Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transfer Function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Estimating Contrast Transfer Function and Associated Parameters by Constrained Nonlinear Optimization

The three-dimensional reconstruction of macromolecules from two-dimensional single-particle electron images requires determination and correction of the contrast transfer function (CTF) and envelope function. A computational algorithm based on constrained non-linear optimization is developed to estimate the essential parameters in the CTF and envelope function model simultaneously and automatically. The application of this estimation method is demonstrated with focal series images of amorphous carbon film as well as images of ice-embedded icosahedral virus particles suspended across holes.

97 MATHEMATICS AND COMPUTING↗

Binary pseudo-random gratings and arrays for calibration of the modulation transfer function of surface profilometers: recent developments

The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all available objectives. The effects of fabrication imperfections on the efficiency of calibration are also discussed.

47 OTHER INSTRUMENTATION↗

The Sensitivity of Chemical Kinetic Models on Flame Transfer Functions in Acoustic Fluctuation Environments with Varying Equivalence Ratios

Various factors affect the heat release response of flames – thermodynamics, hydrodynamics, acoustics, etc. The coupling of heat release rate and acoustics, in particular, is essential to the design of combustion devices so as to avoid adverse effects during their operation. Modeling flames in acoustic environments requires an accurate understanding of the fundamental physics that occurs when flames interact with a fluctuating pressure field. Over the past couple of decades, researchers have been quantifying the impact of this fluctuating pressure field on the unsteady heat release rate. The flame transfer functions computed have also been shown to depend on the level of detail in the chemical kinetic model. This paper attempts to bridge the gap between these studies to understand how sensitive the flame transfer function is to various kinetic models. The problem is studied by performing multiple one-dimensional simulations using the low-Mach solver NGA. The detailed GRI-Mech 3.0 will be used for comparison. Also, the pressure amplitude and reactant equivalence ratio are varied to understand how the environment affects this sensitivity.

Girdhar, Anant↗

Fast baryonic field painting for Sunyaev-Zel’dovich analyses: Transfer function vs hybrid effective field theory

Here, we present two approaches for “painting” baryonic properties relevant to the Sunyaev-Zel’dovich (SZ) effect—optical depth and Compton-y—onto three-dimensional N-body simulations, using the MillenniumTNG suite as a benchmark. The goal of these methods is to produce fast and accurate reconstruction methods to aid future analyses of baryonic feedback using the SZ effect. The first approach employs a Gaussian process emulator to model the SZ quantities via a transfer function, while the second utilizes hybrid effective field theory (HEFT) to reproduce these quantities within the simulation. Our analysis involves comparing both methods to the true MillenniumTNG optical depth and Compton-y fields using several metrics, including the cross-correlation coefficient, power spectrum, and power spectrum error. Additionally, we assess how well the reconstructed fields correlate with dark matter haloes across various mass thresholds. The results indicate that the transfer function method yields more accurate reconstructions for fields with initially high correlations (r ≈ 1), such as between the optical depth and dark matter fields. Conversely, the HEFT-based approach proves more effective in enhancing correlations for fields with weaker initial correlations (r ∼ 0.5), such as between the Compton-y and dark matter fields. Lastly, we discuss extensions of our methods to improve the reconstruction performance at the field level.

Liu, R. Henry [University of California, Berkeley,↗

Dark Energy Survey Year 3 Results: Measuring the Survey Transfer Function with Balrog

Abstract We describe an updated calibration and diagnostic framework, Balrog , used to directly sample the selection and photometric biases of the Dark Energy Survey (DES) Year 3 (Y3) data set. We systematically inject onto the single-epoch images of a random 20% subset of the DES footprint an ensemble of nearly 30 million realistic galaxy models derived from DES Deep Field observations. These augmented images are analyzed in parallel with the original data to automatically inherit measurement systematics that are often too difficult to capture with generative models. The resulting object catalog is a Monte Carlo sampling of the DES transfer function and is used as a powerful diagnostic and calibration tool for a variety of DES Y3 science, particularly for the calibration of the photometric redshifts of distant “source” galaxies and magnification biases of nearer “lens” galaxies. The recovered Balrog injections are shown to closely match the photometric property distributions of the Y3 GOLD catalog, particularly in color, and capture the number density fluctuations from observing conditions of the real data within 1% for a typical galaxy sample. We find that Y3 colors are extremely well calibrated, typically within ∼1–8 mmag, but for a small subset of objects, we detect significant magnitude biases correlated with large overestimates of the injected object size due to proximity effects and blending. We discuss approaches to extend the current methodology to capture more aspects of the transfer function and reach full coverage of the survey footprint for future analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

