Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Temperature control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Monitoring of Liquid Metal Reactor Heater Zones with Recurrent Neural Network Learning of Temperature Time Series

Advanced high-temperature fluid reactors (ARs), such as sodium fast reactors (SFRs) and molten salt cooled reactors (MSCRs) utilize high-temperature fluids at ambient pressure. To melt the fluid during reactor startup and prevent fluid freezing during cooldown, the thermal–hydraulic systems of such ARs include heater zones consisting of specific heaters with controllers, temperature sensors, and thermal insulation. The failure of heater zones due to insulation material degradation or improper installation, resulting in parasitic heat losses, can lead to fluid freezing. The detection of faults using a heat-transfer model is difficult because of a lack of knowledge of the experimental details. Data-driven machine learning of heater zone temperature time series offers a viable alternative. In this study, we benchmarked the performance of recurrent neural networks (RNNs) in an analysis of heat-up transient temperature time series of heater zones installed on a liquid sodium vessel. The RNN models include long short-term memory (LSTM) and gated recurrent unit (GRU) networks, as well as their bi-directional variants, BiLSTM and BiGRU. Anomalous temperature points were designated using a percentile-based threshold applied to residual fluctuations in the detrended temperature time series. Additionally, the impact of the exponentially weighted moving average (EWMA) method on detection accuracy was examined. The RNN models’ performance was assessed using precision, recall, and F 1 score metrics. Results demonstrated that RNN models effectively detect anomalies in temperature time series with the best models for each heater zone achieving F 1 scores of over 93%. To explain the variations in RNN model performance across different heater zones, we used Kullback–Leibler (KL) divergence to quantify the relative entropy between training and testing data, and the Detrended Fluctuation Analysis (DFA) to assess long-range temporal correlations. For datasets with strong long-range correlations and minimal relative entropy between training and testing data, GRU is the best-performing model. When the data exhibits weaker long-term correlations and a significant relative entropy between training and testing distributions, BiGRU shows the best performance. For the data sets with intermediate values of both KL divergence and DFA, the best performance is obtained with LSTM and BiLSTM, respectively.

gated recurrent unit

Investigating Radiation-Induced Actinide Species in Solution

Our fundamental understanding of actinide radiation-induced redox chemistry is crucial to nuclear fuel cycle development, due to the unavoidable exposure of these elements to ionizing radiation fields, both inherent and from in-process applications. Plutonium (Pu) and americium (Am) both possess multiple oxidation states, the careful manipulation of which are essential in the study and utilization of their rich chemistry, developing new nuclear technologies, and securing the long-term sustainability of nuclear power. However, knowledge in this area is far from complete. Consequently, we have studied the radiation-induced chemistry of both Pu and Am through a variety of techniques. Temperature-controlled electron pulse radiolysis has been used to study Am for the first time, determining the feasibility of Am redox reactions under used nuclear fuel reprocessing conditions, (e.g. nitric acid, non-ambient temperature). Additionally, we have developed an experimentally evaluated multi-scale computer model for the prediction of gamma radiation-induced Pu redox chemistry due to radiolysis and disproportionation reactions in concentrated nitric acid solutions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

Investigating Radiation-Induced Actinide Species in Solution

Our fundamental understanding of actinide radiation-induced redox chemistry is crucial due to their unavoidable exposure to ionizing radiation fields, both inherent and from in-process applications. Plutonium (Pu) and americium (Am) both possess multiple oxidation states, the careful manipulation of which are essential in the study and utilization of their rich chemistry, developing new nuclear technologies, and securing the long-term sustainability of nuclear power. However, knowledge in this area is far from complete. Consequently, we have studied the radiation-induced chemistry of both Pu and Am through a variety of techniques. Temperature-controlled electron pulse radiolysis has been used to study Am for the first time, determining the feasibility of Am redox reactions under used nuclear fuel reprocessing conditions, (e.g. nitric acid, non-ambient temperature). Additionally, we developed an experimentally evaluated multi-scale computer model for the prediction of gamma radiation-induced Pu redox chemistry due to radiolysis and disproportionation reactions in concentrated nitric acid solutions.

