Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tank Chilldown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

44 records · Page 3

Shuttle LOX loading transient study. Task 2 milestone report. National space and technology laboratories (NSTL) LOX loading facility analysis

Transient thermodynamic analyses were made of the LOX loading system proposed for the space shuttle main propulsion test article (MPTA). This system is made up of a LOX replenish system and a main LOX line which include the barge tank, the lines, pumps, and valves between the barge and the orbiter (ORB) ground service equipment (GSE) interface, the MPTA fill system, the space shuttle main engine (SSME) chilldown bleed system, and the GSE vent system. System analyses include predictions of system performance sensitivity to operating sequence and LOX flowrate, temperature, and quality at the ORB/GSE interface. The transient thermodynamic conditions at the SSME feed line entrance, ET entrance (tank bottom), and the SSME bleed/GSE vent TEE are also included. The analyses are based on continuous SSME bleed flow during GSE facility chilldown.

Glasgow, V. L.↗

CFD Modeling of Cryogenic Chilldown in a Complex Channel under Normal and Low Gravity Conditions

Future NASA architectures have baselined cryogenic propulsion systems as well as cryogenic fluid management to support lunar missions and ultimately to support future missions to Mars. These missions will require chilling hardware down prior to engine restart as well as chilling lines and tanks prior to transferring and refueling these propulsion elements in orbit. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these chilldown processes can be used to reduce system and propellant mass as well as mission risk.

CFD↗

CFD Modeling of Cryogenic Chilldown in a Complex Channel under Normal and Low Gravity Conditions

Future NASA architectures have baselined cryogenic propulsion systems as well as cryogenic fluid management to support lunar missions and ultimately to support future missions to Mars. These missions will require chilling hardware down prior to engine restart as well as chilling lines and tanks prior to transferring and refueling these propulsion elements in orbit. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these chilldown processes can be used to reduce system and propellant mass as well as mission risk. To gain confidence in these computational models, appropriate anchoring and validation to experimental data in a relevant environment needs to be performed. Recent ground and sub-orbital flight experiments conducted by the Japan Aerospace Exploration Agency (JAXA) investigated chilldown of a complex channel resembling a turbopump bearing cavity at low flow rates. This work presents Computational Fluid Dynamics (CFD) model development of the chilldown experiment employing two-phase flow boiling models available in commercial CFD software STAR-CCM+ using Volume of Fluid (VOF) and the traditional Euler-Euler multiphase flow solvers. Comparisons of the numerical and experimental results under normal and low-gravity conditions are presented. An assessment of solid wall temperatures and phase distribution yielded important insights into multiphase solver choice, dependence on gravity environment, and challenges associated with cryogenic flow boiling prediction and validation.

CFD↗

CRYogenic Orbital TEstbed Ground Test Article Thermal Analysis

The purpose of this study was to anchor thermal and fluid system models to CRYOTE ground test data. The CRYOTE ground test artide was jointly developed by Innovative Engineering Solutions, United Launch Alliance and NASA KSC. The test article was constructed out of a titanium alloy tank, Sapphire 77 composite skin (similar to G10), an external secondary payload adapter ring, thermal vent system, multi layer insulation and various data acquisition instrumentation. In efforts to understand heat loads throughout this system, the GTA (filled with liquid nitrogen for safety purposes) was subjected to a series of tests in a vacuum chamber at Marshall Space Flight Center. By anchoring analytical models against test data, higher fidelity thermal environment predictions can be made for future flight articles which would eventually demonstrate critical cryogenic fluid management technologies such as system chilldown, transfer, pressure control and long term storage. Significant factors that influenced heat loads included radiative environments, multi-layer insulation performance, tank fill levels and pressures and even contact conductance coefficients. This report demonstrates how analytical thermal/fluid networks were established and includes supporting rationale for specific thermal responses.

Piryk, David↗

Propellant management report for the Titan Centaur TC-5 extended mission

An extended mission was conducted to perform experiments demonstrating increased operational capabilities. The Centaur propellant behavior, the effects of reduced tank pressurization levels, and a propellant duct prechill technique were successfully evaluated. The major flight data results show that: (1) the propellants can be controlled with short collection times, even with a simulated H202 engine failure; (2) extensive tank ventings can be safely performed; (3) the Centaur boost pumps can perform adequately with no LH2 tank pressurization, and with low LO2 tank pressurization levels; (4) the duct prechill technique is an effective way to reduce boost pump cavitation and improve engine chilldown; and (5) the Centaur boost pumps should be completely stopped prior to an engine start sequence.

Lacovic, R.↗

Two-Phase Convection Heat Transfer Correlations for Liquid Hydrogen Pipe Chilldown

Recently, heat transfer correlations based on liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching data were developed to improve the predictive accuracy of lumped node codes like SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP). After implementing these correlations into both programs, updated model runs showed strong improvement in LN2 pipe chilldown modeling but only modest improvement in LH2 modeling. Due to large differences in thermal and fluid properties between the two fluids, results indicated a need to develop a separate set of LH2-only correlations to improve the accuracy of the simulations. This paper presents a new set of two-phase convection heat transfer correlations based on LH2 pipe quenching data. A correlation to predict the bulk vapor temperature was developed after analysis showed that high amounts of thermal nonequilibrium of the liquid and vapor phases occurred during film boiling of LH2. Implemented in a numerical model, the new correlations achieve a mean absolute error of 19.5 K in the predicted wall temperature when compared to recent LH2 pipe chilldown data, an improvement of 40% over recent GFSSP predictions. This correlation set can be implemented in simulations of the transient LH2 chilldown process. Such simulations are useful for predicting the chilldown time and boil-off mass of LH2 for applications such as the transfer of LH2 from a ground storage tank to the rocket vehicle propellant tank, or through a rocket engine feedline during engine startup.

critical heat flux↗

Preflight status of the External Tank portion of the Space Shuttle Main Propulsion System

The development progress of the External Tank (ET) of the Shuttle Main Propulsion System (MPS) is described. 87% of ET propulsion components have satisfactorily completed qualification tests in preparation for the first Shuttle flight and their performance has been verified in the Main Propulsion Test Article (MPTA) firings of up to 100 seconds duration. The design changes in the LH2 tank pressurant diffuser, the LO2 feed system, and the ground test LO2 tank are discussed. Propellant loading information from MPTA tests may be used to predict loading operations and performance at KSC and VAFB, while ullage pressure profiles and boil-off rates during loading, chilldown rates, and final bulk density data have been obtained with geyser suppression evaluated and loading procedures established and verified. The MPTA test experience provided data to evaluate pressurization system and ET to Orbiter interface propellant performance noting thus that the fluid interface requirements will be satisfied for the first Shuttle flight. The Intertank inerting system was found to be effective in minimizing hazardous gas mixtures and full scale separation tests of the ET to Ground Umbilical Carrier Plate system were successfully completed.

Norquist, L.↗

OTV orbital tanking systems

Orbital transfer of cryogenic propellants could benefit spacecraft and Orbital Transfer Vehicle (OTV) missions in the 1980s by supplying main propulsion, attitude control, or other fluid systems. The Space Shuttle can operate as a tanker when equipped with cryogenic propellant storage and orbital transfer systems. The key technologies are multilayer insulation, capillary propellant acquisition, zero-g gaging, orbital chilldown, and possibly large flight weight dewars. The technologies and operations could be realistically demonstrated using a Centaur that has been integrated with the Shuttle. Orbital refueling capability can enhance the usefulness of the whole Shuttle program

Heald, D. A.↗