Optimization of the FRIB beam dump: a hybrid genetic algorithm and reinforcement learning approach

The operational envelope of high-power-density systems, such as particle accelerators and advanced nuclear energy systems, is critically constrained by the need to manage extreme thermal loads. To address this, we present a novel hybrid optimization framework combining a genetic algorithm (GA) with a soft actor-critic (SAC) deep reinforcement learning agent. This framework was applied to a practical high-heat-flux problem: redesigning the beam dump at the Facility for Rare Isotope Beams (FRIB) for a power upgrade from 20 kW to 50 kW. The resulting design, validated by three-dimensional conjugate heat transfer simulations, suppresses hazardous hot spots and yields a markedly more uniform temperature distribution. This provides a robust operating margin, increasing the average power-handling capability by 72% relative to the current design, demonstrating the framework’s potential to solve complex thermal management challenges in both accelerator technology and advanced nuclear systems.

Accelerator↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

Software For Advanced Large-scale Analysis Of Magnetic Confinement For Numerical Design, Engineering & Research (salamander)

As magnetic confinement fusion energy gains traction internationally to enable abundant energy production, designing components for fusion systems is a pressing challenge. During the planned lifetime of a fusion device, components evolve in extreme environments and must withstand large, repeated thermal loads and bombardment by 14 MeV neutrons, plasma ions, and neutral particles (deuterium, tritium, and helium), corrosive conditions, etc. All these physical processes take place simultaneously, interact in intricate ways, and impose important constraints that can affect performance. Experimental data is rare and costly to obtain, making design particularly challenging. Predictive computational frameworks must be an integral part of an accelerated and cost-effective design process by modeling fusion system performance in simulated environments. To better understand component degradation and operational impacts on their performance, the Software for Advanced Large-scale Analysis of MAgnetic confinement for Numerical Design, Engineering & Research (SALAMANDER) is designed as an open-source, fully integrated, multiphysics, multiscale, NQA-1 compliant framework facilitating 3D, high-fidelity fusion system modeling. To that end, SALAMANDER is a MOOSE-based framework, and therefore leverages MOOSE upstream libraries such as PETSc and libMesh to deliver sophisticated finite element, finite volume, and nonlinear solver technology for fusion energy simulations. SALAMANDER couples MOOSE physics module capabilities—such as thermal hydraulics, heat conduction, Navier-Stokes, and thermomechanics—with tritium transport via TMAP8, neutronics via Cardinal, and nascent particle-in-cell capabilities. Direct simulation Monte Carlo methods will be used to address neutral transport near the walls. By coupling all these physics in an integrated application, SALAMANDER will enable high-fidelity modeling of irradiation levels and plasma exposure conditions of plasma facing components and their impact on heat and tritium distributions, as well as the resulting mechanical constraints experienced by the plasma facing components and performance of blanket systems. Furthermore, SALAMANDER will be particularly suited for engineering studies thanks to the stochastic tool module readily available in MOOSE, allowing for extended uncertainty quantification and risk analysis studies. It is also able to use computer-aided design (CAD) meshes to model complex geometries, which is indispensable for fusion systems. SALAMANDER therefore supports design, safety, engineering, and research projects for magnetic confinement fusion systems

