Iso-cost-performance of thermal energy storage

As thermal energy storage (TES) systems gain increasing recognition as next-generation energy storage solutions, evaluating their techno-economic performance is crucial. This perspective analyzes the cost-performance of latent heat-based TES systems and introduces the concept of iso-cost-performance—maintaining a constant cost per unit energy ($\$$/kWh) despite material degradation. Using an empirical degradation model, we show that after 1200 thermal cycles, the thermal conductivity and volumetric energy density of a paraffin-based phase change material (PCM) decreased by 36.0% and 26.1%, respectively, resulting in a 31.2% reduction in the figure of merit (FOM) and, consequently, the system cost-performance. However, by introducing thermally conductive additives to enhance effective thermal conductivity, the TES system can recover its initial FOM, achieving iso-cost-performance operation. This framework quantitatively demonstrates how degradation-mitigation strategies—such as improving thermal conductivity—can offset material degradations and maintain long-term cost-effectiveness. Beyond PCM-based TES, the proposed FOM-based approach provides a generalized pathway for cost-performance optimization across various TES technologies.

25 ENERGY STORAGE↗

Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics↗

High-heat transfer lithium-ion batteries: A new era in battery thermal management

Despite advances in lithium-ion battery technology, critical challenges remain that must be addressed to accelerate electric vehicle (EV) adoption and global energy transformation. Significantly improved battery thermal management (BTM) is key to overcoming these challenges. BTM approaches focus on increasing heat transfer coefficients via air, liquid, or refrigerant cooling, but less attention is given to reducing the battery's thermal resistance, a major bottleneck for heat transfer. This work introduces a novel approach to reduce battery thermal resistance by integrating in-plane heat transfer with optimized cell geometry, minimized thermal resistances, and reduced interfacial resistances, representing a departure from previous methods. The standard prismatic can cell incorporating this technology is referred to as the high heat transfer (HHT) battery. An equivalent resistance battery thermal model is developed for speed and accuracy, validated against experimental data in the literature, demonstrating strong correlation and ensuring reliable predictions for real-world performance. Thermal performance metrics of the conventional and HHT batteries are compared using a parametric study with air, liquid, and refrigerant boundary conditions across a range of aspect ratios. The HHT battery shows a heat removal rate up to 20 times higher than a conventional battery. These findings suggest that HHT technology could be transformative for EV battery performance, enabling fast charging, mitigating thermal runaway, extending battery life, reducing cold-weather power loss, increasing reliability, lowering costs, and enabling higher energy density, all critical for EV adoption and energy transformation. Future work will focus on prototyping and real-world testing to refine these findings for commercial-scale applications.

25 ENERGY STORAGE↗

The role of moisture in MgCl 2 salt: A multiscale approach to TES performance

This study presents a comprehensive multiscale analysis to evaluate the influence of moisture on the thermal performance of thermal energy storage systems using magnesium chloride (MgCl 2 ) as the phase-changing material. The system uses graphite foam with 90% relative density to enhance thermal conductivity. The analysis includes thermal conductivity calculations and specific heat capacity for different hydrate phases of MgCl 2 : Anhydrous, Mono, Di, Tetra, and Hexa. These properties were evaluated for the first time using the phonon density of states from Density Functional Theory simulations. Results showed that thermal conductivity decreased, while specific heat capacity increased by a factor of two as the phase changed from anhydrous to hexahydrate. Meso-scale models were created to account for the anisotropy of graphite foam and property variations of the MgCl 2 hydrate phases. Asymptotic Expansion homogenization simulations determined the anisotropic thermal conductivity for all phases. This unique methodology improved simulation accuracy, which matched experimental data for anhydrous MgCl 2 . A parametric study examined various operating conditions and their effect on TES performance. It revealed that higher charging temperatures did not enhance exergy efficiency, but increased discharge mass flow rates improved it due to better heat transfer. Thermal performance evaluated by the exergy efficiency remained consistent across hydrate systems under the tested conditions. Furthermore, the study suggests that this uniformity is linked to missing key data, particularly latent heat and melting point for different hydrates. Overall, it highlights the importance of multiscale effects and accurate material properties in designing and optimizing TES systems.

