Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Truth functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The use of zeolites to generate PET phantoms for the validation of quantification strategies in oncology

Purpose: In recent years, segmentation algorithms and activity quantification methods have been proposed for oncological {sup 18}F-fluorodeoxyglucose (FDG) PET. A full assessment of these algorithms, necessary for a clinical transfer, requires a validation on data sets provided with a reliable ground truth as to the imaged activity distribution, which must be as realistic as possible. The aim of this work is to propose a strategy to simulate lesions of uniform uptake and irregular shape in an anthropomorphic phantom, with the possibility to easily obtain a ground truth as to lesion activity and borders. Methods: Lesions were simulated with samples of clinoptilolite, a family of natural zeolites of irregular shape, able to absorb aqueous solutions of {sup 18}F-FDG, available in a wide size range, and nontoxic. Zeolites were soaked in solutions of {sup 18}F-FDG for increasing times up to 120 min and their absorptive properties were characterized as function of soaking duration, solution concentration, and zeolite dry weight. Saturated zeolites were wrapped in Parafilm, positioned inside an Alderson thorax-abdomen phantom and imaged with a PET-CT scanner. The ground truth for the activity distribution of each zeolite was obtained by segmenting high-resolution finely aligned CT images, on the basis of independently obtained volume measurements. The fine alignment between CT and PET was validated by comparing the CT-derived ground truth to a set of zeolites' PET threshold segmentations in terms of Dice index and volume error. Results: The soaking time necessary to achieve saturation increases with zeolite dry weight, with a maximum of about 90 min for the largest sample. At saturation, a linear dependence of the uptake normalized to the solution concentration on zeolite dry weight (R{sup 2}= 0.988), as well as a uniform distribution of the activity over the entire zeolite volume from PET imaging were demonstrated. These findings indicate that the {sup 18}F-FDG solution is able to saturate the zeolite pores and that the concentration does not influence the distribution uniformity of both solution and solute, at least at the trace concentrations used for zeolite activation. An additional proof of uniformity of zeolite saturation was obtained observing a correspondence between uptake and adsorbed volume of solution, corresponding to about 27.8% of zeolite volume. As to the ground truth for zeolites positioned inside the phantom, the segmentation of finely aligned CT images provided reliable borders, as demonstrated by a mean absolute volume error of 2.8% with respect to the PET threshold segmentation corresponding to the maximum Dice. Conclusions: The proposed methodology allowed obtaining an experimental phantom data set that can be used as a feasible tool to test and validate quantification and segmentation algorithms for PET in oncology. The phantom is currently under consideration for being included in a benchmark designed by AAPM TG211, which will be available to the community to evaluate PET automatic segmentation methods.

60 APPLIED LIFE SCIENCES↗

Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation

Purpose: Conventional (i.e., respiratory-correlated) 4DCT exploits the repetitive nature of breathing to provide an estimate of motion; however, it has limitations due to binning artifacts and irregular breathing in actual patient breathing patterns. The aim of this work was to evaluate the accuracy and image quality of a dynamic volume, CT approach (4D{sub vol}) using a 320-slice CT scanner to minimize these limitations, wherein entire image volumes are acquired dynamically without couch movement. This will be compared to the conventional respiratory-correlated 4DCT approach (RCCT). Methods: 4D{sub vol} CT was performed and characterized on an in-house, programmable respiratory motion phantom containing multiple geometric and morphological ''tumor'' objects over a range of regular and irregular patient breathing traces obtained from 3D fluoroscopy and compared to RCCT. The accuracy of volumetric capture and breathing displacement were evaluated and compared with the ground truth values and with the results reported using RCCT. A motion model was investigated to validate the number of motion samples needed to obtain accurate motion probability density functions (PDF). The impact of 4D image quality on this accuracy was then investigated. Dose measurements using volumetric and conventional scan techniques were also performed and compared. Results: Both conventional and dynamic volume 4DCT methods were capable of estimating the programmed displacement of sinusoidal motion, but patient breathing is known to not be regular, and obvious differences were seen for realistic, irregular motion. The mean RCCT amplitude error averaged at 4 mm (max. 7.8 mm) whereas the 4D{sub vol} CT error stayed below 0.5 mm. Similarly, the average absolute volume error was lower with 4D{sub vol} CT. Under irregular breathing, the 4D{sub vol} CT method provides a close description of the motion PDF (cross-correlation 0.99) and is able to track each object, whereas the RCCT method results in a significantly different PDF from the ground truth, especially for smaller tumors (cross-correlation ranging between 0.04 and 0.69). For the protocols studied, the dose measurements were higher in the 4D{sub vol} CT method (40%), but it was shown that significant mAs reductions can be achieved by a factor of 4-5 while maintaining image quality and accuracy. Conclusions: 4D{sub vol} CT using a scanner with a large cone-angle is a promising alternative for improving the accuracy with which respiration-induced motion can be characterized, particularly for patients with irregular breathing motion. This approach also generates 4DCT image data with a reduced total scan time compared to a RCCT scan, without the need for image binning or external respiration signals within the 16 cm scan length. Scan dose can be made comparable to RCCT by optimization of the scan parameters. In addition, it provides the possibility of measuring breathing motion for more than one breathing cycle to assess stability and obtain a more accurate motion PDF, which is currently not feasible with the conventional RCCT approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Autotune E+ Building Energy Models

