Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRAPPED MAGNETIC FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analytic Expressions for a 2D Permanent Magnetic Lattice with a 3D Bias Magnetic Field for Ultracold Atoms

In this paper, we discuss a permanent magnetic lattice for trapping and manipulating ultracold atoms and quantum degenerate gases. Considering three components of an external bias magnetic field, B{sub 1x}, B{sub 1y} and B{sub 1z} which are applied for controlling the magnetic lattice parameters, we obtain analytic expressions for the magnetic field minima locations as well as their absolute values, curvatures of the absolute value of the magnetic field, trap frequencies and barrier heights between minima in all directions. B{sub 1z} had previously been considered in numerical works, but not in analytic calculations, due to difficulty in obtaining the analytic expressions for the physical parameters and sufficiency of considering only B{sub 1x} and B{sub 1y}. Including the third component in this study provides further control over the magnetic lattice parameters. Also, in the presence of unavoidable bias magnetic fields with a z-component such as the Earth’s magnetic field, our analytic calculations could be useful. In numerical calculations, we have considered up to n{sub s} = 1001 square magnetic slabs in each direction of the 2D lattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absence of magnetic trapping on closed field lines at Neptune

The large offset of Neptune's magnetic field in an offset tilted dipole (OTD) approximation allows some fraction of magnetospheric field lines to have monotonically increasing field magnitude over their entire length in the magnetosphere. The usual magnetic trapping is impossible on such field lines, meaning that all charged particles on these field lines will precipitate after mirroring at most once. These field lines can be thought of as the part of the global magnetic anomaly where no particles on the corresponding drift shells remain trapped for an entire rotation of the planet. In this paper we examine both the morphology and size of the affected surface area in the OTD2 and O8 magnetic field models. For regions where there are indications that part of the aurora could be due to monotonic field line precipitation we analyze whether these field lines could be sufficiently populated to produce auroral signatures by considering photoelectron production rates and radial diffusion. We conclude that monotonic field line precipitation may contribute to the observed Neptune aurora but does not explain the global phenomenon.

Paranicas, C.↗

A novel technique to measure interface trap density in a GaAs MOS capacitor using time-varying magnetic fields

Interface trap density (D{sub it}) in a GaAs metal-oxide-semiconductor (MOS) capacitor can be measured electrically by measuring its impedance, i.e. by exciting it with a small signal voltage source and measuring the resulting current through the circuit. We propose a new method of measuring D{sub it} where the MOS capacitor is subjected to a (time-varying) magnetic field instead, which produces an effect equivalent to a (time-varying) voltage drop across the sample. This happens because the electron chemical potential of GaAs changes with a change in an externally applied magnetic field (unlike that of the gate metal); this is not the voltage induced by Faraday’s law of electromagnetic induction. So, by measuring the current through the MOS, D{sub it} can be found similarly. Energy band diagrams and equivalent circuits of a MOS capacitor are drawn in the presence of a magnetic field, and analyzed. The way in which a magnetic field affects a MOS structure is shown to be fundamentally different compared to an electrical voltage source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion Storage Tests with the High Performance Antimatter Trap (HiPAT)

The NASA/Marshall Space Flight Centers (NASA/MSFC) Propulsion Research Center (PRC) is evaluating an antiproton storage system, referred to as the High Performance Antiproton Trap (HiPAT). This interest stems from the sheer energy represented by matter/antimatter annihilation process with has an energy density approximately 10 order of magnitude above that of chemical propellants. In other terms, one gram of antiprotons contains the equivalent energy of approximately 23 space shuttle external tanks or ET's (each ET contains roughly 740,000 kgs of fuel and oxidizer). This incredible source of stored energy, if harnessed, would be an enabling technology for deep space mission where both spacecraft weight and propulsion performance are key to satisfying aggressive mission requirements. The HiPAT hardware consists of a 4 Tesla superconductor system, an ultra high vacuum test section (vacuum approaching 10(exp -12) torr), and a high voltage confinement electrode system (up to 20 kvolts operation). The current laboratory layout is illustrated. The HiPAT designed objectives included storage of up to 1 trillion antiprotons with corresponding lifetimes approaching 18 days. To date, testing has centered on the storage of positive hydrogen ions produced in situ by a stream of high-energy electrons that passes through the trapping region. However, due to space charge issues and electron beam compression as it passes through the HiPAT central field, current ion production is limited to less then 50,000 ions. Ion lifetime was determined by counting particle populations at the end of various storage time intervals. Particle detection was accomplished by destructively expelling the ions against a micro-channel plate located just outside the traps magnetic field. The effect of radio frequency (RF) stabilization on the lifetime of trapped particles was also examined. This technique, referred to as a rotating wall, made use of a segmented electrode located near the center of the trap on which various phases of a particular frequency were applied. Various experiments were performed illustrating the ability of an RF drive to both prolong and reduced the lifetimes of various ion species depending on the selected frequency. HiPAT is now being reconfigured for testing with an ion source that will provide both positive and negative hydrogen ions from an external source. This ion system shall provide higher fill capacity (order of million of ions per shot), stacking of multiple shots, and injection schemes typical of a realistic antiproton delivery system.

