Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Indigenous Organic Molecular Biosignatures are Detectable via ToF-SIMS of a Kerogen-rich Jurassic Clay

Time of Flight - Secondary Ion Mass Spectrometry (ToF-SIMS) is a Mass Spectrometry (MS) imaging technique that can be used in conjunction with traditional organic geochemical analysis (organics extracted from a crushed sample) in order to determine how molecules observed in the organic extracts were incorporated into a particular rock sample. This type of analysis may be used on samples collected as part of Mars Sample Return (MSR) in order to determine if potential organic compounds were indigenous to Mars or whether they are contaminants.Here we show that Organic Molecular Biosignatures (OMBs including steranes and derivatives of a carotenoid) are detectable via ToF-SIMS within a Jurassic mudstone. The OMBs are only detectable in areas with high organic carbon, likely kerogen, indicating that they are indigenous to the rock. We conclude that: I) Indigenous OMBs are detectable via ToF-SIMS in ancient, kerogen-rich samples; II) the presence of a molecular ion strengthens the interpretation of ToF-SIMS spectra of complex natural material, and III) the spatial co-occurrence of kerogen and potentially indigenous OMBs in ancient sediments is a valid test of their character. These conclusions are directly relevant to MSR sample selection as well as the analysis of MSR samples upon return.

Pasterski, Michael↗

Study of the Au-Cr bilayer system using X-ray reflectivity, GDOES, and ToF-SIMS

Here, we study a Au (25 nm)/Cr (10 nm) bilayer system as a model of mirror for the soft X–ray energy range. The Au and Cr thin films are a few nanometer thick and are deposited on a float glass substrate. The sample is characterized by using 3 complementary techniques: soft X–ray reflectivity, glow discharge optical emission spectrometry (GDOES), and time–of–flight secondary ion mass spectroscopy (ToF–SIMS). Soft X–ray reflectivity provides information about the thickness and roughness of the different layers, while GDOES is used to obtain the elemental depth profile of the stack and ToF–SIMS to obtain the elemental and chemical depth profiles. GDOES and ToF–SIMS have both a nanometer depth resolution. A coherent description of the bilayer stack is obtained through the combination of these techniques. It consists in 5 layers namely a surface contamination layer, a principal gold layer, a Au–Cr mixed layer, a Cr layer, and another contamination layer at the top of the substrate.

36 MATERIALS SCIENCE↗

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Perovskite Inhomogeneity beyond the Surface: TOF-SIMS Analysis of Halide Perovskite Photovoltaic Devices

Understanding the origins and evolution of inhomogeneity in halide perovskite solar cells appears to be a key to advancing the technology. Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from all components of hybrid organic-inorganic perovskite photovoltaics in one dimension (standard depth profiling), two dimensions (high-resolution 100-nm imaging), as well as three dimensions (tomography combining high-resolution imaging with depth profiling). TOF-SIMS has been used to analyze perovskite photovoltaics made by a variety of methods, and the breadth of insight that can be gained from the technique is illustrated here including: cation uniformity (depth and lateral), changes in chemistry upon alternate processing, changes in chemistry upon degradation, and lateral distribution of additives that passivate grain boundaries. Using TOF-SIMS on multiple perovskite compositions, we show information regarding hybrid perovskite formation as well as inhomogeneity critical to device performance can be extracted providing one of the best proxies for understanding compositional changes resulting from degradation. Here, we also describe in detail the measurement artifacts and recommended best practices that enable unique insight regarding hybrid perovskite solar cell materials and devices.

14 SOLAR ENERGY↗

Mitigating Measurement Artifacts in TOF-SIMS Analysis of Perovskite Solar Cells

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is one of the few techniques that can specifically distinguish between organic cations such as methylammonium and formamidinium. Distinguishing between these two species can lead to specific insight into the origins and evolution of compositional inhomogeneity and chemical gradients in halide perovskite solar cells, which appears to be a key to advancing the technology. TOF-SIMS can obtain chemical information from hybrid organic-inorganic perovskite solar cells (PSCs) in up to three dimensions, while not simply splitting the organic components into their molecular constituents (C, H, and N for both methylammonium and formamidinium), unlike other characterization methods. Here, we report on the apparently ubiquitous A-site organic cation gradient measured when doing TOF-SIMS depth-profiling of PSC films. Using thermomechanical methods to cleave perovskite samples at the buried glass/transparent conducting oxide interface enables depth profiling in a reverse direction from normal depth profiling (backside depth profiling). When comparing the backside depth profiles to the traditional front side profiled devices, an identical slight gradient in the A-site organic cation signal is observed in each case. This indicates that the apparent A-site cation gradient is a measurement artifact due to beam damage from the primary ion beam causing a continually decreasing ion yield for secondary ions of methylammonium and formamidinium. This is due to subsurface implantation and bond breaking from the 30 keV bismuth primary ion beam impact when profiling with too high of a data density. Here, we show that the beam-generated artifact associated with this damage can mostly be mitigated by altering the measurement conditions. We also report on a new method of depth profiling applied to PSC films that enables enhanced sensitivity to halide ions in positive measurement polarity, which can eliminate the need for a second measurement in negative polarity in most cases.