actinide

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE

Disassembly and Initial Post-Irradiation Examination of the Mini99 Experiment

The Miniature Fuel Molybdenum-99 (Mini99) experiment is a first-of-a-kind experiment in the High Flux Isotope Reactor. Mini99 is the first MiniFuel irradiation experiment to use liquid metal inside the MiniFuel subcapsule for additional temperature control. In this work, the initial post-irradiation examination is reported. As-built simulations were conducted and compared with designs, and physical post-irradiation examinations were conducted to determine actual test temperatures via SiC thermometry samples, to evaluate the extent of fission gas release from the samples, and to remove the fuel from the subcapsules. As-built simulations compared well with experiment designs and were in reasonable agreement with the measured temperatures inferred from the passive SiC thermometers. Additionally, fission gas release values were relatively small (on the order of 3%); one sample reached approximately 8%. Although some of this behavior is attributable to recoil, most of the gas release was likely caused by the physics of the fuel behavior during the test. Finally, disassembly showed that at least four of the fuel samples degraded into small components and granules at some point during the test, with the state of the other two samples unproven. Additional work is planned for further examination of these samples via various microscopy techniques.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

A tunable autonomous RNA-fueled micro-engine

Autonomous molecular machines capable of converting chemical energy into mechanical motion are foundational components for synthetic nanoscale systems. Inspired by biological motors, we report the construction of a tunable, RNA-fueled DNA origami engine that drives the cyclic movement of a 500 nm-diameter particle at the microscale. The engine operates via sequential RNA–DNA hybridization and enzymatic cleavage by RNase H, enabling reversible switching between folded and unfolded conformations without external intervention. By modulating RNA and enzyme concentrations and controlling temperature, we achieve tunable switching kinetics, with transition periods as short as ~10 s. Kinetic modeling reveals that the folding pathway is governed by both productive RNA binding and the enzymatic clearance of misfolded intermediates, while unfolding is primarily controlled by RNase H activity. Since the RNA fuel binds specifically to the DNA strands, each engine is addressable simply by changing the sequences. This work demonstrates a programmable, self-resetting molecular actuator and offers a blueprint for building more complex nanomechanical systems with forces and energies comparable to molecular motors.

DNA nanomachines

Integration of pH Control into Chi.Bio Reactors and Demonstration with Small-Scale Enzymatic Poly(ethylene terephthalate) Hydrolysis

Small-scale bioreactors that are affordable and accessible would be of major benefit to the research community. In previous work, an open-source, automated bioreactor system was designed to operate up to the 30 mL scale with online optical monitoring, stirring, and temperature control, and this system, dubbed Chi.Bio, is now commercially available at a cost that is typically 1–2 orders of magnitude less than commercial bioreactors. In this work, we further expand the capabilities of the Chi.Bio system by enabling continuous pH monitoring and control through hardware and software modifications. For hardware modifications, we sourced low-cost, commercial pH circuits and made straightforward modifications to the Chi.Bio head plate to enable continuous pH monitoring. For software integration, we introduced closed-loop feedback control of the pH measured inside the Chi.Bio reactors and integrated a pH-control module into the existing Chi.Bio user interface. We demonstrated the utility of pH control through the small-scale depolymerization of the synthetic polyester, poly(ethylene terephthalate) (PET), using a benchmark cutinase enzyme, and compared this to 250 mL bioreactor hydrolysis reactions. The results in terms of PET conversion and rate, measured both by base addition and product release profiles, are statistically equivalent, with the Chi.Bio system allowing for a 20-fold reduction of purified enzyme required relative to the 250 mL bioreactor setup. Through inexpensive modifications, the ability to conduct pH control in Chi.Bio reactors widens the potential slate of biochemical reactions and biological cultivations for study in this system, and may also be adapted for use in other bioreactor platforms.

09 BIOMASS FUELS

Master Oscillator and Phase Reference Line Design for the PIP-II Linac

The phase averaging reference line system provides the RF phase reference, LO and clock signals to the LLRF and other accelerator sub-systems. The PIP-II linac has RF systems at three frequencies - 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase-noise oscillator is used as the master oscillator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each frequency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, A. [Fermilab]

Fermilab PIP-II Master Oscillator and Precision Reference Line Design and Construction

The phase averaging reference line system pro- vides the RF phase reference, LO and clock sig- nals to the LLRF and other accelerator sub- systems. The PIP-II linac has RF systems at three frequencies – 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase- noise oscillator is used as the master oscil- lator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each fre- quency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, Ahmed [Fermilab]

Thermal Studies of CMS High-Granularity Calorimeter (HGCAL) Cassettes for the HL-LHC Upgrade