No Galaxy Left Behind: Measuring the Transfer Function of the Dark Energy Survey with Balrog

In this dissertation, we describe a calibration and diagnostic framework called Balrog which was used to directly sample the selection and photometric biases of the Dark Energy Survey (DES) Year 3 (Y3) dataset. We systematically inject onto the single-epoch images of a random 20% subset of the DES footprint an ensemble of nearly 30 million realistic galaxy models derived from DES Deep Field observations. These augmented images are analyzed in parallel with the original data to automatically inherit measurement systematics that are often too difficult to capture with traditional generative models. The resulting object catalog is a Monte Carlo sampling of the DES transfer function and is used as a powerful diagnostic and calibration tool for a variety of DES Y3 science, particularly for the calibration of the photometric redshifts of distant "source" galaxies and magnification biases of nearer "lens" galaxies. The recovered Balrog injections are shown to closely match the photometric property distributions of the fiducial Y3 GOLD catalog, particularly in color, and capture the number density fluctuations from observing conditions of the real data within 1% for a typical galaxy sample. We find that Y3 colors are extremely well calibrated, typically within ~1-8 millimagnitudes, but for a small subset of objects we detect significant magnitude biases correlated with large overestimates of the injected object size due to proximity effects and blending. Finally, we discuss approaches to extend the current methodology to capture more aspects of the transfer function for future analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-I-17: Comparison of Two Novel Algorithms for the Modulation Transfer Function of CT Using a Simple Cylindrical Phantom

Purpose: To compare and analyze two novel algorithms for the assessment of modulation transfer functions (MTFs) of computed tomography (CT) systems using a simple acrylic cylindrical phantom Method and Materials: Images of the acrylic cylindrical phantom were acquired by a GE LightSpeed 16 RT (GE Healthcare, Milwaukee, WI) using 120 kVp, 330 mA, 2.5 mm slice thickness, 10 cm field-of view (FOV), four reconstruction kernels (e.g. standard, soft, detail, bone, and lung). Two different algorithms were used to analyze images for MTF assessment. First, Richard et al. suggested a task-based MTF assessment method through an edge spread function (ESF) which described pixel intensities as a function of distance from the center. The MTF was obtained as the absolute value of Fourier transform of the differentiated ESF. Second, Ohkubo et al. devised an effective method to determine the point spread function (PSF) of CT system accompanied with verification. The line spread function (LSF), which was the one-dimensional integration of the PSF, was used to obtain the MTF. We validated the reliability of two above-mentioned methods through the comparison with a conventional method using a thin tungsten wire phantom. Results: The measured MTFs by two methods were mostly similar each other for standard, soft, and detail kernels. In 0.6 lp/mm, the MTF difference between two methods were 0.012(standard), 0.004(soft), and 0.037(detail). They also coincided with the MTF by the conventional method well. However, there were considerable distinctions for bone and lung kernels containing edge enhancement that might cause undershoots near the peak of the LSF. Conclusions: We compared two novel methods to assess task-based MTFs for clinical CT systems especially using a simple acrylic cylindrical phantom with high-convenience and low-cost, and validated them against a conventional method. This work can provide a practical solution to users for the quality assurance of CT.

60 APPLIED LIFE SCIENCES↗

Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transfer functions for Q A /Q B international regulatory limits for the safe transport of radioactive materials

