installations’ energy programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing the UED beam line design via ImpactT simulation

The high charge low energy compressor system developed at NSLS-II can generate 5MeV electron bunches with 50pC charge (10 -8 electrons) focusing to 30 micron beam size and bunch length of order of 100 fs. NSLS-II plans to build it as part of the existing instrument for the ultra-fast electron diffraction (UED) and ultra-fast electron microscope (UEM) experiments to be installed at ATF-II, BNL. The expected intensity will be several orders of magnitudes higher than achieved previously using current technology (~10 -4 -10 -5 electrons). This type of accelerator based MeV electron microscopes, taking advantage of strong interaction of electrons with matter and overcoming space charge problem, are complementary to XFEL, such as LCLS.

36 MATERIALS SCIENCE↗

Report of the Basic Energy Sciences Workshop on the Future of Electron Sources, September 8-9, 2016

Electron sources represent an enabling technology for all cutting-edge applications of electron accelerators, two of the most notable ones being the X-ray free electron laser (FEL) and the electron microscope. FELs were enabled by the development of high-brightness electron sources, and they have changed the paradigm for a broad spectrum of scientific research. Electron microscopes have achieved sub-Å spatial resolution through the introduction of a cold field-emitter and aberration correction optics. Further development of these tools to atomic spatial and temporal resolutions is needed to advance atomic and molecular sciences to new levels of precision. Though the field of electron sources is quite mature, both revolutionary and evolutionary advances in electron sources are needed. On September 8-9, 2016, BES sponsored a Workshop on the Future of the Electron Source at SLAC National Accelerator Laboratory. The goal of the workshop was to define the electron source requirements for future XFELs, UED and UEM, and to identify future research and development (R&D) opportunities. More than sixty participants from U.S. national laboratories, academia, and international institutions attended the workshop. The workshop started with four plenary talks covering the status of electron sources, and highlighting the most urgent needs of future X-ray and electron scattering facilities. The talks made it evident that significant progress in electron sources will not only maximize the impact of current facilities, but also enable novel capabilities that can help maintain the U.S. leadership in X-ray and electron-based scattering instrumentation. Four breakout panels addressed the major technical areas of electron sources: (1) science and technology of electron generation, (2) continuous wave (CW) electron sources, (3) pulsed electron sources, and (4) exotic electron sources. Prior to the workshop, the panel co-chairs polled the panelists and other experts in the field and invited them to make recommendations on the most promising ways to advance the field of electron sources. During the workshop, each panel reviewed the proposals and novel ideas submitted. These summaries of the discussions on scientific needs and instrument requirements and their recommendations form the basis of this report.

43 PARTICLE ACCELERATORS↗

Tunable electron beam pulser for picoseconds stroboscopic microscopy in transmission electron microscopes

For two decades, time-resolved transmission electron microscopes (TEM) have relied on pulsed-laser photoemission to generate electron bunches to explore sub-microsecond to sub-picosecond dynamics. Despite the vast successes of photoemission time-resolved TEMs, laser-based systems are inherently complex, thus tend not to be turn-key. In this paper, we report on the successful retrofit of a commercial 200 keV TEM, without an external laser, capable of producing continuously tunable pulsed electron beams with repetition rates from 0.1 GHz up to 12 GHz and a tunable bunch length from tens of nanoseconds down to 10 ps. This innovation enables temporal access into previously inaccessible regimes: i.e., high repetition rate stroboscopic experiments. Combination of a pair of RF-driven traveling wave stripline elements, quadrupole magnets, and a variable beam aperture enables operation of the instrument in (1) continuous waveform (CW) mode as though the instrument was never modified (i.e. convention TEM operation mode, where the electrons from the emission cathode randomly arrive at the sample without resolvable time information), (2) stroboscopic (pump-probe) mode, and (3) pulsed beam mode for dose rate sensitive materials. In order to analyze the effect of a pulsed beam on image quality, we examined Au nanoparticles using bright field, high-resolution TEM imaging and selected area diffraction in both continuous and pulsed-beam mode. Furthermore, in comparison of conventional TEMs, the add-on beam pulser enables the observation of ultrafast dynamic behavior in materials that are reversible under synchronized excitation.

36 MATERIALS SCIENCE↗