SLM Inconel 625 Thin Section Study
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A numerical digital computer program was developed to calculate the heat-transfer coefficients for both sides of a one-dimensional finite slab subject to the boundary conditions ascribed to the phase-change coating heat-transfer technique. In a typical tunnel test situation where a thin wing was exposed to heating on both sides, the data reduction procedures for a semi-infinite slab gave heat-transfer coefficients as much as 375 percent too high on the side with the lowest heating. The results from the one-dimensional finite-slab procedure are presented in the form of correction factors to the solution for a semi-infinite slab in terms of parameters normally used with the phase-change heat-transfer technique. These correlations are not restricted to slab thickness or thermophysical properties and are easily used to obtain accurate data on thin model sections.
The tendency toward economy of material and lightness of structure has long since led to the increased application of beams having large ratios of moment of area W to cross-sectional area F. This paper tries to provide an answer to how thin the beams can be.
The objective of this work was to characterize and model elevated temperature creep and fatigue behavior for thin sheet and foil forms of gamma-prime strengthened alloys in wrought form and as-processed folded and brazed constructions. This work was motivated by the demanding temperature and pressure service conditions of the GEN3 Concentrated Solar Power (CSP) and supercritical CO2 (sCO2) power cycle working fluid. More specifically, the possibility of leveraging the superior creep strength of gamma-prime alloys in folded-fin and brazed-plate heat exchanger constructions. Gamma-prime alloys represent a step-change in raw-material strength over solid-solution strengthened alloys. And the folded-fin and brazed-plate heat exchanger architecture is lightweight and leverages cost-effective material stock forms. The investigation contained two parallel paths. (1) The first is referred to as a fundamental investigation where Oak Ridge National Laboratory conducts uniaxial creep testing on thin sheet and foil in wrought form. This effort aimed to serve as a benchmark against a relatively sparse existing database and a baseline comparison for path number 2. (2) The second path is referred to as the practical investigation where Brayton Energy manufactures plate-fin heat exchangers and performs pressurized creep and fatigue testing. This effort aimed to de-risk heat exchanger manufacturing process for service under sCO2 CSP conditions. A total of 14 uniaxial creep tests were completed using Haynes 282 thin sheet and foil. A variety of heat treatments were specified to coincide with path number 2. Baseline metallography of test samples and creep strength performance are contained. Benchmarks relatively to existing thick-form Haynes 282 are made, as well as to other thin-form Nickel-based superalloys. Description of a wrought-form modeling approach for thin gamma-prime alloys is also discussed. A total of 11 pressurized creep and fatigue tests were completed successfully with Haynes 282 heat exchanger prototypes. Manufacturing processing details, testing details, testing results, and failure analysis are discussed. Additionally, creep modeling techniques to predict failure are discussed, and modeling to support technological-to-market. In conclusion, Haynes 282 foils were demonstrated to yield rupture two-to-three orders of magnitude higher than Haynes 230 foils under similar conditions. And the manufactured heat exchanger prototypes demonstrated strength similar to the wrought constituents. Both of which contribute to elevated performance potential or cost savings in practice. Discussion is included.
As additive manufacturing techniques develop, the effect of build part geometry on material properties is of increasing interest. Understanding the effects of thin wall geometries on the properties of the material produced via SLM is critical to effectively evaluating components for certification. This study investigates the tensile properties of additively manufactured Inconel 718 as a function of wall thickness and discusses potential impacts of the measuring technique on the test results.
A new high fluidity zinc high pressure die casting alloy, termed the HF alloy, was developed during laboratory trials and proven in industrial production. The HF alloy permits castings to be achieved with section thicknesses of 0.3 mm or less. Technology transfer activities were conducted to develop usage of the HF high fluidity alloy. These included production of a brochure and a one-hour webinar on the HF alloy. The brochure was then sent to 1,184 product designers in the Interzinc database. There was excellent reception to this mailing, and from this initial contact 5 technology transfer seminars were conducted for 81 participants from 30 companies across a wide range of business sectors. Many of the successful applications to date involve high quality surface finishes. Design and manufacturing assistance was given for development of selected applications.
Metal surface through and part through cracks, investigating dimensions and material properties effects on fracture stresses
Medical equipment for obtaining repetitive planoparallel sections of bone to study healing of bone structure under high gravity stress is described. Device consists of modified saw with diamond cutting edges. Construction of device and manner of use are explained.
Indigenous soil microorganisms were cultivated in their soil habitat with 50% moisture capacity at 30 C for two weeks. Changes in microorganism cells were studied by electron microscopy during incubation, with particular attention to the dormant cell growth and to the ability of cystlike cells to germinate and reencyst. The responses of various cell species to incubation conditions are described and illustrated by photomicrographs.
Explore the source record for details and available documents.
The Johnson Space Center (JSC) has the unique responsibility to curate NASA's extraterrestrial samples from past and future missions. Curation includes documentation, preservation, preparation, and distribution of samples for research, education, and public outreach. Between 1969 and 1972 six Apollo missions brought back 382 kilograms of lunar rocks, core samples, pebbles, sand and dust from the lunar surface. JSC also curates meteorites collected on US expeditions to Antarctica including rocks from Moon, Mars, and many asteroids including Vesta. Studies of rock and soil samples from the Moon and meteorites continue to yield useful information about the early history of the Moon, the Earth, and the inner solar system.
Explore the source record for details and available documents.