Martin, James J.↗

Nonlinear electron acceleration by oblique whistler waves: Landau resonance vs. cyclotron resonance

This paper is devoted to the study of the nonlinear interaction of relativistic electrons and high amplitude strongly oblique whistler waves in the Earth's radiation belts. We consider electron trapping into Landau and fundamental cyclotron resonances in a simplified model of dipolar magnetic field. Trapping into the Landau resonance corresponds to a decrease of electron equatorial pitch-angles, while trapping into the first cyclotron resonance increases electron equatorial pitch-angles. For 100 keV electrons, the energy gained due to trapping is similar for both resonances. For electrons with smaller energy, acceleration is more effective when considering the Landau resonance. Moreover, trapping into the Landau resonance is accessible for a wider range of initial pitch-angles and initial energies in comparison with the fundamental resonance. Thus, we can conclude that for intense and strongly oblique waves propagating in the quasi-electrostatic mode, the Landau resonance is generally more important than the fundamental one.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observations of flux motion in niobium films

A magnetic field trapped in a superconducting sphere was examined at temperatures from 4.6 K to 5.5 K. The sphere was the rotor of a precision gyroscope and was made of fused quartz and coated with a sputtered niobium film. The rotor diameter was 3.8 cm. The film thickness was 2.5 microns. The tests were carried out at an ambient magnetic field of about 1 mG. Unexpected instability of the trapped field was observed. The experimental results and possible explanations are presented.

Xiao, Y. M.↗

Effects of Pressure on Superconducting Properties and Vortex Pinning of CaKFe 4 As 4 Single Crystals

Measurements of low field magnetization, trapped flux magnetization and 5 K flux creep in single crystal of CaKFe 4 As 4 under pressure up to 7.5 GPa in a diamond pressure cell are presented. Further, the observed evolution of the temperature dependence of the self-field critical current and slowing down of the base temperature flux creep rate are explained within the two sources of pinning hypothesis involving presence of CaFe 2 As 2 intergrowths suggested in the literature. Above the half collapsed tetragonal structural transition under pressure, where superconductivity is non-bulk or absent, critically diminished or no diamagnetism and flux trapped magnetization were observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of the London moment and trapped flux in precision gyroscopes

The London-moment readout has been observed in flight quality gyroscopes and it has been demonstrated that it is possible to reduce magnetic field trapped in these gyroscopes to levels as low as 1.5 x 10 exp -11 T. A preliminary analysis shows that the horizontal component of the London-moment signal is 60 percent of the total expected London-moment signal and is proportional to the gyro spin speed. Experiments were carried out in a unique ground test facility which was designed to provide the conditions necessary to observe the London moment of the spinning gyroscope.

Xiao, Y. M.↗

Four ppm measurement of the antihydrogen ground-state hyperfine splitting

The hydrogen atom is a touchstone for the foundations, evolution and frontiers of quantum theory. Key spectral lines of this atom have been determined to remarkable precision. Our research focuses on the study of antihydrogen, the antimatter counterpart of hydrogen. We test fundamental symmetries of nature (such as simultaneous charge conjugation, parity inversion, and time reversal or CPT symmetry) through precision comparisons of these atomic systems. Recent 1S–2S spectroscopic measurements on trapped antihydrogen have achieved relative precisions of parts per trillion. However, the ground-state hyperfine splitting, which is sensitive to the internal structure of the antiproton, has only been measured to 400 parts per million (ppm). Here we report a 4 ppm measurement of the antihydrogen ground-state hyperfine splitting energy a 1S , advancing the state-of-the-art precision by two orders of magnitude. From microwave spectroscopy experiments with roughly 24,000 anti-atoms, we determine ${a}_{1{\rm{S}}}/h=\mathrm{1,420,404.8}\pm 1.1(\mathrm{stat.})\pm 5.6\,(\mathrm{sys.})\,\text{kHz}$ in a 1-T magnetic field, consistent with expectations for hydrogen. At this level, our measurement is sensitive to the internal structure of the antiproton, which contributes at about 40 ppm and is approaching the limit of existing theoretical analyses. The gains we report are the product of marked advances in magnetic trap field control, stabilization and characterization; anti-atom spin-state manipulation; and improved antihydrogen accumulation rate.