14 SOLAR ENERGY↗

ToF-SIMS evaluation of PEG-related mass peaks and applications in PEG detection in cosmetic products

Polyethylene glycols (PEGs) are used in industrial, medical, health care, and personal care applications. The cycling and disposal of synthetic polymers like PEGs pose significant environmental concerns. Detecting and monitoring PEGs in the real world calls for immediate attention. This study unveils the efficacy of time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a reliable approach for precise analysis and identification of reference PEGs and PEGs used in cosmetic products. By comparing SIMS spectra, we show remarkable sensitivity in pinpointing distinctive ion peaks inherent to various PEG compounds. Moreover, the employment of principal component analysis effectively discriminates compositions among different samples. Notably, the application of SIMS two-dimensional image analysis visually portrays the spatial distribution of various PEGs as reference materials. The same is observed in authentic cosmetic products. The application of ToF-SIMS underscores its potential in distinguishing PEGs within intricate environmental context. ToF-SIMS provides an effective solution to studying emerging environmental challenges, offering straightforward sample preparation and superior detection of synthetic organics in mass spectral analysis. These features show that SIMS can serve as a promising alternative for evaluation and assessment of PEGs in terms of the source, emission, and transport of anthropogenic organics.

36 MATERIALS SCIENCE↗

Understanding Measurement Artifacts Causing Inherent Cation Gradients in Depth Profiles of Perovskite Photovoltaics with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from the hybrid organic-inorganic perovskite solar cells (PSCs) in one dimension (standard depth profiling), two dimensions (high-resolution 100-nm imaging), as well as three dimensions (tomography combining high-resolution imaging with depth profiling). We have very recently developed thermo-mechanical methods to cleave perovskite samples at the back transparent conducting oxide/PSC interface. This allowed for depth-profiling from the back of the device to the front. The resultant profiles answered the lingering question of the apparent A-site cation gradient typically seen in TOF-SIMS depth profiles. In fact, this gradient is a measurement artifact due to beam damage that the community should be informed of as TOF-SIMS data become more commonly employed. Methods of mitigating this artifact by altering the measurement conditions are also presented.

14 SOLAR ENERGY↗

Towards Automated and High-Throughput Quantitative Sizing and Isotopic Analysis of Nanoparticles via Single Particle-ICP-TOF-MS

The work described herein assesses the ability to characterize gold nanoparticles (Au NPs) of 50 and 100 nm, as well as 60 nm silver shelled gold core nanospheres (Au/Ag NPs), for their mass, respective size, and isotopic composition in an automated and unattended fashion. Here, an innovative autosampler was employed to mix and transport the blanks, standards, and samples into a high-efficiency single particle (SP) introduction system for subsequent analysis by inductively coupled plasma–time of flight–mass spectrometry (ICP-TOF-MS). Optimized NP transport efficiency into the ICP-TOF-MS was determined to be >80%. This combination, SP-ICP-TOF-MS, allowed for high-throughput sample analysis. Specifically, 50 total samples (including blanks/standards) were analyzed over 8 h, to provide an accurate characterization of the NPs. This methodology was implemented over the course of 5 days to assess its long-term reproducibility. Impressively, the in-run and day-to-day variation of sample transport is assessed to be 3.54 and 9.52% relative standard deviation (%RSD), respectively. The determination of Au NP size and concentration was of <5% relative difference from the certified values over these time periods. Isotopic characterization of the 107 Ag/ 109 Ag particles (n = 132,630) over the course of the measurements was determined to be 1.0788 ± 0.0030 with high accuracy (0.23% relative difference) when compared to the multi-collector–ICP-MS determination.

36 MATERIALS SCIENCE↗

Probing Aqueous Surfaces by ToF-SIMS

We report the first observations of aqueous surfaces by a time-of-flight secondary ion mass spectrometer (ToF-SIMS) via a self-contained microfluidic module compatible in vacuum. The interface uses a microfluidic channel with a 3 {micro}m diameter window into the flowing fluid beneath it. This window supports the liquid against the vacuum by the liquid's surface tension and limits the high-density vapor region traversed by the probe beams to only a few micrometers. We demonstrate detections of aqueous surfaces such as deuterium water and sodium iodide (NaI) solution through the small aperture by ToF-SIMS. Even more, molecular signals (M-H-) of glutamic acid (C5H8NO4-) are observed. ToF-SIMS coupled with the novel interface provides a molecular recognition capability, making it a great choice to detect short-lifetime reaction intermediates in aqueous solutions. This novel microfluidic interface makes multimodal vacuum based analysis of liquid surface possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of initial and steady-state sliding behavior of a nearly-frictionless carbon film by imaging 2- and 3-D TOF-SIMS.

