Engineering PapersSearch

SEARCH · Engineering Papers

Results for “TREAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Developments in Processing Criteria for Iron Phosphate Waste Form Design for Treating Electrorefiner Salt Wastes

This report describes work done under a Nuclear Energy University Partnership (NEUP) project that included a collaborative effort between Pacific Northwest National laboratory, University of Nevada Reno, University to Utah, and Missouri University of Science and Technology. In this project, the main goals were the following: (1) to assess H3PO4 dechlorination parameters for halide removal from salt simulants, (2) to evaluate crucible compatibility with iron phosphate glass melts, and (3) to evaluate waste form properties within a ternary system of P2O5 (added as H3PO4), Fe2O3 and fission product simulants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Development of local hybrid density functionals to treat self-interaction error and many-electron effects

The goal of this project was to improve density functional theory (DFT) for systems where conventional semilocal approximations are limited by self-interaction error (SIE) and by near-degeneracy or strong many-electron effects. While DFT remains the only broadly practical first-principles framework for large-scale materials simulations, its predictive accuracy is often challenged in situations involving stretched bonds, charge transfer, transition-metal chemistry, magnetic couplings, band gaps, and correlated electronic states. This project addressed these limitations by developing physically grounded and numerically robust exchange–correlation functionals that retain the efficiency of modern DFT while extending its predictive scope.

36 MATERIALS SCIENCE

Reducing the Barrier Height in Organic Transistors

Abstract Reducing the Schottky barrier height and Fermi level de‐pinning in metal‐organic semiconductor contacts are crucial for enhancing the performance of organic transistors. The reduction of the Schottky barrier height in bottom‐contact top‐gate organic transistors is demonstrated by adding 1 nm thick atomic layer deposited Al 2 O 3 on the source and drain contacts. By using two different donor‐acceptor copolymers, both p‐ and n‐ type transistors are investigated. Temperature‐dependent current–voltage measurements from non‐treated, self‐assembled monolayer treated, and Al 2 O 3 treated Au source‐drain contact field‐effect transistors with varying channel lengths are carried out. The drain current versus drain voltage near zero gate voltage, which may be described by the thermionic emission model at temperatures above 150 K, allows the estimation of the Schottky barrier height ( φ B ). The Al 2 O 3 contact‐treated transistors show more than 40% lower φ B compared with the non‐treated contacts in the p ‐type transistor. Similarly, an isoindigo‐based transistor, with n ‐type transport, shows a reduction in φ B with Al 2 O 3 treated contacts suggesting that such ultrathin oxide layers provide a universal method for reducing the barrier height.

Ghobadi, Arash

Effect of bisphosphonate treatment on the oim mouse middle ear ossicles' structure, composition and hearing

Hearing loss is common in people with osteogenesis imperfecta (OI or brittle bone disease). Bisphosphonates are commonly used to treat long bone fragility in children with OI. However, its impact on the bone quality of the middle ear ossicles and hearing remains unknown. This study determines whether bisphosphonates treatment itself may contribute to hearing loss in OI by evaluating its effects in the oim/oim mouse model of severe OI having normal auditory function. Specifically, this study reports the effects of alendronate (ALN), a nitrogen-containing bisphosphonate, on ossicle morphology, porosity, and elemental composition in 14-week-old oim/oim mice treated weekly, starting at 2 weeks of age. The ossicles were examined using synchrotron microtomography and X-ray fluorescence microscopy (XFM). Hearing was assessed longitudinally until 26 weeks of age by determining auditory brainstem response (ABR) thresholds in another group of mice also treated weekly starting at 2 weeks of age. ALN treatment further reduces in size the already small oim/oim ossicles, specifically in female mice. Porosity, bone composition, and hearing function, however, were generally not affected by the ALN treatment. Furthermore, ALN does not prevent joint fusions, excessive bone formations, or enlarged joint spaces in WT or oim/oim experimental groups. One ALN-treated oim/oim mouse with a bone formation in the interior of the footplate, and one ALN-treated WT mouse with a fixed footplate had frequency-specific hearing loss. Since footplate abnormalities are not observed in PBS-treated mice in this study, it remains unclear whether ALN fails to prevent these changes or contributes to their development. Future studies should investigate the mechanisms of ossicular abnormalities and bisphosphonates modulatory role in the ossicles.

