Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Temperature variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Effect of design variables, temperature gradients, and speed on life and reliability of a rotating disk

A generalized methodology to predict the fatigue life and reliability of a rotating disk such as used for aircraft engine turbines and compressors is advanced. The approach incorporates the computed life of elemental stress volumes to predict system life and reliability. Disk speed and thermal gradients as well as design varibles such as disk diameter and thickness and bolt hole size, number and location are considered.

Zaretsky, E. V.

Variable temperature pressure broadening of HNO3 in the millimeter wave spectral region

Measurements were performed for both O2 and N2 broadening in the 100-380 K temperature range by using a heated equilibrium cell for elevated temperatures and the utilization of a collisionally cooled cell at the lower temperatures where HNO3 has a small vapor pressure. Observed pressure-broadening data can be fit to the normal empirical law, giving n values between 0.62 and 0.84.

Goyette, Thomas M.

A YBCO RF-squid variable temperature susceptometer and its applications

The Superconducting QUantum Interference Device (SQUID) susceptibility using a high-temperature radio-frequency (rf) SQUID and a normal metal pick-up coil is employed in testing weak magnetization of the sample. The magnetic moment resolution of the device is 1 x 10(exp -6) emu, and that of the susceptibility is 5 x 10(exp -6) emu/cu cm.

Zhou, Luwei

Variable temperature pressure broadening of the 4(1,4)-3(2,1) transition of H2O by O2 and N2

The O2 and N2 pressure-broadening parameters of the 4(1,4)-3(2,1) rotational transition in the ground vibrational state of H2O have been measured in the temperature range between 100 and 520 K. Above 250 K the measurements were made in an equilibrium cell. Below 250 K a cell, which uses collisional cooling to circumvent the temperature limits imposed by the vapor pressure of the sample gas, was used. The data were fitted to an exponential temperature-dependence for data above 150 K with resultant n values of 0.81(3) for O2 and 0.70(3) for N2, where the entries in parentheses represent the error in the last significant figure of the parameter. Below 150 K the measured pressure-broadening parameters are smaller than those calculated using these values of n.

Goyette, Thomas M.

Variable Temperature Performance of a Si(Li) Detector Stack

New experimental data is presented which displays 137Cs resolution of both single Si(Li) devices and a detector stack 2 cm in height as a function of temperature (85 K greater than or equal to T greater than or equal to 245 K). We also discuss variations in photopeak shape which indicate that detector charge collection may be temperature dependent over the range of interest.

Hubbard, G. Scott

Performance of a Herriott Cell, Designed for Variable Temperatures between 296 and 20 K

We designed, fabricated and tested a multipath Herriott cell (or off-axis spherical mirror interferometer) to achieve low temperature absorption measurements. The cell is fabricated entirely from copper and the 15 cm radius of curvature copper mirrors have gold coated reflective surfaces. The cell was tested at temperatures between 296 and 30 K with a folded absorption path length of 5.37 m utilizing a lead salt tunable diode laser. Short term temperature stability (1 h) of the Herriott cell is better than 0.005 K under normal operating conditions with a temperature uniformity better than 0.01 K (not measurable). The cell was tested by performing collisional cooling experiments on 13C16O2 in helium at temperatures between 70 and 20 K and by performing more traditional pressure broadening and shift measurements on molecular infrared absorption lines at temperatures between 300 and about 80 K on 13C16O2 methane.

Mondelain, Didier

Soil Moisture Controls on Rainfall and Temperature Variability: A Modeler Searches Through Observational Data

The degree to which atmospheric processes respond to variations in soil moisture - a potentially important but largely untapped element of subseasonal to seasonal prediction - can be determined easily and directly for an atmospheric model but cannot be determined directly for nature through an analysis of observations. In atmospheric models) directions of causality can be artificially manipulated; we can avoid difficulties associated with the fact that atmospheric variations have a much larger impact on land state variations than vice-versa. In nature) on the other hand) the dominant direction of causality (the atmosphere forcing the ground) cannot be artificially "turned off") and the statistics associated with this dominant direction overwhelm those of the feedback signal. Observational data) however) do allow a number of indirect measures of landatmosphere feedback. This seminar reports on a series of joint analyses of observational and model data designed to illuminate the degree of land-atmosphere feedback present in the real world. The indirect measures do in fact suggest that feedback in nature, though small) is significant - enough to warrant the development of realistic land initialization strategies for subseasonal and seasonal forecasts.

Koster, Randal

Tack Measurements of Prepreg Tape at Variable Temperature and Humidity

NASA’s Advanced Composites Project has established the goal of achieving a 30 percent reduction in the timeline for certification of primary composite structures for application on commercial aircraft. Prepreg tack is one of several critical parameters affecting composite manufacturing by automated fiber placement (AFP). Tack plays a central role in the prevention of wrinkles and puckers that can occur during AFP, thus knowledge of tack variation arising from a myriad of manufacturing and environmental conditions is imperative for the prediction of defects during AFP. A full design of experiments was performed to experimentally characterize tack on 0.25-inch slit-tape tow IM7/8552-1 prepreg using probe tack testing. Several process parameters (contact force, contact time, retraction speed, and probe diameter) as well as environmental parameters (temperature and humidity) were varied such that the entire parameter space could be efficiently evaluated. Mid-point experimental conditions (i.e., parameters not at either extrema) were included to enable prediction of curvature in relationships and repeat measurements were performed to characterize experimental error. Collectively, these experiments enable determination of primary dependencies as well as multi-parameter relationships. Slit-tape tow samples were mounted to the bottom plate of a rheometer parallel plate fixture using a jig to prevent modification of the active area to be interrogated with the top plate, a polished stainless steel probe, during tack testing. The probe surface was slowly brought into contact with the pre-preg surface until a pre-determined normal force was achieved (2-30 newtons). After a specified dwell time (0.02-10 seconds), during which the probe substrate interaction was maintained under displacement control, the probe was retracted from the surface (0.1-50 millimeters per second). Initial results indicated a clear dependence of tack strength on several parameters, with a particularly strong dependence on temperature and humidity. Although an increase in either of these parameters reduces tack strength, a maximum in tack was predicted to occur under conditions of low temperature and moderate humidity.