This paper presents a proposed revision of the International Atomic Energy Agency transport regulations, related to the A 1 and A 2 limit values used to determine the radioactive transport classification. Based on the 'Q system', a novel methodology was introduced to derive Q A and Q B values related to scenarios involving external exposure from a distant source. These values are key parameters that respectively represent the total effective dose and total equivalent dose to the skin, from all primary and secondary particles contributing to radiation exposure. The International Working Group (WG A 1 /A 2 ) is established and associated with the TRANSSC Technical Expert Group on Radiation Protection. A review of the A 1 and A 2 values is performed in response to identified limitations within the existing Q system. The followed approach is based on Monte Carlo simulations that enabled the development of transfer functions aimed at reducing computational time and increasing the flexibility of dose evaluations for any radionuclide with known particle emission spectra. This method allows updating the Q A and Q B values to account for future data evolutions (decay data, fluence-to-dose conversion coefficients) and standardizing the calculation of regulation limits across all referenced radionuclides and scenarios related to external exposure. The transfer functions are established using three Monte Carlo simulation codes—FLUKA, Geant4, and MCNP—and address the previous limitations of the 'Q system', reflecting the latest International Commission for Radiation Protection recommendations and improvements in calculation techniques. The results of the WG show consistent agreement across the codes, with minor discrepancies observed at low primary energies due to statistical uncertainties and different handling of stopping power for electrons/positrons in the codes. This revised approach aligns with current standards and recommendations, ensuring that the radiological consequences of transport accidents are acceptable for the new A 1 and A 2 limits from a radiological protection perspective.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-D-204-02: Novel Method for Correcting Degradation of Sharpness of Liquid-Crystal Display Based On Modulation Transfer Function

Purpose: To develop a method for improving sharpness of images reproduced on liquid-crystal displays (LCDs) by compensating for the degradation of modulation transfer function (MTF) of the LCD. Methods: The inherent MTF of a color LCD (display MTF) was measured using a commercially available color digital camera. The frequency responses necessary to compensate for the resolution property of the LCD were calculated from the inverses of the display MTFs in both the horizontal and vertical directions. In addition, the inverses of the display MTFs were combined with the response of the human eye. The finite impulse response (FIR) filters were computed by taking the inverse Fourier transform of the frequency responses, and the effects of the FIR filtering on both the resolution and noise properties of the displayed images were verified by measuring the MTF and Wiener spectrum (WS), respectively. The FIR filtering was then applied to the representation of digital bone and chest radiographs. Results: The FIR filtering improved the MTF values by up to almost 1.0 or greater over the frequency range of interest, while it minimally increased the WS values. Combining the inverses of the display MTFs with the response of the human eye led to further refinement of the MTF. Our method was successfully and beneficially applied to the image interpretation of bone radiographs. The resolution enhancement of chest radiographs, which include larger scattered radiation than bone radiographs, was easily perceived by incorporating the response of the human eye. In addition, no artifacts were observed on the processed images. Conclusion: Our proposed method to compensate for the degradation of the resolution properties of LCDs has the potential to improve the observer performance of radiologists when reading digital radiographs. This work was supported in part by grant from EIZO Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the modulation transfer function for X-ray radiography in high energy density experiments

Here, the Modulation Transfer Function ( MTF ) is an established means for characterizing imaging performance of X-ray radiography systems. We report on experiments using high energy, laser-driven X-ray radiography systems that assess performance using MTF values measured with the knife-edge projection method. The broadband, hard X-ray systems under study use line-projection imaging produced by narrowing the laser-generated X-ray source with a slit. We find that good contrast resolution can be achieved (the MTF = 0.5 at 75 μm wavelength) and that this performance is reproduced on different laser facilities. We also find that the MTF is sensitive both to the thickness of the line-projection slit and to the backing material thickness under the knife-edge. Both these sensitivities are due to a common mechanism, namely induced changes in the spectrally-averaged spatial widths of the X-ray source. The same line-projection system is also used on experimental campaigns measuring Rayleigh-Taylor instability growth by dynamically imaging sinusoidal, high Z micro-targets with wavelengths of 100 μm or less. By applying the measured MTF values to correct the ripple target contrast measurements, we can predict ripple growth to approximately 10% accuracy.

