Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tank 50”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Control Selection for the Neutralization Tank in the Aqueous Recovery System at the Savannah River Plutonium Processing Facility

The Aqueous Recovery System (ARS) at the Savannah River Plutonium Processing Facility (SRPPF) recovers and purifies plutonium (Pu) using aqueous chemistry techniques. The neutralization tanks in the ARS collect waste streams with various impurities and greatly reduced concentrations of Pu than are produced during aqueous processing. Criticality safety is primarily achieved in the ARS by using geometrically favorable process vessels. However, due to the geometry of neutralization tanks, each tank is administratively limited to no more than 450 g Pu, thus representing the transition from geometry to mass control. To ensure that this mass limit is not exceeded, an administrative control requires taking two samples of any solution to be sent to a neutralization tank. Normal operations are expected to result in less than 50 g Pu in a neutralization tank filled to its capacity of 250 L. Process upsets may cause an inadvertent transfer of up to 1000 g Pu to a neutralization tank, producing a system that is potentially not subcritical for all possible configurations of the tank. To ensure that a neutralization tank remains safety subcritical, passive engineered controls (e.g. changing tank geometry or adding fixed poisons), active engineered controls (e.g. interlocks), and administrative controls (e.g. soluble poisons and valve isolation) were considered and their viability evaluated. Ultimately, the team chose an administrative, dual-valve isolation strategy. This paper will thoroughly discuss the various control strategy options and why many of the options were not feasible for maintaining criticality safety.

Dressman, Phillip M. [Savannah River Nuclear Solut↗

Control Selection for the Neutralization Tank in the Aqueous Recovery System at the Savannah River Plutonium Processing Facility

The Aqueous Recovery System (ARS) at the Savannah River Plutonium Processing Facility (SRPPF) recovers and purifies plutonium (Pu) using aqueous chemistry techniques. The neutralization tanks in the ARS collect the waste streams, containing various impurities and greatly reduced concentrations of Pu, that are produced during aqueous processing. Criticality safety is primarily achieved in the ARS by using geometrically favorable process vessels. However, due to the geometry of neutralization tanks, each tank is administratively limited to no more than 450 g Pu, thus representing the transition from geometry to mass control. To ensure that this mass limit is not exceeded, an administrative control requires taking two samples of any solution to be sent to a neutralization tank. Normal operations are expected to result in less than 50 g Pu in a neutralization tank filled to its capacity of 250 L. Process upsets may cause an inadvertent transfer of up to 1000 g Pu to a neutralization tank, producing a system that is potentially not subcritical for all possible configurations of the tank. To ensure that a neutralization tank remains safety subcritical, passive engineered controls (e.g.changing tank geometry or adding fixed poisons), active engineered controls (e.g. interlocks), and administrative controls (e.g. soluble poisons and valve isolation) were considered and their viability evaluated. Ultimately, the team chose an administrative, dual-valve isolation strategy. This paper will thoroughly discuss the various control strategy options and why many of the options were not feasible for maintaining criticality safety.

Dressman, Phillip M. [Savannah River Nuclear Solut↗

Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks

Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. Finally, this paper is focused on establishing the significance of the convection numbers in conjunction with the Reynolds number for modeling the thermal stratification in storage tanks.

14 SOLAR ENERGY↗

Genetics of Flooding Tolerance in an F 2 Miscanthus sacchariflorus ssp. lutarioriparius × M. sinensis Population

Miscanthus is a warm-season, perennial grass cultivated as a feedstock for bioenergy and bioproducts. M. sacchariflorus ssp. lutarioriparius has high yield potential and is well-adapted to seasonal flooding, but little is known about the genetics of this adaptation. We conducted a quantitative trait locus (QTL) analysis on a population of 332 diploid Miscanthus ×giganteus (Mxg) F2s derived from an initial cross between diploid M. sacchariflorus ssp. lutarioriparius ‘PF30022’ and diploid M. sinensis ‘PMS-014’, followed by intermating 50 F 1 s. Using tanks in a greenhouse to assess the effects of partial submergence on actively growing plants, we compared an aerobic soil control to a 6-week flood treatment. The study's primary objectives were to (1) identify QTL for flooding tolerance in Miscanthus , (2) identify candidate genes and (3) compare ethylene response factors in Miscanthus with those in rice and Arabidopsis , sorghum and maize for binding site sequence homology and synteny, especially those associated with flooding tolerance. In total, 10 QTL and 66 candidate genes for partial submergence tolerance were identified (including many for ethylene signalling), a first report for Miscanthus . Notably, none of the Miscanthus candidates were orthologs of rice Sub1A, SK1 or SK2 , yet the ‘PF30022’ parent exhibited a snorkeling phenotype, indicating convergent evolution. This study will facilitate breeding of climate-resiliant Mxg.

