Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Three-dimensional tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

ODIN: Confirmation and 3D Reconstruction of Six Massive Protoclusters at Cosmic Noon

Protoclusters represent sites of accelerated galaxy formation and extreme astrophysical activity characteristic of dense environments. Identifying massive protoclusters and mapping their spatial structures are therefore crucial for understanding how large-scale environment influences galaxy evolution. We combine wide-field Lyα imaging from the One-hundred-deg$^{2}$ DECam Imaging in Narrowbands survey with extensive Dark Energy Spectroscopic Instrument and ancillary spectroscopy across the extended COSMOS and XMM Large Scale Structure (LSS) fields (≈14 deg$^{2}$) to search for massive protoclusters. We confirm six systems at z ≈ 2.4 and ≈ 3.1, including three newly identified structures and three which overlap with previously known structures and/or systems detected using other tracers. We reconstruct their three-dimensional structures, estimate descendant halo masses, and for one structure at z ≈ 3.12, demonstrate that overlapping narrowband filters (NB497 and N501) provide accurate redshift tomography for emission-line galaxies. One protocluster at z ≈ 2.45 overlaps with one of the LATIS tomographic fields, enabling direct comparison between galaxy and H i overdensities traced by Lyα forest absorption. Another at z ≈ 3.12 hosts a massive quiescent galaxy (M$_{*}$ ≈ 1.2 × 10$^{11}$M$_{⊙}$), suggesting that overdense environments may play a role in accelerating galaxy assembly and quenching. Comparing Lyα emission properties across environments, we find that protocluster galaxies exhibit higher median line fluxes and a deficit of faint emitters relative to the field. The effect is strongest when combining 2D and 3D density information, indicating that galaxies in the densest protocluster cores are most affected by environmental processes. This effect is stronger at z ≈ 3.1 than at z ≈ 2.4, suggesting possible redshift evolution.

Ortiz, Ashley [Purdue U.] (ORCID:000900083184304X)↗

Machine Learning Enabled Advanced Electron Tomography for Resolving Chemical Inhomogeneity and Materials Dynamics in Lithium-Ion Battery Electrodes

The objective of this project is to develop machine learning-assisted electron microscopy, together with three-dimensional, cryogenic, and in-situ imaging techniques, for resolving chemical inhomogeneity and materials dynamics in lithium battery electrodes and interfaces. The project aims to expand the spatial, temporal, and dimensional resolution of transmission electron microscopy and to enable quantitative analysis of beam-sensitive battery materials.

25 ENERGY STORAGE↗

Quantitative computed tomography for spinal mineral assessment: current status

Quantitative CT (QCT) is an established method for the noninvasive assessment of bone mineral content in the vertebral spongiosum and other anatomic locations. The potential strengths of QCT relative to dual photon absorptiometry (DPA) are its capability for precise three-dimensional anatomic localization providing a direct density measurement and its capability for spatial separation of highly responsive cancellous bone from less responsive cortical bone. The extraction of this quantitative information from the CT image, however, requires sophisticated calibration and positioning techniques and careful technical monitoring.

Lumbar Vertebrae/radiography↗

Advances in Image-Domain Multi-Resolution and Super-Resolution Algorithms for Industrial X-Ray Computed Tomography: A Literature Survey and New Insights

Industrial X-ray Computed Tomography (XCT) is a nondestructive method for inspection and character ization of materials and parts. XCT captures images of a part from various angles, and these images are then used to construct Three-Dimensional (3D) representations of that part. This method enables assessing the quality of the parts, identifying defects and understanding their physical properties without damaging them.

36 MATERIALS SCIENCE↗

Physicochemical evolution of uranium nitride kernel microstructure with varying carbon distribution for advanced TRISO fuel forms

Uranium nitride (UN) has emerged as a fuel candidate for advanced nuclear reactor concepts due to its superior uranium density, thermal conductivity, and high melting temperature. However, the fabrication route for converting UO 2 to UN is complex and difficult to standardize. Although the chemistry of this conversion process is well-studied, more insight into the physicochemical dynamics of this conversion using advanced characterization techniques can help further our understanding of this material system. This work leveraged thermogravimetric analysis (TGA), X-ray diffraction (XRD), and nondestructive 3D X-ray computed tomography (XCT) to characterize dynamic microstructural changes in the UO 2 → UCO → UN fabrication pathway for two kernels with a varying carbon distribution in the starting composition. TGA and XRD were used to quantify changes in the mass, density, and chemical composition of the two kernels, while three-dimensional image processing and segmentation of XCT data were used to quantify the volume, surface area, and spatial distribution of features within each kernel for multiple steps along the fabrication pathway. The analysis indicates distinct differences between the two kernels that are correlated to downstream conversion efficiency. In conclusion, this work is among the first to perform 3D quantification of physicochemical evolution during UN conversion, providing quantitative correlation between processing, properties, and expected fuel performance.

