Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature reactivity coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

41 records · Page 3

The Iodine Satellite (iSAT) Propellant Feed System - Design and Development

The development, modeling, and testing of components and subsystems required to feed iodine propellant to a 200-W Hall thruster and cathode are described. This work aims to address design deficiencies and issues associated with the propellant feed system that were revealed by an integrated thruster-cathode-feed system test. The feed system design is modified to use materials that are more resistant to the highly-reactive nature of iodine propellant. Dynamic modeling indicates that the inclusion of additional constraints on feed system tubing will reduce the vibrationally-induced stresses that occur during launch. Full spacecraft thermal modeling show that the feed system heater power levels are sufficient to heat the tank and propellant lines to operating temperatures, where iodine in the tank is sublimed to supply propellant for operation and the tubing is elevated in temperature to keep propellant from redepositing to block the flow. Experiments are conducted to demonstrate that is it possible through the application of heating to clear an iodine deposit blocking the flow. Deposits in the low-pressure portion of the system near the exit to vacuum are shown to be relatively easy to remove in this manner while blockages forming upstream nearer to the higher-pressure propellant tank require significantly more effort to remove. Fluid flow modeling of the feed system is performed, exhibiting some qualitative agreement with experimental data. However, the highly viscous nature of the fluid flow and the dependence of the component flow coefficients on the Reynolds number are likely causes of the generally-poor quantitative agreement between the modeling results and experimentally-measured fluid flow properties.

Polzin, Kurt A.↗

High Temperature - Thin Film Strain Gages Based on Alloys of Indium Tin Oxide

A stable, high temperature strain gage based on reactively sputtered indium tin oxide (ITO) was demonstrated at temperatures up to 1050 C. These strain sensors exhibited relatively large, negative gage factors at room temperature and their piezoresistive response was both linear and reproducible when strained up to 700 micro-in/in. When cycled between compression and tension, these sensors also showed very little hysteresis, indicating excellent mechanical stability. Thin film strain gages based on selected ITO alloys withstood more than 50,000 strain cycles of +/- 500 micro-in/in during 180 hours of testing in air at 1000 C, with minimal drift at temperature. Drift rates as low as 0.0009%/hr at 1000 C were observed for ITO films that were annealed in nitrogen at 700 C prior to strain testing. These results compare favorably with state of the art 10 micro-m thick PdCr films deposited by NASA, where drift rates of 0.047%/hr at 1050 C were observed. Nitrogen annealing not only produced the lowest drift rates to date, but also produce the largest dynamic gage factors (G = 23.5). These wide bandgap, semiconductor strain sensors also exhibited moderately low temperature coefficients of resistance (TCR) at temperatures up to 1100 C, when tested in a nitrogen ambient. A TCR of +230 ppm/C over the temperature range 200 C < T < 500 C and a TCR of -469 ppm/C over the temperature range 600 C < T < 1100 C was observed for the films tested in nitrogen. However, the resistivity behavior changed considerably when the same films were tested in oxygen ambients. A TCR of -1560 ppm/C was obtained over the temperature range of 200 C < T < 1100 C. When similar films were protected with an overcoat or when ITO films were prepared with higher oxygen contents in the plasma, two distinct TCR's were observed. At T < 800 C, a linear TCR of -210 ppm/C was observed and at T > 800 C, a linear TCR of -2170 DDm/C was observed. The combination of a moderately low TCR and a relatively large gage factor make these semiconducting oxide films promising candidates for the active strain elements in high temperature thin film strain gages, particularly in applications where static strain measurement is desired.

Gregory, Otto J.↗

Low Temperature Unbalanced Magnetron Deposition of Hard, Wear-Resistant Coatings for Liquid-Film Bearing Applications

The original program for evaluating the tribological properties several different hard coatings for liquid film bearing applications was curtailed when the time for the program was reduced from 3 years to 1. Of the several different coatings originally planned for evaluation, we decided to concentrate on one coating, carbon nitride. At BIRL, we have been instrumental in the development of reactively sputtered carbon nitride coatings, and we have found that it is a very interesting new material with very good tribological properties. In this program, we found that the reactively sputtered carbon nitride does not bond well directly to hardened 440C stainless steel; but if an interlayer of titanium nitride is added between the carbon nitride and the 440C, the adhesion of the dual coating combination is very good. Statistically designed experiments were run with the dual layer combination, and 3 variables were chosen for the Box-Benken design, which were the titanium nitride interlayer thickness, the nitrogen partial pressure during the reactive sputtering of the carbon nitride, and the carbon nitride substrate bias voltage. Two responses were studied from these three variables; the adhesion of the dual coating combination to the 440C substrate and the friction coefficient of the carbon nitride in dry sliding contact with 52100 steel in air. The best adhesion came with the thickness interlayer thickness studied, which was 4 micrometers, and the lowest coefficient of friction was 0.1, which was achieved when the bias voltage was in the range of -80 to - 120 V and the nitrogen partial pressure was 3 mTorr.