Using imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS), we investigated the initial and steady-state sliding behavior of a nearly frictionless carbon (NFC) film. Specifically, TOF-SIMS images (both 2-D and 3-D) of these surfaces were constructed to highlight the spatial distributions of ionized and molecular species that were present on as-received and friction-tested NFC surfaces and as a function of depth. As a complementary technique, we used X-ray photoelectron spectroscopy (XPS) to gain further insight into the chemical nature of the sliding surfaces. The NFC films were produced on Si wafers and steel substrates in a gas discharge plasma that consisted of 25 vol.% methane and 75 vol.% hydrogen using a plasma-enhanced chemical vapor deposition (PECVD) system. They were then subjected to sliding friction and wear experiments in a pin-on-disk machine under 5- and 10-N loads and at sliding velocities of 0.2-0.5 m/s in dry nitrogen. The initial friction coefficients of the NFC films were in the range of 0.05-0.1, but decreased rapidly to values less than 0.01 at steady state. Positive and negative TOF-SIMS spectra and 2- and 3-D images reconstructed from selected masses revealed that the elemental distribution of certain chemical species differs substantially between undisturbed and tribo-tested areas of the NFC films. Specifically, the tribo-tested areas are essentially made up of carbon and hydrogen, while undisturbed or as-received areas are covered by a layer that is rich in oxygen and other species. These findings correlate well with the initial and steady-state friction coefficients of these films and help further explain their superlubricity in inert test environments.

03 NATURAL GAS↗

Investigation of the Ionization Mechanism of NAD{sup +}/NADH-Modified Gold Electrodes in ToF-SIMS Analysis

Analysis of nicotinamide adenine dinucleotide (NAD{sup +}/NADH)-modified electrodes is important for in vitro monitoring of key biological processes. In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to analyze NAD{sup +}/NADH-modified gold electrodes. Interestingly, no obvious characteristic peaks of nicotinamide fragment could be observed in the mass spectra of NAD{sup +}/NADH in their neutral sodium pyrophosphate form. However, after acidification, the characteristic peaks for both NAD{sup +} and NADH were detected. This was due to the suppression effect of inner pyrophosphoric salts in both neutral molecules. Besides, it was proved that the suppression by inner salt was intramolecular. No obvious suppression was found between neighboring molecules. These results demonstrated the suppression effect of inner salts in ToF-SIMS analysis, providing useful evidence for the study of ToF-SIMS ionization mechanism of organic molecule-modified electrodes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 90 ° bend curved light-guide for TOF scintillating detectors

We report here a bench study of TOF resolution using a 90° bend curved solid light-guide (LG) used to transport the light from a plastic scintillator counter to a photomultiplier (PMT). The 90° LG allows the rotation of the PMT axis to be vertical to the detector axis, in an environment featured by a strong magnetic field along the detector surface, or other geometrical constrains. We show that with a TOF counter of 2000 x 100 x 60 mm 3 and light read-out by PMTs at its two 100 × 60 mm 2 sides, when 90° LG benders are used between the scintillating bar and the PMTs on both sides, the TOF resolution is worsen, by 5–10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TOF Electron Energy Analyzer for Spin and Angular Resolved Photoemission Spectroscopy

Current pulsed laser and synchrotron x-ray sources provide new opportunities for Time-Of- Flight (TOF) based photoemission spectroscopy to increase photoelectron energy resolution and efficiency compared to current standard techniques. The principals of photoelectron timing front formation, temporal aberration minimization, and optimization of electron beam transmission are presented. We have developed these concepts into a high resolution Electron Optical Scheme (EOS) of a TOF Electron Energy Analyzer (TOF-EEA) for photoemission spectroscopy. The EOS of the analyzer includes an electrostatic objective lens, three columns of transport lenses and a 90 degree energy band pass filter (BPF). The analyzer has two modes of operation: Spectrometer Mode (SM) with straight passage of electrons through the EOS undeflected by the BPF, allowing the entire spectrum to be measured, and Monochromator Mode (MM) in which the BPF defines a certain energy window inside the scope of the electron energy spectrum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE↗

Size Characterization of Colloidal Platinum Nanoparticles by MALDI-TOF Mass Spectrometry