This paper introduces a novel Autotune methodology under development for calibrating building energy models (BEM). It is aimed at developing an automated BEM tuning methodology that enables models to reproduce measured data such as utility bills, sub-meter, and/or sensor data accurately and robustly by selecting best-match E+ input parameters in a systematic, automated, and repeatable fashion. The approach is applicable to a building retrofit scenario and aims to quantify the trade-offs between tuning accuracy and the minimal amount of ground truth data required to calibrate the model. Autotune will use a suite of machine-learning algorithms developed and run on supercomputers to generate calibration functions. Specifically, the project will begin with a de-tuned model and then perform Monte Carlo simulations on the model by perturbing the uncertain parameters within permitted ranges. Machine learning algorithms will then extract minimal perturbation combinations that result in modeled results that most closely track sensor data. A large database of parametric EnergyPlus (E+) simulations has been made publicly available. Autotune is currently being applied to a heavily instrumented residential building as well as three light commercial buildings in which a de-tuned model is autotuned using faux sensor data from the corresponding target E+ model.

automatic calibration↗

Using Temporal Information from Human Mobility Data to Detect Anchor Points

Spatiotemporal mobility data are available in massive quantities, but large quantities of data typically include fewer variables or data fields. Often, the only available fields are User ID, Longitude, Latitude, Timestamp (ULLT). This raises an important question: how much can we infer about human mobility patterns using only these four fields? With ULLT data, we do not know individuals' socioeconomic status information or when they are visiting their anchor points (AP) or locations (such as homes, places of employment, or schools), and it is a modern challenge to use this data to infer these characteristics. When detecting anchor locations with limited input information, verification and validation (VV) are significant challenges. This paper addresses the problem of identifying individuals' anchor locations using only temporal information from spatiotemporal datasets with limited attributes. Our approach does not explicitly use latitude and longitude during analysis. Locationbased information is only employed in the preprocessing stage to identify periods of movement (trips) and stops (dwelling). Beyond this step, all analysis is based on temporal patterns. In theory, if stops and dwell times could be detected through alternative means, our method could function entirely without location-based input. We demonstrate this methodology on the 2017 National Household Travel Survey (NHTS) data, because it includes a carefully designed and collected time use survey with representative sampling and labeled ground truth. The high-quality survey data allows us to test the accuracy of our methods because NHTS contains intended place labels and agent/user characteristics. We have also applied our validated AP identification algorithm on very large-scale GPS based trajectory data for Patterns-of-Life (PoL) assessment and other applications, but due to space limit that could not be presented here.

McBride, Liz [ORNL] (ORCID:0000000286925869)↗

A comparison of deep-learning-based inpainting techniques for experimental X-ray scattering

The implementation is proposed of image inpainting techniques for the reconstruction of gaps in experimental X-ray scattering data. The proposed methods use deep learning neural network architectures, such as convolutional autoencoders, tunable U-Nets, partial convolution neural networks and mixed-scale dense networks, to reconstruct the missing information in experimental scattering images. In particular, the recovered pixel intensities are evaluated against their corresponding ground-truth values using the mean absolute error and the correlation coefficient metrics. The results demonstrate that the proposed methods achieve better performance than traditional inpainting algorithms such as biharmonic functions. Overall, tunable U-Net and mixed-scale dense network architectures achieved the best reconstruction performance among all the tested algorithms, with correlation coefficient scores greater than 0.9980.

