Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “The Geysers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Liquid hydrogen slosh waves excited by constant reverse gravity acceleration of geyser initiation

The requirement to settle or to position liquid fuel over the outlet end of the spacecraft propellant tank before main engine restart poses a microgravity fluid behavior problem. Resettlement or reorientation of liquid propellant can be accomplished by providing the optimal acceleration to the spacecraft such that the propellant is reoriented over the tank outlet. In this study slosh wave excitation induced by the resettling flowfield during the course of liquid reorientation with the initiation of geyser for liquid-filled levels of 30, 50, 65, 70, and 80 percent have been studied. Characteristics of slosh waves with various frequencies excited are discussed. Slosh wave excitations will affect the fluid stress distribution exerted on the container wall and shift the fluid mass distribution inside the container, which imposes the time-dependent variations in the moment of inertia of the container. This information is important for the spacecraft control during the course of liquid reorientation.

Hung, R. J.↗

Tidal interaction: A possible explanation for geysers and other fluid phenomena in the Neptune-Triton system

Discovery of geyser-like plumes on the surface of Triton was a highlight of Voyager 2's passage through the Neptune planetary system. Remarkable as these observations were, they were not entirely without precedent. Considering the confirmed predictions for the 1979 Voyager Jovian passage, it was logical to consider other solar system bodies beside Io where tidal effects could be a significant factor in surface processes. It was our intuition that the Neptune-Triton gravitational bond acting at high inclination to the Neptune equator and the fact that Neptune was a fluid body was significant oblateness would produce tidal and mechanical forces that could be transformed into thermal energy vented on Triton's surface. Prior to the Voyager flyby, others have noted that capture and evolution of Triton's orbit from extreme eccentricity to near circular state today would have resulted in significant tidal heating, but these analysts disregard current day forces. Our calculations indicate that the time varying forces between Neptune-Triton fall midway between those exerted in the Earth-Moon and Jupiter-Io systems, and considering the low level of other energy inputs, this source of internal energy should not be ignored when seeking an explanation for surface activity. In each planet-satellite case, residual or steady-state eccentricity causes time-varying stresses on internal satellite strata. In the case of Jupiter the residual eccentricity is due largely to Galilean satellite interactions, particularly Io-Europa, but in the case of Neptune-Triton, it is the effect of Triton's inclined orbit about an oblate primary.

Kelly, W. D.↗

Slosh wave and geyser excitations due to liquid hydrogen shut-off during draining in microgravity

The dynamical behavior of liquid hydrogen shut-off during draining, and shut-off at the moment of the incipience of a suction dip have been investigated. It shows that a large amplitude surge is observed for liquid in the container at the moment of liquid hydrogen shut-off in reduced gravity. It also shows that slosh waves accompanied by a strong geyser are developed for surge-related flow fields induced by liquid hydrogen shut-off at the incipience of a suction dip. In the slosh wave excitation, both a lower gravity environment and higher flow rate before the shut-off of liquid draining are resonsible for the initiation of greater amplitude slosh waves. Slosh wave excitation, due to shut-off during liquid hydrogen draining, shift the fluid mass distribution in the container which imposes time-dependent variation in the spacecraft moment of inertia. This provides important information necessary for on-orbit guidance and attitude control of spacecraft.

Hung, R. J.↗

Geysering inhibitor pipe

Smaller concentric pipe is welded to main pipe beginning above bottom of isolation valve and terminating in storage tank at top. There is continuous circulation of fluid which maintains fluid temperature below boiling temperature of liquid oxygen.

Howard, F. S.↗

Medium-frequency impulsive-thrust-activated liquid hydrogen reorientation with Geyser

Efficient technique are studied for accomplishing propellant resettling through the minimization of propellant usage through impulsive thrust. A comparison between the use of constant-thrust and impulsive-thrust accelerations for the activation of propellant resettlement shows that impulsive thrust is superior to constant thrust for liquid reorientation in a reduced-gravity environment. This study shows that when impulsive thrust with 0.1-1.0-, and 10-Hz frequencies for liquid-fill levels in the range between 30-80 percent is considered, the selection of 1.0-Hz-frequency impulsive thrust over the other frequency ranges of impulsive thrust is the optimum. Characteristics of the slosh waves excited during the course of 1.0-Hz-frequency impulsive-thrust liquid reorientation were also analyzed.

