Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transition Edge Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Multitone harmonic-balance simulations of an x-ray transition-edge sensor characterized at BESSY II

We present multitone harmonic-balance (MTHB) simulations of a Ti-Au x-ray transition-edge sensor (TES) microcalorimeter in a 5x5 pixel spectrometer array. The dynamic response of the TES microcalorimeter under simulation has been extremely well characterized at the BESSY II Synchrotron Radiation Facility in Berlin. We compare our simulated results directly with these measurements, and show that the MTHB algorithm is able to simulate to great accuracy the dynamic behavior of the TES, even when saturated by 6 keV photons. In this paper, we provide a detailed account of the MTHB simulations, and discuss the impact of this work on future missions such as the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-ray spectroscopy with transition-edge sensors at Stanford Synchrotron Radiation Lightsource beamline 10-1

We present results obtained with a new soft X-ray spectrometer based on transition-edge sensors (TESs) composed of Mo/Cu bilayers coupled to bismuth absorbers. This spectrometer simultaneously provides excellent energy resolution, high detection efficiency, and broadband spectral coverage. The new spectrometer is optimized for incident X-ray energies below 2 keV. Each pixel serves as both a highly sensitive calorimeter and an X-ray absorber with near unity quantum efficiency. We have commissioned this 240-pixel TES spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 10-1 (BL 10-1) and used it to probe the local electronic structure of sample materials with unprecedented sensitivity in the soft X-ray regime. As mounted, the TES spectrometer has a maximum detection solid angle of 2 × 10 –3 sr. The energy resolution of all pixels combined is 1.5 eV full width at half maximum at 500 eV. We describe the performance of the TES spectrometer in terms of its energy resolution and count-rate capability and demonstrate its utility as a high throughput detector for synchrotron-based X-ray spectroscopy. Here, the results from initial X-ray emission spectroscopy and resonant inelastic X-ray scattering experiments obtained with the spectrometer are presented.

47 OTHER INSTRUMENTATION↗

Characterization of Transition Edge Sensors for the Simons Observatory

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama Desert in Chile to observe the cosmic microwave background CMB radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were taken both with 4-lead resistance measurements and with a time-domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current versus voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Lastly, normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.

47 OTHER INSTRUMENTATION↗

Commercialization of Micro-fabrication of Antenna-Coupled Transition Edge Sensor Bolometer Detectors for Studies of the Cosmic Microwave Background

In this work, we report on the development of commercially fabricated multichroic antenna-coupled transition edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments. CMB polarimetry experiments have deployed instruments in stages. Additionally, stage II experiments deployed with O(1000) detectors and reported successful detection of B-mode (divergence-free) polarization pattern in the CMB. Stage III experiments have recently started observing with O(10,000) detectors with wider frequency coverage. A concept for a stage IV experiment, CMB-S4, is emerging to make a definitive measurement of CMB polarization from the ground with O(400,000) detectors. The orders of magnitude increase in detector count for CMB-S4 require a new approach in detector fabrication to increase fabrication throughput and reduce the cost. We report on collaborative efforts with two commercial micro-fabrication foundries to fabricate antenna-coupled TES bolometer detectors. The detector design is based on the sinuous antenna-coupled dichroic detector from the POLARBEAR-2 experiment. The TES bolometers showed the expected I–V response, and the RF performance agrees with the simulation. We will discuss the motivation, design consideration, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Recent Developments of Commercially Fabricated Horn Antenna-Coupled Transition-Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiments

Here we report on the successful fabrication of orthomode transducer-coupled transition-edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments with the superconductor electronics fabrication facility at SEEQC Inc. Commercial microfabrication foundry could provide increase in detector fabrication throughput for a next-generation CMB experiment, CMB-S4, that would deploy approximately one order of magnitude more detectors than current CMB experiments. We also developed TES bolometers with two TESs in series that have two different superconducting temperatures (Tc) using a superconducting proximity effect between niobium (Nb) and aluminum-manganese (AlMn) alloy. We will discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments and other experiments that require TESs and superconducting RF circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

White noise of Nb-based microwave superconducting quantum interference device multiplexers with NbN coplanar resonators for readout of transition edge sensors