97 MATHEMATICS AND COMPUTING↗

A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI

Purpose: To develop and evaluate a computerized semiautomatic segmentation method for accurate extraction of three-dimensional lesions from dynamic contrast-enhanced magnetic resonance images (DCE-MRIs) of the breast. Methods: The authors propose a new background distribution-based active contour model using level set (BDACMLS) to segment lesions in breast DCE-MRIs. The method starts with manual selection of a region of interest (ROI) that contains the entire lesion in a single slice where the lesion is enhanced. Then the lesion volume from the volume data of interest, which is captured automatically, is separated. The core idea of BDACMLS is a new signed pressure function which is based solely on the intensity distribution combined with pathophysiological basis. To compare the algorithm results, two experienced radiologists delineated all lesions jointly to obtain the ground truth. In addition, results generated by other different methods based on level set (LS) are also compared with the authors’ method. Finally, the performance of the proposed method is evaluated by several region-based metrics such as the overlap ratio. Results: Forty-two studies with 46 lesions that contain 29 benign and 17 malignant lesions are evaluated. The dataset includes various typical pathologies of the breast such as invasive ductal carcinoma, ductal carcinomain situ, scar carcinoma, phyllodes tumor, breast cysts, fibroadenoma, etc. The overlap ratio for BDACMLS with respect to manual segmentation is 79.55% ± 12.60% (mean ± s.d.). Conclusions: A new active contour model method has been developed and shown to successfully segment breast DCE-MRI three-dimensional lesions. The results from this model correspond more closely to manual segmentation, solve the weak-edge-passed problem, and improve the robustness in segmenting different lesions.

60 APPLIED LIFE SCIENCES↗

Machine learning based unfolding of x-ray spectra from filter stack spectrometer data

We demonstrate the application of neural networks to perform x-ray spectra unfolding from data collected by filter stack spectrometers. A filter stack spectrometer consists of a series of filter-detector pairs, where the detectors behind each filter measure the energy deposition through each layer as photo-stimulated luminescence (PSL). The network is trained on synthetic data, assuming x-rays of energies < 1 MeV and of two different distribution functions (Maxwellian and Gaussian) and the corresponding measured PSL values obtained from five different filter stack spectrometer designs. Predicted unfolds of single distributions are near identical reproductions of the ground truth spectra, with differences in the values lower than 20% at the higher energy end in some cases. The neural network has also demonstrated robustness to experimental measurement errors of < 5% and some capability of performing unfolds for linear combinations of the two distributions without previous training. The network can perform unfolds at rates > 1 Hz, ideal for application to some high-repetition-rate systems.

47 OTHER INSTRUMENTATION↗

SU-C-9A-01: Parameter Optimization in Adaptive Region-Growing for Tumor Segmentation in PET

Purpose: To design a reliable method to determine the optimal parameter in the adaptive region-growing (ARG) algorithm for tumor segmentation in PET. Methods: The ARG uses an adaptive similarity criterion m - fσ ≤ I-PET ≤ m + fσ, so that a neighboring voxel is appended to the region based on its similarity to the current region. When increasing the relaxing factor f (f ≥ 0), the resulting volumes monotonically increased with a sharp increase when the region just grew into the background. The optimal f that separates the tumor from the background is defined as the first point with the local maximum curvature on an Error function fitted to the f-volume curve. The ARG was tested on a tumor segmentation Benchmark that includes ten lung cancer patients with 3D pathologic tumor volume as ground truth. For comparison, the widely used 42% and 50% SUVmax thresholding, Otsu optimal thresholding, Active Contours (AC), Geodesic Active Contours (GAC), and Graph Cuts (GC) methods were tested. The dice similarity index (DSI), volume error (VE), and maximum axis length error (MALE) were calculated to evaluate the segmentation accuracy. Results: The ARG provided the highest accuracy among all tested methods. Specifically, the ARG has an average DSI, VE, and MALE of 0.71, 0.29, and 0.16, respectively, better than the absolute 42% thresholding (DSI=0.67, VE= 0.57, and MALE=0.23), the relative 42% thresholding (DSI=0.62, VE= 0.41, and MALE=0.23), the absolute 50% thresholding (DSI=0.62, VE=0.48, and MALE=0.21), the relative 50% thresholding (DSI=0.48, VE=0.54, and MALE=0.26), OTSU (DSI=0.44, VE=0.63, and MALE=0.30), AC (DSI=0.46, VE= 0.85, and MALE=0.47), GAC (DSI=0.40, VE= 0.85, and MALE=0.46) and GC (DSI=0.66, VE= 0.54, and MALE=0.21) methods. Conclusions: The results suggest that the proposed method reliably identified the optimal relaxing factor in ARG for tumor segmentation in PET. This work was supported in part by National Cancer Institute Grant R01 CA172638; The dataset is provided by AAPM TG211.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP3-01: Simultaneous PET Restoration and PET/CT Co-Segmentation Using a Variational Method