60 APPLIED LIFE SCIENCES

Nanoscale structural evolution and phase transformation of geopolymers: In situ SAXS/WAXS investigation under uniaxial tension at elevated temperatures

This investigation delves into the degradation mechanisms of high-density polyethylene geomembranes (PE GMXs) under a spectrum of conditions, replicating real-world scenarios within a rigorously controlled laboratory setting. The treatment protocols applied induced a notable increase in the crystallinity of the treated specimens relative to the untreated controls. Small-angle x-ray scattering (SAXS) analysis identified an initial long period (interlamellar distance) of 16.9 nm for the untreated polymer, which expanded by 19.5% at a strain of 16.7 percent. Conversely, the treated PE GMXs exhibited a more gradual elongation of the long period, with an increase of merely 10.6% at a strain of 23.3 percent. At an elevated temperature of 65°C, both samples exhibited pronounced strain hardening, with the treated PE GMXs demonstrating superior stability even at a strain of 150 percent. Wide-angle x-ray scattering (WAXS) experiments corroborated these observations, revealing that the diffraction patterns of the untreated PE remained stable up to a strain of 16.7%, whereas those of the treated PE remained distinct up to a strain of 46.1 percent. Scanning electron microscopy (SEM) images substantiated the formation of a shish–kebab structure in the treated samples. The study concludes that the geopolymer underwent oxidation and material degradation as a result of the chemical and mechanical treatments, transitioning to a more crystalline state and concomitantly losing its initial elasticity.

36 MATERIALS SCIENCE

Gear Test Assembly - Experimental Testing and Analysis of Gears and Bearings - FY2026

The Gear Test Assembly (GTA) is an experimental test apparatus built and installed in the Mechanisms and Engineering Test Loop (METL) at Argonne National Laboratory (ANL). While designed to accommodate a variety of components intended for use in advanced compact in-vessel transfer machine, the focus of GTA been the testing of large radial spur gears. The performance of the components used in GTA motivates the choices made in the design, components, and material choices for the forthcoming METL test articles; the Gripper Test Assembly (GrTA), and the Bearing Test Assembly (BTA). To date, GTA has completed nine experimental testing campaigns and achieved over 21 million revolutions under prototypic sodium fast reactor loads and operating conditions. This report provides an overview and results for the two most recent experiments Campaign #8 and Campaign #9. `Campaign #8 was the first campaign to make use of a set of nickel alloy radial spur gears, made from Hastelloy C-22HS, and combined with heat-treated tapered roller bearings. The bearings and torque profile used allowed Campaign #8 to be directly compared with Campaign #1 where Inconel 718 gears were used instead. Campaign #8 attained 1,058,880 shaft revolutions within 23% of the 1,314,855 revolutions achieved in Campaign #1. These results demonstrate that the heat-treated tapered roller bearings show consistent increased lifetimes, approximately three times longer than for non heat-treated taper rollers, and that the particular material of the gear does not play a substantial role in performance. Similar to Campaign #7 where bearing failure resulted in fragmentation and transport of bearing material into the gear teeth led to tooth damage in the Inconel gears, a similar process led to the damage of the Hastelloy gears. Subsequent NDE analysis showed that the damage was only limited to the tooth surface and does not extend into the gear interiors. Based on the NDE reports, the Hastelloy gears can be reconditioned and put back into service for future campaigns as was done for the Inconel gears. Reconditioned Inconel 718 gears damaged in Campaign #7 were returned to service in Campaign #9 and paired with non heat-treated tapered roller bearings. In Campaign #9 a novel set of operating conditions were implemented whereby the gears and bearings were cycled between hot, submerged refueling conditions where fuel handling operations occurred and cold, dry, and inert conditions where the sodium was drained and the vessel was allowed to cool simulating long, ex-vessel storage of the fuel handling machine. A total of eight of these operating cycles were achieved before a bearing failure occurred after the accumulation of 475,692 shaft revolutions were achieved. During Campaign #9, one of the drive motors was damaged and over the course of a 240 day standby period, the entire GTA drive system was upgraded from a 480VAC system to a 240VAC system that provided the opportunity to consolidate wall-space in the METL facility and provide more space for additional test articles being installed in the coming year. The over 475,000 shaft revolutions achieved in Campaign #9 eclipses the previous record for lifetime of non heat-treated tapered roller bearings held by Campaign #3 of 392,000 shaft revolutions. Further analysis and future campaigns hope to shed light on the cause of this approximately 17% increase in lifetime.