Wohl, Christopher

Impacts of Water Clarity Variability on Temperature and Biogeochemistry in the Chesapeake Bay

Estuarine water clarity depends on the concentrations of aquatic constituents, such as colored dissolved organic matter, phytoplankton, inorganic suspended solids, and detritus, which are influenced by variations in riverine inputs. These constituents directly affect temperature because when water is opaque, sunlight heats a shallower layer of the water compared to when it is clear. Despite the importance of accurately predicting temperature variability, many numerical modeling studies do not adequately account for this key process. In this study, we quantify the effect of water clarity on heating by comparing two simulations of a hydrodynamic-biogeochemical model of the Chesapeake Bay for the years 2001–2005, in which (1) water clarity is constant in space and time for the computation of solar heating, compared to (2) a simulation where water clarity varies with modeled concentrations of light-attenuating materials. In the variable water clarity simulation, the water is more opaque, particularly in the northern region of the Bay. This decrease in water clarity reduces the total heat, phytoplankton, and nitrate throughout the Bay. During the spring and summer months, surface temperatures in the northern Bay are warmer by 0.1 °C and bottom temperatures are colder by 0.2 °C in the variable light attenuation simulation. Warmer surface temperatures encourage phytoplankton growth and nutrient uptake near the head of the Bay, and fewer nutrients are transported downstream. These impacts are greater during higher river flow years, when differences in temperature, nutrients, phytoplankton, and zooplankton extend further seaward compared to other years. This study demonstrates the consequences of utilizing different light calculations for estuarine heating and biogeochemistry.

water clarity

Nature of the Reactive Biferric Peroxy Intermediate P′ in the Arylamine Oxygenases and Related Binuclear Fe Enzymes

Binuclear nonheme iron enzymes activate O 2 to perform a wide range of chemical transformations. The process of O 2 activation typically involves a biferric peroxy-level intermediate P. It has been previously found that this intermediate undergoes further activation, either protonation or rearrangement to form P′ or further oxidation to form high-valent intermediates Q or X. Here, this study defines the structure of the P′ intermediate in the N-oxygenases CmlI (and AurF based on previous data) using nuclear resonance vibrational spectroscopy (NRVS) in conjugation with density functional theory (DFT) calculations. These results, combined with variable temperature variable field (VTVH) magnetic circular dichroism (MCD) spectroscopy on the 1-electron cryoreduced P′, define the structure of the P′ intermediate as a μ-1,2-hydroxoperoxo biferric site with a second hydroxide bridge. Reaction coordinate calculations demonstrate that single electron transfer (SET) is facilitated by protonation of the peroxo, activating its reductive cleavage, and that the additional hydroxide bridge does not impact this reaction. VTVH MCD studies further reveal that the hydroxide bridge is absent in the biferrous site, suggesting that during the O 2 reaction with the biferrous site, a water molecule forms the hydroxide bridge in providing the proton that activates the peroxide in P′ for reactivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Analytic Couple Modeling Introducing Device Design Factor, Fin Factor, Thermal Diffusivity Factor, and Inductance Factor

A set of convenient thermoelectric device solutions have been derived in order to capture a number of factors which are previously only resolved with numerical techniques. The concise conversion efficiency equations derived from governing equations provide intuitive and straight-forward design guidelines. These guidelines allow for better device design without requiring detailed numerical modeling. The analytical modeling accounts for factors such as i) variable temperature boundary conditions, ii) lateral heat transfer, iii) temperature variable material properties, and iv) transient operation. New dimensionless parameters, similar to the figure of merit, are introduced including the device design factor, fin factor, thermal diffusivity factor, and inductance factor. These new device factors allow for the straight-forward description of phenomenon generally only captured with numerical work otherwise. As an example a device design factor of 0.38, which accounts for thermal resistance of the hot and cold shoes, can be used to calculate a conversion efficiency of 2.28 while the ideal conversion efficiency based on figure of merit alone would be 6.15. Likewise an ideal couple with efficiency of 6.15 will be reduced to 5.33 when lateral heat is accounted for with a fin factor of 1.0.

Seebeck effect

Fracture mechanics criteria for turbine engine hot section components

The application of several fracture mechanics data correlation parameters to predicting the crack propagation life of turbine engine hot section components was evaluated. An engine survey was conducted to determine the locations where conventional fracture mechanics approaches may not be adequate to characterize cracking behavior. Both linear and nonlinear fracture mechanics analyses of a cracked annular combustor liner configuration were performed. Isothermal and variable temperature crack propagation tests were performed on Hastelloy X combustor liner material. The crack growth data was reduced using the stress intensity factor, the strain intensity factor, the J integral, crack opening displacement, and Tomkins' model. The parameter which showed the most effectiveness in correlation high temperature and variable temperature Hastelloy X crack growth data was crack opening displacement.

Meyers, G. J.