Molten salt degradation↗

Prototype Development, Testing, and Modeling for a Solar Light-Trapping Planar-Cavity Particle Receiver (LTPCR)

Many applications for concentrating solar thermal power (CSP) technologies of high efficiency power cycles or thermochemical processes require higher operating temperatures and alternative heat transfer media. Inert solid particles for next-generation CSP and reactive gas and/or solid media for solar thermochemical processes are common options; however, these have significantly lower heat transfer capabilities than thermal oil, molten salt, or molten metal media. Conventional solar receivers operating temperatures >700 degrees Celsius face challenges including thermal performance and thermal-mechanical issues. To overcome these limitations, we have developed a novel light-trapping, planar-cavity receiver (LTPCR) that can heat solid-phase media within an enclosed receiver while maintaining a high aperture solar flux concentration for high efficiency. This paper presents progress on design, fabrication, and testing of a 100 kWt prototype receiver to demonstrate the LTPCR operability and its commercial feasibility.

14 SOLAR ENERGY↗

Prototype Development, Testing, and Modeling for a Solar Light-Trapping Planar-Cavity Particle Receiver

Many applications for concentrating solar thermal power (CSP) technologies of high efficiency power cycles or thermochemical processes require higher operating temperatures and alternative heat transfer media. Inert solid particles for next-generation CSP and reactive gas and/or solid media for solar thermochemical processes are common options; however, these have significantly lower heat transfer capabilities than thermal oil, molten salt, or molten metal media. Conventional solar receivers operating temperatures >700 degrees Celsius face challenges including thermal performance and thermal-mechanical issues. To overcome these limitations, we have developed a novel light-trapping, planar-cavity receiver (LTPCR) that can heat solid-phase media within an enclosed receiver while maintaining a high aperture solar flux concentration for high efficiency. This paper presents progress on design, fabrication, and testing of a 100 kWt prototype receiver to demonstrate the LTPCR operability and its commercial feasibility.

14 SOLAR ENERGY↗

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE↗

Development of a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on high efficiency power cycles and chemical reactions that require high operating temperatures. An increase in receiver operating temperatures relative to current commercial CSP technology is necessary to support more efficient, high temperature power cycles or thermochemical processes. Solar receivers operating with heat transfer media temperatures >700 degrees C face various challenges including thermal performance, scalability, thermal-mechanical issues, and receiver service life. In addition, heat transfer media selection for high-temperature processes has been moving towards inert solid particles in Gen3 CSP, and reactive solid media and/or gases in solar thermochemical processes. To overcome the shortcomings and limitations of conventional designs for molten salt or particle receivers and receiver reactors, we introduce a unique light-trapping, planar cavity receiver (LTPCR) configuration and will present the current development progresses to demonstrate receiver feasibility through modeling, testing, and prototype demonstration.

ENGINEERING,SOLAR ENERGY↗

HOLISTIC ENERGY EFFICIENCY ANALYSIS OF ELECTRIFIED OFF-HIGHWAY MATERIAL HANDLER: FROM DRIVE CYCLE CHARACTERIZATION TO POWERTRAIN, HYDRAULIC, AND THERMAL SYSTEM PERFORMANCE

Three complexities surrounding the operation and testing of hybrid electric, heavy-duty nonroad machines have been addressed experimentally and using 1D simulation. Their resolutions have been intertwined with the development of a prototype machine that was proven to reduce fuel consumption in excess of 20%. A real-world drive cycle that leveraged hydraulic cylinder position was developed and utilized to ensure accurate reproduction of hydraulic work between the baseline and hybrid machines, while simultaneously maintaining less than 5% RMS error in position for main load handling functions. The newly developed, machine-specific drive cycle also contributed towards making equivalent comparisons in energy consumption between machine types through composite performance metrics that were extrapolated over a typical shift duration. Lastly, this work addressed thermal management energy consumption, a topic of increasing popularity when discussing electrified vehicles, by proposing a 1.4% energy savings through special mechanization and control of cooling system components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, Fabrication and On-Sun Performance Evaluation of SiC Receiver Feature Specimens for CST Applications Using Additively Manufactured SiC Materials