Purpose: PET images are usually blurred due to the finite spatial resolution, while CT images suffer from low contrast. Segment a tumor from either a single PET or CT image is thus challenging. To make full use of the complementary information between PET and CT, we propose a novel variational method for simultaneous PET image restoration and PET/CT images co-segmentation. Methods: The proposed model was constructed based on the Γ-convergence approximation of Mumford-Shah (MS) segmentation model for PET/CT co-segmentation. Moreover, a PET de-blur process was integrated into the MS model to improve the segmentation accuracy. An interaction edge constraint term over the two modalities were specially designed to share the complementary information. The energy functional was iteratively optimized using an alternate minimization (AM) algorithm. The performance of the proposed method was validated on ten lung cancer cases and five esophageal cancer cases. The ground truth were manually delineated by an experienced radiation oncologist using the complementary visual features of PET and CT. The segmentation accuracy was evaluated by Dice similarity index (DSI) and volume error (VE). Results: The proposed method achieved an expected restoration result for PET image and satisfactory segmentation results for both PET and CT images. For lung cancer dataset, the average DSI (0.72) increased by 0.17 and 0.40 than single PET and CT segmentation. For esophageal cancer dataset, the average DSI (0.85) increased by 0.07 and 0.43 than single PET and CT segmentation. Conclusion: The proposed method took full advantage of the complementary information from PET and CT images. This work was supported in part by the National Cancer Institute Grants R01CA172638. Shan Tan and Laquan Li were supported in part by the National Natural Science Foundation of China, under Grant Nos. 60971112 and 61375018.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-01: A Logistic Regression Model to Predict Objective Function Weights in Prostate Cancer IMRT

Purpose: To develop a statistical model that predicts optimization objective function weights from patient geometry for intensity-modulation radiotherapy (IMRT) of prostate cancer. Methods: A previously developed inverse optimization method (IOM) is applied retrospectively to determine optimal weights for 51 treated patients. We use an overlap volume ratio (OVR) of bladder and rectum for different PTV expansions in order to quantify patient geometry in explanatory variables. Using the optimal weights as ground truth, we develop and train a logistic regression (LR) model to predict the rectum weight and thus the bladder weight. Post hoc, we fix the weights of the left femoral head, right femoral head, and an artificial structure that encourages conformity to the population average while normalizing the bladder and rectum weights accordingly. The population average of objective function weights is used for comparison. Results: The OVR at 0.7cm was found to be the most predictive of the rectum weights. The LR model performance is statistically significant when compared to the population average over a range of clinical metrics including bladder/rectum V53Gy, bladder/rectum V70Gy, and mean voxel dose to the bladder, rectum, CTV, and PTV. On average, the LR model predicted bladder and rectum weights that are both 63% closer to the optimal weights compared to the population average. The treatment plans resulting from the LR weights have, on average, a rectum V70Gy that is 35% closer to the clinical plan and a bladder V70Gy that is 43% closer. Similar results are seen for bladder V54Gy and rectum V54Gy. Conclusion: Statistical modelling from patient anatomy can be used to determine objective function weights in IMRT for prostate cancer. Our method allows the treatment planners to begin the personalization process from an informed starting point, which may lead to more consistent clinical plans and reduce overall planning time.