The CMS High Granularity Calorimeter (HGCAL) is a key endcap upgrade for the High-Luminosity LHC, designed to operate in an environment of extreme radiation and high particle rates. Each HGCAL cassette integrates silicon and scintillator modules, front-end ASICs, and a copper cooling plate that provides both mechanical integrity and thermal coupling using two-phase CO₂ cooling. Stable and uniform temperature control is essential to ensure reliable performance of the front-end electronics and to limit radiation-induced leakage currents in the silicon sensors. We present results from thermal characterization studies of pre-series HGCAL cassettes assembled and tested at Fermilab. Embedded RTD/PT1000 temperature sensors were used to measure gradients across copper cooling plates, module layers, and cassette edges under powering conditions representative of operation. The measured thermal behavior demonstrates effective heat transport through the cassette stack and highlights small but systematic variations correlated with geometry and assembly tolerances. These results validate the cooling performance of HGCAL cassettes.

Wang, Jinglu [Northwestern U.]

Ex-situ Heat Treatment of TEM Foils in a Custom Titanium Fixture: A Case Study on Ni-based Superalloy

The advancement of microstructural characterization at the nanoscale is critical to understanding the microstructural evolution and performance of engineering materials. Transmission electron microscopy (TEM) plays a vital role in such investigations, particularly when coupled with controlled ex- and in-situ experiments. In this study, we introduce a novel method for ex-situ heat treatment (HT) of TEM foils using a custom-designed fixture, made from pure titanium, and vacuum furnace to inhibit oxidation. This approach ensures precise temperature control and minimal sample contamination during HT, critical for substructural characterization and analysis of metallic materials. The fixture consists of a titanium base with three slits, for three sample foils, and a titanium cap for closure. The entire assembly is placed in a vacuum heat treatment furnace with high vacuum capability to prevent oxidation. To validate the effectiveness of the setup, precipitation behavior and microstructural changes were studied in an IN725 variant heat-treated at 500°C for 1 hour and 282 variant heat-treated at 700°C for 1 hour, as case studies.

electron microscopy

Explainable discrepancy checker and diagnosis for digital Twin-based supervisory control system

By virtually representing a physical object and process, a digital twin (DT) enables optimal autonomous operations by combining classical and novel frameworks in sensors, state predictions, and multi-input/multi-output systems. A DT’s values depend on how well models estimate quantities of interest and on how uncertainty is handled. Moreover, DTs often combine physics-based and data-driven models with mixed fidelities, where classical uncertainty quantification (UQ) struggles with many sources of uncertainty and real-time constraints. Here, this work presents a UQ-based discrepancy checking and diagnosis tool for a DT-based supervisory control system. The tool is developed using metadata from an automated DT development process to learn correlations between sources of uncertainties and outcomes. During operation, it compares predictions with measurements, attributes discrepancies to dominant sources, and recommends parameter and configuration updates. We verify the workflow on a synthetic temperature-control problem and deploy it on a virtual Thermal Energy Delivery System, reducing mismatch and improving control robustness.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Coercivity enhancement in hematite/permalloy heterostructures across the Morin transition

Interfacial effects between antiferromagnetic (AFM) and ferromagnetic (FM) materials have long been a center of magnetism studies. Aside from the exchange bias occurring at the AFM/FM interface, controlling the coercivity is another significant topic in magnetic recordings. The coercivity of FM materials is often determined through varying grain size, alloy composition, density of defects, etc., which is set during material growth and offers limited room for modification after growth. Hematite (α - Fe 2 O 3 ) is an AFM material that undergoes a temperature-controlled spin-flip transition, the so-called Morin transition. This transition gives an extra degree of freedom making hematite an intriguing component to study the exchange coupling when interfaced with an FM material. Here, in this work, changes in the magnetic properties of soft magnetic permalloy (Ni 81 Fe 19 , or Py) thin films grown on hematite were studied across the Morin transition. Surprisingly, these samples showed a remarkable change in coercivity during the Morin transition. We attribute this effect to the magnetic domain mixture of hematite during the Morin transition. Our findings present a novel method of controlling the coercivity of plain ferromagnetic thin films.