74 ATOMIC AND MOLECULAR PHYSICS↗

SQUIDs De-fluxing Using a Decaying AC Magnetic Field

Flux trapping is the Achilles’ heel of all superconductor electronics. The most direct way to avoid flux trapping is a prevention of superconductor circuits from exposure to magnetic fields. Unfortunately this is not feasible if the circuits must be exposed to a strong DC magnetic field even for a short period of time. For example, such unavoidable exposures take place in superparamagnetic relaxation measurements (SPMR) and ultra-low field magnetic resonance imaging (ULF MRI) using unshielded thin-film SQUID-based gradiometers. Unshielded SQUIDs stop working after being exposed to DC magnetic fields of only a few Gauss in strength. In this paper we present experimental results with de-fluxing of planar thin-film LTS SQUID-based gradiometers using a strong decaying AC magnetic field. We used four commercial G136 gradiometers for SPMR measurements with up to a 10 mT magnetizing field. Strong 12.9 kHz decaying magnetic field pulses reliably return SQUIDs to normal operation 50 ms after zeroing the DC magnetizing field. This new AC de-fluxing method was also successfully tested with seven other different types of LTS SQUID sensors and has been shown to dissipate extremely low energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Frequency Dependence of Trapped Flux Sensitivity in SRF Cavities

In this letter, we present the frequency dependence of the vortex surface resistance of bulk niobium accelerating cavities as a function of different state-of-the-art surface treatments. Higher flux surface resistance per amount of trapped magnetic field—sensitivity—is observed for higher frequencies, in agreement with our theoretical model. Higher sensitivity is observed for N-doped cavities, which possess an intermediate value of the electron mean-free-path, compared to 120 °C and EP/BCP cavities. Experimental results from our study showed that the sensitivity has a non-monotonic trend as a function of the mean-free-path, including frequencies other than 1.3 GHz, and that the vortex response to the rf field can be tuned from the pinning regime to flux-flow regime by manipulating the frequency and/or the mean-free-path of the resonator, as reported in our previous studies. The frequency dependence of the trapped flux sensitivity to the amplitude of the accelerating gradient is also highlighted.

43 PARTICLE ACCELERATORS↗

Radio-Frequency Illuminated Superconductive Disks: Reverse Josephson Effects and Implications for Precise Measuring of Proposed Gravity Effects

We have previously reported results using a high precision gravimeter to probe local gravity changes in the neighborhood of large bulk-processed high-temperature superconductors. It have been indicated three essential components to achieve anomalous gravity effects, namely large, two-layer high-temperature YBCO superconductors, magnetic levitation and AC input in the form of radio-frequency (RF) electromagnetic fields. We report experiments on RF-illuminated (1-15 MHz) superconducting disks with corresponding gravity readings indicating an apparent increase in observed gravity of approximately 3-5 x l0(exp -5)cm/sq s, above and to the side of the superconductor. In this preliminary study, RF- illumination is achieved using a series of large radius (15 cm) spiral antenna with RF power inputs equal to or greater than 90 W. The observed gravitational modification range is significantly lower than the 2.1% gravity modification. The error analyses of thermal and electromagnetic interference in a magnetically shielded gravimeter with vacuum enclosures, Faraday cages and shielded instrument leads, are outlined both experimentally and theoretically. The nearly exact correspondence between the peak gravity effects reported and the well-known peak in AC resistance in superconductors (2-7 MHz, owing to reverse Josephson quantum effects) suggests that electrical resistance will arise in this frequency range and subsequently any trapped magnetic fields in the superconductor may disperse partially into the measuring instrument's local environment. Implications for propulsion initiatives and RF-heating in superconductors will be discussed.