In this work, matrix assisted laser desorption ionization-time-of-flight (MALDI-TOF) mass spectrometry (MS) has been utilized to characterize colloidal platinum nanoparticles synthesized in the 1-4 nm size range. The nanoparticles were prepared via a solution-based method in which the size could be controlled by varying reaction conditions, such as the alcohol used as the reductant. Poly(vinylpyrrolidone), or PVP, (MW = 29,000 g/mol) was employed as a capping agent to stabilize the synthesized nanoparticles in solution. A model for determining the size of the metallic nanoparticle core from MALDI-TOF mass spectra has been developed and verified through correlation with particle sizes from transmission electron microscopy (TEM) and X-ray diffraction (XRD) measurements. In this model it was assumed that 1.85 nm nanoparticles are capped by one PVP chain, which was verified through experiments performed with capped and uncapped nanoparticles. Larger nanoparticles are capped by either two (2.60 and 2.94 nm) or three (3.69 nm) PVP chains. These findings clearly indicate the usefulness of MALDI-TOF MS as a technique for fully characterizing nanoscale materials in order to elucidate structure-property relationships.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical method for evaluating catalytic turnover frequencies (TOF) of moderate to slow H2 oxidation electrocatalysts

Hydrogen has emerged as a long-term option for storing energy from renewable resources and has led the scientific community to develop enzyme-inspired catalysts for hydrogen oxidation and production. One of the most productive families of catalysts for H2 oxidation is the pendant amine containing bis-(diphosphine)nickel catalysts. Many derivatives of these nickel complexes have been prepared with varying peripheral functionalities to understand their structure-function relationship. Electrocatalysis is currently utilized as the primary tool to measure the catalytic turn over frequencies (TOFs) of these complexes, however, it does not allow accurate determination of TOFs for slow (< 1 s-1) to moderately active (~ 1-10 s-1) catalysts, and for the slowest catalysts, it can be difficult to determine if they are turning over at all. Further, it does not allow the determination of the TOF in bulk solution. In this work, we demonstrate that using a redox chemical procedure involving a change between ferrocenium cation to ferrocene can be utilized to monitor H2 oxidation catalysts. The ferrocenium cation reoxidizes the reduced nickel catalyst stoichiometrically in the presence of H2. The change of ferrocenium cation to ferrocene can be monitored in both organic and aqueous solvents via either optical spectroscopy or NMR spectroscopy. Thus, this chemical method complements the existing electrocatalytic procedure and may help to unravel the intricate details of even the slowest H2 oxidation catalysts.

Dutta, Arnab↗

Microstructure-dependent particulate populations in ODS steels revealed by single-particle ICP-TOF-MS

In this work, we evaluated the ability of single-particle inductively coupled plasma time-of-flight mass spectrometry (SP-ICP-TOF-MS) to characterize particulates generated from 300 series stainless steels and oxide dispersion–strengthened (ODS) steels. Particulates were produced using two different rotary tools (cutting disk and grinding bit) to assess the influence of particle generation on effluent particulates. Across all materials and preparation techniques, SP-ICP-TOF-MS detected a substantial population of particles containing the expected constituent elements, with average compositions closely matching the nominal alloy values. A secondary population of Y-bearing particles was evident in ODS steels; their formation is strongly favored in particulates generated using the grinding bit. Specifically, in PM2000, Y-bearing particles were predominantly colocated with Al, whereas in 14YWT, Y-bearing particles were less frequently Fe-free but showed stronger colocation with Ti. These trends are consistent with the known microstructural differences between Y–Al–O oxide particles in PM2000 and finer Y–Ti–O nanoclusters in 14YWT. Together, these results demonstrate that SP-ICP-TOF-MS can resolve distinct particulate populations in complex, multicomponent steels at the femtogram mass scale, enabling particle-resolved insight into microstructure-driven phase separation and preparation-dependent particle generation.

Brubaker, Zach E. [Oak Ridge National Laboratory (↗

Time Of Flight Accelerator Mass Spectrometry (TOF-AMS) of Large Molecular Ions at MeV Energies

The feasibility of using TANDEM electrostatic particle accelerators as a linear TOF analyzer for molecular ions (TOF-AMS) is reported in this work. A specific ion source, based on a soft ionization technique commonly used in modern mass spectrometry, employing a pulsed UV-laser to desorb molecular ions from the solid state, was built for that purpose. The current instrumentation has been used to analyze samples of CsI and C{sub 60} using the whole accelerator as a linear Time of Flight spectrometer. From the point of view of basic studies on molecular collisions, the apparatus has some unique features that allow the simultaneous discrimination of various fragmentation and charge exchange channels for different types of molecular ions. From the point of view of applied studies, the TOF-AMS technique may be able to overcome some difficulties encountered in mass spectrometry of biomolecules.

74 ATOMIC AND MOLECULAR PHYSICS↗