Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A new approach to the pulsed thermocouple for high gas temperature measurements

Pulsed thermocouple systems can be used to measure gas temperatures above the melting point of the thermocouple by various techniques of short term of intermittent exposure of the thermocouple operating at lower temperatures. An approach is described which uses a thermocouple cooled by a small jet of inert gas. When a measurement is to be made, the cooling jet is turned off and the thermocouple allowed to heat up to near its melting point, at which time the cooling is reapplied. The final temperature which the thermocouple should have attained is then calculated by extrapolating an exponential curve fit to the data. Temperature measurements can be recorded and displayed in near real time by using modern high-speed computing systems to perform these calculations. Examples of the technique applied to high temperature jet engine combustor development are presented.

Glawe, G. E.↗

A new approach to the pulsed thermocouple for high gas temperature measurements

Pulsed thermocouple systems can be used to measure gas temperatures above the melting point of the thermocouple by various techniques of short term or intermittent exposure of the thermocouple operating at lower temperatures. This paper describes an approach which uses a thermocouple cooled by a small jet of inert gas. When a measurement is to be made, the cooling jet is turned off and the thermocouple allowed to heat up to near its melting point, at which time the cooling is reapplied. The final temperature which the thermocouple should have attained is then calculated by extrapolating an exponential curve fit to the data. Temperature measurements can be recorded and displayed in near real time by using modern high-speed computing systems to perform these calculations. Examples of the technique applied to high temperature jet engine combustor development are presented.

Glawe, G. E.↗

Laser Pyrometer For Spot Temperature Measurements

Laser pyrometer makes temperature map by scanning measuring spot across target. Scanning laser pyrometer passively measures radiation emitted by scanned spot on target and calibrated by similar passive measurement on blackbody of known temperature. Laser beam turned on for active measurements of reflectances of target spot and reflectance standard. From measurements, temperature of target spot inferred. Pyrometer useful for non-contact measurement of temperature distributions in processing of materials.

Elleman, D. D.↗

Turbine Blade Temperature Measurements Using Thin Film Temperature Sensors

The development of thin film temperature sensors is discussed. The technology for sputtering 2 micron thin film platinum versus platinum 10 percent rhodium thermocouples on alumina forming coatings was improved and extended to applications on actual turbine blades. Good adherence was found to depend upon achieving a proper morphology of the alumina surface. Problems of adapting fabrication procedures to turbine blades were uncovered, and improvements were recommended. Testing at 1250 K at one atmosphere pressure was then extended to a higher Mach No. (0.5) in combustor flow for 60 hours and 71 thermal cycles. The mean time to failure was 47 hours accumulated during 1 hour exposures in the combustor. Calibration drift was about 0.1 percent per hour, attributable to oxidation of the rhodium in the thin films. An increase in film thickness and application of a protective overcoat are recommended to reduce drift in actual engine testing.

Grant, H. P.↗

Thermospheric temperature measurement technique.

A method for measurement of temperature in the earth's lower thermosphere from a high-velocity probes is described. An undisturbed atmospheric sample is admitted to the instrument by means of a free molecular flow inlet system of skimmers which avoids surface collisions of the molecules prior to detection. Measurement of the time-of-flight distribution of an initially well-localized group of nitrogen metastable molecular states produced in an open, crossed electron-molecular beam source, yields information on the atmospheric temperature. It is shown that for high vehicle velocities, the time-of-flight distribution of the metastable flux is a sensitive indicator of atmospheric temperature. The temperature measurement precision should be greater than 94% at the 99% confidence level over the range of altitudes from 120-170 km. These precision and altitude range estimates are based on the statistical consideration of the counting rates achieved with a multichannel analyzer using realistic values for system parameters.

Hueser, J. E.↗

Atmospheric noise temperature measurements

Radiometric microwave noise temperature measurements were used to estimate atmospheric transmission loss. The following lumped element model expression is used for the noise temperature contribution, T double prime = T sub p (1 - 1/L). This relationship is used to estimate the transmission loss L in terms of T double prime and the atmosphere effective physical temperature T sub p. This report evaluates T sub p in terms of assumed distributed loss and temperature models. Simplified expressions are presented for low loss applications. For these applications L was determined directly and accurately without integration or iteration.

Stelzried, C.↗

Effect of turbulence on line-reversal temperature measurements

The effect of turbulent temperature fluctuations on line-reversal temperature measurements is examined in the thin gas, small fluctuation limit. It is shown that in this limit the fluctuations have no effect on the time average results. Only in case of a spacially uniform temperature can the fluctuating component of the temperature be directly measured. For the case of a spacially uniform mean temperature, a spacial average of the fluctuating component can be measured. For the completely nonuniform case, only a complex spacial average of the fluctuating and mean temperatures can be measured.

Daily, J. W.↗

Dynamic gas temperature measurement system

A gas temperature measurement system with compensated frequency response of 1 KHz and capability to operate in the exhaust of a gas turbine combustor was developed. Environmental guidelines for this measurement are presented, followed by a preliminary design of the selected measurement method. Transient thermal conduction effects were identified as important; a preliminary finite-element conduction model quantified the errors expected by neglecting conduction. A compensation method was developed to account for effects of conduction and convection. This method was verified in analog electrical simulations, and used to compensate dynamic temperature data from a laboratory combustor and a gas turbine engine. Detailed data compensations are presented. Analysis of error sources in the method were done to derive confidence levels for the compensated data.