Hung, R. J.↗

Ectomycorrhizal fungal associates of Pinus contorta in soils associated with a hot spring in Norris Geyser Basin, Yellowstone National Park, Wyoming

Molecular methods and comparisons of fruiting patterns (i.e., presence or absence of fungal fruiting bodies in different soil types) were used to determine ectomycorrhizal (EM) associates of Pinus contorta in soils associated with a thermal soil classified as ultra-acidic to extremely acidic (pH 2 to 4). EM were sampled by obtaining 36 soil cores from six paired plots (three cores each) of both thermal soils and forest soils directly adjacent to the thermal area. Fruiting bodies (mushrooms) were collected for molecular identification and to compare fruiting body (above-ground) diversity to below-ground diversity. Our results indicate (i) that there were significant decreases in both the level of EM infection (130 +/- 22 EM root tips/core in forest soil; 68 +/- 22 EM root tips/core in thermal soil) and EM fungal species richness (4.0 +/- 0.5 species/core in forest soil; 1.2 +/- 0.2 species/core in thermal soil) in soils associated with the thermal feature; (ii) that the EM mycota of thermal soils was comprised of a small set of dominant species and included very few rare species, while the EM mycota of forest soils contained a few dominant species and several rare EM fungal species; (iii) that Dermocybe phoenecius and a species of Inocybe, which was rare in forest soils, were the dominant EM fungal species in thermal soils; (iv) that other than the single Inocybe species, there was no overlap in the EM fungal communities of the forest and thermal soils; and (v) that the fungal species forming the majority of the above-ground fruiting structures in thermal soils (Pisolithus tinctorius, which is commonly used in remediation of acid soils) was not detected on a single EM root tip in either type of soil. Thus, P. tinctorius may have a different role in these thermal soils. Our results suggest that this species may not perform well in remediation of all acid soils and that factors such as pH, soil temperature, and soil chemistry may interact to influence EM fungal community structure. In addition, we identified at least one new species with potential for use in remediation of hot acidic soil.

Pinus/microbiology↗

Contact Angle Influence on Geysering Jets in Microgravity Investigated

Microgravity poses many challenges to the designer of spacecraft tanks. Chief among these are the lack of phase separation and the need to supply vapor-free liquid or liquid-free vapor to the spacecraft processes that require fluid. One of the principal problems of phase separation is the creation of liquid jets. A jet can be created by liquid filling, settling of the fluid to one end of the tank, or even closing a valve to stop the liquid flow. Anyone who has seen a fountain knows that jets occur in normal gravity also. However, in normal gravity, the gravity controls and restricts the jet flow. In microgravity, with gravity largely absent, surface tension forces must be used to contain jets. To model this phenomenon, a numerical method that tracks the fluid motion and the surface tension forces is required. Jacqmin has developed a phase model that converts the discrete surface tension force into a barrier function that peaks at the free surface and decays rapidly away. Previous attempts at this formulation were criticized for smearing the interface. This can be overcome by sharpening the phase function, double gridding the fluid function, and using a higher-order solution for the fluid function. The solution of this equation can be rewritten as two coupled Poisson equations that also include the velocity.