Simon, Pierre-Clement [Idaho National Laboratory (↗

DECOVALEX-2023: Task C Final Report

The Full-scale Emplacement (FE) heater experiment at the Mont Terri Underground Rock Laboratory (URL) was designed and conducted by Nagra to replicate an emplacement tunnel of Nagra’s reference repository design at 1:1 scale. Alongside testing the technical feasibility of constructing disposal tunnels, emplacing waste containers in the tunnels and then backfilling them, the main goals of the FE experiment are (1) to obtain a better understanding of the coupled effects of induced thermo-hydro-mechanical (THM) processes that may occur and (2) to validate existing coupled THM models (Müller et al., 2017). A key aspect of ensuring safety for repositories located in low-permeability rock involves minimizing any damage to the rock itself, thereby preserving its integrity and promoting a stable environment Amongst a number of processes that could damage the rock is the increase in pore pressure due to thermal loading caused by heat emitted from the waste. To reduce the potential damage of the rock, it is important to analyse the evolution of heat over time due to the heat load of the containers and assess possible consequences by coupled THM models. The aim of Task C of DECOVALEX-2023 was to build 3D numerical models of the FE experiment, focussing in particular on the heating induced pore pressure change in the Opalinus Clay. Data from a large number of sensors were available from the FE experiment for model comparison. These sensors measured temperature and relative humidity in the bentonite around the heaters, and temperature, pressure and displacement/strain in the surrounding Opalinus clay. Data were available from the start of excavation (April 2012) up to August 2020 for most sensors (more than 5 years from the start of heating in December 2014). To fulfil the overall aim of the task, the work was broken down into a number of steps, starting with simpler models to build confidence in each team’s approach and then moving to more complex models that better represent the FE experiment. Step 0 consisted of 2D benchmark models, gradually increasing the number of processes that are represented from thermal (T) only models in Step 0a, to coupled thermal hydraulic (TH) models in Step 0b with a representation of changing porosity, to coupled thermo-hydro-mechanical (THM) models in Step 0c, where porosity changes are calculated by the mechanical model. A detailed specification of processes, parameters, initial and boundary conditions was provided for this step, with the ambition that all teams would work towards close agreement in their model results, thus building confidence in the model implementations. vi It was not straightforward to achieve agreement between the teams, so additional steps (Step 0b2, 0b3, 0c2, 0c3) were added along with derivation of some analytical solutions against which the models could be compared. The reasons for the differences between teams were investigated and found to be caused primarily by different conceptual model assumptions (including temperature dependence of the thermal expansion of water), different model formulations (including porosity evolution) and differences in modelled domain sizes, boundary conditions and grid discretisation. This demonstrates that comparisons between multiple modelling teams and/or comparison with analytical results and experimental data are highly beneficial in providing an indication of uncertainty in model predictions. At the conclusion of Step 0, almost all teams had achieved a close agreement in model results and those that had not achieved an agreement knew the reason for this. Step 1 moved from 2D models to 3D models of the FE experiment without adding technical features like shotcrete or EDZ, and only considering the heating phase. Initially the 3D model was tightly specified to continue to build confidence in the model implementations (Step 1a). The results of Step 1a were compared to the data from the FE-experiment without the teams seeing the data. The teams were then provided with a sub-set of the data from the FE-experiment and invited to consider how best to use the large dataset for model comparison (Step 1b). Teams were then asked to use the data provided to calibrate their models, only changing material property values rather than adding features or processes to their models (Step 1c). In Step 1, teams were asked to only model the heating phase of the experiment, so pressure in the Opalinus Clay was reported as change in pressure since the initial conditions were specified rather than modelled. The change from 2D to 3D models was accompanied by an increase in the dispersion of results between the teams. Some of this was resolved during the task, but some remained and is potentially due to model discretisation. Calibration of parameters was useful in improving the fit of the models to the data but the remaining differences indicated that the models were missing features or processes. In Step 2, the teams were asked to update their models with additional features and processes as well as calibrating parameters to try and improve the fit of the models to the data. Teams were encouraged to represent ventilation of the open FE tunnel prior to backfilling with heaters and bentonite and in Step 2, the absolute pressure in the Opalinus Clay was compared between the teams. Teams took different approaches, but there was consideration of adding shotcrete and an EDZ into the model, representing stress change during excavation and different approaches to modelling ventilation of the FE tunnel. Overall, the documented results showed a very good agreement for temperature. The results for porewater pressure evolution showed a significant improvement for most teams compared to Step 1c with a good agreement to the measurements for several teams whereas some teams overpredicted the pressure increase and others overpredicted the drainage effect especially for the sensors close to the heater. Step 3 was an opportunity for teams to use the models developed in Step 1 and Step 2 to make predictions about the temperature and pressure changes that will be expected at the FE experiment over the next few years in light of the planned changes in thermal output of the heaters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Thermophysical properties of the Ghareb formation relevant for nuclear waste disposal

The Ghareb formation, a shallowly buried porous chalk in Israel, is currently a candidate for nuclear waste disposal. The potential repository is somewhat unique for its host rock and emplacement in shallow (500 m) engineered large diameter boreholes. Herein, the thermal properties of the Ghareb are determined to support design and performance assessment; the relevant properties measured are thermal conductivity, specific heat capacity, thermal diffusivity, and thermal expansion coefficient along with their relationship with varying temperature. For the temperature range of 40 to 275 °C, the thermal conductivity ranges from 0.30 to 1.10 W/m·K, the thermal diffusivity ranges from 0.20 to 0.72 mm 2 /s, and volumetric heat capacity ranges from 0.86 to 2.00 MJ/m 3 ·K. Thermal strain measurements were used to estimate the linear thermal expansion coefficient to be 6·10 –4 –9·10 –2 °C -1 from 40 to 300 °C. These measured properties were used in a thermomechanical model to estimate near-field stresses an hour and 10 years after waste emplacement; the borehole was found to be stable. Thermal loading after 10 years was predicted to elevate local pore pressures by 1–1.5 MPa. The laboratory measurements coupled with analyses are the first attempts at performance assessment characterization for this first of its kind potential repository setting with this chosen host rock.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

