Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Transmission Line”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Performance analysis of radiation cooled dc transmission lines for high power space systems

As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on the power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

Schwarze, G. E.

Ground Isolation Circuit for Isolating a Transmission Line from Ground Interference

This invention relates generally to a system for isolating ground interference from a transmission line, e.g., a ground isolation circuit for isolating a wideband transmission signal (such as a video signal) from ground by modulating the base signal on a carrier signal to permit the transmission signal to be isolated. In one embodiment, the circuit includes a pair of matched mixer circuits, each of which receives a carrier signal from the same oscillator circuit. The first mixer circuit also receives the baseband signal input, after appropriate conditioning, and modulates the baseband signal onto the carrier signal. In a preferred embodiment the carrier signal has a predetermined frequency which is at least two times the frequency of the baseband signal. The modulated signal (which can comprise an rf signal) is transmitted via an rf transmission line to the second mixer, which demodulates the rf signal to recover the baseband signal. Each port of the mixer connects to an isolation transformer to ensure isolation from ground interference. The circuit is considered to be of commercial value in that it can provide isolation between transmitting and receiving circuits, e.g., ground isolation for television circuits or high frequency transmitters, without the need for video transformers or optical isolators, thereby reducing the complexity, power consumption, and weight of the system.

Davidson, Craig A.

Addendum to SAND2023-09604 Xyce lumped-element transmission line model verification to support Empire-Cable cable SGEMP analyses

This report supplements the Verification of Empire-Cable SAND report by expanding on the use of Xyce to simulate the coupling to a transmission line cable model. While Empire-Cable solves its governing equations on a high-order, finite-element mesh with an an implicit-in-time formulation, Xyce must use a first order graph for the circuit and explicit-in-time approach to be compatible with non-linear electrical device models. Thus, given the different solution methodologies in Xyce as compared to Empire-Cable, the convergence rates are expected to be different but the overall quality of the solution should be the same. The original four canonical problems studied in the Empire-Cable verification report are replicated here running in Xyce using transmission line modeling parameters from the verification report. Overall, agreement between the codes is excellent with Xyce’s convergence rates being limited mostly to first order due to the circuit network approximation of a transmission line being a first order approximation.

42 ENGINEERING

Experimental Analysis of Reduced-Sized Coplanar Waveguide Transmission Lines

An experimental investigation of the use of capacitive loading of coplanar waveguides to reduce their line length and, thus the size, of monolithic microwave integrated circuits is presented. The reduced sized coplanar waveguides are compared to unloaded transmission lines and to lumped element transmission line segments. The phase bandwidth, defined by 2 percent error in S(sub 21), and the return loss bandwidth, defined by a return loss greater than 15 dB, of coplanar waveguides reduced from 0 to 90 percent are compared, and the insertion loss as a function of the size reduction is presented.

Ponchak, George E.

Transmission line for S-band masers

Transmission-line is coaxial. Its outer conductor is made of thin-wall stainless-steel tube; inside is plated with 0.0025 mm copper and 0.0003 mm gold. This combination gives little microwave loss and adequate thermal isolation.

Clauss, R. C.

Microstrip-Transmission-Line Shock-Front Sensor

Microstrip-transmission-line sensor measures velocities of low-overpressure shock fronts and offers dynamic range needed for measurements both far from and near explosions. Fabricated easily, relatively inexpensive, and repaired in field. In addition, basic geometry modified easily, as needed.

Leiweke, Robert J.

Studying the Impact of Momentary Cessation of IBRs Compliant With IEEE Std. 2800-2022 on Transmission Line Protection Elements

This paper examines the impact of inverter-based resource (IBR) momentary cessation timing on transmission system protection relays. IEEE Std. 2800 mandates voltage ride-through, requiring IBRs to remain online during voltage disturbances. However, for severe voltage dips (|V| = 0.1 p.u.), the standard permits current blocking. In practice, vendors implement momentary cessation with varying delays, potentially affecting relay operation if IBRs cease too early. This article studies the impact of the time IBRs enter momentary cessation on transmission line protective relays. Using an electromagnetic transient (EMT) simulation, this study models IBR momentary cessation with tunable delays in a realistic transmission network. COMTRADE files generated from EMT simulations are analyzed in MATLAB using detailed protective relay models. Results indicate that IBRs must sustain operation for at least one cycle to ensure proper relay response; otherwise, relays may fail to oper- ate. These findings guide IBR vendors in optimizing momentary cessation settings to enhance transmission line protection.