abiotic stress tolerance↗

Additively Manufactured, Lightweight, Low-Cost Composite Vessels for Compressed Natural Gas Fuel Storage

This project will develop a process to combine AM via direct ink writing (DIW) technology for CFC printing and to use design optimization tools pioneered at LLNL, with advances in resin/composite formulation enabled by chemical and nano-material modification to produce lightweight low-cost CNG tanks. Our approach will yield sub-scale prototype composite pressure tanks equivalent to Type-5 CNG vessel designs that demonstrate a potential cost-benefit advantage. Central to our vision is using agile AM and design based on computationally informed DIW of both short and continuous CF, further coupled with high-performance thermoset polymer matrixes modified by emergent nanomaterials. Our single-stage, multi-material AM technology, combined with a decreased volume fraction of CF and an increased proportion of economically advantaged short fiber, all together drive the reduction in manufacturing time and overall cost. Importantly, reductions in continuous fiber and overall fiber volume fraction will be achieved without detriment to the mechanical strength of the composite vessel. This will be achieved by employing a single process using multi materials grading involving a thermoset resin “ink” modified with aligned nanoplatelets to leverage the efficient tortuous-path gas barrier effect, printed as an inner flexible gas barrier as the initial stage in our manufacturing process before compositionally grading the AM feedstock in real-time to transition to a rigid, structural CF-filled resin. The proposed hybrid construction is projected to achieve pressure ratings at a service range of 2,900–3,600 psi with a 3× burst safety factor comparable to conventional filament-wound composite tanks with an estimated 30–50% reduction in total manufacturing cost.

03 NATURAL GAS↗

Experimental performance analysis of a dual source heat pump integrated with thermal energy storage

To mitigate disturbances to the electric grid resulting from the growing penetration of intermittent and decentralized renewable generation, a dual-source (air source and ground source) heat pump (DSHP) integrated with thermal energy storage (TES) was developed. The DSHP can use either ambient air or the shallow subsurface of the ground to provide space heating or space cooling to the building as the conventional heat pump and produce hot/cold water for charging TES. Using dual sources (air and ground) can reduce the required size of the expensive ground heat exchangers while retaining high energy efficiency. During the off-peak period, the DSHP cools/heats the TES with low-cost electricity or overproduced renewable power. The stored cooling/heating energy in the TES is released during peak hours of the electric grid to meet the thermal demands of the building without consuming electricity to run the DSHP. A 2-ton (7 kW) prototype DSHP was developed and integrated with a 50-gallon (189 L) TES tank filled with a phase change material. Field tests were conducted to characterize the performance of the integrated system operating in various operation modes.

Wang, Lingshi↗

Genomics Characterization of an Engineered Corynebacterium glutamicum in Bioreactor Cultivation Under Ionic Liquid Stress

Corynebacterium glutamicum is an ideal microbial chassis for production of valuable bioproducts including amino acids and next generation biofuels. Here we resequence engineered isopentenol (IP) producing C. glutamicum BRC-JBEI 1.1.2 strain and assess differential transcriptional profiles using RNA sequencing under industrially relevant conditions including scale transition and compare the presence vs absence of an ionic liquid, cholinium lysinate ([Ch][Lys]). Analysis of the scale transition from shake flask to bioreactor with transcriptomics identified a distinct pattern of metabolic and regulatory responses needed for growth in this industrial format. These differential changes in gene expression corroborate altered accumulation of organic acids and bioproducts, including succinate, acetate, and acetoin that occur when cells are grown in the presence of 50 mM [Ch][Lys] in the stirred-tank reactor. This new genome assembly and differential expression analysis of cells grown in a stirred tank bioreactor clarify the cell response of an C. glutamicum strain engineered to produce IP.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient and Reliable Power Takeoff for Ocean Wave Energy Harvesting