Porous Flow Modeling of Axial Gas Redistribution in Fragmented LWR Fuel Rods using MOOSE

Understanding how gas axially redistributes within fragmented fuel pellets is crucial for predicting the behavior of Light Water Reactor (LWR) fuel rods, particularly during transient and accidental scenarios. The time scale of this phenomenon plays a fundamental role in determining the progression and hazard of a Loss Of Coolant Accident (LOCA), especially when high burn-up fuel in a severe state of fragmentation is involved. Here, this study presents a Computational Fluid Dynamics (CFD) model developed within the Multiphysics Object-Oriented Simulation Environment (MOOSE) to predict the time-scale of plenum depressurization in Light-Water Reactor (LWR) fuel rods driven by axial gas transport through fragmented pellets. The model examines the effects of incorporating non-linearities in the friction term by comparing the results with experimental data. The experiment employed surrogate fuel rods containing pellets subjected to mechanical and/or thermal loadings to simulate various severity of cracking, and aimed at studying the influence of fuel conditions on axial gas redistribution. The results of this analysis indicate that under certain flow regime conditions - determined by the value of an equivalent Reynolds number - accounting for the non-linear friction term in Navier-Stokes equations guarantees better predictions for the time-scale of plenum depressurization. Also, the model enabled the simulation of the pressure decay by assigning distinct permeability values to each pellet instead of a single uniform value. Multiple simulations were run across all possible pellet position combinations, having each pellet assigned with values of permeability extracted from the experimental data. This allows to quantify the impact of the considering various non-uniform distributions of permeability on the dynamics of axial gas redistribution. The present work findings enhance the understanding of axial gas transport, and provide valuable insights for the integration of a model for predicting the axial gas redistribution during a LOCA scenario into the BISON fuel performance code.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling Framework to Predict Melting Dynamics at Microstructural Defects in TNT-HMX High Explosive Composites

Many high explosive (HE) formulations are composite materials whose microstructure is understood to impact functional characteristics. Interfaces are known to mediate the formation of hot spots that control their safety and initiation. Here, to study such processes at molecular scales, we developed all-atom force fields (FFs) for Octol, a prototypical HE formulation comprised of TNT (2,4,6-trinitrotoluene) and HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine). We extended a FF for TNT and recasted it in a form that can be readily combined with a well-established FF for HMX. The resulting FF was extensively validated against experimental results and density functional theory calculations. We applied the new combined TNT-HMX FF to predict and rank surface and interface energies, which indicate that there is an energetic driver for coarsening of microstructural grains in TNT-HMX composites. Finally, we assess the impact of several microstructural environments on the dynamic melting of TNT crystal under ultrafast thermal loading. We find that both free surfaces and planar material interfaces are effective nucleation points for TNT melting. However, MD simulations show that TNT crystal is prone to superheating by at least 50 K on subnanosecond time scales and that the degree of superheating is inversely correlated with surface and interface energy. The modeling framework presented here will enable future studies on hot spot formation processes in accident scenarios that are governed by strong coupling between microstructural interfaces, material mechanics, momentum and energy transport, phase transitions, and chemistry.

36 MATERIALS SCIENCE↗

Discovering tungsten-based composites as plasma facing materials for future high-duty cycle nuclear fusion reactors

Abstract Despite of excellent thermal properties and high sputtering resistance, pure tungsten cannot fully satisfy the requirements for plasma facing materials in future high-duty cycle nuclear fusion reactions due to the coupled extreme environments, including the high thermal loads, plasma exposure, and radiation damage. Here, we demonstrated that tungsten-based composite materials fabricated using spark-plasma sintering (SPS) present promising solutions to these challenges. Through the examination of two model systems, i.e., tungsten-zirconium composite for producing porous tungsten near the surface and dispersoid-strengthened tungsten, we discussed both the strengths and limitations of the SPS-fabricated materials. Our findings point towards the need for future studies aimed at optimizing the SPS process to achieve desired microstructures and effective control of oxygen impurities in the tungsten-based composite materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Structured light approaches in laser-based plasma diagnostics