Elmore, D. L.↗

Validation of Temperature Measurements from the Airborne Raman Ozone Temperature and Aerosol Lidar During SOLVE

The Airborne Raman Ozone, Temperature and Aerosol Lidar (AROTEL) participated in the recent Sage III Ozone Loss and Validation Experiment (SOLVE) by providing profiles of aerosols, polar stratospheric clouds (PSCs), ozone and temperature with high vertical and horizontal resolution. Temperatures were derived from just above the aircraft to approximately 60 kilometers geometric altitude with a reported vertical resolution of between 0.5 and 1.5 km. The horizontal footprint varied from 4 to 70 km. This paper explores the measurement uncertainties associated with the temperature retrievals and makes comparisons with independent, coincident, measurements of temperature. Measurement uncertainties range from 0.1 K to approximately 4 K depending on altitude and integration time. Comparisons between AROTEL and balloon sonde temperatures retrieved under clear sky conditions using both Rayleigh and Raman scattered data showed AROTEL approximately 1 K colder than sonde values. Comparisons between AROTEL and the Meteorological Measurement System (MMS) on NASA's ER-2 show AROTEL being from 2-3 K colder for altitudes ranging from 14 to 18 km. Temperature comparisons between AROTEL and the United Kingdom Meteorological Office's model showed differences of approximately 1 K below approximately 25 km and a very strong cold bias of approximately 12 K at altitudes between 30 and 35 km.

Burris, John↗

Depth-Penetrating Temperature Measurements of Thermal Barrier Coatings Incorporating Thermographic Phosphors

Thermographic phosphors have been previously demonstrated to provide effective non-contact, emissivity-independent surface temperature measurements. Because of the translucent nature of thermal barrier coatings (TBCs), thermographic phosphor-based temperature measurements can be extended beyond the surface to provide depth-selective temperature measurements by incorporating the thermographic phosphor layer at the depth where the temperature measurement is desired. In this paper, thermographic phosphor (Y2O3:Eu) fluorescence decay time measurements are demonstrated to provide through-the-coating thickness temperature readings up to 1100 C with the phosphor layer residing beneath a 100 micron thick TBC (plasma-sprayed 8wt% yttria-stabilized zirconia). With an appropriately chosen excitation wavelength and detection configuration, it is shown that sufficient phosphor emission is generated to provide effective temperature measurements, despite the attenuation of both the excitation and emission intensities by the overlying TBC. This depth-penetrating temperature measurement capability should prove particularly useful for TBC diagnostics where a large thermal gradient is typically present across the TBC thickness. The fluorescence decay from the Y2O3:Eu layer exhibited both an initial short-term exponential rise and a longer-term exponential decay. The rise time constant was demonstrated to provide better temperature indication below 500 C while the decay time constant was a better indicator at higher temperatures.

Eldridge, Jeffrey I.↗

Error in temperature measurements due to conduction along the sensors

When a sensor is embedded in a solid body to measure its internal temperature, any conduction to or from its sensing element may cause the indicated temperature to be different from the true temperature. This paper describes an analysis of the error caused by conduction when there is an arbitrary temperature distribution in the body along the sensor. The sensor is modeled as a cylindrical fin and the appropriate conduction equation is solved. The solution gives a correction for the error which depends on such parameters as, depth of immersion, thermocouple wire and insulation properties, contact between the sensor and the body, and temperature distribution in the body. The latter may not be known, but the measured temperature distribution can be used as a first approximation. The corrected value can then be used to obtain a better estimate of the error. The results show good agreement with experimental observations.

Singh, B. S.↗

Evaluating capacity fade in dual insertion batteries using potential and temperature measurements

Methods and systems are described of managing a battery system. The battery system including at least one battery cell and one or more sensors configured to measure a temperature of the at least one battery cell. The method includes receiving a measurement of the temperature of the at least one battery cell, estimating an open circuit potential of the at least one battery cell, estimating a capacity fade of the at least one battery cell based on the open circuit potential of the at least one battery cell and a ratio of a change in the open circuit potential relative to a change in the temperature of the at least one battery cell, and regulating at least one of charging or discharging of the at least one battery cell based on the estimation of the capacity fade.

Christensen, John F.↗

Proceedings of the Second Noncontact Temperature Measurement Workshop

The state of the art in noncontact temperature measurement (NCTM) technology was reviewed and the NCTM requirements of microgravity materials processing community identified. The workshop included technical presentations and discussions which ranged from research on advanced concepts for temperature measurement to laboratory research and development regarding measurement principles and state-of-the-art engineering practices for NCTM methodology in commercial and industrial applications. Technical presentations were made concerning: NCTM needs as perceived by several NASA centers, recent ground-based NCT, research and development of industry, NASA, academia, and selected national laboratories, work-in-progress communication, and technical issues of the implementation of temperature measurement in the space environment to facilitate future U.S. materials science investigations.

Hale, Robert R.↗