Noever, David A.↗

A Low-Cost Fabrication Technique for the Growth of Single-Domain GdBCO Bulk Superconductor from Raw Metal Oxides

A single-domain GdBCO bulk superconductor is usually fabricated using a mixture of pre-reacted precursor powders (including GdBa{sub 2}Cu{sub 3}O{sub 7−δ} and Gd{sub 2}BaCuO{sub 5}) by the top-seeded melt texture growth (TSMTG) process. However, the synthesis of pure-phase precursor powder by the solid-state sintering reaction can not only consume time for weeks but also prolong the fabrication process and can lead to a low-efficiency and high-cost process. In this paper, we reported the successful growth of single-domain GdBCO bulk superconductors by the top-seeded metallic oxide melt growth (TS-MOMG) process in which the raw materials of Gd{sub 2}O{sub 3}, BaO, and CuO, the three different metallic oxides, are just involved to fabricate the single-domain GdBCO bulk superconductors. After detailed investigations in the morphology, levitation force, trapped magnetic field, and critical temperature of the grown samples with different ratios, it was found that the simplified precursor-phase source can be used to fabricate the single-domain GdBCO bulk superconductors more efficiently, which can combine the crystal growth procedure and greatly economize the preparation cost and the time to the most extent.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Emittance of short-pulsed high-current ion beams formed from the plasma of the electron cyclotron resonance discharge sustained by high-power millimeter-wave gyrotron radiation

We present experimental results on measuring the emittance of short-pulsed (≤100 μs) high-current (80–100 mA) ion beams of heavy gases (Nitrogen, Argon) formed from a dense plasma of an ECR source of multiply charged ions (MCI) with quasi-gas-dynamic mode of plasma confinement in a magnetic trap of simple mirror configuration. The discharge was created by a high-power (90 kW) pulsed radiation of a 37.5-GHz gyrotron. The normalized emittance of generated ion beams of 100 mA current was (1.2–1.3) π mm mrad (70% of ions in the beams). Comparing these results with those obtained using a cusp magnetic trap, it was concluded that the structure of the trap magnetic field lines does not exert a decisive influence on the emittance of ion beams in the gas-dynamic ECR source of MCI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-plasmas in the relativistic-transparency regime: science and applications

Laser-plasma interactions in the novel regime of relativistically induced transparency (RIT) have been harnessed to generate intense ion beams efficiently with average energies exceeding 10 MeV/nucleon (>100 MeV for protons) at “table-top” scales in experiments at the LANL Trident Laser. By further optimization of the laser and target, the RIT regime has been extended into a self-organized plasma mode. This mode yields an ion beam with much narrower energy spread while maintaining high ion energy and conversion efficiency. This mode involves self-generation of persistent high magnetic fields (~10 4 T, according to particle-in-cell simulations of the experiments) at the rear-side of the plasma. These magnetic fields trap the laser-heated multi-MeV electrons, which generate a high localized electrostatic field (~0.1 TV/m). After the laser exits the plasma, this electric field acts on a highly structured ion-beam distribution in phase space to reduce the energy spread, thus separating acceleration and energy-spread reduction. Thus, ion beams with narrow energy peaks at up to 18 MeV/nucleon are generated reproducibly with high efficiency (≈5%). The experimental demonstration has been done with 0.12 PW, high-contrast, 0.6 ps Gaussian 1.053 μm laser pulses irradiating planar foils up to 250 nm thick at 2–8 × 10 20 W/cm 2 . These ion beams with co-propagating electrons have been used on Trident for uniform volumetric isochoric heating to generate and study warm-dense matter at high densities. These beam plasmas have been directed also at a thick Ta disk to generate a directed, intense point-like Bremsstrahlung source of photons peaked at ~2 MeV and used it for point projection radiography of thick high density objects. In addition, prior work on the intense neutron beam driven by an intense deuterium beam generated in the RIT regime has been extended. Neutron spectral control by means of a flexible converter-disk design has been demonstrated, and the neutron beam has been used for point-projection imaging of thick objects. Finally, we discuss the plans and prospects for further improvements and applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results of dynamic testing of GP-B spherical gyroscopes

Laboratory tests of the spherical electrostatically levitated cryogenically cooled coated gyroscope being developed for the Gravity Probe B (GP-B) spacecraft (Bardas et al., 1986) are reported. Spin speed and the dc components of the trapped magnetic field are measured with three orthogonal pickup loops attached to SQUID detectors as the levitated gyro is brought up to speed by an He gas jet. Data on the spin-vector time history, mass unbalance, higher rotor-shape harmonics, and spin-vector position are presented in extensive graphs and characterized in detail, and a mathematical model of the electrostatic suspension torques is derived. Prototype gyro 86-4 is found to have mass unbalance within the range required for the GP-B mission (to detect the geodetic and motional effects predicted by general relativity theory).

Keiser, G. M.↗