47 OTHER INSTRUMENTATION↗

A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems

Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of measuring the temporal MTF under fluoroscopic conditions using a moving slanted edge, a generalization of the slanted-edge method used to measure the (spatial) MTF, providing the temporal MTF of the entire imaging system. The method uses a single x-ray exposure, constant edge velocity, and assumes spatial and temporal blurring are separable. The method was validated on a laboratory x-ray image intensifier (XRII) system by comparison with direct measurements of the XRII optical response, showing excellent agreement over the entire frequency range tested ({+-}100 Hz). With proper access to linearized data and continuous fluoroscopy, this method can be implemented in a clinical setting on both XRII and flat-panel detectors. It is shown that the temporal MTF of the CsI-based validation system is a function of exposure rate. The rising-edge response showed more lag than the falling edge, and the temporal MTF decreased with decreasing exposure rate. It is suggested that a small-signal approach, in which the range of exposure rates is restricted to a linear range by using a semitransparent moving edge, would be appropriate for measuring the DQE of these systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of diagnostic calorimeter data by the transfer function technique

This paper describes the analysis procedure applied to the thermal measurements on the rear side of a carbon fibre composite calorimeter with the purpose of reconstructing the energy flux due to an ion beam colliding on the front side. The method is based on the transfer function technique and allows a fast analysis by means of the fast Fourier transform algorithm. Its efficacy has been tested both on simulated and measured temperature profiles: in all cases, the energy flux features are well reproduced and beamlets are well resolved. Limits and restrictions of the method are also discussed, providing strategies to handle issues related to signal noise and digital processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗

Transfer Function Design for Scientific Discovery

As computation scales beyond terascale, the scientific problems under study through computing are increasingly pushing the boundaries of human knowledge about the physical world. It is more pivotal than ever to quickly and reliably extract new knowledge from these complex simulations of ultra scale. In this project, the PI expanded the traditional notion of transfer function, which maps physical quantities to visual cues via table look-ups, to include general temporal as well as multivariate patterns that can be described procedurally through specialty mini programming languages. Their efforts aimed at answering a perpetual question of fundamental importance. That is "what a visualization should show". Instead of waiting for application scientists to initiate the process, the team at University of Tennessee worked closely with scientists at ORNL in a proactive role to envision and design elegant, powerful, and reliable tools that a user can use to specify "what is interesting". Their new techniques include visualization operators that revolve around correlation and graph properties, relative patterns in statistical distribution, temporal regular expressions, concurrent attribute subspaces and traditional compound boolean range queries. The team also paid special attention to ensure that all visualization operators are inherently designed with great parallel scalability to handle tera-scale datasets in both homogeneous and heterogeneous environments. Success has been demonstrated with leading edge computational science areas include climate modeling, combustion and systems genetics.

97 MATHEMATICS AND COMPUTING↗

Evaluating the integrity of the reinforced concrete structure repaired by epoxy injection using simulated transfer function of impact-echo response

Cracks and honeycombs are often found inside reinforced concrete (RC) structure caused by excessive external force, or improper casting of concrete. The repairing method usually involves epoxy injection. The impact-echo method, which is a sensitive for detecting of the interior voids, may not be applicable to assess the integrity of the repaired member as both air and epoxy are less in acoustic impedances. In this study, the repaired RC structure was evaluated by the simulated transfer function of the IE displacement waveform where the R-wave displacement waveform is used as a base of a simulated force-time function. The effect of different thickness of the epoxy layer to the amplitude corresponding to the interface is studied by testing on specimen containing repaired naturally delaminated cracks with crack widths about 1 mm, 3 mm and 5 mm. The impact-echo responses were compared with the drilling cores at the test positions. The results showed the cracks were not fully filled with epoxy when the peak amplitude corresponding to the interface dropped less than 20%. The peak corresponding to the thicker epoxy layer tends to be larger in amplitude. A field study was also performed on a column damaged by earthquake before and after repairing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electromechanical Mode Shape Estimation Based on Transfer Function Identification Using PMU Measurement

Power system mode shapes are key indication of how dynamic components participate in low-frequency oscillations. Traditionally, mode shapes are calculated from a linearized dynamic model. For large-scale power systems, obtaining accu-rate dynamic models is very difficult. Therefore, measurement-based mode shape estimation methods have certain advantages, especially for the application of real-time small signal stability monitoring. In this paper, a measurement-based mode shape iden-tification method is proposed. The general relationship between transfer function (TF) and mode shape is derived. As an example, a least square (LS) method is implemented to estimate mode shape using an autoregressive exogenous (ARX) model. The per-formance of the proposed method is evaluated by Monte-Carlo studies using simulation data from a 17-machine model. The re-sults indicate the validity of the proposed method in estimating mode shapes with reasonably good accuracy

24 POWER TRANSMISSION AND DISTRIBUTION↗