60 APPLIED LIFE SCIENCES↗

Sequence Design of Random Heteropolymers as Protein Mimics

Random heteropolymers (RHPs) have been computationally designed and experimentally shown to recapitulate protein-like phase behavior and function. However, unlike proteins, RHP sequences are only statistically defined and cannot be sequenced. Recent developments in reversible-deactivation radical polymerization allowed simulated polymer sequences based on the well-established Mayo–Lewis equation to more accurately reflect ground-truth sequences that are experimentally synthesized. This led to opportunities to perform bioinformatics-inspired analysis on simulated sequences to guide the design, synthesis, and interpretation of RHPs. We compared batches on the order of 10000 simulated RHP sequences that vary by synthetically controllable and measurable RHP characteristics such as chemical heterogeneity and average degree of polymerization. Our analysis spans across 3 levels: segments along a single chain, sequences within a batch, and batch-averaged statistics. We discuss simulator fidelity and highlight the importance of robust segment definition. Examples are presented that demonstrate the use of simulated sequence analysis for in-silico iterative design to mimic protein hydrophobic/hydrophilic segment distributions in RHPs and compare RHP and protein sequence segments to explain experimental results of RHPs that mimic protein function. To facilitate the community use of this workflow, the simulator and analysis modules have been made available through an open source toolkit, the RHPapp.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrating very-high-resolution UAS data and airborne imaging spectroscopy to map the fractional composition of Arctic plant functional types in Western Alaska

Widespread changes in vegetation cover and composition are driving strong impacts on Arctic ecosystem functioning and global climate feedbacks. An accurate characterization of tundra vegetation composition is required to understand how the Arctic will respond to future climate change. However, quantifying tundra vegetation composition over large areas is challenging as commonly-used satellite observations are too coarse, spatially and spectrally, to differentiate low-lying tundra vegetation types. Recent airborne and spaceborne imaging spectroscopy platforms provide better data to characterize vegetation composition. Yet, our ability to characterize vegetation composition with imaging spectroscopy remains largely unexplored in the Arctic, particularly due to a lack of ground observations needed to train and test classification models. To address this problem, we collected very-high-resolution (VHR, ~5 cm) unoccupied aerial system (UAS) imagery at three low-Arctic tundra sites located on the Seward Peninsula, western Alaska. In this paper, we examine the feasibility of integrating imagery from the UAS and the hyperspectral Airborne Visible/Infrared Imaging Spectrometer, Next Generation (AVIRIS-NG) airborne instrument to map the fractional composition of 12 key Arctic plant functional types (PFTs). To this end, we first mapped the 12 PFTs from our VHR UAS imagery using random forest classification. We then used these UAS-derived PFT maps as ground truth to develop partial least squares regression (PLSR) models to predict the fractional cover (FCover) of each PFT from AVIRIS-NG imagery. Further, we evaluated the performance of our PLSR models using reserved UAS samples, as well as by mapping PFT FCover and dominant PFT for large tundra landscapes. Our results show that 1) Arctic PFTs can be effectively mapped using VHR UAS imagery, with overall accuracy between 86% and 92%, 2) when the UAS mapped PFTs were used to inform PLSR scaling models, the FCover of the 12 PFTs could be effectively estimated from AVIRIS-NG imagery with a mean absolute error (MAE) <0.13, and 3) our PLSR models outperformed traditional, fully constrained least-squares (FCLS) linear mixture analysis and produced high-quality, spatially contiguous PFT FCover and PFT maps that captured vegetation spatial patterns with similar accuracy to those developed from UAS imagery. The developed PLSR models have the potential to be broadly applied for quantifying vegetation composition with AVIRIS-NG images to help monitor tundra vegetation dynamics and improve process-based modeling of tundra ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Machine Learning Driven Contouring of High-Frequency Four-Dimensional Cardiac Ultrasound Data

Automatic boundary detection of 4D ultrasound (4DUS) cardiac data is a promising yet challenging application at the intersection of machine learning and medicine. Using recently developed murine 4DUS cardiac imaging data, we demonstrate here a set of three machine learning models that predict left ventricular wall kinematics along both the endo- and epi-cardial boundaries. Each model is fundamentally built on three key features: (1) the projection of raw US data to a lower dimensional subspace, (2) a smoothing spline basis across time, and (3) a strategic parameterization of the left ventricular boundaries. Model 1 is constructed such that boundary predictions are based on individual short-axis images, regardless of their relative position in the ventricle. Model 2 simultaneously incorporates parallel short-axis image data into their predictions. Model 3 builds on the multi-slice approach of model 2, but assists predictions with a single ground-truth position at end-diastole. To assess the performance of each model, Monte Carlo cross validation was used to assess the performance of each model on unseen data. For predicting the radial distance of the endocardium, models 1, 2, and 3 yielded average R2 values of 0.41, 0.49, and 0.71, respectively. Monte Carlo simulations of the endocardial wall showed significantly closer predictions when using model 2 versus model 1 at a rate of 48.67%, and using model 3 versus model 2 at a rate of 83.50%. These finding suggest that a machine learning approach where multi-slice data are simultaneously used as input and predictions are aided by a single user input yields the most robust performance. Subsequently, we explore the how metrics of cardiac kinematics compare between ground-truth contours and predicted boundaries. We observed negligible deviations from ground-truth when using predicted boundaries alone, except in the case of early diastolic strain rate, providing confidence for the use of such machine learning models for rapid and reliable assessments of murine cardiac function. To our knowledge, this is the first application of machine learning to murine left ventricular 4DUS data. Future work will be needed to strengthen both model performance and applicability to different cardiac disease models.