Thin airfoil theories of an ejector flapped wing section are reviewed. The global matching of the external airfoil flow with the ejector internal flow and the overall ejector flapped wing section aerodynamic performance are examined. Mathematical models of the external and internal flows are presented. The delineation of the suction flow coefficient characteristics are discussed. The idealized lift performance of an ejector flapped wing relative to a jet augmented flapped wing are compared.
Size distributions of chondrules, volcanic fire-fountain or impact glass spherules, or of immiscible globules in silicate melts (e.g., in basaltic mesostasis, agglutinitic glass, impact melt sheets) are imperfectly known because the spherical objects are usually so strongly embedded in the bulk samples that they are nearly impossible to separate. Hence, measurements are confined to two-dimensional sections, e.g. polished thin sections that are commonly examined under reflected light optical or backscattered electron microscopy. Three kinds of approaches exist in the geologic literature for estimating the mean real diameter of a population of 3D spheres from 2D observations: (1) a stereological approach with complicated calculations; (2) an empirical approach in which independent 3D size measurements of a population of spheres separated from their parent sample and their 2D cross sectional diameters in thin sections have produced an array of somewhat contested conversion equations; and (3) measuring pairs of 2D diameters of upper and lower surfaces of cross sections each sphere in thin sections using transmitted light microscopy. We describe an entirely probabilistic approach and propose a simple factor of 4/x (approximately equal to 1.27) to convert the 2D mean size to 3D mean size.
The effects of an aluminide coating, Codep B-1, and of section thickness were investigated on two cast nickel base superalloys, Rene 80 and Rene 120. Cast section thicknesses ranged from 0.038 cm to 0.15 cm. Simulated engine exposures for 1000 hours at 899C or 982C in a jet fuel burner rig with cyclic air cooling were studied, as were the effects of surface machining before coating and re-machining and re-coating after exposures. The properties evaluated included tensile at room temperature., 871C and 982C, stress rupture at 760C, 871C, 982C and 1093C, high cycle mechanical fatigue at room temperature., and thermal fatigue with a 1093C peak temperature. Thin sections had tensile strengths similar to standard size bars up to 871C and lower strengths at 982C and above, with equivalent elongation, and stress rupture life was lower for thin sections at all test conditions. The aluminide coating lowered tensile and rupture strengths up to 871C, with greater effects on thinner specimens. Elevated temperature exposure lowered tensile and rupture strengths of thinner specimens at the lower test temperatures. Surface machining had little effect on properties, but re-machining after exposure reduced thickness and increased metallurgical changes enough to lower properties at most test conditions.
The ANSMET program began in 1976, and since that time more than 18,000 meteorites have been processed in the Meteorite Processing Lab at Johnson Space Center in Houston, TX[1]. The meteorites are collected and returned to JSC on a freezer truck and remain frozen until they are initially processed. Initial Processing of Meteorites: Initial processing involves drying the meteorites in a nitrogen glove box for 24 to 48 hours, photographing, measuring, weighing and writing a description of the interior and exterior. The meteorite is broken and a representative sample is sent to the Smithsonian Institution for classification. Newsletter & Requests: Once initial processing has been complete and the meteorites have been classified, the information is published in the Antarctic Meteorite Newsletter[2,3]. The newsletter is published twice yearly and is sent electronically to researchers around the world and is also available on line. Researchers are asked to fill out a request form and submit it to the Meteorite Working Group secretary. All sample requests will be reviewed by either the meteorite curator or the Meteorite Working Group de-pending on the type of meteorite and the research being conducted. Processing for Sample Requests: In the meteorite processing lab, meteorite samples are prepared several different ways. Most samples are prepared as chips obtained by use of stainless steel chisels in a chipping bowl or rock splitter. In special situations where a researcher needs a slab the meteorite samples can be bandsawed in a dry nitrogen glove box with a diamond blade, no liquids are ever introduced into the cabinet. The last type of sample preparation is thin/thick sections. The meteorite thin section lab at JSC can prepare standard 30-micron thin sections, thick sections of variable thickness (100 to 200 microns), or demountable sections using superglue. Information for researchers: It is important that re-searchers fill the sample request form completely, in order to make sure the meteorite is processed correctly[4]. Re-searchers should list any special requirements on the form, i.e. packaging of samples (poly vs. stainless), thick sections and thickness needed, superglue needed, interior chips, exterior chips, fusion crust, contamination issues, all concerns should be listed so processing can be done accurately and any concerns the researcher has can be addressed be-fore the meteorites are broken.
Currently, absolute quantitation aspects of droplet-based surface sampling for thin tissue analysis using a fully automated autosampler/HPLC-ESI-MS/MS system are not fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from thin tissue sections. Methods: Adjacent thin tissue sections of propranolol dosed mouse brain (10- μm-thick), kidney (10- μm-thick) and liver (8-, 10-, 16- and 24- μm-thick) were obtained. Absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and tandem mass spectrometric analysis. These values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. Results: Extraction efficiency of propranolol using 10- μm-thick brain, kidney and liver thin tissues using droplet-based surface sampling varied between ~45-63%. Extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Randomly selecting half of the samples as standards, precision and accuracy of propranolol concentrations obtained for the other half of samples as quality control metrics were determined. Resulting precision ( ±15%) and accuracy ( ±3%) values, respectively, were within acceptable limits. In conclusion, comparative quantitation of adjacent mouse thin tissue sections of different organs and of various thicknesses by droplet-based surface sampling and by bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided the required quantitation accuracy and precision for assay validations. Furthermore, this means that once the extraction efficiency was calibrated for a given tissue type and drug, the droplet-based approach provides a non-labor intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type.