Nuclear fuel↗

3D seismic imaging of a fracture damage zone controlling reservoir compartmentalization at the Raft River EGS using multi-azimuth walkaway VSP

Accurate imaging of steeply dipping fracture zones in crystalline enhanced geothermal systems (EGS) is critical for constraining permeability architecture and guiding stimulation design. However, such structures remain poorly resolved by conventional surface seismic methods. We present a fully three-dimensional (3D) elastic-waveform inversion-migration workflow applied to multi-azimuth walkaway vertical seismic profiling (VSP) data acquired in a deviated borehole at the Raft River EGS. The workflow integrates first-arrival traveltime tomography, multi-scale elastic waveform inversion (EWI), and elastic least-squares reverse-time migration (ELSRTM) to recover high-resolution compressional-and shear-wave velocity models and to image structural discontinuities in the crystalline basement. The results reveal a laterally continuous low-velocity anomaly, with shear-wave velocity reductions of 25-30%, consistent with fractureinduced mechanical weakening. Two steeply dipping discontinuities bound a 50-80 m wide fracture damage zone. Independent constraints from microseismic clustering and geochemical compartmentalization corroborate the geometry and structural significance of this feature. Synthetic modeling further confirms that structures of this scale are resolvable (~30 m). These findings indicate that the Narrows structure is a distributed fracture damage zone rather than a discrete fault plane. By resolving fracture-zone geometry at the tens-of-meters scale using a single borehole, this workflow provides a practical and transferable approach for improving structural characterization, reducing uncertainty in permeability architecture, and supporting reservoir modeling and stimulation design in fractured crystalline EGS reservoirs.

58 GEOSCIENCES↗

Positron emission reconstruction tomography for the assessment of regional myocardial metabolism by the administration of substrates labeled with cyclotron produced radionuclides

A positron emission transverse tomograph device was developed which provides transaxial sectional images of the distribution of positron-emitting radionuclides in the heart. The images provide a quantitative three-dimensional map of the distribution of activity unencumbered by the superimposition of activity originating from regions overlying and underlying the plane of interest. PETT is used primarily with the cyclotron-produced radionuclides oxygen-15, nitrogen-13 and carbon-11. Because of the participation of these atoms in metabolism, they can be used to label metabolic substrates and intermediary molecules incorporated in myocardial metabolism.

Ter-Pogossian, M. M.↗

Soft X-Ray Tomography Has Evolved into a Powerful Tool for Revealing Cell Structures

Over the past three decades, soft X-ray tomography (SXT) has rapidly evolved from a proof-of-concept microscopy method into a high-throughput quantitative imaging modality. This advancement enables researchers to address central questions in cell biology. Despite its relatively short developmental period compared to light and electron microscopy, SXT has emerged as a powerful imaging technology. It enables measuring chemical changes in cellular organelles, analyzing three-dimensional structures of whole cells and creating digital cellular models to study cell motility. We discuss the unique nature of SXT to visualize cells without fixation or labeling, enabling quantitative analyses of organelle chemical composition. We explore SXT microscopes available worldwide, SXT segmentation software, and the diverse cell types studied using this technique. We conclude with emerging directions in SXT imaging, including a brief discussion of recent discoveries that are highly influential and likely to become integral to cell biology textbooks.

Weinhardt, Venera↗

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING↗

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques↗

Computerized X-ray reconstruction tomography in stereometric analysis of cardiovascular dynamics

A computerized technique is proposed for obtaining cross-sectional images of the dynamic spatial distribution of X-ray attenuation covering the entire anatomic extent of the thorax and its contents in living dogs with a resolution of 1 mm and at time intervals of 1/60 sec. Use is made of an X-ray imaging chain which is a new high-performance video-fluoroscopic system, unique in its design and construction and called SSDSR for single source dynamic spatial reconstructor. This dynamic spatial reconstruction system is shown to provide the temporally and spatially coherent multiple cross sections required to obtain the full three-dimensional anatomic and simultaneous hemodynamic information necessary for detailed quantitative analyses of regional cardiopulmonary and vascular functions in both basic investigations of animals and clinical diagnostic applications to patients. Numerous photographs supplement the text.