4D ultrasound↗

Development of a machine-learning-based ionic-force correction model for quantum molecular dynamic simulations of warm dense matter

In this work Δ learning is used to map orbital-free density functional theory (OF-DFT) ionic forces to the corresponding Kohn-Sham (KS) DFT ionic forces. The development of the approximate force difference in terms of the ion positions is constructed and serves as a stand in for the ground truth force difference. Descriptor vectors for ion configurations are constructed using all distance between ions in conjunction with an indexing based on a nearest neighbor ranking. It is demonstrated that such a scheme of descriptors can uniquely describe an ionic configuration up to a rotation and reflection when no ambiguity in the nearest neighbor ranking exists. How to handle the case when an ambiguity exists in the nearest neighbor ranking is discussed. As a proof of principle, the model is trained and tested on warm dense hydrogen at temperatures between 1 and 15 eV. Once tested, the model was used to perform molecular dynamic simulations of warm dense hydrogen. Furthermore, the resulting energies and pressures are within 1% and 2% of their respective target KS values.

36 MATERIALS SCIENCE↗

Template-based CTA to x-ray angio rigid registration of coronary arteries in frequency domain with automatic x-ray segmentation

Purpose: A key challenge for image guided coronary interventions is accurate and absolutely robust image registration bringing together preinterventional information extracted from a three-dimensional (3D) patient scan and live interventional image information. In this paper, the authors present a novel scheme for 3D to two-dimensional (2D) rigid registration of coronary arteries extracted from preoperative image scan (3D) and a single segmented intraoperative x-ray angio frame in frequency and spatial domains for real-time angiography interventions by C-arm fluoroscopy.Methods: Most existing rigid registration approaches require a close initialization due to the abundance of local minima and high complexity of search algorithms. The authors' method eliminates this requirement by transforming the projections into translation-invariant Fourier domain for estimating the 3D pose. For 3D rotation recovery, template Digitally Reconstructed Radiographs (DRR) as candidate poses of 3D vessels of segmented computed tomography angiography are produced by rotating the camera (image intensifier) around the DICOM angle values with a specific range as in C-arm setup. The authors have compared the 3D poses of template DRRs with the segmented x-ray after equalizing the scales in three domains, namely, Fourier magnitude, Fourier phase, and Fourier polar. The best rotation pose candidate was chosen by one of the highest similarity measures returned by the methods in these domains. It has been noted in literature that frequency domain methods are robust against noise and occlusion which was also validated by the authors' results. 3D translation of the volume was then recovered by distance-map based BFGS optimization well suited to convex structure of the authors' objective function without local minima due to distance maps. A novel automatic x-ray vessel segmentation was also performed in this study.Results: Final results were evaluated in 2D projection space for patient data; and with ground truth values and landmark distances for the images acquired with a solid phantom vessel. Results validate that rotation recovery in frequency domain is robust against differences in segmentations in two modalities. Distance-map translation is successful in aligning coronary trees with highest possible overlap.Conclusions: Numerical and qualitative results show that single view rigid alignment in projection space is successful. This work can be extended with multiple views to resolve depth ambiguity and with deformable registration to account for nonrigid motion in patient data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nalu-Wind and OpenFAST: A high-fidelity modeling and simulation environment for wind energy. Milestone ECP-Q2-FY19