The project goal is to significantly improve the current ocean wave energy harvesting through innovative Power Take-off (PTO) design, advanced power electronics, and novel wave capture structures. The objective of the project is to design and demonstrate system-agnostic components for application across multiple MHK systems, and complete component designs, build scaled prototypes, and perform testing and analysis for metric validation of 25% increase in component rating/per unit cost and 50% reduction in failure rate. The major innovation of the PTO is the Mechanical Motion Rectifier (MMR) mechanism that rectifies the bi-directional oscillatory motion of the input from waves into a steady unidirectional rotation output to directly drive the electrical generator. Through this mechanism, the efficiency and the fatigue life of the PTO can be significantly improved to benefit the energy absorption and lifespan of the wave energy converters (WEC). During the period of performance, the component and system design are completed, the scaled prototypes are developed and performed testing. It is validated that the 25% increase in a component rating/per unit cost. The 50% reduction in failure rate is not directly validated by experiments, however, it can be explained qualitatively with analysis. Besides, 8 journal articles, 13 conference proceedings, 1 patent, 3 Master thesis and two Ph.D. dissertations are published based on the work related to this project. The list of all the publications can be found at the end of the project as an appendix. Over 30 students and postdocs were trained through this project. Three prototypes of 100W and 500W WECs and 10KW PTO were designed, built, and tested in ocean wave tank and using the NREL dynamometer. This project demonstrated 50-80% PTO efficiency, 90-98% power electronics efficiency, up to 66% capture width ratio in irregular waves, and 34% overall efficiency in regular waves.

16 TIDAL AND WAVE POWER↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

Wave Tank Testing Report for Controls Validation of a Heaving Point Absorber

The core objectives of this project is to improve the power capture of three different wave energy conversion (WEC) devices by more than 50% using an advanced control system and validate the attained improvements using wave tank and full scale testing. In parallel, we will bring along the development of a wave prediction system that is required to enable effective control and test it at full scale. The purposes of this report are to: 1. Plan and document the 1/25th scale device testing at the wave-tank facility; 2. Document the test article, setup and methodology, sensor and instrumentation, mooring, electronics, wiring, and data flow and quality assurance; 3. Communicate the testing results between the associated members; 4. Facilitate reviews that will help to ensure all aspects (risk, safety, testing procedures, etc.); 5. Provide a systematic guide to setting up, executing and decommissioning the experiment.

16 TIDAL AND WAVE POWER↗

Follow-on Report of Analysis of Approaches to Supplemental Treatment of Low-Activity Waste at the Hanford Nuclear Reservation (Vol. I)

The Hanford Site, in southeast Washington State, is preparing to disposition approximately 56,000,000 gallons (56 Mgal) of radioactive and chemically hazardous wastes currently stored in underground tanks at the site. Tank wastes will be divided into a high-activity fraction and a low-activity fraction for subsequent treatment and disposition. A waste processing and treatment facility, the Waste Treatment and Immobilization Plant (WTP), will include the high-level waste (HLW) vitrification facility (WTP HLW Vitrification Facility) for immobilizing the high-activity fraction and a low-activity waste (LAW) vitrification facility (WTP LAW Vitrification Facility) for immobilizing the low-activity fraction. Both facilities will use vitrification technology to immobilize the Hanford tank wastes in a glass waste form. The volume of LAW to be treated and disposed of following waste retrieval and WTP operations will exceed the planned processing capacity of the WTP LAW Vitrification Facility. ORP-11242,-River Protection Project System Plan, estimates a shortfall in LAW treatment capacity of approximately 56 Mgal, approximately 50% of the projected LAW volume. To maintain the planned tank waste processing mission schedule, the U.S. Department of Energy (DOE) will require additional LAW treatment capacity (termed “supplemental LAW”) external to the WTP process. LAW must be solidified by a treatment technology before the waste can be permanently disposed of in an approved DOE on-site disposal facility or a commercial (state or U.S. Nuclear Regulatory Commission [NRC-licensed]) off-site mixed low-level waste disposal facility. A decision on the approach to supplemental LAW treatment, processing, and disposal has not yet been made