There is a growing demand for plasma diagnostics suitable for industrial plasma reactors employed in semiconductor nanofabrication, especially relevant to microelectronics and quantum information systems. Such reactors typically have limited optical access and pose considerable diagnostic challenges, including intense background emission, significant thermal loads, and contamination of optical viewports. In this study, we outline research into structured light techniques (laser beams with tailored spatial, temporal, or phase characteristics) that effectively overcome these issues using laser-induced fluorescence (LIF) as an example. The focus of presented diagnostics is on ion kinetics analysis within an industrial plasma source, although this approach is broadly applicable to other plasma systems and diagnostic contexts. We present a confocal LIF implementation using an axicon-generated Bessel annular beam, achieving spatial resolutions of approximately 5 mm at a focal distance of 300 mm, with potential improvements to about 1 mm. This approach matches conventional orthogonal LIF performance but requires only one optical port. Wavelength-modulation LIF employs nonlinear laser wavelength tuning to measure spectral line derivatives, suppressing background emission and enhancing details of spectral line shape. Additionally, we present new results on applying vortex beams (laser beams carrying orbital angular momentum, OAM) for LIF measurements in an industrial plasma device. These measurements enable simultaneous axial and tangential velocity determination using a single laser beam and have been tested with xenon ion transition. Initial quantification of results was performed. Together, these structured-light approaches provide robust, background-resilient, multi-dimensional diagnostics for complex plasma environments.

Romadanov, Ivan [Princeton Plasma Physics Laborato↗

Technoeconomic Design Optimization for Fast Reactors. Part I: Workflow Development and Case Study for Small LFR District Energy Application

The nuclear industry is developing small reactor designs that can target a variety of deployment locations and energy products. Smaller nuclear designs have traditionally struggled to handle the steep trade-offs between size and cost that have historically incentivized large reactors. This motivates computational optimization of small reactors to minimize costs and quantify the trade-off between size and cost. In this paper, the cost/size trade-off for a small fast reactor is derived using a multi-objective genetic algorithm optimization, with steady-state, transient, and cost analysis of the fast reactor being performed. Specifically, the method is demonstrated on a small 10- to 120-MW(thermal) U-Pu-Zr–fueled lead-cooled fast reactor with a 10-year core life for district energy applications, which can have a thermal load compatible with this range. The results reinforced that fast reactor cores at the lower end of this power range suffer cost penalties due to critical mass considerations. It was found that high power density cores with strong reactivity swings and many control rods were favored over designing to minimize reactivity swing. Furthermore, this contrasts with some traditional configurations designed using engineering judgment and demonstrates that optimizers can find nontraditional but realistic solutions, along with demonstrating the value of incorporating cost functions into whole-reactor design optimization.

Fast reactor↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

TEC (ThermoElastoCreep) [SWR-25-167]

This repository provides a Python script to simulate the thermomechanical behavior of Concentrating Solar Power (CSP) receivers under periodic thermal loading. The simulation couples elastic and creep strains to predict stress relaxation, fatigue, and rupture life of the receiver structure. The work was done under the project Light Trapping Planar Cavity Receiver (LTPCR) funded by U.S. Department of Energy. All other relevant work and publications from LTPCR project can be found at https://github.com/NatLabRockies/LTPCR-Public

He, Xin [National Laboratory of the Rockies (NLR),↗

Waste Tank Structural Assessment

This chapter describes the single and double shell tanks at Hanford, analysis of record and static and thermal loads analysis.

Grant, Christopher L.↗

Next Generation Heat Transfer Fluids for Two-Phase Immersion Cooling of Data Centers

The purpose of this study is to evaluate the performance of next generation dielectric fluids in a Two-Phase Immersion Cooling (2PIC) system, which was designed for use in data centers. Hence, this report contains the performance evaluations of a new developmental dielectric fluid, Opteon™ 2P50, in a commercially available small-scale 2PIC system under typical and off-design range of operating conditions. Accordingly, ambient temperature and thermal loads were varied to simulate different ambient conditions. Additionally, this research report describes the development of a semi-empirical lumped model to predict the energy efficiency of the 2PIC system using Opteon™ 2P50 across a wide range of conditions. The model aims to offer a comprehensive understanding of the system’s efficiency and potential improvements. The outcomes of this study are expected to contribute to the adoption of sustainable 2PIC cooling technologies in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