42 ENGINEERING

The Ductility of 49Fe-49Co-2V Soft Magnetic Alloy Bar: Surface Effects and Test Methods

The tensile ductility of 49Fe-49Co-2V (Hiperco® 50A) bar was investigated in both as-received and heat-treated conditions. The as-received/machined specimens exhibit very low ductility compared to samples where heat treatment was the final step prior to testing. Microstructural characterization showed that internal residual strain from bar processing and, most importantly, surface machining damage, cause lower elongation in the as-received material. Because fracture of this intermetallic alloy initiates at the surface, it is particularly susceptible to surface machining damage, i.e., the near-surface region has already exhausted most of its ability to accumulate tensile strain. During heat treatment, the internal residual strain and near-surface machining damage are eliminated and ductility is improved, despite a higher degree of crystallographic ordering in the heat-treated condition (which typically lowers ductility). Furthermore, if machining is again performed after heat treatment, the material again exhibits brittle behavior, even with only light touch-up machining passes. Here, in this work, methods of tensile strain measurement were investigated, namely conventional knife-edge extensometry and noncontact digital image correlation (DIC) on heat-treated material. For clip-on knife-edge extensometry, the range of failure strain was 2.5-5.5% for heat-treated Hiperco. For noncontact methods, ductility up to 7% was observed. The results highlight the tendency for the alloy to fail at surface imperfections, even those produced by application of the extensometer itself. Noncontact laser extensometry is recommended for determining the intrinsic ductility of the alloy. A method of laser surface modification was developed which increased ductility by ~ 100% compared to unmodified samples. The high cooling rates achieved during laser surface processing can bypass the ordering reaction and produce a ductile disordered structure at the surface that exhibits ductile fracture characteristics.

EBSD

Functional group activation and coupling agent migration induced by plasma treatment in adhesive for enhanced toughness of metal-composite joints

Commercial adhesive paste was additionally activated using low-power oxygen plasma with different plasma exposure durations to investigate its interfacial bonding contribution in adhesively-bonded Aural-5/CFRP-PA6 double cantilever beam (DCB) joints with plasma-treated adherends. The plasma-treated adhesive showed enhanced functional peak intensities in Fourier transfer infrared spectroscopy (FTIR) as plasma exposure time was increased, and some degree of oxidation was also detected via X-ray photoelectron spectroscopy (XPS). A small molecule, dicyandiamde (coupling agent) in adhesive was migrated to adhesive layer, where double concentration of coupling agent was detected after 10 minutes of plasma treatment. As a result, characterization of the adhesive/CFRP-PA6 interface after DCB fracture showed additional chemical bonds formed through amine-initiated epoxy ring opening polymerization, as well as amide bonds and ester bonds. In conclusion, these additional bonds at the adhesive/CFRP-PA6 interfaces led to significantly increased failure extensions and fracture energies of the joints as the plasma exposure time on the adhesive increased, compared to the joints with plasma-treated adherends but non-plasma-treated adhesive as commonly seen in the literature.

36 MATERIALS SCIENCE

Role of mechanical stress localizations on the radiation hardness of AlGaN/GaN high electron mobility transistors

Multi-material, multi-layered systems such as AlGaN/GaN high electron mobility transistors (HEMTs) contain residual mechanical stresses that arise from sharp contrasts in device geometry and materials parameters. These stresses, which can be either tensile or compressive, are difficult to detect and eliminate because of their highly localized nature. We propose that their high-stored internal energy makes potential sites for defect nucleation sites under radiation, particularly if their locations coincide with the electrically sensitive regions of a transistor. In this study, we validate this hypothesis with molecular dynamic simulation and experiments exposing both pristine and annealed HEMTS to 2.8 MeV Au +3 irradiation. Our unique annealing process uses mechanical momentum of electrons, also known as the electron wind force (EWF) to mitigate the residual stress at room temperature. High-resolution transmission electron microscopy and cathodoluminescence spectra reveal the reduction of point defects and dislocations near the two-dimensional electron gas region of EWF-treated devices compared to pristine devices. The EWF-treated HEMTs showed relatively higher resilience with approximately 10% less degradation of drain saturation current and ON-resistance and 5% less degradation of peak transconductance. Both mobility and carrier concentration of the EWF-treated devices were less impacted compared to the pristine devices. Our results suggest that the lower density of nanoscale stress localization contributed to the improved radiation tolerance of the EWF-treated devices. Intriguingly, the EWF is found to modulate the defect distribution by moving the defects to electrically less sensitive regions in the form of dislocation networks, which act as sinks for the radiation induced defects and this assisted faster dynamic annealing.