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

Regulatory Spike Testing of RPP-WTP LAW and HLW Glasses for Compliance with Land Disposal Restrictions, VSL-03R3760-1, Rev. 1

The United States Department of Energy’s (DOE’s) Hanford site is the current location of storage of about 50 million gallons of mixed waste. This waste is stored in underground tanks at the Hanford site and is both a listed and characteristic waste, as defined in 40 CFR Part 261, and a dangerous waste according to Chapter 173-303 of the Washington Administrative Code (WAC). The waste is also subject to the Land Disposal Restrictions (LDR) (40 CFR Part 268 and WAC 173-303-140). The River Protection Project - Waste Treatment Plant (RPP-WTP) will provide DOE with a means for treating this waste by vitrification (for subsequent disposal). The tank waste will be partitioned into low and high activity fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed of in an engineered facility on the Hanford site while the IHLW product will be directed to the national deep geological disposal facility for high level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Tank 22 Demister Solids Responsible for Preventing Adequate Purge Ventilation Flow (U)

In December 2020, about 2.5 grams of the solid material from the Tank 22 purge ventilation demister, responsible for preventing adequate purge ventilation flow, were delivered to Savannah River National Laboratory (SRNL) by Savannah River Remediation (SRR) for analysis to identify the chemical nature of the solids and possibly address why fresh water and caustic flushes with 50 wt. % sodium hydroxide solution are essentially ineffective in dissolving or dislodging the accumulated solids from the Tank 22 demister at low ambient temperature conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanisms and kinetics of citrate-promoted dissolution of a uranyl phosphate mineral

The formation of uranyl phosphate precipitates is a remediation strategy to limit the mobility of uranium in contaminated soils. However, exposure to organic ligands, like the plant exudate citrate, can remobilize the uranium. The purpose of this study is to provide a more thorough comprehension of citrate-promoted dissolution of a uranyl phosphate mineral, chernikovite [(H 3 O)(UO 2 )(PO 4 )·3H 2 O], by determining the extent of uranium release from chernikovite at a wide range of citrate concentrations. Here we have quantified the kinetics of dissolution and proposed potential mechanisms of chernikovite dissolution to gain a better understanding of the fate of uranyl phosphate precipitates in the environment. Batch dissolution and continuously stirred tank reactor (CSTR) experiments indicate that increasing citrate concentrations from 0.1 mM to 50 mM increases the concentration of dissolved uranium. However, at citrate concentrations of 10 mM and greater, the effectiveness of the ligand to enhance the dissolution decreases. Density functional theory modeling and Raman spectroscopy indicate a strong interaction between citrate and the uranyl ions at the surface of the uranyl phosphate. The interaction between citrate and uranyl suggests the formation of an alteration layer of uranyl-citrate surface complexes, which could impede uranium release at citrate concentrations of 10 mM or higher. Together, these results indicate that the citrate-promoted dissolution of chernikovite is a fast reaction that is hindered by a combination of surface saturation and a secondary-phase precipitation reaction at higher concentrations of citrate and reaction times greater than or equal to 72 min based on the hydraulic residence time of CSTR experiments. These findings improve our understanding of the stability of uranyl phosphate for use in sequestration of uranium groundwater plumes at contaminated sites.

58 GEOSCIENCES↗

System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during a NG shortage offer one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73- bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dis- patch is proposed to allow representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

duel-fuel generator performance↗

Long-Term PCT of ILAW Glasses (Final Report FY2020)

About 50 million gallons of high-level mixed waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in a near-surface engineered facility – the Integrated Disposal Facility (IDF) – on the Hanford site, while the IHLW product is designed for deep geological disposal in a national facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The objective of the work described in this report is to perform testing, data collection, and analyses for the ILAW glass product for subsequent use in the performance assessment (PA) of the IDF to assess potential environmental risks associated with long-term storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