Antiferromagnet

Understanding the temperature and humidity dependence of the SiPM characteristics

A miniature version of the ICAL experiment at the India-based Neutrino Observatory, the mini-ICALis in operation at the IICHEP, Madurai. The commissioning work of a Cosmic Muon Veto detector (CMVD)on top of the mini-ICAL is continued using extruded plastic scintillators with embeddedWLS fibers and the SiPM as a photo-transducer. The CMVD is being built to study thefeasibility of a cosmic muon veto for a shallow-depth neutrino experiment. The SiPM is calibratedusing an ultrafast LED driver andthe same calibration techniques will be used during the data taking period with a simplified LED in thesame readout PCB. An experimental setup wasdesigned to characterise the SiPMs in a temperature controlled environment. The readout electronicsinvolves trans-impedance amplifiers and a voltage followers of combined gain 1.24 mV/$\mu$A and adigital storage oscilloscope for the data collection with a minimal distortion of SiPM signal.Various characteristics of the Hamamatsu SiPM (S13360-2050VE), e.g. signal shape, optically correlatedand uncorrelated noise, recovery time etc were studied as a function of $V_{ov}$, number of photoelectrons,the ambient temperature and the humidity. This paper will cover the details of those results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The human plasma lipidome response to exertional heat tolerance testing

The year of 2023 displayed the highest average global temperatures recorded in history— the duration and severity of extreme heat are projected to increase. Rising global temperatures represent a major public health threat, especially to occupations exposed to hot environments, such as construction and agricultural workers, and first responders. Despite efforts of the scientific community, there is still a need to characterize the pathophysiological processes leading to heat related illness and develop biomarkers that can predict its onset. Here, we performed a plasma lipidomic analysis on male and female subjects who underwent heat tolerance testing (HTT), consisting of a 2-h treadmill walk at 5 km/h with 2% inclination at a controlled temperature of 40oC. We identified 995 lipids from 27 classes, with nearly half of all detected lipids being responsive to HTT. Lipid classes related to substrate utilization were predominantly affected by HTT, with a downregulation of triacylglycerols and upregulation of free fatty acids and acyl-carnitines. We additionally examined correlations between changes in plasma lipids by using the even chain acyl-carnitines is physiological strain index (PSI). Here, even chain acyl-carnitines, bi-products of incomplete beta oxidation, and diacylglycerols displayed the highest correlation to PSI. PSI did not correlate with plasma lactate levels, which suggests that correlations with related to metabolic efficiency versus physical exertion. Overall, our results show that HTT has a strong impact on the plasma lipidome and that incomplete beta oxidation may underlie heat intolerance.

60 APPLIED LIFE SCIENCES

Quasi-elastic neutron scattering study on dynamically asymmetric polymer blends

Compatibility between polymers with different glass transition temperatures controls the thermomechanical properties of blends. This work explores the segmental dynamics of poly(methyl acrylate) (PMA) chains when they are blended with polymers of different rigidities and miscibility. Inspired by the intriguing dynamic asymmetry of chains within the interfacial layer of nanoparticles, this study aims to understand dynamic heterogeneity in dynamically asymmetric blends of PMA/poly(methyl methacrylate) (PMMA), PMA/polystyrene (PS), and PMA/poly(ethylene oxide) (PEO) using the differential scanning calorimetry (DSC) and quasi-elastic neutron scattering (QENS) measurements below and above the glass transition temperature of PMMA or PS. Further, results revealed that the segmental jump distance of PMA increased on blending due to volume enhancement. The reduced effective diffusivity of PMA in PMMA is attributed to PMMA's enhanced flexibility (lower characteristic ratio, C ∞ ) and superior interaction (lower ) when compared with the PS environment. The results demonstrate that the chain rigidity and miscibility affect the free volume, interchain cooperativity, and segmental dynamics in dynamically asymmetric blends.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Modeling of the metal–insulator transition temperature in alio-valently doped VO 2 through symbolic regression

The correlated semiconductor vanadium dioxide (VO 2 ) exhibits an insulator–metal transition (IMT) near room temperature, which is of interest in various device applications. Precise IMT temperature control is crucial to determine the use cases across technologies such as thermochromic windows, actuators for robots or neuronal oscillators. Doping the cation or anion sites can modulate the IMT by several tens of degrees and control hysteresis. However, modeling the effects of control parameters (e.g., doping concentration, type of dopants) is challenging due to complex experimental procedures and limited data, hindering the use of traditional data-driven machine learning approaches. Symbolic regression (SR) can bridge this gap by identifying nonlinear expressions connecting key input parameters to target properties, even with small data sets. In this work, we develop SR models to capture the IMT trends in VO 2 influenced by different dopant parameters. Using experimental data from the literature, our study reveals a dual nature of the IMT temperature with varying tungsten (W) doping concentrations. The symbolic model captures data trends and accounts for experimental variability, providing a complementary approach to first-principles calculations. Our feature-driven analysis across a broader class of dopants informs selectivity and provides qualitative insights into tuning phase transition properties valuable for neuromorphic computing and thermochromic windows.

36 MATERIALS SCIENCE