Robb, R. A.↗

Reconstruction of a 3-dimensional transonic rotor flow field from holographic interferogram data

Holographic interferometry and computer-assisted tomography (CAT) are used to determine the transonic velocity field of a model rotor blade in hover. A pulsed ruby laser recorded 40 interferograms with a 2-ft-diam view field near the model rotor-blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting fringe-order functions, the data are transferred to a CAT code. The CAT code then calculates the perturbation velocity in seeral planes above the blade surface. The values from the holography-CAT method compare favorably with previously obtained numerical computations in most locations near the blade tip. The results demonstrate the technique's potential for three-dimensional transonic rotor flow studies.

Yu, Y. H.↗

A tomographic technique for aerodynamics at transonic speeds

Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.

Lee, G.↗

A tomographic technique for aerodynamics at transonic speeds

Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.

Lee, G.↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving the stability and performance of MagLIF implosions by applying dielectric coatings and increasing applied B z , fuel preheat, and load current

We report two magnetized liner inertial fusion (MagLIF) experiments that produced record thermonuclear D–D neutron yields of 2.11×10 13 and 2.33×10 13 . These yields are about a factor of two higher than previous MagLIF results. The experiments achieved ion temperatures of 3.0 and 3.3 keV and stagnation pressures of 1.6 and 1.3 Gbar. The inferred Lawson parameters were χ=0.2 and 0.1, which are the largest reported for MagLIF. The performance increase used a high-aspect-ratio beryllium liner with a dielectric coating and modest increases in preheat energy (∼2.2 kJ), peak current (18.5 MA), and axial magnetic field (15 T). Three-dimensional HYDRA simulations are consistent with the measured liner dynamics and fusion outputs. These results indicate a pathway to higher-yield MagLIF designs using coated, high-aspect-ratio liners and improved input parameters. Simulations further suggest that adding an ice fuel layer could increase yield by up to a factor of 2.5 by reducing liner convergence, instability feedthrough, and mix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unraveling Impurity-Dependent Morphological and Chemical Evolution of Ni–20Cr Alloy in Eutectic LiCl–KCl Molten Salt

Understanding the interfacial evolution of alloys in molten salt with different amounts of water (H 2 O) and oxygen (O 2 ) impurities is significant for applications in many fields, including concentrated solar power, molten salt reactors, and applications in pyrochemical reprocessing and electrorefining. Additionally, the impurity-driven corrosion mechanisms that lead to various morphological and chemical evolution characteristics at the interfaces of structural alloys and molten salts are not fully understood. In the present work, the three-dimensional (3D) morphological evolution of Ni-20Cr microwires in LiCl-KCl was studied at 500 °C under different moisture and oxygen conditions using in situ synchrotron transmission X-ray microscopy (TXM) and scanning transmission electron microscopy (STEM) techniques. No significant morphological changes were observed in Ni-20Cr microwires under vacuum conditions. However, the wires exhibited distinct morphological evolutions when exposed to molten salt containing H 2 O alone, as well as when both H 2 O and O 2 were present. Furthermore, Cr 2 O 3 precipitates were observed in the molten salt during corrosion with only H 2 O present, while Cr 6+ species were identified in the salt when O 2 was added. Further, these findings are crucial for understanding the corrosion mechanisms of molten salt with different amounts of H 2 O and O 2 contamination, providing insights for developing corrosion mitigation methods and improving the stability of containment alloys in molten salt applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated segmentation of soft X-ray tomography: Native cellular structure with submicron resolution at high-throughput for whole-cell quantitative imaging in yeast

Soft X-ray tomography (SXT) is an invaluable tool for quantitatively analyzing cellular structures at suboptical isotropic resolution. However, it has traditionally depended on manual segmentation, limiting its scalability for large datasets. Here, we leverage a deep learning-based autosegmentation pipeline to segment and label cellular structures in hundreds of cells across three Saccharomyces cerevisiae strains. This task-based pipeline uses manual iterative refinement to improve segmentation accuracy for key structures, including the cell body, nucleus, vacuole, and lipid droplets, enabling high-throughput and precise phenotypic analysis. Using this approach, we quantitatively compared the three-dimensional (3D) whole-cell morphometric characteristics of wild-type, VPH1-GFP, and vac14 strains, uncovering detailed strain-specific cell and organelle size and shape variations. We show the utility of SXT data for precise 3D curvature analysis of entire organelles and cells and detection of fine morphological features using surface meshes. Our approach facilitates comparative analyses with high spatial precision and statistical throughput, uncovering subtle morphological features at the single-cell and population level. This workflow significantly enhances our ability to characterize cell anatomy and supports scalable studies on the mesoscale, with applications in investigating cellular architecture, organelle biology, and genetic research across diverse biological contexts.

Chen, Jianhua [Lawrence Berkeley National Laborato↗