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Successful development of CST systems to generate heat for industrial applications requires significant increase in temperature capability and techno-economically viability of the receiver systems. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Aerospace Research in collaboration with Heliogen Holdings Inc and Sandia National Lab, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to demonstrate SiC receiver with air exit temperatures up to 1100 oC and high thermal efficiencies. We report design, fabrication and on-sun test results of SiC components of a prototype 50kW (thermal) HOTSSTAR module. The receiver module architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around a SiC center absorber. The SiC components are fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the reliability and to minimize the risk of cracking damage of SiC test articles in thermal gradient and thermal shock environment of the application, the components were laminated with GE’s MI SiC-SiC CMC. Following extensive design and lab test analyses, selected SiC component designs are tested at Heliogen Lancaster Solar field under highly concentrated solar fluxes around 2000 suns to assess the thermal performance characteristics under realistic field conditions. We report on the test results and compare the thermal performances of different HOTSSTAR SiC absorbers. Finally, we discuss fabrication and initial assembly of a 50kW prototype test module in preparation of on-sun field tests to assess the performance of our final design.

CST, CSP, high temperature, air receiver, SiC, add↗

Thermal Optimization and Experimental Demonstration of a Silicon Carbide, Half-Bridge Power Module

This paper describes modeling and experimental work to design and demonstrate a silicon carbide (SiC), single-side-cooled power module. Two SiC metal-oxide-semiconductor field-effect transistors (MOSFET) were used for each switch position and packaged on a metalized ceramic substrate. Thermal modeling was first conducted to optimize the module packaging to minimize junction-to-fluid thermal resistance and device temperature variations. This procedure identified the optimal device placement and baseplate thickness to maximize thermal performance. A heat exchanger - incorporating impinging jets of water-ethylene glycol - was designed to cool the module's baseplate to minimize thermal resistance and pumping power. The heat exchanger used relatively low fluid velocities (<1.5 m/s) to minimize erosion-corrosion effects and relatively large fluid channel sizes (>=1 mm) to prevent clogging. The power module concept was fabricated, and experiments were conducted to measure its thermal performance. Direct current was used to power the module devices, and junction temperatures were measured via device temperature-sensitive parameters. The experimental results were found to be in good agreement with model predictions (within 2%) and yielded junction-to-fluid thermal resistance values as low as about 15 mm2 K/W at relatively low pumping power values. The results demonstrate the improved performance associated with jet impingement cooling and represent an improvement over existing channel-flow-type cold plates, which can enable improvements to power density and reliability.

36 MATERIALS SCIENCE↗

Thermal Management for Planar Package Power Electronics (CRADA Final Report)

The National Renewable Energy Laboratory (NREL) and John Deere Electronic Solutions (JDES) collaborated to develop and evaluate computer models and simulations related to the thermal performance of semiconductor device packaging for an inverter of an off-road vehicle ("Semiconductor Packaging"). The objective of the research was for NREL and JDES to develop a two or three-dimensional computer-aided design model of the Semiconductor Packaging ("Computer Model") for thermal performance evaluation in a simulation. The project developed computer models of a Semiconductor Package of silicon-carbide semiconductor devices with appropriate thermal dissipation via one or more of the following thermal features: a double-sided planar cooling configuration, an air-cooled configuration, a liquid-cooled configuration for off-road inverter applications in a relevant simulated operating environment. It is noted that surface area and prototype product embodiment consisting of air-cooled and liquid-cooled configurations may and may not be in direct contact with power semiconductor chips. The idea was to explore and develop packaging and thermal management technology for power semiconductors that was most effective in the performance yet had least burden in overall product cost for a given application.