24 POWER TRANSMISSION AND DISTRIBUTION

Transmission Line Based Sensor Design for FMCW Radar Processing of Collision Damage

This report presents a framework for transmission line ( T-L ) sensor design in Frequency Modulated Continuous Wave (FMCW) radar applications, with particular emphasis on modeling collision damage effects. Classical electromagnetic (EM) propagation theory is combined with impact mechanics to develop a model for analyzing transmission line behavior as a sensor under high-velocity impact conditions. The framework includes detailed mathematical derivations, spatial and temporal damage evolution models, and practical implementation considerations.

42 ENGINEERING

A transmission line phase stabilizer

To meet the phase stability requirements of certain experiments performed with the Deep Space Network, transmission lines carrying reference signals must be stabilized to reduce changes in their electrical length due to mechanical movement or changes in ambient temperature. A transmission line phase stabilizer being developed at JPL to perform this function is described.

Lutes, G. F.

Transmission line design for a power distribution system at 20 kHz for aircraft

A low inductance, low characteristic impedance transmission line was designed for a 20 kHz power distribution system. Several different conductor configurations were considered: strip lines, interdigitated metal ribbons, and standard insulated wires in multiwire configurations (circular and rectangular cylindrical arrangements). The final design was a rectangular arrangement of multiple wires of the same gauge with alternating polarities from wire to wire. This offered the lowest inductance per unit length (on the order of several nanohenries/meter) and the lowest characteristic impedance (on the order of one Ohm). Standard multipin connectors with gold-plated elements were recommended with this transmission line, the junction boxes to be internally connected with flat metal ribbons for low inductance, and the line to be constructed in sections of suitable length. Computer programs for the calculation of inductance of multiwire lines and of capacitances of strip lines were developed.

Zelby, L. W.

Reconfigurable Wave Velocity Transmission Lines for Phased Arrays

Phased array antennas showcase many advantages over mechanically steered systems. However, they are also more complex, heavy and most importantly costly. This presentation paper presents a concept which overcomes these detrimental attributes by eliminating all of the phase array backend (including phase shifters). Instead, a wave velocity reconfigurable transmission line is used in a series fed array arrangement to allow phase shifting with one small (100mil) mechanical motion. Different configurations of the reconfigurable wave velocity transmission line are discussed and simulated and experimental results are presented.

Beam Scanning

Low-Loss Microstrip Transmission Line Fabricated with Improved Liftoff Process

The µ-Spec integrated spectrometer operating at ~500 GHz, employs thin film superconducting Nb microstrip transmission lines deposited directly on a thin (450 nm) single-crystal silicon dielectric. This single-crystal silicon layer is chosen as the dielectric layer due to its low intrinsic loss, with the goal of achieving both high- efficiency and precise phase control in a compact spectrometer architecture. To avoid roughening or etching through the thin single-crystal silicon dielectric a liftoff technique was developed for patterning these microstrip transmission lines and ground plane structures. This two- layer liftoff process was designed for use with sputter deposition and resulted in a US patent. Although this original technique provided precise control of linewidth, results of initial prototype spectrometer devices and separate diagnostic co-planer waveguide resonator devices showed that unexpected loss was being introduced due to the lift-off process. This extra loss was believed to be due to the “tails” (thin tapered regions) at the edge of the metal traces resulting from the sputtering process, as well as an amorphous oxide layer at the Nb-Si interface. We have since demonstrated an improved lift-off technique, which provides a clean metal-Si interface and removes the loss-inducing tails by a two-step selective etching method. This results in a decrease in microwave loss by more than an order of magnitude when measured in co-planar waveguide microwave resonator structures. We present these microwave test results and also SEM and TEM images of the microstrip interfaces and edge profiles before and after application of the improved process.

Hess, Larry A.

Finite Ground Coplanar (FGC) Waveguide: A Better Transmission Line for Microwave Circuits

A new version of coplanar waveguide (CPW) with electrically narrow ground strips 14 has been developed for microwave integrated circuits. This transmission line, referred to by Finite Ground Coplanar (FGC) waveguide, has several advantages over conventional coplanar waveguide. Since the ground strips are narrow, parasitic resonances that develop when the CPW is placed on a carrier or in a package are eliminated. In addition, the narrow ground strips permit the integration of lumped and distributed circuit elements in the ground strips as well as in the center strip to reduce the circuit size and improve its performance. Finally, the coupling between adjacent FGC transmission lines is lower than the coupling between CPW lines for the same spacing between the lines. All of these attributes of FGC are presented in this paper.

Ponchak, George E.