The goal of the ExaWind project is to enable predictive simulations of wind farms comprised of many megawatt-scale turbines situated in complex terrain. Predictive simulations will require computational fluid dynamics (CFD) simulations for which the mesh resolves the geometry of the turbines and captures the rotation and large deflections of blades. Whereas such simulations for a single turbine are arguably petascale class, multi-turbine wind farm simulations will require exascale-class resources. The primary physics codes in the ExaWind project are Nalu-Wind, which is an unstructured-grid solver for the acoustically incompressible Navier-Stokes equations, and OpenFAST, which is a whole-turbine simulation code. The Nalu-Wind model consists of the mass-continuity Poisson-type equation for pressure and a momentum equation for the velocity. For such modeling approaches, simulation times are dominated by linear-system setup and solution for the continuity and momentum systems. For the ExaWind challenge problem, the moving meshes greatly affect overall solver costs as reinitialization of matrices and recomputation of preconditioners is required at every time step. This milestone represents the culmination of several parallel development activities towards the goal of establishing a full-physics simulation capability for modeling wind turbines operating in turbulent atmospheric inflow conditions. The demonstration simulation performed in this milestone is the first step towards the "ground truth" simulation and includes the following components: neutral atmospheric boundary layer inflow conditions generated using a precursor simulation, a hybrid RANS/LES simulation of the wall-resolved turbine geometry, hybridization of the turbulence equations using a blending function approach to transition from the atmospheric scales to the blade boundary layer scales near the turbine, fluid-structure interaction (FSI) that accounts for the complete set of blade deformations (bending, twisting and pitch motion, yaw and tower displacements) by coupling to a comprehensive turbine dynamics code (OpenFAST). The use of overset mesh methodology for the simulations in this milestone presents a significant deviation from the previous efforts where a sliding mesh approach was employed to model the rotation of the turbine blades. The choice of overset meshes was motivated by the need to handle arbitrarily large deformations of the blade and to allow for blade pitching in the presence of a controller and the ease of mesh generation compared to the sliding mesh approach. FSI and the new timestep algorithm used in the simulations were developed in partnership with the A2e High-Fidelity Modeling project. The individual physics components were verified and validated (V%V) through extensive code-to-code comparisons and with experiments where possible. The detailed V&V efforts provide confidence in the final simulation where these physics models were combined together even though no detailed experimental data is available to perform validation of the final configuration. Taken together, this milestone successfully demonstrated the most advanced simulation to date that has been performed with Nalu-Wind.

17 WIND ENERGY↗

Aerosol Plume Detection Algorithm Based on Image Segmentation of Scanning Atmospheric Lidar Data

An image-processing algorithm has been developed to identify aerosol plumes in scanning lidar backscatter data. The images in this case consist of lidar data in a polar coordinate system. Each full lidar scan is taken as a fixed image in time, and sequences of such scans are considered functions of time. The data are analyzed in both the original backscatter polar coordinate system and a lagged coordinate system. The lagged coordinate system is a scatterplot of two datasets, such as subregions taken from the same lidar scan (spatial delay), or two sequential scans in time (time delay). The lagged coordinate system processing allows for finding and classifying clusters of data. The classification step is important in determining which clusters are valid aerosol plumes and which are from artifacts such as noise, hard targets, or background fields. These cluster classification techniques have skill since both local and global properties are used. Furthermore, more information is available since both the original data and the lag data are used. Performance statistics are presented for a limited set of data processed by the algorithm, where results from the algorithm were compared to subjective truth data identified by a human.

97 MATHEMATICS AND COMPUTING↗

Predicting System Response at Unmeasured Locations

Traditional techniques to derive dynamic specification for components have a great deal of uncertainty. One of the major sources of uncertainty is that the number of response measurements in the operational system environment is insufficient to determine the component motion. This inadequacy is due to logistical limitations for data recording in field testing and space limitations for accelerometers, strain gages and associated wiring. Available measurements are often some distance from the component and therefore do not represent component motion. Typical straight-line envelopes of these unrepresentative measurements guarantee an increase in the uncertainty. In this paper multiple methods are attempted to expand a sparse set of field test measurements on a system to responses of interest that cannot be measured in the field due to the limitations. Proof of concept is demonstrated on the Modal Analysis Test Vehicle (MATV). The responses of interest, known as “truth responses”, are measured in a system vibration environment along with an optimized sparse set of 30 field responses. Methods to expand the field responses to the truth responses are demonstrated by comparing the acceleration spectral density of the expanded response to the measured response. Two methods utilize a validated finite element model of the MATV. One is developed from purely experiment based frequency response functions of a laboratory pre-test. Finally, these approaches are designed to drastically reduce the uncertainty of the component in-service motion as a basis for developing specifications that are guaranteed to be conservative with a known (instead of unknown) conservatism.

42 ENGINEERING↗