Chato, David J.↗

Behavior of Tidally Triggered Earthquakes Depends on Fluid Conditions

Seismicity at The Geysers geothermal field and in Oklahoma is heavily influenced by industrial activities related to energy production, though the mechanism in which earthquakes are induced or triggered is different. At The Geysers, much of the seismicity is linked to thermoelastic stresses caused by injecting cold water into hot rocks, whereas in Oklahoma, the seismicity is linked to a reduction of confining stress on faults due to increasing pore pressure resulting from wastewater injections. Here, in this study, we show that these contrasting conditions are also evident in tidally triggered earthquakes. At The Geysers, earthquakes preferentially occur during maximum extensional stress, which does not occur at the same time as maximum shear stress on optimally oriented faults in the regional stress field. In Oklahoma, earthquakes preferentially occur during maximum shear stress on optimally oriented faults rather than maximum extensional stress. The magnitude of tidal extensional stress is naturally much greater than tidal shear stress. However, in a fluid-saturated environment, pore pressure responds to changes in volume, which can counteract or reduce the effect of the applied stress. The difference in behavior at these two sites is indicative of the level of coupling between applied stress and pore pressure, corresponding to unsaturated conditions at The Geysers and high pore pressure in Oklahoma.

58 GEOSCIENCES↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Triton Hopper: Exploring Neptune's Captured Kuiper Belt Object

Neptune's moon Triton is a fascinating object, a dynamic moon with an atmosphere, and geysers. Triton is unique in the outer solar system in that it is most likely a captured Kuiper belt object (KBO), a leftover building block of the solar system. When Voyager flew by it was the coldest body yet found in our solar system (33 degrees Kelvin) and had volcanic activity, geysers, and a thin atmosphere. It is covered in ices made from nitrogen, water, and carbon-dioxide, and shows surface deposits of tholins, organic compounds that may be precursor chemicals to the origin of life. Exploring Triton will be a challenge well beyond anything done in previous missions; but the unique environment of Triton also allows some new possibilities for mobility. We developed a conceptual design of a Triton Hopping probe that both analyzes the surface and collects it for use to propel its hops. The Hopper would land near the South Pole in 2040 where geysers have been detected. Depending the details of propulsion chosen the Hopper should be able to jump over 300 kilometers in 60 hops or less, exploring the surface and thin atmosphere on its way. This craft will autonomously carry out detailed scientific investigations on the surface, below the surface (drilling) and in the upper atmosphere to provide unprecedented knowledge of a KBO-turned moon and expanding NASA's existing capabilities in deep space planetary exploration to include Hoppers using different ices for propellant. Triton is roughly 2700 kilometers in diameter with a surface of mostly frozen nitrogen, mostly water ice crust and core of metal and rock. Its gravity is half that of Earth's Moon and its atmosphere is 170,000th of Earth's or 0.3 of Mars.The mission concept studied investigated the full surface and atmospheric phenomenon: chemical composition of surface and near subsurface materials, the thin atmosphere, volcanic and geyser activity. Measurements of all these aspects of Triton's unique environment can only be made through focused in-situ exploration with a well-instrumented craft. And this craft will be provided revolutionary mobility, nearly global, using in-situ ices as propellants. While other concepts have looked at gathering gases at Mars to propel a hopper, long periods of time are needed to gather the thin CO2 atmosphere. Several gases, mainly nitrogen are on the surface in a readily dense ice form and just need to be picked up, vaporized and used for propellant.

low conductivity materials↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Liquid propellant reorientation in a low-gravity environment

An existing empirical analysis relating to the reorientation of liquids in cylindrical tanks due to propulsive settling in a low gravity environment was extended to include the effects of geyser formation in the Weber number range from 4 to 10. Estimates of the minimum velocity increment required to be imposed on the propellant tank to achieve liquid reorientation were made. The resulting Bond numbers, based on tank radius, were found to be in the range from 3 to 5, depending upon the initial liquid fill level, with higher Bond number required for high initial fill levels. The resulting Weber numbers, based on tank radius and the velocity of the liquid leading edge, were calculated to be in the range from 6.5 to 8.5 for cylindrical tanks having a fineness ratio of 2.0, with Weber numbers of somewhat greater values for longer cylindrical tanks. It, therefore, appeared to be advantageous to allow small geysers to form and then dissipate into the surface of the collected liquid in order to achieve the minimum velocity increment. The Bond numbers which defined the separation between regions in which geyser formation did and did not occur due to propulsive settling in a spherical tank configuration ranged from 2 to 9 depending upon the liquid fill level.

Sumner, I. E.↗