AlGaN/GaN HEMTs

A Refined BISON-Griffin Workflow For Designing Targeted TRISO Transient Experiments In The Transient Reactor Test Facility

U.S. industry is expected to deploy tristructural isotropic (TRISO) particle fuel technologies for commercial reactors within the next decade. In our previous work, we defined a preliminary transient design space for TRISO fuels, identified potential gaps in the available data, and began to develop multiphysics modeling tools that could be applied to design targeted Transient Reactor Test Facility (TREAT) experiments to fill these gaps. This work builds on that foundation by (1) updating BISON fuel performance and Griffin reactor physics models to reflect the current TREAT experiment tube and capsule designs,(2) coupling the codes to improve the accuracy and usability of the transient design analyses, and (3) demonstrating their use over an expanded design space that includes fuel burnup. The simulated mechanical responses of the TRISO particles were complex functions of fission product accumulation, fission gas release, and irradiation-induced dimensional change in the pyrolytic carbon layers. Predicted tangential stresses in particle silicon carbide layers were least compressive for preheated tests involving fresh fuels but remained compressive throughout the ranges of temperature, heat rate, and burnup considered in this work. Finally, comparisons between the potential TREAT transients and historical test reactor irradiations showed that the TREAT tests would produce significantly lower average energy deposition rates, yielding less severe transients with greater relevance to near-term commercial applications. Use of these predictive capabilities has the potential to increase the value of each test, improving the overall efficiency and cost effectiveness of transient testing for TRISO and other advanced fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Carbon sequestration into lime-stabilized soils: Engineering and mineralogical characterization

Stabilizing weak clayey soils with lime is an effective method for improving the mechanical properties of soil. However, lime production is an energy-intensive process producing significant CO 2 emissions in lime-stabilized soils, which can be counteracted through accelerated carbonation that enhances its engineering performance. The present study evaluates accelerated carbonation of lime-treated soils by adding gaseous (CO 2 -rich gas), liquid (water-CO 2 mixture), and solid (sodium bicarbonate) CO 2 sources. Results indicated that samples carbonated with gaseous CO 2 exhibited 100% lime carbonation, while samples treated with solid and aqueous sources of CO 2 had a mean lime carbonation of 60% and 40%, respectively. Further, all lime-treated-carbonated samples exhibited a mean 50% increase in unconfined compressive strength compared to the untreated samples after a 7-day curing period. Durability evaluation through cyclic wetting and drying indicated that the carbonated samples had higher durability than the untreated samples. X-ray computed tomography showed that adding solid and liquid sources of CO 2 facilitated the flocculation of montmorillonite, reducing the porosity. However, a higher dosage of solid CO 2 induced clay dispersion, increasing the porosity. X-ray diffraction and thermogravimetric analysis verified CO 2 sequestration through the formation of calcite, a thermodynamically stable polymorph of calcium carbonate.

58 GEOSCIENCES

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography

Unraveling the relationship between physicochemical properties of NiFeReOx catalysts and the correlated performance toward electrochemical oxygen evolution reaction

NiFeO x catalysts with single site Re dopants exhibit much higher active and stability toward electrochemical oxygen evolution reaction (OER) compared to traditional NiFeO x catalysts. Nevertheless, the relationship between physicochemical properties of NiFeReO x catalysts and the correlated performance toward OER is unclear, which hampers to enhance the OER performance further. Herein, we prepared a series of NiFeReO x catalysts with different physicochemical properties by treating them at different temperatures (up to 350 °C) and then evaluated their performance toward OER. Here, the results show that heat treatment can convert all metal oxidation states to higher values as well as specific surface areas, which are believed to favor real active site generation and OER activity enhancement. A decrease in activity is observed with the temperature increase at the low current range, and the smallest overpotential of 248 mV at 10 mA cm −2 is achieved with the pristine NiFeReO x catalyst. In contrast, the heat-treated samples possess smaller Tafel slopes and lower charge transfer resistance likely due to enhanced intrinsic activity (from higher oxidation states) and conductivity, which facilitate the reaction kinetics and surpass the pristine sample at a large current density. Additionally, the sample treated at 350 °C exhibits a higher activity at 1000 mA cm −2 (1.68 V vs. RHE compared to pristine sample of 1.92 V vs. RHE); however, it manifests a poorer stability compared to the pristine one due to the imbalance of reconstruction/transformations that occurred on the catalyst surface during OER operation. Our work unravels the relationship between physicochemical properties of NiFeReO x catalysts and the correlated OER performance and provides valuable insights for designing NiFeReO x catalysts with high activity and durability.

Catalyst reconstruction