Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Fixture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Vacuum test fixture improves leakage rate measurements

Cylindrical chamber, consisting of two matching halves, forms a vacuum test fixture for measuring leakage rates of individual connections, brazed joints, and entrance ports used in closed fluid flow line systems. Once the chamber has been sufficiently evacuated, atmospheric pressure holds the two halves together.

Maier, H.↗

Shear-Panel Test Fixture Eliminates Corner Stresses

New design eliminates corner stresses while maintaining uniform stress across panel. Shear panel test fixture includes eight frames and eight corner pins. Fixture assembled in two halves with shear panel sandwiched in between. Results generated from this fixture will result in good data base for design of efficient aircraft structures and other applications.

Kiss, J. J.↗

Preliminary eddy current modelling for the large angle magnetic suspension test fixture

This report presents some recent developments in the mathematical modeling of the Large Angle Magnetic Suspension Test Fixture (LAMSTF) at NASA Langley Research Center. It is shown that these effects are significant, but may be amenable to analysis, modeling and measurement. A theoretical framework is presented, together with a comparison of computed and experimental data.

Britcher, Colin↗

The F-15B Propulsion Flight Test Fixture: A New Flight Facility For Propulsion Research

The design and development of the F-15B Propulsion Flight Test Fixture (PFTF), a new facility for propulsion flight research, is described. Mounted underneath an F-15B fuselage, the PFTF provides volume for experiment systems and attachment points for propulsion devices. A unique feature of the PFTF is the incorporation of a six-degree-of-freedom force balance. Three-axis forces and moments can be measured in flight for experiments mounted to the force balance. The NASA F-15B airplane is described, including its performance and capabilities as a research test bed aircraft. The detailed description of the PFTF includes the geometry, internal layout and volume, force-balance operation, available instrumentation, and allowable experiment size and weight. The aerodynamic, stability and control, and structural designs of the PFTF are discussed, including results from aerodynamic computational fluid dynamic calculations and structural analyses. Details of current and future propulsion flight experiments are discussed. Information about the integration of propulsion flight experiments is provided for the potential PFTF user.

Corda, Stephen↗

Applications of the IITRI compression test fixture at elevated temperature

The purpose of the present paper is to describe an application of the IITRI compression test fixture at elevated temperature (589K) was described as well as the present compressive moduli and ultimate strains of HTS/PMR-15 graphite/polyimide material. Considerable care was taken in specimen fabrication to minimize back-to-back strain variations due to specimen bending. The effects of specimen width and temperature were studied for various laminate orientations. The IITRI specimen was analyzed using three dimensional finite elements to determine the magnitude and location of stress concentrations to assess their potential effects on measured moduli and ultimate strains. Stress concentrations are of concern since end constraints, free-edge effects, and thermal effects add to the three dimensional nature of stresses in a specimen.

Camarda, C. J.↗

Local Flow Conditions for Propulsion Experiments on the NASA F-15B Propulsion Flight Test Fixture

Local flow conditions were measured underneath the National Aeronautics and Space Administration F-15B airplane to support development of future experiments on the Propulsion Flight Test Fixture (PFTF). The local Mach number and flow angles were measured using a conventional air data boom on a cone-cylinder mounted under the PFTF and compared with the airplane air data nose boom measurements. At subsonic flight speeds, the airplane and PFTF Mach numbers were approximately equal. Transonic Mach number values were up to 0.1 greater at the PFTF than the airplane, which is a counterintuitive result. The PFTF local supersonic Mach numbers were as much as 0.46 less than the airplane values. The maximum local Mach number at the PFTF was approximately 1.6 at an airplane Mach number near 2.0. The PFTF local angle of attack was negative at all Mach numbers, ranging from -3 to -8 degrees. When the airplane angle of sideslip was zero, the PFTF local value was zero between Mach 0.8 and Mach 1.1, -2 degrees between Mach 1.1 and Mach 1.5, and increased from zero to 1 degree from Mach 1.5 to Mach 2.0. Airplane inlet shock waves crossed the aerodynamic interface plane between Mach 1.85 and Mach 1.90.

Vachon, Michael J.↗

Large angle magnetic suspension test fixture

Progress made under the subject grant in the period from 1 Nov. 1992 to 31 May 1993 is presented. The research involves the continued development of the Large Angle Magnetic Suspension Test Fixture (LAMSTF) and also the recommissioning of an additional piece of exisiting hardware. During the period in question, the initial configuration of LAMSTF was completed and made routinely and reliably operational. A digital phase advance controller was completed and documented. The goal of a controlled 360 deg rotation was achieved. Work started on the recommissioning of the Annular Suspension and Pointing System (ASPS). Work completed during the report period included: modeling; position sensing; controller; support of the Second International Symposium on Magnetic Suspension Technology; and recommissioning of the Annular Suspension and Pointing System.