33 ADVANCED PROPULSION SYSTEMS↗

Design, fabrication, simulation, and testing of additively manufactured lattice-based copper heat sinks

Here, this study investigates the potential advantages of lattice structure-based bound metal material extrusion (MEX) 3D printing for fabricating high-performance copper heat sinks. Copper powder-filled polymer filaments, with a copper content of > 90 wt.%, were developed specifically for the bound metal MEX 3D printing process. Three types of structures—planar, strut, and surface lattices—were 3D printed to facilitate efficient heat transfer pathways within the heat sinks. Subsequent post-processing steps, including polymer removal and sintering, were performed to achieve dense copper parts. Hot isostatic pressing was further employed to enhance the sintered density from 93 to 98%. Finite element analysis (FEA) simulations were conducted to assess the heat transfer efficiency of the designs, and heat transfer experiments were performed using a custom setup to validate the simulation results. Additionally, this research explores the use of extended hold times during pre-sintering and a reduced atmosphere to enhance the %IACS values (electrical conductivity) and thermal performance of the bound metal MEX 3D printed copper heat sinks. The investigation combines experimental analysis, including simulations and heat transfer experiments, to gain insights into the structure-material property relationships and optimize the thermal performance of the printed heat sinks.

Ajjarapu, Kameswara Pavan Kumar [Oak Ridge Nationa↗

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing↗

Development & Experimental Validation of a Generalized Resistance-Capacitance Model for Numerical Simulation of Phase-Change Material Embedded Heat Exchangers

Latent heat thermal energy storage (LHTES) using phase change material (PCM) has attracted increased attention as a viable solution for overcoming the mismatch between energy supply and demand for renewable energy-based systems. PCM-embedded heat exchangers (PCM-HX) have the potential to significantly improve thermal performance due to high storage capacity and low temperature variation during the phase change process. Most models for simulating LHTES heat transfer use Computational Fluid Dynamics (CFD) simulations, which have high computational costs resulting from considering the complex and time-dependent physics relevant to PCM-HXs. In this paper, a Generalized Resistance Capacitance-based Model (GRCM) was developed to predict the thermal performance of arbitrary PCM-HXs in a computationally efficient manner without compromising modeling accuracy. The GRCM is exercised for three case studies: (i) verification for a single-slabbed finned PCM-HX, (ii) verification and validation for a copper foam/paraffin composite PCM-HX, and (iii) validation for a straight tube annular finned PCM-HX. The copper foam PCM-HX uses an electric heater at the top of HX, while the other two configurations utilize water as heat transfer fluid. For the single-slabbed finned PCM-HX melting case, the mean deviation in average PCM temperature predicted by the GRCM compared to the CFD model was between 0.56 – 0.73 K, with maximum temperature deviation of 2.68 K. For the HTF outlet temperature, the validation results showed that GRCM prediction matches very well with experimental data, with mean temperature deviation of 0.24 K during melting case, while for solidification case was 0.34 K. These results showcase the GRCM’s capability for accurately reproducing the thermal characteristics of PCM-HXs with considerably lower computational effort.

42 ENGINEERING↗

Ultra-clear Aerogels for Insulated Glass in Refrigeration Doors (CRADA Final Report)

Display refrigerators commonly employ glass doors to provide product visibility; however, these doors exhibit significantly poorer thermal insulation than solid doors, resulting in increased heat transfer and higher energy consumption. To address this limitation, this project investigated the use of silica aerogel as a transparent insulating medium for refrigerator glass doors, with the objective of enhancing thermal performance without compromising visual clarity. In Phase I of the project, we assessed the feasibility of silica aerogel insulation through laboratory and full-scale studies, including material characterization, durability testing, and heat transfer measurements, along with the development and performance evaluation of prototype glass doors under realistic operating conditions. In Phase II, the project focused on scaling the technology toward practical deployment. This included scaling up the manufacturing process to achieve a surface area roughly 20 times larger for commercial applications, developing full-scale prototypes that integrated silica aerogel into standard display refrigerator doors, and conducting field evaluations to assess thermal performance, energy savings, and operational durability under real-world conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.

Cort, Katherine↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