White noise of dissipationless microwave radio frequency superconducting quantum interference device (RF-SQUID) multiplexers has been experimentally studied to evaluate their readout performance for transition edge sensor (TES) photon counters ranging from near infrared to gamma ray. The characterization has been carried out at 4 K, first to avoid the low-frequency fluctuations present at around 0.1 K, and second, for a feasibility study of readout operation at 4 K for extended applications. To increase the resonant Q at 4 K and maintain low noise SQUID operation, multiplexer chips consisting of niobium nitride (NbN)-based coplanar-waveguide resonators and niobium (Nb)-based RF-SQUIDs have been developed. This hybrid multiplexer exhibited 1 × 10{sup 4} ≤ Q ≤ 2 × 10{sup 4} and the square root of spectral density of current noise referred to the SQUID input √S{sub I} = 31 pA/√Hz. The former and the latter are factor-of-five and seven improvements from our previous results on Nb-based resonators, respectively. Two-directional readout on the complex plane of the transmission component of scattering matrix S{sub 21} enables us to distinguish the flux noise from noise originating from other sources, such as the cryogenic high electron mobility transistor (HEMT) amplifier. Systematic noise measurements with various microwave readout powers P{sub MR} make it possible to distinguish the contribution of noise sources within the system as follows: (1) The achieved √S{sub I} is dominated by the Nyquist noise from a resistor at 4 K in parallel to the SQUID input coil which is present to prevent microwave leakage to the TES. (2) The next dominant source is either the HEMT-amplifier noise (for small values of P{sub MR}) or the quantization noise due to the resolution of 300-K electronics (for large values of P{sub MR}). By a decrease of these noise levels to a degree that is achievable by current technology, we predict that the microwave RF-SQUID multiplexer can exhibit √S{sub I} ≤ 5 pA/√Hz, i.e., close to √S{sub I} of state-of-the-art DC-SQUID-based multiplexers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A temperature-induced hysteretic behavior of resistivity and magnetoresistance of electrodeposited bismuth microbridges for X-ray transition-edge sensor absorbers

This study investigates the temperature-induced hysteretic behavior of resistivity and magnetoresistance in electrodeposited bismuth films, with a focus on their application as absorbers in transition-edge sensors (TESs) for X-ray detection. Through a series of resistivity versus temperature measurements from room temperature to a few Kelvin, we explore the change in the conductive behavior of bismuth electrodeposited on various substrates. Our findings show for the first time both hysteretic and irreversible changes in resistivity as a function of temperature. Further, magnetoresistance measurements reveal notable variations in resistance behavior under different magnetic fields, highlighting the impact of magnetic fields on these films’ electronic transport properties, with an indication of potential weak anti-localization effects at the lowest temperatures. This study not only provides a deeper understanding of bismuth’s conductivity characteristics at low temperatures but also sheds light on the practical implications for developing more effective TESs for synchrotron X-ray facilities.

42 ENGINEERING↗

Resonant Soft X-Ray Scattering from Stripe-Ordered La 2 - x Ba x Cu O 4 Detected by a Transition-Edge Sensor Array Detector

Resonant soft x-ray scattering (RSXS) is a leading probe of valence-band order in materials best known for detecting charge-density-wave order in copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background, which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the study of weak signals such as diffuse scattering from glassy or fluctuating order that is spread widely over momentum space. Recent advances in superconducting transition-edge-sensor (TES) detectors have led to major improvements in energy resolution and detection efficiency in the soft x-ray range. Here, we perform a RSXS study of stripe-ordered La 2 - x Ba x Cu O 4 at the Cu L 3 / 2 edge (932.2 eV) using a TES detector with 1.5-eV resolution, to evaluate its utility for mitigating the fluorescence-background problem. We find that, for suitable degree of detuning from the resonance, the TES rejects the fluorescence background, leading to a five to ten times improvement in the statistical quality of the data compared to an equivalent, energy-integrated measurement. We conclude that a TES introduces a promising method to reducing background in RSXS studies and may lead to discoveries in materials exhibiting valence-band order that is fluctuating or glassy.