Britcher, Colin P.↗

Configuration and Sizing of a Test Fixture for Panels Under Combined Loads

Future air and space structures are expected to utilize composite panels that are subjected to combined mechanical loads, such as bi-axial compression/tension, shear and pressure. Therefore, the ability to accurately predict the buckling and strength failures of such panels is important. While computational analysis can provide tremendous insight into panel response, experimental results are necessary to verify predicted performances of these panels to judge the accuracy of computational methods. However, application of combined loads is an extremely difficult task due to the complex test fixtures and set-up required. Presented herein is a comparison of several test set-ups capable of testing panels under combined loads. Configurations compared include a D-box, a segmented cylinder and a single panel set-up. The study primarily focuses on the preliminary sizing of a single panel test configuration capable of testing flat panels under combined in-plane mechanical loads. This single panel set-up appears to be best suited to the testing of both strength critical and buckling critical panels. Required actuator loads and strokes are provided for various square, flat panels.

Lovejoy, Andrew E.↗

Modelling of eddy currents related to large angle magnetic suspension test fixture

This report presents a preliminary analysis of the mathematical modelling of eddy current effects in a large-gap magnetic suspension system. It is shown that eddy currents can significantly affect the dynamic behavior and control of these systems, but are amenable to measurement and modelling. A theoretical framework is presented, together with a comparison of computed and experimental data related to the Large Angle Magnetic Suspension Test Fixture at NASA Langley Research Center.

Britcher, Colin P.↗

Test fixture for determination of energy absorbing capabilities of composite materials

The present invention provides a fixture for supporting an elongated specimen for crush testing. The fixture comprises a base plate, four guiding rods, a sliding plate, four support rods and two collars. The guiding rods connect to the base plate and extend in a direction substantially perpendicular to the base plate. The sliding plate has linear bearings which encircle the guiding rods and enable translation of the sliding plate along the axis of each guiding rod. The four supporting rods mount to the base plate and also extend in a direction substantially perpendicular to the base plate. Each support rod has a keyway for a wedge which contacts the elongated specimen and holds the specimen in place during crushing. Each collar lies above the sliding plate and holds a pair of support rods on their ends opposite the ends connected to the base plate. A spherical bearing sits on top of the sliding plate and transfers an applied load to the sliding plate, which moves downward and crushes the elongated specimen.

Lavoie, J. Andre↗

Test Fixture for Determination of Energy Absorbing Capabilities of Composite Materials

The present invention provides a fixture for supporting an elongated specimen for crush testing. The fixture comprises a base plate. four guiding rods, a sliding plate, four support rods and two collars. The guiding rods connect to the base plate and extend in a direction substantially perpendicular to the base plate. The sliding plate has linear bearings which encircle the guiding rods and enable translation of the sliding plate along the axis of each guiding rod. The four supporting rods mount to the base plate and also extend in a direction substantially perpendicular to the base plate. Each support rod has a keyway for a wedge which contacts the elongated specimen and holds the specimen in place during crushing. Each collar lies above the sliding plate and holds a pair of support rods on their ends opposite the ends connected to the base plate. A spherical bearing sits on top of the sliding plate and transfers an applied load to the sliding plate, which moves downward and crushes the elongated specimen.

Lavoie, J. Andre↗

Universal nondestructive mm-wave integrated circuit test fixture

Monolithic microwave integrated circuit (MMIC) test includes a bias module having spring-loaded contacts which electrically engage pads on a chip carrier disposed in a recess of a base member. RF energy is applied to and passed from the chip carrier by chamfered edges of ridges in the waveguide passages of housings which are removably attached to the base member. Thru, Delay, and Short calibration standards having dimensions identical to those of the chip carrier assure accuracy and reliability of the test. The MMIC chip fits in an opening in the chip carrier with the boundaries of the MMIC lying on movable reference planes thereby establishing accuracy and flexibility.

Romanofsky, Robert R.↗

O-ring gasket test fixture

An apparatus is presented for testing O-ring gaskets under a variety of temperature, pressure, and dynamic loading conditions. Specifically, this apparatus has the ability to simulate a dynamic loading condition where the sealing surface in contact with the O-ring moves both away from and axially along the face of the O-ring.

Turner, James Eric↗

A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components

The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.

Mejia, M.↗

Resistance-Welding Test Fixture

Realistic welding conditions produce reliable specimens. Simple fixture holds resistance-welding test specimens. Specimen holder includes metallic holder and clamps to provide electrical and thermal paths and plastic parts providing thermal and electrical isolation.

Brennan, Andrew D.↗

Detection of Damage Inducing Impact Events in Vibration Test Fixtures Using Holder Exponents

The Shock and Vibration team within the Test Engineering group at Los Alamos National Laboratory (LANL) aids in the development and qualification of weapon systems for the United States Department of Energy (DOE). Performing tests that replicate shock and vibration environments representative of a weapon’s lifetime is critical in ensuring safety, survivability, and reliability. A key factor in shock and vibration testing is accurate representation of the weapon’s boundary conditions in its end use configuration. The boundary conditions representative of a reentry body in flight are particularly difficult to replicate on an electrodynamic shaker. When executing shock and vibration tests on a reentry body, two system axes are tested with the system in a cantilevered configuration. This cantilevered testing configuration results in a moment load being applied to the system while undergoing vibration environments. A special fixture, known as the Flex-Web, was developed to decouple this moment load from the reentry body in order to more accurately represent real world boundary conditions while replicating flight environments.

42 ENGINEERING↗