Sproul, William D.↗

Molecular Processes in Comets

The research focused on molecular hydrogen and its response to ultraviolet radiation, photoelectron impact excitation and X-ray radiation and on the interpretation of the ultraviolet spectra of the Jupiter dayglow and auroras. A systematic effort was made to obtain reliable rate coefficients for rovibrational energy transfer of H2, particularly in collisions with hydrogen atoms. We carried out elaborate quantum-mechanical calculations of the scattering of H and H2 on what had been characterized as a reliable potential energy surface of the H3 molecular system. These calculations took into account reactive channels and rate coefficients for ortho-para transitions were obtained. Quantal calculations are too complex to be applied to all the possible rovibrational transitions and we turned to a semi-classical method. With it we calculated rate coefficients for transitions, reactive and non-reactive, for all the rovibrational levels. We carried out the calculations for three of the available H3 potential energy surfaces. We discovered an unexpected sensitivity of the rate coefficients for the non-reactive channels to the potential energy surface. This discovery stimulated more thorough investigations of the potential energy surface elsewhere and to the construction of a new surface. We have used it in further semi-classical calculations in work that will shortly be 2 completed and which, together with new quantum-mechanical calculations should comprise a set of reliable rate coefficients that can be used in discussions of H2 on the Jovian planets. We carried out a detailed study of the Jovian ultraviolet dayglow. There has been a long-running argument about the dayglow on Jupiter. There are two sources of excitation: fluorescence and photoelectron impact excitation. It had been argued that a third source "the electron glow" was needed to bring theory and observation into agreement. We believe we have shown conclusively that the third source is unnecessary. We have achieved a close quantitative agreement between the predicted spectrum arising from fluorescence and photoelectrons and the measured spectrum. We also demonstrated a method by which the presence of HD could be established observationary. Similar calculations were carried out of the ultraviolet spectra of the Jovian auroras. We again found close agreement. Indeed, the agreement was so detailed we were able to derive the temperature of the atmosphere. We found, contrary to the standard model of the time, a high temperature between 400 K and 600 K and established the presence of a significant temperature gradient. A large temperature gradient was indeed found by direct sampling with the Jupiter probe.

Dalgarno, A.↗

Halogen-Containing Gases as Boundary Lubricants for Corrosion-Resistant Alloys at 1200 F

The extreme temperatures anticipated for lubricated parts in advanced flight powerplants dictate the consideration of unconventional methods of lubrication such as solid lubricants and the reactive gases described in the present research. These halogen-containing "reactive" gases such as dichlorodifluoromethane, CF2Cl2, are among the most stable of organic molecules. The high "flash" temperatures generated at the contacting asperities as a result of frictional heat are sufficient to cause local decomposition of the halogen-containing gases. The active atoms thus released (e.g., chlorine) then react with the metal to be lubricated to form halides capable of effective lubrication. The presence of small amounts of a sulfur-containing gas (e.g., 1 percent sulfur hexafluoride, SF6) was found to catalyze the formation of metal halides. Friction and wear studies were made with a hemisphere (3/16-in. rad.) rider sliding in a circumferential path on the flat surface of a rotating disk (2 1/2-in. diam.). The specimens of corrosion-resistant 2 alloys were run in an atmosphere of the various gases with a load of 1200 grams, a sliding velocity of 120 feet per minute, and temperature from 75 to 1200 F. An effective lubricant for ferritic materials (M-1 tool steel) was CF2Cl2, but significant corrosion occurred above 600 F. Corrosion evaluation in CF2Cl2 suggested a number of nickel- and cobalt-base alloys for additional lubrication study. Several combinations of gases and these metals were found to lubricate to 1200 F without excessive corrosion. The gases were CF2Cl2 Plus 1 percent SF6, monobromotrifluoromethane CF3Br plus 1 percent SF6, dibromodifluoromethane CF2Br2, iodotrifluoromethane, CF3I, and I2. Careful selection of metals and gas are necessary for successful lubrication over specific temperature ranges. Optimum combinations give friction coefficients as low as 0.05 without

Buckley, Donald H.↗