36 MATERIALS SCIENCE↗

An analytical model for pulse shape and electrothermal stability in two-body transition-edge sensor microcalorimeters

High-resolution superconducting gamma-ray sensors show potential for the more accurate analysis of nuclear material. These devices are part of a larger class of microcalorimeters and bolometers based on transition edge sensors (TESs) that have two distinct thermal bodies. We derive the time domain behavior of the current and temperature for compound TES devices in the small signal limit and demonstrate the utility of these equations for device design and characterization. In particular, we use the model to fit pulses from our gamma-ray microcalorimeters and demonstrate how critical damping and electrothermal stability can be predicted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the 240 Pu/ 239 Pu mass ratio using a transition-edge-sensor microcalorimeter for total decay energy spectroscopy

In this study, we have developed a new category of sensor for measurement of the 240 Pu/ 239 Pu mass ratio from aqueous solution samples with advantages over existing methods. Aqueous solution plutonium samples were evaporated and encapsulated inside of a gold foil absorber, and a superconducting transition-edge-sensor microcalorimeter detector was used to measure the total reaction energy (Q-value) of nuclear decays via heat generated when the energy is thermalized. Since all of the decay energy is contained in the absorber, we measure a single spectral peak for each isotope, resulting in a simple spectral analysis problem with minimal peak overlap. We found that mechanical kneading of the absorber dramatically improves spectral quality by reducing the size of radioactive inclusions within the absorber to scales below 50 nm such that decay products primarily interact with atoms of the host material. Due to the low noise performance of the microcalorimeter detector, energy resolution values of 1 keV fwhm (full width at half-maximum) at 5.5 MeV have been achieved, an order of magnitude improvement over α-spectroscopy with conventional silicon detectors. We measured the 240 Pu/ 239 Pu mass ratio of two samples and confirmed the results by comparison to mass spectrometry values. These results have implications for future measurements of trace samples of nuclear material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-β decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work, we showcase light detectors based on an alternative Ir-Pt bilayer transition-edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of < 100 eV rms. Our detectors have risetimes of approximately 180μs and measured timing jitter of < 20μs for the expected signal to noise at the Q value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-β decay pile-up events. In conclusion, the current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Controlled Shifts of X-ray Emission Lines Measured with Transition Edge Sensors at the Advanced Photon Source

The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce controlled eV-scale shifts of a narrow line in between fixed-energy fluorescence lines. We use this to characterize the ability of a hard X-ray superconducting Transition Edge Sensor (TES) array to measure line shifts. Fixed fluorescence lines excited by higher harmonics of the monochromatic X-ray beam are used for online energy calibration, while elastic scattering from the primary harmonic acts as the variable energy emission line under study. We use this method to demonstrate the ability to track shifts in the energy of the elastic scattering line of magnitude smaller than the TES energy resolution, and find we are ultimately limited by our calibration procedure. The method can be applied over a wide X-ray energy range and provides a robust approach for the characterization of the ability of high-resolution detectors to detect X-ray emission line shifts, and the quantitative comparison of energy calibration procedures.

Guruswamy, Tejas (ORCID:0000000241656765)↗

L-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array

Here, we present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements then demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100–2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential

X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low efficiency of wavelength-dispersive X-ray spectrometer technology has limited the use of XES, especially in combination with weaker laboratory X-ray sources. More efficient energy-dispersive detectors have either insufficient energy resolution because of the statistical limits described by Fano or too low counting rates to be of practical use. This paper updates an approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs). TES arrays are discussed and compared with conventional methods, and shown under which circumstances they are superior. It is also shown that a TES array can be integrated into a table-top time-resolved X-ray source and a soft X-ray synchrotron beamline to perform emission spectroscopy with good chemical sensitivity over a very wide range of energies.

Uhlig, J.↗

Development of Holmium-163 electron-capture spectroscopy with transition-edge sensors

Calorimetric decay energy spectroscopy of electron-capture-decaying isotopes is a promising method to achieve the sensitivity required for electron neutrino mass measurement. The very low total nuclear decay energy (Q EC < 3 keV) and short half-life (4570 years) of 163 Ho make it attractive for high-precision electron-capture spectroscopy (ECS) near the kinematic endpoint, where the neutrino momentum goes to zero. In the ECS approach, an electron-capture-decaying isotope is embedded inside a microcalorimeter designed to capture and measure the energy of all the decay radiation except that of the escaping neutrino. We have developed a complete process for proton irradiation-based isotope production, isolation, and purification of 163 Ho. We have developed transition-edge sensors for this measurement and methods for incorporating 163 Ho into high-resolution microcalorimeters, and have measured the electron-capture spectrum of 163 Ho. Finally, we present our work in these areas and discuss the measured spectrum and its comparison to current theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